Can anyone point me to some good instructions on how to set up SNMPv3 on a Cisco Catalyst 2960-S switch in order to manage it with Cisco Prime NCS?

here is link which explains snmp config for 2960s
http://www.cisco.com/en/US/docs/switches/lan/catalyst2960/software/release/12.2_55_se/configuration/guide/swsnmp.html#wp1076836

Similar Messages

  • Nexus 2K to Cisco 2960 IOS Switch

    Hi,
    I am trying to connect Nexus 2K FEX to Cisco 2960 IOS Switch (Trunk config) and causing spanning tree loop having issues. I am aware that I should't be connecting non host port to 2K FEX but it's corner case. I have done similar setup with Access Port configuration and didn't faced any issues.
    Nexus 5K config Config 
    interface Ethernet107/1/47
      switchport mode trunk
      switchport trunk allowed vlan 500-501
      spanning-tree guard root
      spanning-tree bpdufilter enable 
    interface Ethernet108/1/47
      switchport mode trunk
      switchport trunk allowed vlan 500-501
      spanning-tree guard root
      spanning-tree bpdufilter enable 
    2960-Config 
    interface GigabitEthernet1/0/47
      switchport mode trunk
      switchport trunk allowed vlan 500-501
     spanning-tree bpdufilter enable
    interface GigabitEthernet1/0/48
      switchport mode trunk
      switchport trunk allowed vlan 500-501
     spanning-tree bpdufilter enable
    Error Log
    %FWM-2-STM_LOOP_DETECT: Loops detected in the network for mac 001b.1700.0130 among ports Eth107/1/47
    Eth108/1/47 vlan 500 - Disabling dynamic learn notifications for 180 seconds 
    Should I configure port as "spanning-tree port type network" and create VPC and "storm-control broadcast level" to stop future occurrence?  OR Do i have to configure anything else to prevent spanning-tree loops? 
    Thanks for your help
    Ritesh

    Hi,
    spanning-tree port type network is used for VPC peer-link.  Try creating a new VPC and add ports 107/1/47 and 108/1/47 to it and a Portchannel on the 2960 and test.
    HTH

  • Recovery missing or corrupted IOS of Cisco 2960 Catalyst Switch

    Dear Team,
    I have Cisco 2960 48P switch, It is keep getting restarted and config was erased.
    when I tried to run the IOS from hypertrm in room mode, I am getting below error..
    My doubt is, is there any issue with hardware & what is the cause of for below error 
    suggest me, is there any option to upgrade the IOS?
    switch: flash_init
    Initializing Flash...
    flashfs[0]: 0 files, 1 directories
    flashfs[0]: 0 orphaned files, 0 orphaned directories
    flashfs[0]: Total bytes: 32514048
    flashfs[0]: Bytes used: 1024
    flashfs[0]: Bytes available: 32513024
    flashfs[0]: flashfs fsck took 9 seconds.
    ...done Initializing Flash.
    switch: copy xmodem: flash:c2960-lanbasek9-mz.122-50.SE5.bin
    Begin the Xmodem or Xmodem-1K transfer now...
    CCCCBB0BB0................flashfs[0]: filesystem marked down.  Use "fsck" to rec
    over.
    flash:c2960-lanbasek9-mz.122-50.SE5.bin: interrupted system call
    switch:

    Error message means your BIN file is corrupt.  You need to download again from the Cisco website.

  • Help for Cisco 2960 48port switch not working

    I had downloaded the template from the wiki for Cisco 48 port switch,unfortunately, it seems doesn't work.Are there other places where i can find WS-C2960S-48TS-L switch ? I also search the internet to find most people like to buy cisco product at Router-Switch.com with reliable quality and competitive price.Can give me the advice if i want to buy switch on this website ?

    Please read over this FAQ and see if any of it might apply to you.
    http://www.blackberryfaq.com/index.php/Errors_syncing_the_BB_with_Desktop_Manager
    1. If any post helps you please click the below the post(s) that helped you.
    2. Please resolve your thread by marking the post "Solution?" which solved it for you!
    3. Install free BlackBerry Protect today for backups of contacts and data.
    4. Guide to Unlocking your BlackBerry & Unlock Codes
    Join our BBM Channels (Beta)
    BlackBerry Support Forums Channel
    PIN: C0001B7B4   Display/Scan Bar Code
    Knowledge Base Updates
    PIN: C0005A9AA   Display/Scan Bar Code

  • Cisco 2960 Series Switch Architecture

    Hi all,
    I wanted to know if there is a document or an article which describes 2960 series architecture specifically for model WS-C2960-24-S as there is for 2600 series in the following link:
    http://www.cisco.com/c/en/us/support/docs/routers/2600-series-multiservice-platforms/23852-2600-architecture-23852.html
    Thanks.

    Hi,
    You should be able to find the information that you need here:
    http://www.cisco.com/c/en/us/support/switches/catalyst-2960-24-s-switch/model.html
    Thanks,
    Jake

  • Increasing TFTP block size for 2960 series switches

    I have read that some Cisco components can increase the default TFTP block size to values greater than 512 bytes by using the command -
    ip tftp blocksize xxxx
    This doesn't seem to be available on Cisco 2960 series switches. Is there a way to do this with the 2960's?

    I have moved a WS-C2960-24LC-S running LanLite to 12.2(55)SE9 - the current end of the line for this switch - and indeed the command is not present. Sooo....this appears to be a limitation of LanLite.
    My predecessor implemented about 70 switches with LanLite. I put a stop to this about a year ago but it is going to take some time to flush them out of the inventory.
    Thanks for your response.

  • Cisco 2960S SFF8472-5-THRESHOLD_VIOLATION

    Hi All
    I have a issue connecting my Cisco 3750X 12 port fibre switch to my Cisco 2960S 24Port switch using Multi Mode Fibre.
    I have Mode condtioning cables connecting to the SFP (GLC-LH-SMD) on the 3750 via a fibre patch panel which bring me to the 2960s with its Mode conditioning cable and SFP (GLC-LH-SMD).
    The fibre port on the Cisco 2960S was up for all of 10 mins and has gone out with the following error message.
    %SFF8472-5-THRESHOLD_VIOLATION: Gi1/0/26: Rx power high warning; Operating value:  -2.7 dBm, Threshold value:  -3.0 dBm.
    I did a show int transceiver command and got the following output.
    DS-THN-SW3#show interfaces transceiver
    If device is externally calibrated, only calibrated values are printed.
    ++ : high alarm, +  : high warning, -  : low warning, -- : low alarm.
    NA or N/A: not applicable, Tx: transmit, Rx: receive.
    mA: milliamperes, dBm: decibels (milliwatts).
                                     Optical   Optical
               Temperature  Voltage  Tx Power  Rx Power
    Port       (Celsius)    (Volts)  (dBm)     (dBm)
    Gi1/0/26     25.2       3.31      -5.1     -28.5
    All SFP's are new as is the Multi Mode Fibre cable running from one building to another.

    Hi All,
    One of  member port of port channel was flapping and Here is the error message
    Error log:
    .Mar 17 08:27:37: %SFF8472-5-THRESHOLD_VIOLATION: Te6/1/1: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -11.3 dBm.
    Cisco TAC analyse the issue under 629566213 but  their initial advices was not much experience oriented.
    Finally I have resolved the issue just by entering following command.
    switch 6 frulink reload
    Janaka Wellege Bsc.Eng
    University of Peradeniya.

  • Cisco 2960S Configured in Transparent mode

    I have a Cisco 2960S gig switch configured in transparent mode with multiple vlans configured. I have printers that I can ping, the ports shows up but on the printer it says offline. Any idea what could be causing this?

    If your printer and your PCs are all in the same subnet and only the printer is not working then VTP mode Transparent has nothing to do with your issue. 
    I'd be keen to know if you have a firewall blocking anything from the IP address of the printer?  Maybe the IP subnet mask or default gateway of the printer is not working?  
    What do you get when you do a "sh mac-address interface <PRINTER port>"?

  • Low Transfer Rate On 2960-S Switch

    Hi,
    I have 2 PCs (1gbps lan card each ) connected to Cisco 2960-S switch.
    The bandwidth of all ports on 2960-S is set to 1gbps manually.
    However whenever I transfer any file between the two I don't get transfer rate more than 12MBps/96mbps.
    Theoretically it should be 125MBps but why am I getting such low transfer rate?
    Regards. 

    Disclaimer
    The Author of this posting offers the information contained within this posting without consideration and with the reader's understanding that there's no implied or expressed suitability or fitness for any purpose. Information provided is for informational purposes only and should not be construed as rendering professional advice of any kind. Usage of this posting's information is solely at reader's own risk.
    Liability Disclaimer
    In no event shall Author be liable for any damages whatsoever (including, without limitation, damages for loss of use, data or profit) arising out of the use or inability to use the posting's information even if Author has been advised of the possibility of such damage.
    Posting
    Bandwidth is set manually, eh?  Have you checked for a duplex mixmatch?

  • Power up cisco 2960 switch with 12V DC Power

    hi all ,
    I have some issue with supply power to cisco 2960-24TT-L switch. In my server farm rack is having DC current of -48V. But however cisco switch require 12V DC current.
    Cisco Spec.
    Cisco Catalyst 2960-24TT-L
    12V at 5 A
    5 A
    How can I power on the switch using DC current ?  Is there any power converter which I can purchase ? your responses are very much.
    Thanks

    You may also go here: 
    https://supportforums.cisco.com/community/netpro/small-business
    The Search Function is your friend.... and Google too.
    How to Secure your Network
    How to Upgrade Routers Firmware
    Setting-Up a Router with DSL Internet Service
    Setting-Up a Router with Cable Internet Service
    How to Hard Reset or 30/30/30 your Router

  • Cisco 2960S FPS-L PoE switch with Avaya 9811g VOIP setup

    Hello,
    I am connecting a setup for data/voice connecting Catalyst 2960S-FPS-L PoE switch with Avaya 9811g series VOIP phone. As per my knowledge cisco switch works well with Cisco phone as it has got some builtin "Macros" and Intelligent PoE recognition when we connect device getting the details of another device through CDP. I understand I have to create data and voice vlan with QOS then enable trunking on the interface to other switch that is also 2960. Little confuse if is there any compatibility issues with Switch and Avaya phone regarding protocol/data/voice...?
    Do I have to do PoE config for each port on the each interface?
    any help or detail config will help.
    Thanks in advance.

    Hi I am back after good research. created two vlan data and voice with trunk on interface1/0/48 given below config..
    connection b/w 2960s FPS Switch and Avaya 9611g IP Phone.
    lldp/cdp is enable on switch
    So I created this config if some one can take a look .
    expert advise if something wrong?..
    I am only concern with Voice and PoE as voice is my priority. do i have to map something for voice quality?
    also if i create another Trunk port one allow voice other allow data both cable will go to switch will that be issue?
    interface....
    switchport access vlan x
    switchport mode access
    switchport nonegotiate
    switchport voice vlan xx
    srr-queue bandwidth share 10 10 60 20
    queue-set 2
    priority-queue out
    mls qos trust cos
    auto qos voip trust
    spanning-tree portfast
    interface ........
    switchport trunk allowed vlan x,x
    switchport mode trunk
    switchport nonegotiate
    srr-queue bandwidth share 10 10 60 20
    queue-set 2
    priority-queue out
    mls qos trust cos
    auto qos voip trust

  • As clear memory dead Switch cisco 2960

    Hello All !!
    As Clear memory dead process I/O Switch cisco 2960 ?

    I do not speak English perfectly, I'll try to summarize 
    Switch this process my memory I / 0 Very High, restart several times, but the process does not diminish.
    thank you.

  • How to priorities(QoS) the traffic for DSCP 46 and 34 in cisco 2960s switch

    HI,
    We are going to implement Microsoft Lyncs 2013 in our network, so how to priorities the traffic for DSCP 46 and 34 in cisco 2960s switch. Kindly replay with detailed QoS commands for enabling QOs in LAN.
    Thanks
    Sujish

    Hi,
    Have a look at this config guide for all the details:
    http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst2960/software/release/12-2_53_se/configuration/guide/2960scg/swqos.html
    HTH

  • How to connet cisco 2960S switch to sony nexus 7?

    I want to buy an cisco WS-C2960S-24TS-S switch to help me solve business networking problem. Can someone help me to connect cisco 2960s switch to nexus 7 ?

    I don't need to do anything config on the new switch, I just need to upgrade the new switch's IOS version as the existing stack.
    Correct.  Upgrade using the command "archive download-sw" instead copying the BIN files.  
    After doing above task, I connect all stack cable and power cord as you said, and then the new switch can be synchronized with the MASTER switch. right??
    Correct.  The new switch should NOT have any configuration.  This includes VLAN.dat file.

  • Alteon Switch to Cisco 2960 port aggrigating

    LACP / 802.3ad is required to aggrigate a cisco to a non cisco switch, is there any issues connecting a Cisco 2960 to a Alteon Switch.

    There should be none as long as alteon support LaCP, 2960 certainly do. for configuration guide info, have a look at the following:
    http://www.cisco.com/univercd/cc/td/doc/product/lan/cat2960/12225see/scg/swethchl.htm
    Please rate all posts.

Maybe you are looking for