SOLMAN SMD Wily Introscope: no dashboards are available

Hi!
I would like to use the SAP SMD functions and Wily Introscope 8.0
I am on SAP SOLMAN 7.0 EhP1.
The problem I have: when I start Wily Introscope no dashboards are available.
Can some one help me to solve this problem?
Thank you very much!
regards
Axel

You might have already checked the SAP Note 797147 and   installation guide for Wily I 8.0 at
http://service.sap.com/instguides -> Installation & Upgrade Guides -> SAP Components -> SAP Solution Manager -> Release 7.0 -> Wily Introscope 8.0 - Installation Guide
From the installation guide could you confirm section ..."Check That Introscope Is Running Properly"
Also confirm you have set Java VM Parameters...
I think you need to check the Installation guide thoroughly.
Let us know if you have any error log or something....
All the best.

Similar Messages

  • SOLMAN SMD Wily Introscope

    Hi!
    Has some one experience working with Wily Introscope 8.0?
    I use currently the version 7.2 and would like to upgrade this version to Wily Introscope 8.0.
    When I do so I cannot install and run Wily Introscope 8.0.
    Any helpful information will be very appreciated!
    regards
    Axel Schulze

    Hi Axel
    I am planning to un-install my current wily 7.2 and plannign to install 8.0, can you let me know if you have already completed upgrading and also can you send me details on the upgrade.
    Thanks
    Reddy

  • Wily Introscope Dashboard cannot be started: Silverlight Error 2104

    Dear Gurus,
    we have installed a DualStack SolMan 7.0 Ehp1 SPS23 on AIX/Oracle.
    Diagonstics and WilyEM 8.2 is installed and running well, Data from Agetens SMD7.11 and IntroscopeBytecodeAgents data are displayed also in Wily Introscope Webview  - Investigator tab.
    Silverlight 4 is installed since last May.
    Last week the regular Microsoft-Patching did on our FrontendWorkstations (WinXP SP3) with IE7 
    Additionally there was an upgrade of our SolMan Operating-System drom AIX5.3 to AIX6.1
    During this update also an JAVA 1.5 was newely installed for WilyEM, and the parameter " "the VM to use for the next launch" in the lax-file points to this Java-Version:    java full version "J2RE 1.5.0 IBM AIX build pap64dev-20091106a (SR11 )"
    But today we recognized - after sucessfully start of Wily EM WebView - that there is a problem when we try to select one of the prepared Dashboards from SAP and press the "View"-Button:
    We get an ErrorMessageBox from IE whichs saids:
    "Silverlight error:"
    "Error Type:  InitializeError"
    ErrorMessage:2104"
    and no Dashboard comes up.  
    The same Error occours when we use antoher Browser ?
    Can anybody please help ?
    What could be the reason or solution for this kind of error ?
    Thanks a lot !
    Stephan

    Dear Mateus,
    unfortunately I wasn't able to use your workaround successfully:
    Even when I mark the "Consoile"-Tab and press the "Refreh"-Button to reload the Page, i still get the same Error-Messages...
    Are there newer/other fixes available to solve this problem ?
    Which fix do you mean exactly ?   We currently run following version of WilyEM / WebView (from IntroscopeEMWebView.log)
    10/22/10 10:54:23 AM GMT+01:00 [INFO] [WebView] Introscope WebView Release 8.2.2.0 (Build 476364)
    10/22/10 10:54:23 AM GMT+01:00 [INFO] [WebView] Using Java VM version "IBM J9 VM 1.5.0" from IBM Corporation
    10/22/10 10:54:23 AM GMT+01:00 [INFO] [WebView] Using Introscope installation at: /usr/sap/ccms/wilyintroscope/.
    10/22/10 10:54:23 AM GMT+01:00 [INFO] [WebView] CA Wily Introscope(R) Version 8.2
    10/22/10 10:54:23 AM GMT+01:00 [INFO] [WebView] Copyright (c) 2010 CA. All Rights Reserved.
    10/22/10 10:54:23 AM GMT+01:00 [INFO] [WebView] Introscope(R) is a registered trademark of CA.
    10/22/10 10:54:23 AM GMT+01:00 [INFO] [WebView] Starting Introscope WebView...
    10/22/10 10:54:23 AM GMT+01:00 [INFO] [WebView] Introscope WebView started.
    10/22/10 10:54:27 AM GMT+01:00 [INFO] [WebView.Login] Successfully logged in user "WilyWebView"
    10/23/10 11:08:07 AM GMT+01:00 [ERROR] [WebView] java.lang.ClassCastException: org.apache.xml.dtm.ref.DTMManagerDefault incompatible with
    org.apache.xml.dtm.DTMManager
    10/23/10 11:08:18 AM GMT+01:00 [ERROR] [WebView] java.lang.ClassCastException: org.apache.xml.dtm.ref.DTMManagerDefault incompatible with
    org.apache.xml.dtm.DTMManager
    10/23/10 11:12:19 AM GMT+01:00 [ERROR] [WebView] java.lang.ClassCastException: org.apache.xml.dtm.ref.DTMManagerDefault incompatible with
    org.apache.xml.dtm.DTMManager
    10/23/10 11:12:34 AM GMT+01:00 [ERROR] [WebView] java.lang.ClassCastException: org.apache.xml.dtm.ref.DTMManagerDefault incompatible with
    org.apache.xml.dtm.DTMManager
    10/23/10 11:12:58 AM GMT+01:00 [ERROR] [WebView] java.lang.ClassCastException: org.apache.xml.dtm.ref.DTMManagerDefault incompatible with
    org.apache.xml.dtm.DTMManager
    Thanks,
    Stephan

  • Wily introscope issue after System refresh in solman 7.1 Sp11

    Hello experts,
    Unable to remove old Production wily in quality system.
    An new wily has installed in development box but when i run Solman_setup -> basis configuration ->cofig wily
    Unable to unassign or delete old wily introscope
    Thanks ,
    Rahul Yedapally

    Hi Rahul,
    Check in expert mode , diagnostic agent of development system should appear in quality SMD agent administration as you are assigning DEV wily to SOLMAN QUA.
    and all so make sure RFCs WEBADMIN , SOLMANDIAG and
    NONE are working fine in SOLMAN.
    Thanks,
    Prakash Reddy Maram

  • Solman E2E diagnostics and Wily Introscope.

    Does anybody have any time scales for setting up Solman Diagnostcis and Wily Introscope. I have a quote for this work and would like peoples past experience of time scales for this.
    I have a 3 system landscape PRD, QUA, DEV and obviously SOLMAN.
    I need  to set up the SMD agents on each server involved and install the required Wily components

    HI,
    If you have downloaded all the necessary s/w then you complete the E2E RCA setup in 1 day for one system(including buffers)  including Wily.
    E2E RCA config, can be completed as part of solman_setup. Once you have completed your initial and basic setup, solman is ready for managed system config.
    I would recommend following timeline including buffer
    two - three  days for Basic configuration and initial configuration.
    Installation of SMD takes less than 20 mins/ host. Wily installation also should not take more than an hour
    Managed system config - this depends on which application are you configuring. in case of SAP application, you should be able to finish one SID in one day (including buffer)
    BR,
    Shyam

  • Wily Introscope for SOLMAN 7.1

    Hi All,
    We are configuring SAP Solution Manager 7.1
    I have few doubts regarding Wily Introscope.
    1. Is it necessary to install Wily Introscope on SAP SOLMAN 7.1?
    2. Is it installed already with SOLMAN or need to be installed manually?
    3. I need details about licensing policy of Wily Introscope.
    4. If it is necessary to install please provide suitable link for installing it.
    and I have one more question.
    We getting waring message for Single Sign On and WEB Services Logical Port Creation in Managed System Configuration Step No. 8 Configure Automatically.
    Shall we proceed with warning. or it needs to be fully performed without warning.
    Please guide us.
    Thanks & Regards,
    Ishan

    Ishan trying to answer all your doubts:
    1. Is it necessary to install Wily Introscope on SAP SOLMAN 7.1?
    If you need to implement RCA then only Wily Introscope is required.
    2. Is it installed already with SOLMAN or need to be installed manually?
    It has to be installed manually..Just follow the standard guide..
    3. I need details about licensing policy of Wily Introscope.
    Good Question..I think there should be someone in your orgnisation who looks after the licencing..Ask him to give  a call to SAP..
    4. If it is necessary to install please provide suitable link for installing it.
    Follow this link :
    http://www.scribd.com/doc/36673011/Wily-Intro-Scope-8-Installation-Guide
    Thanks & Regards,
    Joydeep

  • Is Wily Introscope a requirement with Solman 7 ehp1

    We are finishing and upgrade from 3.2 to 7 EHP1.
    Due to limited system capacity we have not installed the Wily Introscope product.  At this time we were not planning on using its functionality.  We are wanting to keep the basic functionality of solman 3.2 plus add the MOPZ piece.
    I'm using the solman_setup tcode to go through the basic config wizard now.  I've reached the Landscape Data step where it is asking for the Wily Introscope info.  Since it doen't exist, can I bypass this step?
    Thanks for your advice.
    Laurie McGinley

    Thanks Jarad,
    That is what I thought (it isn't required), but needed to double check before I bypassed that bit of the setup.
    Appreciate the quick response too!
    Laurie

  • Is Wily Introscope User manual Available?

    Hello,
    We have installed Wily Introscope 7.1 , Enterprise Manager on a seperate host.
    We are able to see graphical represenatation of many parameters.
    Now we want to customise the parameter & configure the alerts for  perticular values.
    Does any know how to customise/alter/configure these parameters?
    IS ther any User Manual for this available.
    Your help will be highly appreciated!
    Thanks and regards,
    Pradnya

    Hi pradnya,
    this is what I've found:
    <b>Introscope WebView User Guide for SAP, Release 7.1</b>-
    https://websmp208.sap-ag.de/~sapdownload/011000358700000080622007E/
    <b>Introscope Workstation User Guide, Release 7.1</b> -
    https://websmp208.sap-ag.de/~sapdownload/011000358700000080632007E/
    <b>Introscope Glossary, Release 7.1</b> -
    https://websmp208.sap-ag.de/~sapdownload/011000358700000080642007E/
    Dimitry Haritonov

  • Do we have a feature of export the names of the reports and dashboards that are available in OBIEE?

    Is there any option to export the names of the reports and dashboards that are available in OBIEE?

    Hi,
    You can create report using catalog manager:
    1. Open catalog in Online mode.
    2. Select shared folder & then click on Tool-> create report.
    3. For report name -> select Analysis from drop down list & move "Name" in right pane(or whatever detail u want, u can select from list).
    4. For Dashboard -> select Dashboard from drop down list & then move name in right pane.
    5. Click OK  & save report.

  • Wily Introscope on two server nodes - are there two connectors necessary?

    Dear all,
    we' ve installed Wily Introscope on our portal which has two java server nodes. As I' ve read in SDN every Wily agent on a server has his own name, here ABC_Portal_server0 and ABC_Portal_server1.
    In section 4 of the Wily Introscope installation manual the creation of the AutoProbe connector is described. Do we have to create two AutoProbe connector files (one for each agent) or only one for both agents?
    Thank you for your suggestions.
    Best regards
    Martin Röhr

    Hi Achim,
    According to my knowledge, there are no known problems with a "required Extended Protection" / "Always On" / "Livelink Server" combination.
    Extended Protection helps to prevent an authentication relay attack by using service binding and channel binding. We need to note that when Extended Protection is set to
    Required, only connections from protected applications on protected operating systems are accepted. This setting is the most secure but connections from operating systems or applications that do not support Extended Protection will not be able
    to connect to SQL Server. For more details, please review the following article.
    Connect to the Database Engine Using Extended Protection
    https://msdn.microsoft.com/en-us/library/ff487261(v=sql.110).aspx
    Thanks,
    Lydia Zhang
    If you have any feedback on our support, please click
    here.
    Lydia Zhang
    TechNet Community Support

  • Wily Introscope prerequisite

    Hello,
    We want to implement Wily introscope in our landscape . We have 1 Solman and 6  systems to be monitored.
    I had the following queries.
    1. What are the prerequiste of the wily introscope.
    2. Do we need SMD implemented on the systems to install wily.
    3. If SMD is required pls let me know the prerequisite of SMD.
    I have already gone through CA Wily 8.0 installation guide on SMP. I was not able to find the prerequisite.
    Looking forward for your guidance.
    Cheers!
    Sammy

    Hi
    1. Refer http://www.sap2048.com/wily-introscope-installation-for-sap-customers-17.htm
    2. Yes, preferred.
    3. You may need to patch the SMD agent for wily8.0. As for the SMD agent itself, there is no requirement other that 1GB of space. It is available in all standard SAPINST.
    Cheer!!
    Javed

  • How to IMPLE SMD/Wily?

    Hi
    Need some information
    1.what are the OSS Notes which say SMD is required for  troubleshooting for SAP components like, PI 7.1, Netweaverr 7.1, Netweaver 7.0 or any specific component like AS Java 7.0 troubleshooting.
    2.How to findout which version  installed in my system of Wily introscope and SMD agent ?
    3. What is the latest version of Wily introscope and SMD agent available. Does any of the installed SAP components(PI 7.1, BI 7.0,   BIA 7.0, MDM 7.1(forthcoming)) require a upgraded version of Wily/SMD agent?
    4.what  special requirements for the new version of the SMD/Wily?
    Regards,
    Neni

    Hi
    Have you refered
    https://websmp210.sap-ag.de/~sapidb/011000358700000048292009F/
    This got almost everthing
    Also refer to : https://websmp110.sap-ag.de/support and Solution Manager Coloum for more informaton.
    Cheers
    Deepanshu

  • Solman SMD setup

    Hi,
    We have upgraded our solman 7.0 to EHP1, we did not make use of solman functionality so decided to bring in various functionalities like E2E, wily, RCA etc.,
    Being naive to this area I am in need of clarifications to my doubts...
    1. Does SOLMAN_SETUP would install, setup everything I need to run E2E, wily, RCA?
    2. Does SOLMAN_SETUP covers all the steps which can be done from http://<>:<>/smd/admin or both are different?
    3. is SMD and RCA both same
    Finally we want to implement wily, RCA from our very fresh Solman in our landscape.
    Kindly put me in right track to accomplish my work. Thanks in advance,
    Regards,
    Brahmeshwar.

    hi,
    SMD agent need to install on satellite systems like ECC, BI, PI, EP etc (single or dual stack) and configure agents on solman system.. Once you configure those agents, you would be able to configure the RCA through workcenter and below are the benefits of using solution manager with latest EHP installation.. Wily is a add-on tool and better to install on seperate machine and configure on solman
    SMD is used to carry out centralized analysis and monitoring of the SAP Netweaver system landscape. It helps to simplify the task associated with root cause analysis.
    Architecturally, the SMD is made up of four (4) main components namely:
    SAP Web AS ABAP
    SAP Web AS Java
    Willy Introscope: Used for performance analysis and optimization. The server component is called introscope enterprise server while the client is called introscope agent.
    The capabilities of SMD includes:
    Central log viewer
    Central display of configuration data
    HTTP analysis
    Single activity trace
    Java thread dump
    Database monitoring
    OS monitoring
    CCMS monitoring
    Statistics data monitoring
    Software changes documentation
    Load test with mercury load runner (used for unit, regression testing)
    CCMS monitoring
    Performance Optimization
    Thanks
    Suresh

  • Wily Introscope Agent does not start

    Hi,
    i am installing Solution Manager Diagnostics on a Solution Manger 7.0 System. At the moment i am on the point to install the Wily Introscop Agent and i have following problem:
    At first i tried the automatic setup and deployed the agent with JSPM and it seemed to work. I see "ISAGENT" on the System Information -> All Compontents over http://0/smd/admin and there is no log directory in the wily directory?
    Does anybody has an idea whats wrong?
    Best Regards,
    Stefan
    Edited by: Stefan on Feb 17, 2009 8:57 AM
    Edited by: Stefan on Feb 17, 2009 9:31 AM

    Hello Stephan,
    1. Wily IS Agent (2 agents) is installed ONLY in SOLMAN system.
    2. Then, with SOLMAN_SETUP Guided procedure, in third phase (Managed System Configuration),
        you deploy the Wily IS Agent to your managed system.
    To summarize :
    1. Install the ISAGENTxxx.SCA in SOLMAN only !
    2. Start the SOLMAN_SETUP guided procedure
    3. Phase I - Initial Configuration
        Phase II - Basis Configuration
        Phase III - Managed System Configuration.
    In Phase III, there are 6 steps :
    1.     Connect Managed system
    2.     Check Prerequisites
    3.     Manual Configuration
    4.     Diagnostics Configuration
    5.     Wily Introscope Configuration
    6.     Create Logical Components
    The Wily IS Agent (2 agents : IS Agent wich monitored JAVA instance and Wily Host-level Agent which a sub-process of the SMD Agent) is configured and STARTED here.
    So, you cannot start / stop by any OS command the Wily IS Agent.
    You start it from SMD.
    Hope it help you.
    Best regards
    Pascal Cuennet

  • Problem Remote Deploy Wily Introscope Agent

    Hi,
    I installed Wily Introscope EM and the Diagnostic Agent on Solution Manager (EhP1).
    Now, if I understand it, I can do a remote deploy of Introscope Agent, for example on Enterprise Portal.
    How can I do?
    Best Regards.
    Diego.

    Hi Diego,
    Do you also install an SMD agent on the portal system which one you want to managed via RCA? Also you need to run the Setup Wizard for Managed Systems for your portal.
    Please check SAP Note 1365123 - Installation of Diagnostics Agents. In this note you will find an attachment Agent_Installation_Strategy.ppt - describe the installation strategy of SMD agents and all agent rules which you need to follow.
    So one part is to get RCA running:
    1. Install a SMD agent per managed host.
    2. Define the technical system in SMSY Normal you have an SLD in your landscape and connect the Solution Manager to it or use the SLD from Solution Manager. After you define the technical system in SMSY or via SOLMAN_SETUP ->Managed System Configuration you go to Diagnostics Setup.
    3. You access this via Diagnostics work center or direct link http://solman_fqdn:<port>/smd
    4. Next go to Managed System -> Setup Wizard -> Select your to managed system <SID> - > check that system is Diagnostics Relevant (if not click on the managed products and set the relevant product for diagnostic u2013 also verify the Landscape setting light are green u2013 this means the technical system is well defined in SMSY)
    5. Click Setup <SID> Button -> on next screen you need to fill out all Java / Abap connection parameters (for the setup of Java systems you need a userid with j2ee admin rights)
    6. Please set the SMD agent in the right table u2013> Click on details arrow and then select the managed systemu2019s SMD agent and click on the set button. The SMD agent will now reboot wait until the agent is back -> Click on the Refresh button to see the status.
    7. Click Next and on the next screen you get a Summary of all setup steps
    8. Click on Setup. After the setup finished (all steps are green)
    9. Click on quit.
    Before your can deploy the IS agent from the Solution Manager you need to deploy the IS agent files via SDM to the Solution Manager. You can download the deployable IS agent from SAP Service Market Place:
    Support Packages and Patches -> Entry by Application Group -> SAP Technology Components -> SAP SOLUTION MANAGER -> SAP SOLUTION MANAGER 7.0 EHP 1 -> Entry by Components -> Agents for managed systems -> select your version for your IS EM and download the deployable agent via SolMan Diagnostics (File name like ISAGENTSMD801_01-10007435.SCA)
    Now you can start with the setup of the Introscope Agent (on the left menu bar under application selection).
    On the selection screen select first your IS Enterprise Manager then the IS Agent settings the relevant system.
    In the table select the J2EE node for which want you setup the agent (this need to be done for each Server node u2013 the IS agent runs inside of the J2EE node per server)
    Then click on Setup Introscope Agent u2026 Button u2013> select the Autoprobe Directives and click the Apply button. If every steps doen you need to reboot your managed JAVA system.
    Now you are ready to use the RCA tools and also see data in the IS Enterprise Manager.

Maybe you are looking for

  • Should I buy a Macbook Pro or the New iMac 21'. I have the new iPad and an iPhone 4.

    I need to buy a new computer soon and obviously im buying a mac. im not sure which mac I should buy. Im undecided between the new iMac or the Macbook Pro 13. Please help.

  • Problem connecting my 3rd gen Nano after iTunes 8.0 upgrade

    Hi. I just downloaded iTunes 8.0 and now when I connect my iPod it gives me an error message that says, "the sofware you are installing for this ardward has not passed windows logo testing to verify its comapability. continuing your installation of t

  • ME28 New Column to be added

    I am looking for a way to add a column to the report ME28 (RM06EF00).  I have a custom field that I added to the PO header (EKKO) and I would like this field to be available to be displayed when ME28 is run.  Is there a BADI that I can do this in?  O

  • Iphone 3GS shuts down abruptly

    My iPhone 3GS was shutting down abruptly. It had iOS 3.1.3, i thought a software update might fix the issue. But even after upgrade to iOS 4.3.3, i am still facing the same issue. Hard reset does not help. Any help is appreciated.

  • J1iv script name

    hi all plz help for find name of script which is use in J1IV t.code?