Solve This We have tried this for a month with no answer even from National Instrument​s Tech Support

We have the following devices
*9411
*9215
We
are trying to Trigger an acquisation on 9215 on  every Rising and
Falling edge  picked up by 9411.The 9411 Picks up pulses from an
encoder which works at 180PPR.So when we have rising and falling edges
per channel we will have 180*2 that is 360 count.Can this be achieved
if so How can this be done in VB6 or C.
All the best
Message Edited by Parikshit on 02-21-2008 11:01 PM

Hi,
Please do not cross-post the same question in different forums: a lot people consider that rude Internet etiquette. We'll continue in this thread:
Solve this it's a challenge
http://forums.ni.com/ni/board/message?board.id=70&​message.id=8224
Joe Friedchicken
NI VirtualBench Application Software
Get with your fellow hardware users :: [ NI's VirtualBench User Group ]
Get with your fellow OS users :: [ NI's Linux User Group ] [ NI's OS X User Group ]
Get with your fellow developers :: [ NI's DAQmx Base User Group ] [ NI's DDK User Group ]
Senior Software Engineer :: Multifunction Instruments Applications Group
Software Engineer :: Measurements RLP Group (until Mar 2014)
Applications Engineer :: High Speed Product Group (until Sep 2008)

Similar Messages

Maybe you are looking for

  • Web module not working

    Hello everyone, after some time working with Lr it wanted to try the web module. But on my main computer it wont load, if I try to switch, a message box appears that an error occured. In the console I find this entry: 2007-08-06 23:55:28.468 Adobe Li

  • Missing Files

    I run PrPro CS 4 on Windows XP (after the system crashed too often on VISTA), but admit that I have still to install the latest updates (which might have a fix for my problem). When opening an exisiting project, it happens at times that a window appe

  • User specific default variant in  a selectio screen

    Is it possible to provide an option to create user specific default variant in a selection screen? I have developed a custom report program. Now I want to allow users to choose one of their variants as default variant ?  Please help.

  • Doubt in alv layout variant.

    hi experts, I have a requirement that my selection screen should have 'ALV LAYOUT' as one of my parameter. I am using PNPCE LDB , now my issue is I can get the layout option when f4 is press on the alv layout parameter but the respective layout is no

  • OIM-How can i set a password policy which does not contain any space?

    How can i set a password policy which does not contain any space? I put space at Characters not allowed but it is not working. Can anyone help me out?