Sony xc hr50 and pci 1409, snap ok with max 4.0 but nothing with labview

Good morning folks,
I have a problem snaping or grabbing image through Labview 8.0 using the analog ccd camera xchr50 from sony.
I installed the pci 1409 correctly and am able to configure the camera, and snap or grab image from it through MAX 4.0.
But when it comes to try to snap or grab within my Labview interface, i just come up with an error message saying :
error 1074397153 occured at imaq snap.vi
ni imaq cannot detect recognizable video source
I can't figure out why this error comes out and how to correct it although i can do the same acquisition through max and it goes perfectly well..
I tried with another camera, same thing.
Has someone ever had that kind of problem?

Hello, Gegurissi
There are a couple of sources available from NI pages for troubleshooting your XC-HR50.
Using the Sony XC-HR50 Camera in Asynchronous Reset Mode With the IMAQ 1409
http://zone.ni.com/devzone/conceptd.nsf/webmain/e4187ea9d216f71d86256c0f0068fb7d
Using the Sony XC-HR50 Camera in Asynchronous Reset Mode With the IMAQ 1409
http://sine.ni.com/apps/we/niepd_web_display.display_epd4?p_guid=B45EACE3E24B56A4E034080020E74861&p_node=DZ52489&p_source=External
Please take a look at the document and the sample program attached to the page.
If you still have a problem, please let us know.
S.Kazuma
Application Engineer
National Instruments Japan