Source system settings DB Connect

trying to change the IP settings for source system get message
:Source system default settings are maximun values; input adjusted..
Source system is DB connect, any idea how can change settings?
It is correctly in BW : sbiw and spro set to correct level of 50 000.
But somehow the IP says the settings max is 5 000.
I need to increase this level as I have 10m records to load. .
Please asssit.
Thanks

Follow OSS note 931226 for DBConnect datasource related packetsize setting.

Similar Messages

  • Source system error - RFC connection failed

    Hi Gurus,
                  I have installed ECC6 on my PC but not when i am trying to created the DS its not allowing me its saying appl comp hierarchy for source susyem "T90*" doesnt not exist.
    so tried going to source system -> done a check for my source system then i got the following errors
    Source system "T90*" is inactive
    Entry in outbound table not found
    Entry in inbound  table not found
    Basic type does not exist
    Check failed for RFC connection T90CLNT090 ; check destination
    can any one tell me how to fix this issue?
    Regards,
    Ravi

    Hi Ravi,
                Did you run appication component hierarchy in source system(TX-RSA9)
    then activate your data source
    then replicate in BW system.
    Check here for BW connectivity with source system.
    https://www.sdn.sap.com/irj/scn/wiki?path=/display/bi/stepbyStepBusinessIntelligence
    Thanks,
    Vijay.

  • Source system settings to transfer data from GTS system to BI

    Hi Friends,
    I am trying to trnasfer data from GTS system to BI through the BCT datasources 0SLL_CD_1; 0SLL_CD_2 & 0SLL_CD_3. I am getting an error ""No document type for transmitting data into BW - Message no. /SAPSLL/CORE503".
    Could you please tell me what are SPRO settings to be done to activate the document types inorder to transfer data to BI system.
    Thanks,
    Neel

    Hi,
    Even I am facing the same problem...did you get a solution for this. ?
    Gopi

  • Source System from DB connect map to BI contents

    Hi all,
    have anyone tried to map data from DB connect to available data sources in BI contents?
    for example:
    we have a Protean ERP. we want to implement SAP BI on its database. so we use DB connect. But we want to take advantage from SAP BI Contents (exp: cubes, queries, web template,...).
    1. Can we do that? if yes, please show me the high level steps.
    2. mapping like this is better than we create our own objects, right?
    Regards,
    Chuong Hoang

    You can map a new DBConnect datasource to a current infosource.  However, you cannot map a DBConnect datasource to an R/3 (dor any other for that matter) datasource. 
    If you map to an existing infosource, make sure your info object keys are filled appropriately and any ODS keys are correctly filled.   Also, if you are not pulling in data for an info object, do not map it or else you, will overwrite data with nulls.
    Brian

  • Connection between Source Systems and BW

    Hello,
    I´m trying to connect our SAP BI 7.0 system to SAP R/3.
    At the following link, the topics for connecting BW with SAP source systems aren´t mentioned in detail:
    http://help.sap.com/saphelp_dm40/helpdata/en/00/dc54384ac9a81be10000009b38f8cf/frameset.htm
    I already have setup and tested the RFC-connections, so I primarly need a step by step description for the ALE settings (Partner profiles,Port, IDoc types,IDoc segments) in the
    context of BW-SAP R/3 connectivity.
    Thank you for your postings
    Best regards
    Mehmet

    Hi Srini,
    Thank you for you´re answer.
    I have checked  WE20 and W21. The ports and the partner profiles are created automaticly in BW and R/3 sides, when creating the new source system in RSA1.
    The main problem is, that the R/3 can´t send data to BW, although the ALE and RFC configurations are setup properly. After I replicated and activated several data sources in BW succesfully, I´m requesting data from the R/3 system with an infopackage, but after a few hours the follwing failure message occurs in the monitor :
    Errors while sending packages from OLTP to BI
    Diagnosis
    No IDocs could be sent to BI using RFC.
    System Response
    There are IDocs in the source system ALE outbox that did not arrive in the ALE inbox of BI.
    Further analysis:
    Check the TRFC log.
    You can access this log using the wizard or the menu path "Environment -> Transact. RFC -> In source system".
    Error handling:
    If the TRFC is incorrect, check whether the source system is fully connected to BI. In particular, check the authorizations of the background user in the source system.
    In the TRFC (SM58) log in R/3 there appears an status text with the following entry:
    "No service for system SAPABC client 123 in the integration directory".
    For this entry I have found the SAPnote 940313. In this note,there is described how to send Idocs over Integration Server. Now I think that our R/3 system tries to send Idocs over the Integration server too.
    But is there another alternative to send Idocs from R/3 to BW without using the Integration server?
    Best regards
    Mehmet

  • Connecting to R/3 source system from BI in ECC6.0

    Hi all,
    We have installed ECC6.0 system recently with two clients say 500 for R/3 and 600 for BI7.0.
    we would like to know how to establish connection between these two clients?from BI7.0 >RSA1>Source Systems-->we do not have any source system assigned here(i.e. SAP folder has nothing under it).
    Does anyone has documents on this?please share with me.
    Regards,
    Murali.

    Hi Murali,
    Following are the stpes to be performed
    1)Before any developments create a user ALEREMOTE through transaction code SU01. This user name is to be created in both the BI system and the R/3 system
    Enter the requisite details for the same like address, Logon date, defaults, parameters, roles, profiles, groups, personalization and license data. Remember to assign the SAP_ALL and R_RS_ALL in the profiles
    You can create the system-generated password by clicking the wizard button.You can also choose the password of your choice. It’s important to note that keep the password same for the user ALEREMOTE common for both the BI and the R/3 system.
    2) In the same way create another user BWREMO
    3) Define the logical system in BI
    Click on SAP reference IMG in SPRO Transaction
    For BI 7.0 the procedure is different. It is as follows. Click on SAP Netweaver Business intelligence Links to other source system General connection settings, then click on define logical systems.
    For the earlier version BW 3.5 and earlier follow the following steps. Then drop down the BW customizing implementation guide. After that Business Information Warehouse Link to other systems  General connection settings then click on Define logical systems
    Click on new entries and enter the logical system name and description
    Press the New entries button
    Enter the client, city, logical system name, currency, and client role. Select the radio button automatic recording of changes and the rest will remain the same. After that click on save and then back and then save again.
    4) Define logical system in SAP R/3 in similar way
    5)Go to R/3 connection in BW 3.5 or go to ABAP connection in BI 7.0. Then click create.
    6)Now create two RFC destinations for BI, one for direct remote login and the other through the Dialog screen.
    7Creating RFC destination for BIW.
    a.     Create a RFC destination NB1CLNT500 with the name for logical systems. The other destination would This destination would be used for BW  BW interaction. The same would be for theNB1CLNT500_DIALOG.Now click on connection test and there should not be any error. Now check by clicking the Remote Login button and this will take you to the R/3 system.
    8.     Creating RFC destination for Dialog
    a.     Create a RFC destination with the name of and NB1CLNT500_DIALOG in BIW with the name for logical systems. This destination would be used for BW  SAP interaction.
    9.     The process is finished now.
    10.     Now your connectivity is successfully established with the R/3 system.
    Please assign points if this helps
    Thank you,
    Regards,
    Senoy

  • Display Datasource in Source System -- connects to Production ERP

    Hello,
    We have performed a System Copy of BI Prod. In the copied system on one of the Generic DataSource (ZBIP_VKDFSEXT) when I right click and say "Display Datasource in Source System", it is connecting to Production ERP, supposedly it must be connecting to Dev ERP.
    I have tested RFC COnnections and Logical System Settings in WE20 and 21, but they are pointing to DEV ERP.
    Correct replies appreciated.
    Thanks
    SM
    Edited by: SM on Jul 9, 2011 5:32 AM

    Dear SM,
    I guess we have faced same kind of issue earlier,
    at that time we just removed RFC connection between production system because we are not using Production system connection any more.
    and then just clicked on connection parameter of source-system, there we defined new RFC destination.
    Hope it will solve your issue.
    Regards,
    Ashish

  • Source system connection issues

    Hello BI Experts,
    We had issues with the source system connection - from our BI system (NW 04s) to our R/3 system (ECC 6.0) .
    From RSA1, when we right click on the R3 source sytem and do a "Check", it was erroring out: "Error in source system <Logsysname1>". This Logsysname1 was different one from the actual R/3 system's Logsys name (Logsysname2) .
    To Fix this, we restored the connection by selecting the (R/3) Source system and right click and "Restore".
    After providing the passwords for the RFC users, the system again asked "The Connection <XY> is used in the <Logsysname1> Source system as a connection." And we selected the "Delete" option here. Then in the Logon screen to R/3, we provided the administrator user Id and password.
    Once the source system connection is complete, we checked the connection as mentioned above and the "Source Sytem connection is OK" now.
    (1) But now, in the transaction RSA1, the R/3 system is displayed under "BI" instead of "SAP".
    (2) When we asked our BI consultant to check the dataloads, he encountered an error: "No transfer structure is available for InfoSource <X> in the Source system. Errors in Source system".
    How can we bring the R/3 system under "SAP" now?
    If we delete the R/3 system (which is listed under BI) and recreate under "SAP", will the transfer rules will also get deleted?? How to avoid this issue?
    Please advise.
    John
    SAP Basis.

    Hi,
    Please make sure that you have followed the below steps while creating the Source System
    1.     In the initial screen of the source system, choose Tools ® Administration ® User Maintenance ® Users and create a background user with a password and the authorization profile S_BI-WX_RFC.
    2.     Define the RFC destination parameters for the SAP source system in BW. To do this, choose Tools ® Administration ® Administration ® Network ® RFC Destinations in BW.
    Enter the information taken from the source system on the server name.
    u2022     Application server: pswdf090
    u2022     System ID: IDF
    u2022     System number: 90
    The destination name has to correspond to the logical name of the source system that you entered for the process step Define Logical System in the implementation guide for the source system. For user and password, enter the background user that you created in step 1.
    3.     Define the RFC destination parameters for the SAP BW in the source system. To do this, select Tools ® Administration ® Administration ® Network ® RFC Destinations in the source system. Enter the server name information taken from the BW system.
    The destination name has to correspond to the logical name of the BW system that you entered in the process step Define Logical System in the BW Customizing Implementation Guide. ALE communicates using the name of the SAP Business Information Warehouse that you defined. The defined name represents how the SAP Business Information Warehouse is identified. For the user and password, enter the background user that you defined in the BW Customizing Implementation Guide under Business Information Warehouse ® Links to Other Systems ® Link Between SAP Systems and BW.
    4.     Test both RFC destinations with the functions Test ® Connection and Test ® Authorization.
    If an error occurs during the authorization check, the background user is not permitted in this client and with this password. If an error occurs in the connection test, it means there is a network problem.
    5.     In the BW Administrator Workbench choose SOURCESYSTEMTREE ® Root ® Context Menu (right mouse button) ®Create and select the radio button for the manually creating an SAP source system.
    6.     Enter a description for the source system and the logical name of the source system that you entered for the process step Maintain Logical System in the source system implementation guide.
    If you still have any issues, let us know.
    Regards,
    Yogesh.

  • Issue in while connecting Source system

    Hi All,
    I mistakenly Ran the function module RSAP_BIW_DISCONNECT in BIW, I suppose to run this FM in Source system side,
    We observed that Source system in RSA1 (BI) has been deleted), and also one record from the table RSBASIDOC (which is from source connection) has been deleted .
    When I try to create he source system in BI, after entering logical system and ALEREMOTE and BWUSER logins, it was asking me to login to source system, after entering the details,
    A pop-up message:
    RFC destination already exists in source system
    Do you want to use this destination, check, or
    cancel source system connection?
    options: USE, CHECK and Cancel, -> We pressed USE
    Then it came back to RSA1 screen and a pop-up message
    Connection BA is used in the ERQXXXX
    source system as a connection BWQXXXX to BW.
    Do you want to delete this connection in the source system?
    Connection Is Restored After It Has Been Deleted Successfully
    Options: Delete, Do not delete.
    When we go for Delete : It is saying that "Error in source system ERQXXXXX"
    Thanks in Advance,
    Teena

    Hi,
    Please find the link which might help you:
    http://help.sap.com/saphelp_nw70/helpdata/EN/00/dc54384ac9a81be10000009b38f8cf/frameset.htm
    Best Regards,
    rajani

  • Connect two BW systems to one source system

    Hi Experts!
    I would like to know if I can set up two BW systems connect to one source system.  We copied and built new BW system (BW2) from existing BW system (BW1).  We need to have both system connect to one source system.  When I execut Restore from BW2 - RSA1 - Source System, I'm getting a following prompt:
    "Connection cannot be used. The connection BB is used in the DEV400 source system as a connection BW1400 to BW. Do you want to delete this connection in source system".
    If I select "Delete" then it replace exising connection between BW1 - DEV and creates new connection BW2 - DEV.  If I go back to BW1 and do restore then same thing happens as BW2 connection removed.
    Is there anyway we can set up two BW systems connection to one source system with restore?  Connection works fine since each one can connection with no issues.  Just when I do restore, it removes other connection.
    Thanks.

    Check if it helps:
    Loading two different SAP BW system from one SAP R/3

  • Connect one SAP ECC 6.0 source system to 2 SAP BW system

    Hi!
    I copied SAP BW system (e.g. BW1 --> BW2).
    My source SAP BW system "BW1" was connected to SAP source system "MM5" (tcode RSA1).
    Now I would like to connect my new SAP BW system "BW2" also to this SAP source system "MM5".
    When I do so I get the following error:
    Connection cannot be used.
    Connection BA is used in the MM5:400
    source system as a connection BW1CLNT001 to BW
    Do you want to delete this connection in the source system?
    Question:
    Can one SAP ECC system be connected to 2 SAP BW system?
    If yes, what are the steps to do this?
    Thank you!

    Thank you very much!
    The question still is how to proceed with the following dialog screen/warning?
    Connection cannot be used.
    Connection BA is used in the MM5:400
    source system as a connection BW1CLNT001 to BW
    Do you want to delete this connection in the source system?
    YES or NO
    Thank you!

  • Connection of 1 source system to 2 Target system

    HI ,
    We are in the midst of upgrading the hardware for our BW box.
    At present old box is as follow:
    1)BWQ connected to source QAS
    2)BWP connected to source PRD
    The new box is called FWP. We are testing on the new FWP by establishing connection of FWP with source system QAS.
    This mean, source system QAS is connected to 2 boxes at the same time.
    old BWQ-QAS
    new FWP-QAS
    I would like to know if we perform data load in new FWP, what will the impact be. Will that impact the delta queue in source system QAS? If i trigger load in FWP, does that mean we will loose the delta whn data is triggered in BWQ?
    Regards,
    Maili

    Hi,
    Since itu2019s a new box this will not impact to old box, but we need to develop everything from start in new box or you can copy from the Old.
    We also have something like it.
    Check the below link which will help you.
    Re: Replicating data sources during upgrade of Source system
    Hope it Helps..
    Edited by: Rakesh BI on Apr 26, 2011 10:03 PM

  • Source system moved to differnt folder in RSA1

    Hi,
    We did system refresh from R/3 production to R/3 Quality system.
    After this, as a part of post refresh activities, we did restore source system connection in RSA1 of BI Quality system by
    right click on R/3 Quality system and choosing the option Restore.
    It asked us user id and passwords for aleremote and extremote users ( background users for BW and R/3 quality ).We provided those.
    Then it asked us to provide the userid and password for administrator for R/3 quality system.
    We provided user id and password of DDIC user in R/3 Quality system.
    Then it gave the following message:
    User already exists in source syst. Only continue if profile and password are correct.
    Continue? or Cancel?
    We selected "Continue".
    Then it gave us the screen with following message:
    RFC destination already exists in source system .Do you want to use this destination, check, or cancel source system connection?
    Use ? Check? Cancel?
    We selected "Use"
    Then it gave us the following message :
    Connection BB is used in the R3QCLNT100 source system as a connection BQ1CLNT100 to BW.
    Do you want to delete this connection in the source system? Connection Is Restored After It Has Been Deleted Successfully.
    Delete ? or Do not Delete?
    We selected Delete.
    After this, restore took place successfully but there is one problem.
    After restore, in RSA1, Source system R3QCLNT100 ( source system name for our R/3 quality system ) is shifted from the folder SAP ( source system type for SAP source system ) to Folder BI ( source system type for BI system )
    Please suggest how to shift the source system from BI to SAP Folder.
    Thanks,
    Tarun Brijwani.

    Hi Tarun,
    have you checked RFC connection before you did Restore?
    Might be that you need to adjust RFC settings (TA SM59) for that particular source system.
    Seems to me that IP of your R/3 QAS system is pointing into some BW system. That's why your source system was shifted under BI source systems in TA RSA1.
    BR
    m./

  • Creating source system: No entry for BW_USER in table RSADMIN available

    Hi,
    When i try to create source system in RSA1, when I choose SAP system from Release 3.0E (Automatic creation), I get this message:
    No entry for BW_USER in table RSADMIN available.
    What do I have to do to create source system.
    RFC connection are already made.
    Best regards,
    Uros

    hi Uros,
    you need to maintain ale user,
    rsa1->settings->global settings->glob settings
    enter bw user ale. normally ALEREMOTE is used.
    oss note 410952
    Symptom
    You receive the error message when trying to connect a source system to the Admininistrator Workbench:
    "No entry for BW_USER in table RSADMIN exists" (message number RSAR 059).
    Additional key words
    RSAR059, APO, RSADMINA
    Cause and prerequisites
    In table RSADMINA, the BW user is not maintained for ALE.
    Solution
    Maintain the entry using the following path:
    Call Administrator workbench (transaction RSA1).
    From the 'Settings' menu, select Global Settings'.
    If an entry already exists in the field "BW user for ALE", delete this.
    Enter the correct names for the BW users in this field.
    Save the entry.
    You must restart the Administrator Workbench (RSA1) now.
    The source system can now be linked without errors.
    hope this helps.

  • Table does not exist in system after DB Connect

    Hi Everyone,
    I must extract data from a oracle db.  I create a source system with DB Connect and it's connect successful.
    Later, i create a datasource for that source system. but it show the table does not exist in system. I'm sure the table is correct. why?
    Thanks!

    Check the schema names & ensure it is with the same owner/name as in the DB source table/view. You can also use a simple lookup table which checks table/views in your schema from other standard tables.

Maybe you are looking for

  • Ipad as Universal Remote

    Hi, I just bought a 32gb Ipad and intend to use it also as a Universal Remote for my home theatre. Does someone know or recommend any good and trustworthy app or accessories for this mean? Thanks, Gus

  • Problem accessing account after update

    After updating my ipod, i can no longer access my itunes account. Why?

  • ZRS Cool Solutions Report

    We have uploaded a Cool Solutions report entitled 'Licensed Products Allocation' to our ZRS, and I am getting an error message ('Error executing SQL statement for : report3 ORA-01858: a non-numeric character was found where a numeric was expected').

  • Problem with trial install of photoshop c6

    I receive an error message everytime i try to install photoshop CS6 it tells me to 1. restart my computer 2. Exist firewall and other applications 3. Relaunch again. I have tried this three times. does anyone know how to get this to work? it is almos

  • I'm having a problem getting my pop ups in CS6 InDesign to work when I export to Acrobat.

    I am creating pop ups in a CS6 InDesign Interactive design and when I export the file to Acrobat the pop ups will not work. They work on the 1st page onlybut not in any other page in the interactive piece. I started this document in CS5 and then conv