SPA 2102 config question

Hi,
I have above sipura above and want to configure 2 accounts to 1 port - is this possible or is there a way to get round this problem?
I have an adsl device that allows you to configure 4 voip accounts and give an option of which port to ring when incoming call. My ISP has changed hands and they don't allow you to use your own modem.
Thanks in advance.

The SPA2102 has 2 voice ports, 1 account per port is supported.

Similar Messages

  • SPA 2102 Config

    I have some pretty basic questions I could use some help with:
    I'm on Hyperdog VOIP,Comcast Cable with a SPA 2102. No other router.
    Why when I dial 110# to check the phone IP do I get 76.123.3.245, shouldn't it be 192.168.1.100? The only way I can get into the configuration pages is to put 192.168.1.1 into the browser.
    Listed as default gateway on config IP. Does that matter?
    My basic problem is choppy calls. No dropped calls, just poor quality. Are there some basic things I should be checking in the configuration?
    I've run speed test multiple times:
    Download varies a lot. Normally it's in the low 700s but I've seen them at 600 and as slow as 335
    Upload stays pretty steady at about 327-345.
    Latency is 311-315.
    I loaded the latest firmware (5.2.5) and changed the freq on the cordless phone which helped. I saw no great improvement when I went with a corded phone.
    Any advice?
    Thanks.
    Message Edited by rjfoy on 02-22-2008 05:46 AM

    Hello rjfoy,
    300+ms latency is bad. If this latency is even unstable (jitter) this WILL cause very choppy calls.
    In the SPA config, try to setup Network Jitter Buffer to something like "Extra large" to compensate as much as possible. Anyway, with this latency PLUS big Jitter Buffer the calls are like to be like transmission to the moon - the other party will hear you with (likely 1s or so) delay.
    Just a question - who hear choppy sound - you, the other party, or both of you are having the problems ?

  • SPA 2102 - Firmware upgrade

    I recently bought an SPA 2102.  Of course it is unlocked (I have full access to user and admin).  The Software Version is 3.3.6.  The Hardware Version is 1.2.5(a).  Everything is working fine.   I went to www.linksys.com to upgrade the firmware.  I noticed that current firmware is 5.1.9 dated 04/03/2007.  I was a little bit surprised with the huge gap between the current 3.3.6 in my SPA 2102 and the 5.1.9 posted on Linksys website as I bought my SPA 2102 a month ago.  Nevertheless, I tried to update the firmware I provide the IP address for my SPA (the same one I use to gain access to the setting webpage).  However I received a message “upgrade fail: No response from SPA”.
    I have a feeling that my SPA is a SPA 2100 disguised in SPA 2102.  When I went to SIPURA website, I found that the latest firmware for SPA 2100 is 3.3.6.  The way I understand it is the SPA 2100 is phasing out and replaced by SPA 2102.  I will be concerned that I will have a sort of a phased out device.
    I called Linksys technical support and they were slightly above useless.  The guy told me to contact my VoIP provider to upgrade the firmware.  I told him I have no VoIP provider as the ATA is unlocked.  He put me on hold for long time until the call got disconnected.  Usually I don’t count on telephone technical support.  Anyhow this is not the issue.  
    Here are my questions:
    1)      Did I miss something that prevented the upgrade of SPA 2102 to the 5.1.9 firmware?  What settings I should look for to allow the firmware upgrade?
    2)      Should I upgrade my SPA 2102 to the 5.1.9 or I am considered part of the SPA 2100 family rather than the SPA 2102?
    3)      If I am actually an SPA 2100 in a SPA 2102 box, will I damage my hardware or make it functionless if I upgrade to 5.1.9?

    Krishna, this worked for me. I just connected my computer directly to the LAN/Ethernet port of the SPA-2102 and run the firmware upgrade executable file. I initially had the same problem since my computer was connected to the main router.

  • SPA-2102 Setup issues

    Hi all,
    I bought the above linksys device and have been trying to set it up with Voipbuster. My current setup is
    Thomson 585 (locked by ISP O2) -> Lan port 3 on Thomson has the SPA-2102 connected to it.
    I get no dial tone at all, but when going on the setup page on the 2102 it says registered against Line 1 for Voipbuster.
    I have forwarded port 5060 from the router for the 2102.
    Any ideas what to check? I'm completely lost with the amount of config options presented to me by the 2102
    Many thanks

    Hi,
    the phone I'm currently using is a DECT phone cordless. Cable used has all 4 cables in the plug. I tried with a cable that only has the 2 middle ones and there was nothing, not even noise.
    I'm surprised you say that the 2102 only uses the 2 wires in the plug as I can see that it has 4 "pins" in the plug on the device.
    Also I do get a response from the IVR with the current cable, just no dial tone and only noise/echoing
    Message Edited by FZS on 11-20-2008 12:48 AM

  • A few post config questions on new setup

    Hi Group,
    Just a few post config questions.
    First, how can I confirm my controller is in fact associating properly with an NTP server?  On a typically cisco product, I could just do a 'show ntp associations' or a 'show ntp status'.  I cannot see a way to confirm this on the gui or command line.
    Second, on my guest network with web-auth, if one were to choose to not use https for web-auth and instead use unsecure http, would that be possible and if so where in the gui?
    Thanks.

    The third field is from a WLC running v7.4 not v7.2.  I usually would install a 3rd party certificate, but what eles you can try is issue this command on from the CLI.  It had issues working with certain code versions, but you might as well give it a try.
    config network web-auth secureweb disable
    Thanks,
    Scott
    Help out other by using the rating system and marking answered questions as "Answered"

  • I'd appreciate any help setting up my SPA 2102 w/ my D_Link wireless DIR 601

    hello all 
    Not sure if this has been addressed before...
    i found this link but my setup is slightly different. 
     http://forums.linksysbycisco.com/linksys/board/message?message.uid=227491&comm_cc=US&comm_lang=en
    presently,  I have a dry loop phone line---> speedtouch DSL modem---> D-Link DIR-601 and the LAN 1 going out 2 the main computer  and LAN 2 going out 2 the SPA 2102
    I can get my D-Link system working fine w/o the SPA or I can just hook up the SPA w/o the D-Link and then both phone/internet works fine.
    Both have been registered separately using the 192.168...addy 
    but getting the Internet/VoIP/Wireless has been impossible....so far... 
    any suggestions???
    thx in advance,
    B. 
    Message Edited by MIIM on 03-27-2010 03:48 PM

    Basically you're cascading 2 routers. If that is so, you're creating double NAT network. As much as possible, it is recommended to connect the SPA2102 as a primary router because Voice requires more bandwidth.
    This should be your network setup: DSL Modem - to the WAN port of SPA2102 - to the WAN port of the Dlink router.
    If I'm not mistaken, these 2 devices are having the same IP. Change the LAN IP of the Dlink router from 192.168.0.1 to 192.168.1.1.

  • Workshop Weblogic config questions

    I'm using Oracle Workshop for WebLogic 10.3 and I'm hoping someone can answer some setup/config questions.
    When I double click on the server (WebLogic Server v10.3 at localhost) a window opens with various settings that manage how workshop and weblogic work together.
    Under "Startup & Deployment" I have the following turned on:
    Launch WebLogic server in Eclipse console
    Always start WebLogic Server in debug mode
    Ignore project compilation errors when publishing (I have this turned on because of errors in a portal project, the errors aren't inmportant, and don't prevent the project form running)
    Run stand-alone web module directly from workspace
    So, first question, with these settings I was able to quickly switch to debug mode, with out restarting the server, now the server restarts whenever I turn debugging on. What have I done that has stopped this working correctly? How can I get it to start debugging without a full restart?
    next question, what happens if I turn on "Start WebLogic Server in Express Mode"? As far as I can tell nothing happens.
    Lastly, under "Automatic Publishing" I have it set to "Never publish automatically", if I choose another setting workshop essentially freezes because it's constantly publishing. So whenever I make a change, even in a jsp, I need to remove the project, then re-add it to see my changes in the browser. This is frustrating, not just because it takes 8 or 9 minutes (8 or 9 MINUTES!!!), but because the project doesn't run properly until it is redeployed. You'd think that if it needs to be re-deployed, then none of my changes should matter on the server until it is re-deployed.
    So, my question is, Is there any way to get this re-deployment to happen faster?
    Thanks for any and all help

    Well, in my experience performance is not bad as you experienced. Is it locally connected server or remotely connected server? If it is a remote server, network issue could cause this latency issue.
    Is performance better if you run the server without enabling debug mode? If yes, probably you can also review any break points set.
    You could also try out the following options
    1) Run workshop with -clean option, by opening command prompt and navigating to workshop_home\'workshop.exe -clean'
    2) Untick the option 'Launch WebLogic server in Eclipse console' and start server which would enable server to start on command prompt
    3) This would enable you to take multiple thread dumps (cutl +Break) on the server console output, while performance is very bad, to see where threads are halt.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                               

  • Re: PLM4P v6003 Config Question:  Any way to configure UGM Notifications?

    After reading:
    PLM4P v6003 Config Question:  Any way to configure UGM Notifications?
    This is one of the requirements from me as well. We always wanted to customize emails sent not only for UGM but also for other modules. We wanted to conveysome message to approvers. But it seems this is still not possible. Is this functionality on road-map of AgielP4P product management?

    Currently, the subject and body of emails can be customized to an extent, as they are translations that can be overridden. The translations have some placeholder fields that get populated by the system, but you are limited to those placeholder fields. The upcoming release will give you full control of the email body and subject lines, for GSM and SCRM emails, as well as Supplier Rep emails.

  • Problem with SPA 2102 (no tone/phone1 led not on)

    Dear All, We are using spa 2102 adapters, two of them are working fine, one has some problem. The phone1 led is not working i.e, the phone has no tone. if we connect the adapter to PC through Ethernet its working fine and the DHCP is assigning the IP to adapter. Kindly resolve the issue. Thanks.

    The problem is resolved!
    I called the service provider and they told me to put the IP in the DMZ or outside friewall. But i just reserved an IP in DHCP server for this device and then put that IP in the Linksys seetings page as static IP rather DHCP.
    It starts working and i was able to call and recieve calls.
    Thanks.

  • Redundant FWSM Config Question

    Hello All,
    I'm going to be configuring failover with FWSMs for our 6500 at my job and I have a config question. There is one current 6500 chassis with 2 FWSMs installed. They are both online but currently since failover isn't setup, only one FWSM is actually active. My question is since we are using mutiple contexts where do I setup the failover interface, and do I need to configure failover on every single vlan on the FWSM? We have over 10 contexts each with 2-3 interfaces on them, so do I need a failover IP for every vlan that exists on every context? Also, does the failover config get setup on the admin or system context? Any help would be greatly appreciated, and thank you so much in advance!

    Hi John.
    Failover config goes in the system context. For the data interfaces in each context, you will need a primary and a standby IP i.e. 2 IP's per VLAN. Once failover happens, the secondary FWSM will assume the active role and the secondary FWSM will take over the Primary IP address thus making the failover process transparent to end users.
    HTH.
    Regards
    Zubair

  • Random 'Duplicate Digit Dialing' on SPA-2102

    I have a Linksys VOIPAdapter SPA-2102 which worked fine for two years but started ‘duplicate digitdialing' from mid-October this year. While it is still working perfectly for callsto and from any US/Canada number, now it always dials "double digits"randomly AFTER getting connected to an international access number(403-260-3325) and then dialing 011 to connect overseas . For example, aftergetting connected if I dial 92-51-2256684 it instead dials 922512256684or 925512256684 or 992512256684 etc. Thus the problem startsafter dialing 13 digits, while the same settings worked fine earlier for twoyears.
    I have talked extensively both to my VOIP phone service provider and theInternational Dialing service provider, but both have failed to solve theproblem. The problem is not faced if I use a softphone from my computer,confirming the problem to be in the VOIP Adapter settings. I changed my phonebut that has not solved the problem. I reset the VOIP Adapter to defaultfactory settings by dialing the 73738# code from the handset and then feedingin the settings provided by my service provider (Adminlogin-Advanced-Voice-Line 1) but problem was not solved. Tried the same with877778# code but problem stayed. Downloaded the firmware from Linksys(Cisco)website and upgraded to version 5.2.10 from 3.3.5(a) but problem still there.
    Can someone help, as I amunable to dial overseas since last six weeks!

    If you tried the different combinations of DTMF Transmit Method and Codec settings you tried the obvious fixes.
    To persue further changes, I would download the latest firmware for the SPA2102, install it and re-enter your configuration.  If you are currently running the latest firmware, I would reset the firmware to factory specifications with the IVR and re-enter your configuration.  You can download the latest firmware here:
    http://www.cisco.com/cisco/web/solutions/small_business/products/firmware.html
    When you send dtmf digits using the rfc2833 protocol, for each digit the protocol sends a start digit packet, then multiple packets for the digit depending on how long you hold down the key, then an end packet.  If the packets get out of sequence or lost that's when the receiving end can get an error in decoding the digit.  The packets are sent along with the voice stream packet (rtp packets).  If you made the call with XLite using the same voip provider to call the pstn number and experienced no problems whereas you consistently experienced problems with the SPA2102 then it would seem that the firmware in the SPA2102 has some difference with the XLite computer code.  As I said, by default it appears to me the XLite is using rfc2833 as a dtmf transmission method and G711u as the codec.
    Several of the Betamax companies have competitive promotional rates to Pakistan.  VoipBuster is 3.0c/min, Rynga is 3.0c/min, Jumblo is 3.0c, 12voip is 3.5c/min, budgetsip is 3.3c/min, and actionvoip is 4.0c/min.  These are euro cent prices.  You could try one of these companies with your 2d line on the SPA2102.  The disadvantage here, though, is it costs 10 euros to get started which is close to $16 Canadian, they can change the rates without warning, and they offer zero customer support.
    You could also try a different voip provider to call the pstn number as a test to see if that made any difference.  You can get a pay-as-you-go account with CallCentric for a $5 (US) deposit.  With CallCentric, calls to a Canadian PSTN number are 0.0198 (US) per minute. 

  • SCCM 2012 application portal: config questions

    Hi,
    We have setup SCCM 2012 application portal correctly and it's working fine.
    However some config questions:
    -can we change the name of the configuration portal? Now its servername/CMApplicationCatalog ... what's not userfriendly.
    We'd like it to be applicationportal.ourcompany.com. Howto achieve that?
    -can we customize layout in a supported way (we could change html pages but after an upgrade of SCCM they would/could be erased)?
    -how does flexera (adminstudio?) plugs in into this. I've read this entry
    http://helpnet.installshield.com/appportal2014/Content/helplibrary/AP_CreatingCatItemSCCM.htm but what's the big picture here? Anybody using this? What are the advantages?
    J.
    Jan Hoedt

    We want to offer software center for overview of mandatory installs, application catalog for optional software.
    On our companies portal, we can then set a link which directs to the application portal. User can then install optional software from there.
    My current config works http://applicationportal.ourcompany.com/ goes to the sccm-server but not to the url below.
    That would be http://applicationportal.ourcompany.com/CMApplicationCatalog/#/SoftwareLibrary/AppListPageView.xaml
    how can I make sure the application portal shows up when this link is opened?
    It sounds like you want to perform a URL rewrite?
    http://www.iis.net/learn/extensions/url-rewrite-module/creating-rewrite-rules-for-the-url-rewrite-module
    You should test this to see if it's what you want - I may have misunderstood your question.
    Also, I wouldn't host this module on your AppCatalog server, I'd host the rewrite module elsewhere.
    Don
    (Please take a moment to "Vote as Helpful" and/or "Mark as Answer", where applicable.
    This helps the community, keeps the forums tidy, and recognises useful contributions. Thanks!)

  • SPA-2102 with Cisco Unified Communications Manager (callmanager)...

    Has anyone used SPA-2102 with a UCMgr or CallManager?
    If you do.... how many DLUs (device license units) do you need for each SPA-2102?

    I have tried to get the SPA2102 to register to CUCM with no luck.  However, there was another way to get them to talk.
     Setup a Cisco router with SP Services IOS as a SIP Gateway.  Build a "voice" dial-peer for incoming calls, build another for outgoing calls to the SPA2102, and another to the CUCM.
    Configure the SPA2102 to NOT register with SIP Proxy and to point to the Cisco router instead.
    This costs NO DLU's.
    Depending on how your dial-peer's are configured you can have both lines appear as the same number.or different numbers.

  • QoS on SPA 2102 using VLAN

    I'm trying to configure quality of service on a SPA 2102 using VLAN tagging.
    But using wireshark I see that the packets exiting the ATA don't have the TOS volue correctly set.
    Is possible to give different priority to Data and voice using VLAN tagging?
    Thanks
    Enrico

    I Believe the QOS Value on The SPA are set to default and Its not possible to be change. I was able to find other forum sites for the SIPURA default  values.
    SIP TOS/DiffServ Value: 0x68 
    RTP TOS/DiffServ Value: 0xb8
    ToS 0xb8 = 10111000 = 184
    (802.1p) = 101 = 5
    (DSCP) = 101110 = 64
    ToS 0x68 = 01101000 = 104
    (802.1p) = 011 = 3
    (DSCP) = 011010 = 26
    I Hope This helps

  • Phone hang up with SPA-2102

    hi...i searched for my problem but couldnt find anything so sorry if this has been posted before.
    I have a SPA2102 phone adapter with router. I set everything up and connected The ethernet cable from the adapter to my modem and from the adapter to the PC and then connected my phone line from the adapter to my phone like Im suppose to.
    however, when I use my phone, it hangs up after like 2 minutes every time. this is very frustrating as I was not able to find a similar problem by searching on the internet. since my phone keeps hanging up, its also hard to get customer support through the phone.

    At this point are you also getting intermittent internet connection? Try setting NAT Mapping Enable and NAT Keep Alive Enable as “Yes”. Ensure that you are using already the latest firmware version for the SPA-2102. Make sure as well that the bandwidth is maintained. For the codec G.711 it should maintain a 64kps bandwidth speed.

Maybe you are looking for