SPA400 FXO Ports are not dropt down after receving a call

Hi Team, does any one know why all FXO ports on a SPA400 are not disconnecting calls (there is not much configuration options to make sure we tier down ports)?
Example: I make a call and the SPA400 answer with the aa of my SPA9000 and after I hang up the line my SPA400 does not drop the call on the FXO so the line keeps busy all the time.
Please advise.

I'm looking at an older firmware version, so I'm not quiet sure if this is also available on your SPA400, under Setup then Voice tab , there's some parameter at the bottom for disconnect like , battery reversal as disconnect signal , tear down fxo port when silence detected for n seconds. Have you tried tweaking this settings? Also, on the SPA9000, you can try setting Reorder delay to 255 and see if it will help.

Similar Messages

  • HP Pavilion dv6-6b10tx two of the usb ports are not working

    I have recently bought a HP Pavilion dv6-6b10tx....and had it fixed by hp for a problem with the beeping noise.
    After sending my laptop for repairs( replacing the system board), I received my laptop but two of my usb ports are not functioning...
    I did a bios update and did the hp update to see if it actually fix anything but not luck.  So I went device manager and found a exclamation mark on the renesas electronics usb 3.0 host controller with a device status 'This device cannot start. (Code 10)'.  What do i do??

    The question is why is the port not working?  Is something in the port that you can see?  If not, then there isn't much you can do but take the computer in to the genius bar and have the techs see if it is a circuit problem that can be fixed.

  • The g, h and backspace on my keyboard are not working even after replacing with a new one.

    The g, h and backspace on my keyboard are not working even after replacing with a new one. I have also updated my BIOS still d same. Please help me ASAP.
    ...am waiting for a QIUCK RESPONSE

    How does a usb keyboard attached externally work?
    You might try a "hard reset" where you remove battery and AC charger, hold down power button 20-30 seconds and then reassemble and turn on. Reset BIOS (F10) to default settings, too. 

  • IPhone 5 facetime app not shuting down after updating of  iOS 8.0/8.0.2 ?

    Hey there my iPhone 5 face time app not shuting down after updating of  iOS 8.0/8.0.2 ? after i upadted my iOS 8.0/8.0.2 software  my facetime app never get quit even i want to quit it. so then i have to shut my fone down to quit facetime . please help me . Thanks

    Hi, gurpreet from chatham.  
    Thank you for visiting Apple Support Communities.
    Here are some troubleshooting steps that I would recommend going through when experiencing this issue.  
    iOS: Not responding 
    http://support.apple.com/kb/TS3281
    Cheers,
    Jason H.

  • Pictures are not being delivered after saying delivered on iMessage.

    Pictures are not being delivered after saying delivered on iMessage.
    Txting through iMessage works fine. Pic's won't send.
    I turned on and off everything and did all the necessary trouble shooting.
    I'm on a Verizon 4S. and I'm sure Verizon has nothing to do with iMessage system, since it's on its on server.

    bump

  • PavillionG​7-2315nr windows 7(64 bit) USB serial control or usb ports are not working. Please help!

    Hi I downgraded the laptop from windows 8 to windows 7 64 bit. Two of my USB ports are not working and cant find the right drivers for it. Can you please direct me, where I can download and update the drivers? Thanks in advance.
    Shawe

    Hi:
    Download and instal both of these drivers and reboot.
    http://h20565.www2.hp.com/hpsc/swd/public/detail?s​p4ts.oid=5229463&swItemId=ob_125616_1&swEnvOid=405​...
    http://h20565.www2.hp.com/hpsc/swd/public/detail?s​p4ts.oid=5229463&swItemId=ob_123787_1&swEnvOid=405​...

  • COM port are not shown in my applicatio​n

    Hello,
    there is a reason why com ports are not shown on a Xp Embedded Touch Panel? 
    I have to communicate through a serial port in my application but com ports are not shown in Visa Resource Name control ...
    I have included all VISA related things in additional installer ...
    Solved!
    Go to Solution.

    Ok, i checked functionality of COM ports with a non-National Instruments programs and all it's working. Only Labview apps cannot see them.
    On another PC where the Labview app works if i look at installed Programs in NATIONAL INSTRUMENTS section i can see:
    NI VISA RUN TIME 5.1.0
    NI VISA 4.5 for Labview on Windows Mobile/CE
    On the machine where there the problem under National Instruments SW i can see only:
    NI system components
    but i've added in additional installer section of the app installer all VISA related stuff...

  • Hp pavilion 1012tu usb 2.0 ports are not working

    my hp pavilion 1012tu USB 2.0 ports are not working only the 3.0 port is working

    Try this:
    http://h10025.www1.hp.com/ewfrf/wc/document?cc=us&lc=en&docname=c01893385
    or
    http://h10025.www1.hp.com/ewfrf/wc/document?cc=us&lc=en&dlc=en&docname=c03327635
    Wish you luck,
    Karthik
    --Say "Thanks" by clicking the Kudos (purple thumbs up icon in the lower right corner of a post)
    --Please mark the post that solves your problem as "Accepted Solution"

  • The templates are not showing up after I select them???

    the templates on pages are not showing up after I select them....unless I highlight the entire page and select a particular colour.  That leaves all the colours in the photo off.  Any help would be so very helpful.   

    CeraG - It will help to answer if you supply your system version, pages version and if you lately have done anything to the computer (installing, uninstalling etc)
    I think you have forgotten to do a Software update or it could also be a font problem but more info from you is needed!

  • All iPad buttons are not working even after resetting it (hard, soft and via iTunes).

    All iPad 2 buttons are not working even after I resetting it. I tried both of the hard and soft reset, and even resetting my iPad via iTunes. 
    The volume buttons work after I tried this method : "hold iPad in landscape mode. Push the home button while rotating it to Portrait mode, release it."

    I have the same issue, nothing I did fixed the problem, I would suggest if you can visit apple store and give us your feedback with them.
    for me I can't go to apple store because I don't have any store near me, I will have to wait for 2 months to travel!

  • I-phone 4 froze after an update, will not shut down and sends all calls to voicemail. Apple logo is the only screen that I get, is there anything I can do?

    I-PHONE 4 FROZE AFTER AN UPDATE, WILL NOT SHUT DOWN AND SENDS ALL CALLS TO VOICEMAIL, IS THERE ANYTHING I CAN DO?

    Unplug it and let unit go dead. Then hold your Home button down and plug the USB power cord back in. iTunes should see it and then restore.
    Basic troubleshooting steps  
    17" 2.2GHz i7 Quad-Core MacBook Pro  8G RAM  750G HD + OCZ Vertex 3 SSD Boot HD 
    Got problems with your Apple iDevice-like iPhone, iPad or iPod touch? Try Troubleshooting 101
     In Memory of Steve Jobs 

  • Databases are not coming up after server reboot(sun solaris).

    Hi
    OS - Sun OS 5.10 local zone. RDBMS version - 11.2.0.3
    Databases are not coming up after server reboot.
    We have verified the below points.
    Cat/etc/init.d/oracle
    $ORACLE_HOME/bin/oradism file permissions are 4550.
    lock_sga is parameter set to false.
    cat /var/opt/oracle/oratab entries are set to Y
    Still Databases are not coming up after server reboot.
    Please advise.

    Hi,
    Can you post further information from alert log. Doesn't coming up, means you needs to share the information some thing about your environmente settings about kernel parameter and init$ORACLE_SID parameters details.
    That would be easy for others to look into it further to analyze things.
    - Pavan Kumar N

  • 802.1x what happens after EAPOL logoff if Port does not go down

    Hi all,
    we are using 802.1x machine-authentication with EAP-TLS and dynamic VLAN-assignment.
    lets say a device is successful authenticated and VLAN DATA is assigned.
    After a time the Device is sending EAPOL logoff for any reason, and is silent from this moment on ( does not send any packet).
    So the auth Session is cleared and the VLAN Assigment is removed ( looks like Port is assigned to VLAN0)
    So the problem is if the MAC is unauthenticated and POrt has no VLAN assigment it is impossible to send WOL Magig packet or similar staff ( INtel AMT)
    What will happen from here on? Does the Switch to try to initiate Authentication by sending an EAP Request periodic for ever until it receives EAP Response or EAPOL Start, or do we have to wait that Client ist starting EAP process
    thxin Advance
    Hubert

    You need to configure the following:
    dot1x guest-vlan supplicant
    It's a global knob to address this type of use-case. What'll happen when you configure the above is not only will the session be torn down after EAPOL-Logoff processing; the switch will continue to send EAPOL-Id-Requests out on the same port, but based on the lack of response to just this new set of requests can put the port into the Guest-VLAN since the client isn't answering.
    NOTE: I assume you know what you're getting into here with VLANs, since you might be changing the subnet and the machine may need to release/renew for an address. The Guest-VLAN could be the same as the existing ones though, so up to you.

  • 3825 FXO Port remains in off-hook after call

    Hello,
    I have a 3825 router with 8 FXO ports running Cisco IOS Software, 3800 Software (C3825-SPSERVICESK9-M), Version 12.4(24)T3, RELEASE SOFTWARE (fc2). The problem we are facing is that after a call is placed through any of the FXO ports and the call is ended by the user, the port remains in off-hook till a reset of the port is done or someone restarts the router. Only then is the port accessible again.
    I am thinking of changing the cards, but i do not want to invest in replacing the cards and then find out that this doesnt solve the problem.
    The wierd thing is that this issue started on its own accord not too long ago.
    Comments and suggestions please!
    Regards,
    Femi

    Hello,
    I do not want to change the FXO card till I am sure that is the problem and I did state that I always have to reboot the router when the problem starts. Rebooting clears the problem but it is back immediately I attempt a call again and hang up that call.
    I have timeouts call-disconnect already configured, see below:
    voice-port 0/0/0
    supervisory disconnect dualtone mid-call
    compand-type a-law
    timeouts call-disconnect 5
    timeouts wait-release 5
    connection plar opx 21000
    description FXO CONNECTION TO PSTN
    caller-id enable
    voice-port 0/0/1
    supervisory disconnect dualtone mid-call
    compand-type a-law
    timeouts call-disconnect 5
    timeouts wait-release 5
    connection plar opx 2626878
    caller-id enable type 1
    voice-port 0/0/2
    supervisory disconnect dualtone mid-call
    compand-type a-law
    timeouts call-disconnect 5
    timeouts wait-release 5
    connection plar opx 21000
    description FXO CONNECTION TO PSTN
    caller-id enable
    voice-port 0/0/3
    supervisory disconnect dualtone mid-call
    compand-type a-law
    timeouts call-disconnect 5
    timeouts wait-release 5
    connection plar opx 21000
    description FXO CONNECTION TO PSTN
    caller-id enable
    voice-port 0/1/0
    supervisory disconnect dualtone mid-call
    compand-type a-law
    timeouts call-disconnect 5
    timeouts wait-release 5
    connection plar opx 21000
    description FXO CONNECTION TO PSTN
    caller-id enable
    voice-port 0/1/1
    supervisory disconnect dualtone mid-call
    compand-type a-law
    timeouts call-disconnect 5
    timeouts wait-release 5
    connection plar opx 21000
    description FXO CONNECTION TO PSTN
    caller-id enable
    voice-port 0/1/2
    supervisory disconnect dualtone mid-call
    compand-type a-law
    timeouts call-disconnect 5
    timeouts wait-release 5
    connection plar opx 21000
    description FXO CONNECTION TO PSTN
    caller-id enable
    voice-port 0/1/3
    supervisory disconnect dualtone mid-call
    compand-type a-law
    timeouts call-disconnect 5
    timeouts wait-release 5
    connection plar opx 21000
    description FXO CONNECTION TO PSTN
    caller-id enable
    Regards,
    Femi

  • Cisco 5.0 "Your messages are not available now" after exchange 2010 and DC migration to a new host

    Guys,
    First of all, thanks for looking at this post. Hopefully you guys can help me out. My unity users, when dialing into voicemail are getting the message "Your messages are not available now".
    Services in error state under the event viewer:
    Event Type:    Error
    Event Source:    CSAgent
    Event Category:    Kernel Rule 
    Event ID:    256
    Date:        7/29/2014
    Time:        11:42:41 AM
    User:        N/A
    Computer:    UNITY
    Description:
    A packet with a bad transport layer header was detected. Reason: Illegal TCP reserved flags set using interface Wired\HP NC324i PCIe Dual Port Gigabit Server Adapter. TCP: 00.000.00.000/443->00.00.0.00/1241, flags 0x10. The operation was denied.
    Event Type:    Error
    Event Source:    CiscoUnity_MALEx
    Event Category:    Error 
    Event ID:    30012
    Date:        7/29/2014
    Time:        11:44:27 AM
    User:        N/A
    Computer:    UNITY
    Description:
    An occurred which prevents successful Exchange access by CsBMsgConnector via MAPI.
    This is typically an indication of configuration issues with Unity, Exchange, or the MAPI subsystem.
    Verify that the Unity services accounts are granted the correct permissions and that there are no issues with installation.  The SysCheck utility may assist in diagnosing the problem.
    Event Type:    Error
    Event Source:    CiscoUnity_Doh
    Event Category:    Error 
    Event ID:    32013
    Date:        7/29/2014
    Time:        11:44:27 AM
    User:        N/A
    Computer:    UNITY
    Description:
    Doh logon failed due to messaging component logon error: 8004052eH
    I found and followed to the letter:
    http://www.cisco.com/c/en/us/support/docs/voice-unified-communications/unity/107323-unity-error.html
    I also went ahead and ran GUSI with some mixed results under environment information:
    SQL Version = Microsoft SQL Server  2000 - 8.00.2282: unknown SP
         SQL Edition = Desktop Engine
         Windows version =  5.2 Build 3790: Service Pack 2
         Outlook is not installed on the local server
         MAPI Provider : CDO Version - 6.5.8211.0
         MAPI Shared Memory: (HKLM:SOFTWARE\Microsoft\Windows Messaging Subsystem\Applications\<process>\SharedMemMaxSize)
                AvCsMgr : is set to recommended value
                AvMsgStoreMonitorSvr : RegKey not found.  Recommend add the key AvMsgStoreMonitorSvr and set DWORD SharedMemMaxSize with a value of 4194304 (decimal)
                AvNotifierMgr : RegKey not found.  Recommend add the key AvNotifierMgr and set DWORD SharedMemMaxSize with a value of 4194304 (decimal)
                AvUMRSyncSvr : is set to recommended value
                CsBMsgConnector : RegKey not found.  Recommend add the key CsBMsgConnector and set DWORD SharedMemMaxSize with a value of 4194304 (decimal)
                CsBridgeConnector : RegKey not found.  Recommend add the key CsBridgeConnector and set DWORD SharedMemMaxSize with a value of 4194304 (decimal)
                CsVpimConnector : RegKey not found.  Recommend add the key CsVpimConnector and set DWORD SharedMemMaxSize with a value of 4194304 (decimal)
             TCPChimney : Disabled
             RSS : Disabled
             *Pulled from UnityDB Configuration Table*
             ExcludeAllReceipts : 0
             ExcludeReturnReceipts : 0
             DisableSearchFolderUse : 0
             MinSearchFolderLifeHours : 1
             OptimizeSearchFolderUse : 0
    I tried following and deleting the Unity System Profile:
    https://supportforums.cisco.com/discussion/11249996/unity-501-exchange-2010-unable-logon-mapi-mailbox
    But I am still scratching my head. Any direction will be appreciated.

    Turns out that unity came back after all this. Maybe it just needed time. I think I answered my own question.  Anyways, this post could serve for future reference. 