SPDD for structure E1HR_AB
Hi Gurus,
We are upgrading from 4.6 to ECC 6.0. When I tried to 'Reset to Original' the object E1HR_AB (Struture), I get an error 'You cannot edit object R3TR TABL E1HR_AB with
standard editor'.
Please let me know how to solve this.
Thanks in advance.
Mohan
Hi Mohan,
I can understand the issue here. The E1HR_AB is a segment that is used for PAyroll outsourcing using IDocs. This is generated through a transaction PU12. The possible reason can be that somebody might have done an enhancement to the standard segment by using the PU12 transaction for this segment under OTMU format. You'll need to just correct this back and do the upgrade and it should allow you.
Thanks,
Sam
Similar Messages
-
Check-In not locked for structure element in SOLMAN_DIRECTORY
Hi,
In the solution manager, as a pre-requisite of the one of the upgrade project,
all the BPS nodes should be checked in the solution directory.
But we are not able to check in .
Getting below error message.
" Check-In not locked for structure element PD-PPD of type with object_no 0000847512 "
Message no. MAINT_PR046
Can anyone please suggest what could be the issue.Please ensure whether both projects have the same budget profile. Other than that you need to carefully investigate how the cost was posted onto both projects in the first place. Please note in case of procurements, budget is only checked at the commitments level (search the forum as this has been discussed before).
In case this does not resolve your issue, revert back with the budget profile settings.
Regards,
Ammar -
Price variance distributed for structured material
Hello,
Where can I customize this option: price variance distributed for structured material?
In question is field DRSEG-XVPAS, I would like to understand how it is influenced.
Iu2019ve tried looking for it but with no results.
Thank you,
Helena
Edited by: helena teixeira on Jul 4, 2008 1:50 PMHi,
Take an easy way, you can go to the PO with t-code ME23N, at tab page PO history of the item detail, you can find the price variance for the item.
Or you can use t-code MB5S to display the multi-POs' price variance report!
Cheers
Tao -
Question for structuring an application
Are there any Best Practice Guides for structuring applications in WDP4J?( like separation of model in own DC etc...)
Best regards,
ThomasHi,
Check these docs:
https://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/604ddc2f-ec9c-2b10-1682-be37e1c62dee
https://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/e0d6c30a-c99e-2b10-f09b-c9a00b7e78c6
https://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/e0e682bd-b59e-2b10-cd82-fa175f502fe6
https://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/50568365-ba9e-2b10-1188-a612a20edf31
Regards,
Anagha -
Pre requisites for Structural Authorizations
Guys,
Can some one tell me what are the Pre requisites that I need to follow before implementing Structural Authorizations? Please share your thoughts.
Thanks,
KumarThanks Sikindar,
This document is for BW 3.x and we are implementing Struct Auth in BI 7.0, infact I have the same document as well. I am trying to see whether anything has changed in configuration point of view from BW 3.x to BI 7 for Structural Authorizations.
Thanks,
Kumar -
Regeneration of INDX for Structural Authorization
Hello all,
We are having problems with the index of structural authorization.... employees can´t see objects created until we run the program RHBAUS00.
I'm reading at the documentation of program RHBAUS00, and it says that "The index for the structural authorization profile of the user is generally regenerated during the night in a batch job"..... but it is not working !
Does any body know how SAP execute an automated regeneration of index for structural authorization?
I want to know which job do that or how the system do that? or if I need to define a job by my self?
Thanks in adcanve.
Enrique VeraHi Enrique,
I think you have misanderstood the documentation.What it says is that usually customers run this program RHBAUS00 as batch every night. But apart from the report there is no other program/functionality that will reset the INDEX
You have to set up this report to run as BDC everynight if you require it.
Hope this help
Sarah -
Extraction log for structure MC12VC0ITM?
Hi
Im not sure where i can find the extraction log for structure MC12VC0ITM. The extraction log will hold the delta changes done. It will help us identify if there are any issues in capturing the delta records while creating any transaction ex: delivery documents created using the Tcode VL03 and it is getting captured in delta properly or not. The data source is 2LIS_12_VCITM.
I have tried with SM13, LBWQ, SMQ1 and RSA7 but no luck.
Regards
Sadeesh
Edited by: Sadeesh V on Jul 8, 2009 11:01 AMWhat exactly you want to check ?
Once the data is posted it should be available in LBWQ as LUW for Queued delta and on running job control it will be available in RSA7 where you can display the records. -
Error in subroutine read_namtb for structure of infotype
We are trying to transfer HR Master data between ERP 5.0 and ECC 6.0 systems .
The data transfer is successful in the development and Quality environments but fails in case of production environment.
Details are given below
Message type : HRMD_A
Idoc type : HRMD_A06 ( Release 620 )
When we try running PFAL using any evaluation path the idoc at the receiver ends up with an status 51 (error) .
The error log gives the following error .
u201CError in subroutine read_namtb for structure of infotypeu201D.
I tried posting the received Idoc again at the receiving end using the transaction WE19 with the function module u201CIDOC_INPUT_HRMDu201D .
The observations are given below.
1. While processing some of the records the infotype table name field becomes empty .
2. The subroutine read_namtb uses a FM u201CNAMETAB_GETu201D , which takes the input as the infotype table name and provides the output as all the fields of the table along with the attributes of the field.
3. As sometimes the table name is passed empty the function module returns an error which is mentioned above.
Note : If we run PFAL without providing any evaluation path the idoc at receiver ends up with status 52 ( Application not posted completely).Hi Hadiman,
I will activate those BADI's and check.
But we solved the problem in a different way.
Below is the analysis of the error.
1. The data was getting passed in an additional segment E1PAD007 in the production environment from the sender system.
2. During the inbound process the FM u201CRH_INFTY_OF_IDOCSEG_TYP_GETu201D is used to identify the respective infotype and the subtype
for the segment name in the receiver system.
3. The function module searches for the tables T777D and table T77ar to fetch the infotype and the subtype.
4. The table T77ar does not contain the relevant entry .
5. The segment is related to a relationship u201C007u201D between jobs and positions.
6. As we do not need jobs in the target system, we removed the object type u2018Cu2019 from the model distribution. This resolved the error.
Note : The other way to resolve was to make an appropriate entry in the table T77AR .
Thanks a lot Hadiman for the reply, will check with those BADI's too which you mentioned
Regards,
Santosh. -
Offset declaration too big for structure (unicode checks)
Has anyone worked with this user exit to Derive values for co/pa?
Enhancement COPA0001
Comp ZXKKEU11
I set up WA_CE1AWG1 as data: WA_CE1AWG1 like CE1AWG1.
and tried to copy I_COPA_ITEM to this variable
WA_CE1AWG1 = I_COPA_ITEM.
I get a runtime error Offset declaration too big for structure.
will I have to change program SAPLXKKE to remove unicode checks. Is there any other way to read in the fields from input structure I_COPA_ITEM?hi
1.r u sure I_COPA_ITEM is structure or table.
2. if it is a struccture make sure the WA_CE1AWG1 and I_COPA_ITEM are with same structures and types..
i think I_COPA_ITEM is table type --> to find it open in debugging mode then try to resolve.
Please Close this thread.. when u r problem is solved
Reward if Helpful
Regards
Naresh Reddy K -
Inconsistency in the Dictionary for structure COMT_BSP_BP_SEAREQ_DIVERSE
Please could someone help me out on this one. I am new to ABAP and CRM Technical and have just started my career on this new track. I am getting "Inconsistency in the Dictionary for the structure COMT_BSP_BP_SEAREQ_DIVERSE" on the WebUI as error when I am logging into it -this error has got generated after I was trying to create a field using AET on WebUI. I have taken the help of another ABAPer who is presently more adept that me and he used st22 to identify that a class 'CL_BUPA_IL_SEARCH_SERVICE' is not getting activated which is resulting in this error. There is 'Inconsistency in the Dictionary for the structure "COMT_BSP_BP_SEAREQ_DIVERSE".' The BASIS guys have told me that I need to find some note to get this fixed - I have never done this. Please could someone give me a step- by-step solution to get this issue resolved. Please if there is any notes that would supplement this, kindly mail me at nishant.prasad(at)zensar.in. Thank you.
Inconsistency in the Dictionary for the structure "COMT_BSP_BP_SEAREQ_DIVERSE".Error in the SAP kernel. The current ABAP "SAPLCOM_PARTNER_TOOLS" program had to be terminated because the ABAP processor detected an internal system error. Please could someone provide resolution.
-
Bit Ordering for Structures in a Union
Hello. I seem to be having a problem with interpreting data placed into a char array that is overlayed with a structure. It seems to be related to bit ordering. The overall scope of my application is to take a data packet, send it over a serial communication port, then another application decodes the data packet, and places the data into a table. I built two seperate LabWindows applications that perform the tasks on both sides of the serial port, and they work properly. Each application makes use of the same header file containing structures defining the data packets. When I remove the LabWindows application on one side and replace it with my actual hardware, I start running into problems decoding the data sent over the serial port with the remaining LabWindows application.
The structure is as follows:
typedef struct
unsigned int lcu_status_id:4;
unsigned int fan_id: 1;
unsigned int dimv_id: 1;
unsigned int thunderstorm_id: 1;
unsigned int nvis_mode_id: 1;
unsigned int temp_id: 1;
unsigned int power_id: 1;
unsigned int fan_status_id: 1;
unsigned int lcu_fault: 1;
unsigned int undefined_bits: 4;
} LCU_STATUS_DEF;
typedef union
LCU_STATUS_DEF lcu_status_data;
unsigned char lcu_status_str[2];
When receiving data from the serial port (COM1), I use the following commands:
read_status = ComRd(1, buf, 1)
packets.lcu_status.lcu_status_str[0] = buf[0]; //packets is another structure not mentioned in above code containing LCU_STATUS and others
... Later in the code I fill data tables by assigning each table the value that is stored in the packets.lcu_status.lcu_status_data.lcu_status_id (or whichever of the variables in the structure I need)
I'm finding that the actual hardware sends the data across the serial port correctly, so that packets.lcu_status.lcu_status_str[0] (and subsequent words) is filled correctly. For example, if I send across a word containing 27 (decimal) then packets.lcu_status.lcu_status_str[0] is filled with 27 when I read it in debug mode. The next word I send is 16 and packets.lcu_status.lcu_status_str[1] is filled with 16. However,
I would expect the structure to then be filled like so:
lcu_status_id = 3
fan_id = 1
dimv_id = 0
thunderstorm_id = 1
nvis_mode_id = 1
temp_id = 0
power_id = 0
fan_status_id = 0
lcu_fault = 1
undefined_bits = 0
But instead, I get:
lcu_status_id = 0
fan_id = 1
dimv_id = 0
thunderstorm_id = 0
nvis_mode_id = 0
temp_id = 1
power_id = 1
fan_status_id = 0
lcu_fault = 1
undefined_bits = 3
I do not understand why this bit order occurs. Would anyone be able to explain?
Thank you,
JasonJason,
Seems to me that your hardware communicates in "big endian" (as many embedded systems do). This means that you will need to rearrange the bytes in the numeric data you receive before using the values. The same will apply to any numeric data you send.
Have a look at Roberto's reply in this thread. Also, here is an informative article discussing endianness.
Cheers,
Colin. -
Table name for structure KKBCS_OUT
Hi all,
We have a report for which we are getting data from a structure KKBCS_OUT.
Can anyone please let me know the name of table related to this structure?
Thanks & Regards,
KavithaHi,
Check the below tables
cosp, coss, cosl, aufk, qmat .
Try running sql trace to find out the same.
Go to ST05 , click on active trace .... open another session , run ur transaction .... come to ST05, clikc on deactive the trace..... and click on display trace.....now u can able to see all tables and field names, which are used in ur transaction.
Regards. -
Context sensitive solution for Structural authorization
Dear all,
I would like to know whether new relationship, evaluation path and authorization profile has to be created for each role with context sensitive structural authorization ?
In T77UA table, each user has assigned a profile which tells the system how to find the structure by evaluation path (in T77PR table). Then in tranx OOAW, the evaluation path indicate how to build the structure by series of relationship, and this way we have to create new relationship for each role with context.
Am i correct ?
If an organization has many roles, then many relationship, evaluation path, profile.. has to be created !
Thanks for your help !
patrick cheungHi Chandra,
Thanks for your prompt reply !
This is for <u>Context Sensitive</u> solution, <b>not</b> the normal structural authorization:
Yes, if you add the authorization object P_ORGINCON in PFCG, you will notice that the field "<b>Authorization Profile</b>" has to be entered which tells the system <i>WHICH ORG STRUCTURE</i> does this authorization are refering to...
In table T77PR, instead of hardcoding the organization unit in the object ID field, we use Evaluation path to tell the system how to find the org structure for employees. Function RH_GET_MANAGER_ASSIGNMENT will return the org unit ID for the evaluation path.
In transaction OOAW, the said evaluation path specified the relationships which the system should use to draw the org structure of the employee's supervision... and there should be relationship like "<b>Is managed by</b>", may be as follows:
O B 002 Is line supervisor of * O
O A 011 Cost center asignmnt * K
O B 003 Incorporates * S
O B 012 <b>Is managed by...</b> * S
Up to now.... if you want to assign authorization to someone as follows, you could not simply maintain the same relationship "<b>Is managed by</b>" to Org Structure A and B because this will confuse the system as to which org structure you want the employee to maintain infotype 7 or 14/15. You should then create different relationships and maintain them to Org Structure A and B. And tell the system how to find the structure from the Evaluation path, which is stick to the Auth. profile. The Auth. profile is then maintain in the Context sensitive master data object P_ORGINCON !
(1)
Org Structure A
Maintain only infotype 7
(2)
Org Structure B
Maintain only infotype 14, 15
So... that's why i said if an employee has many role to perform duties in many different Org Structures (e.g. A, B, C...etc), you would create many relationship...
Hope this message will give idea to someone who intend to implement Context Sensitive Solution. -
ABAP DDIC table name for structure definition
Hello,
Can anybody tell me what is the name of DDIC table used for storing ABAP structure definition and also its related tables.
Thanks&Regards,
PrajeshHi again,
1. There is one more field
in DD03L table.
2. DEPTH
3. Normally this field will be blank.
4. In your case,
u have 2 common fields.
eg. F2
5. Then
it will be like this in table
F2 - space
F2 - 1
6. The second entry is for DEPTH.
regards,
amit m. -
Hi,
These are 4 fields are from different structure.We are unable to find tables for these structures.
All field and structures are from VA03 transaction in ECC.
*Name :Production Order Status Structure : CAUFVD FieldSTTXT*
*Name:Sales Order header Status Structure VBSTT Field GBSTA_BEZ*
*Name:Material Style (in SO).T(from Sales order) Field ATWRT*
*Name; Sales Order line item Status*
Please anyone can help us
Thanks,
SridharHi
It seems that you want test of the describ fields, for which you need to find relevant test table.
For Production order status use--->
Goto CAUFV
get the field - CAUFV-OBJNR
Pass this in JEST in field = OBJNR, object number and INACT = space
you will get severail entries for field STAT.
pass this field entries STAT to tabel TJ02T and field - ISTAT, language = EN
you will get status in the field TJ02T-TXT04 and text in field - TJ02T-TXT30.
or simply use FM- STATUS_TEXT_EDIT
Thank-You.
Regards,
Vinod
Maybe you are looking for
-
Hi guys! PLEASE PLEASE PLEASE someone help me!!! I have been trying for ages to change this!! It is SO frustrating!! I recently bought a new MacBook Pro 13" after my old one (2009) got stolen. Went from Snow Leopard to 10.8.2, restored all my app
-
I bought the bundle with adobe photoshop elements 12 and adobe premiere elements 12 for my new MacBook Air. I was told that not having a CD drive wouldn't be a problem for the download, but I can't figure out how to download them without being able t
-
Disappear programs of my kmenuedit
After that I installed new glibc, disappear of my kdemenu a lot of programs like openoffice, gimp, inkscape, firefox, pidgin etc. I use KDE. It possible recover all of programs lost in menu by replace the file with new configs by file with older conf
-
Wiki Access Problem in China!!
Hey, Guys! I am a Chinese student in college in Shanghai. It seems that our government have deployed a way to restrict its people's access to informations outside, specifically political truth. Wiki is such a great free encyclopedia. Unfortunately, W
-
How to Share Transport directory in Landscape
Hi, I want to know how to make transport direcory shared in windows and mounted in unix.......Please tell me the Step wise procedure. Thanks in advance. paramvir