SPI communicat​ion protocol with LabVIEW and 6062E PCMCIA Card. Is it possible?

Hey people. I'd like to know if it's possible to get SPI communication with 6062E card, and if there is any example of that use.
Thank you!

Good afternoon,
With this hardware NI DAQCard-6062E (for PCMCIA) has inputs / outputs digital and analog, but has hardware that makes USB-8451 communication with SPI. Below is the link to the Hardware. Any questions please contact us.
NI USB-8451
http://sine.ni.com/nips/cds/view/p/lang/en/nid/202​368
graciously
Mauro Vera
Applications Engineer
National Instruments

Similar Messages

  • What communicat​ions protocols does LabView support?

    A customer of mine is using LabView.  He has asked me if I can communicate to it using a PLC.  Either GE Fanuc or Allen-Bradley.  I need to know what methods of communication that LabView has available to talk to these PLC's.

    The short answer is: whatever protocol you want to talk...
    I have developed applications talking to AB stuff, modbus (which will cover most PLCs) and even TI's old proprietry PLC protocol. There are lots of tools for making the connection in lots of ways.
    What are they specifically needing--or do they know yet?
    Mike...
    Certified Professional Instructor
    Certified LabVIEW Architect
    LabVIEW Champion
    "... after all, He's not a tame lion..."
    Be thinking ahead and mark your dance card for NI Week 2015 now: TS 6139 - Object Oriented First Steps

  • Analogic acquisition with Labview and National Instruments card

    I need to acquire 2 analogic signals simultaneously. I use version 4
    (maybe 5) of Labview, with a National Instruments data acquisition
    card (BNC-208x). I want to save the 2 signals in a text file. Does
    anyone could send to me a diagram (vi) for doing that.
    Thank you very much.
    (my email: [email protected])

    True simultaneous sampling is possible with only a few types of DAQ cards. I believe BNC-208x is like the current BNC-2xxx series and is nothing more than a adaptor to the actual DAQ card inside the PC. If you can live with the small delay between channels that the majority of DAQ boards has, then there are a number of shipping examples that can help you. Look for the Cont Acq&Graph examples and Data Logger to Spreadsheet File.

  • NI-FBUS Communicat​ions Manager won't start when PCMCIA card is configured as Basic Device and Visitor address

    I can't get the NI-FBUS Communications Manager to start up unless the PCMCIA Series 2 Card is configures as Link Master. I want to Connect to a FFB Segement which already has a LAS 

    Hello,
    The same case.
    It means that fisically I have to connect the the PCMCIA to the actual segment (with its LAS) and then start up the NI-FBUS Comm. Manager?
    Like a Basic Device and Visitor Address will let me change parameters at the devices?
    Thanks in advance,
    Braulio

  • Is it possible to use an IrDA protocol with LabVIEW 8.2.1 in DSP BlackFin?

    Dears,
         I'm building a project to communicate a DSP BlackFin 533 with a Palm E2 Tungsten between IrDA Protocol. The packaged LabVIEW installed in Palm allows to use IrDA protocol, but I don't know if the packaged for BlackFin DSP allows or not.
       Is it possible to use an IrDA protocol with LabVIEW 8.2.1 in DSP BlackFin?
    Regards,
    Renato - RPS

    OpPss ...
    Sorry !!!
    Attachments:
    IrSerial.zip ‏11 KB
    IrSerial1.zip ‏11 KB

  • How to switch central frequency fastly with labview and USRP?

    Hello everybody,
             Recently I was making a frequency hopping receiver with labview and USRP N210 and SBX. The transmitter works on the 2.4G band, and it changes from one central frequency to another every 65536us. As I think, if I start receiving at the correct time, and  change the central frequency of the USRP every 65536us, I should be able to receive the data.
        But I find that, when usrp switch form one central frequency to a different one, it spends nearly 48ms and when it switch from one frequency to the same one, it only spends 3ms(I test the performance by modifying the niUSRP EX Rx Continuous Async Reconfig on the Fly.vi example). So if I want to follow the hopping sequency, I may can only receive 17ms data because I have to save time for switching central frequency. 
         My problem is that: why usrp changes central frequency so slow,  how can I make the process faster? If I want to follow the hopping sequency, can anybody give me some good advice? Thanks

    There is an attribute "LO Frequency" that you can use to lock down the frequency of the local oscillator.  Then, when you set the "Carrier Frequency" attribute, the difference between the carrier frequency value and the LO frequency value will be realized by frequency shift in the DSP in the FPGA.  Changing this "digital" frequency shift value is much faster, since you don't have to re-tune the local oscillator.
    Let's say you're sweeping from 2.44 GHz to 2.46 GHz.  Set the "LO Frequency" to 2.45 GHz then Commit.  Then, in your loop, program the "Carrier Frequency" attribute from 2.44 GHz to 2.46 GHz.  In the loop, it will only program the digital frequency shift, which will happen much faster.
    Another tip is to use the property node to program only the attributes you want to change, rather than the niUSRP Configure Signal.vi (which sets many at once).
    For more details, see the "Configuration:Advanced:LO Frequency Property" in the NI-USRP Help, and look at this example:
    <LabVIEW dir>\examples\instr\niUSRP\niUSRP EX Fine-Tune LO Frequency.vi

  • How can i work simultaniously with labVIEW and Excel ?

    Hello . I study engineering and need some help with labVIEW, and the connection to microsoft excel.

    Hi
    NI offers an "Report generation toolkit". You get some VI's with this toolkit and so you can directly create your reports from LV.
    Another possibility is the communication through ActiveX. There is a nice link with application notes and LV examples for that:
    http://zone.ni.com/devzone/devzone.nsf/webcategories/C3E56C69D399361E86256AB7006A9149?opendocument&node=DZ53003_US
    Regards,
    Luca

  • Anyone got experience with LabView and JTAG ?

    Anyone got experience with LabView and JTAG ?
    Especially in system programming of Altera and FLASH

    Yes, I've actually driven JTAG using DIO, but this was a project in itself.
    I guess you're just wanting to get the job done! I'm currently evaluating
    gear to do the same job myself, in addition to interconnect testing. I've
    been looking at JTAG Technologies equipment. They do PCI/PXI cards and the
    SW, with a LabVIEW interface.
    They're at:
    www.jtag.com
    You'll need to be sitting down when you get their quote though - their development
    system costs about the same as a decent car!
    Cheers
    -Sean.
    [email protected] wrote:
    >Anyone got experience with LabView and JTAG ? >Especially in system programming
    of Altera and FLASH

  • Controling heating/cooling element with labview and usb 6008 DAQ card

    Greetings All
    I'm looking for a heating/cooling type of element that I can control with labview and my usb-6008 card. Heating/Cooling will just be for clean water and the temperture range will be from 0 C to 100 degree C.
    Thanks
    The heating and cooling elements can be seperate products. Any recommendations

    A simple kettle element will of course be sufficient for upto 100°C
    To get the temperature down you need a cooling system, what springs readily to mind of course is a refrigerator.
    Just a note of warning, water and electricity are dangerous bed fellows.
    On that note perhaps one of those vortex air units would be safer - they blow hot in one direction and cold in the other, nominally to 100°C
    see: -
    http://www.airtxinternational.com/how_vortex_tubes_work.php

  • Is it worthy to buy a Zen with 2Gb and a SD card of 4 or is it better to buy a Zen with 4

    Hi.
    I'm thinking on buying a Zen, but i'm a bit confused on the issue of if is it better to buy a Zen with 4Gb or a Zen with 2Gb and a SD card with 4Gb, because the diference on the pricefrom the 2Gb to the 4Gb fits a SD card with 4Gb, and will result in a Zen with 6Gb...
    Does the zen works fine with the reading times of the SD cards? Or does the performance drops when reading from the card?
    I would apreciate your experience/knowing opinions.
    Thanks
    BM

    Ask that question here.http://epizenter.net/e07_plugins/forum/forum.php

  • Dm4-1060us laptop SD Card Reader 5-in-1 question. Does it work with SDHC and SDXC memory cards?

    dm4-1060us laptop SD Card Reader 5-in-1 question. Does it work with SDHC and SDXC memory cards?

    This cart reader is a kind of multi card reader and you can use different cards with it. In my opinion every multi device should be used very, but very gently. I do not know what happened exactly in your case but maybe you have damaged something inside.
    Try to restart your notebook and use other SD card to check if everything works well. Please do it very gently and if you see something is wrong stop with inserting the card.
    I use 1 GB SD card on my A200 without any problems.
    In my opinion you should check notebook by technician.
    Bye and good luck!

  • Which NB100 comes with Bluetooth and the sim card slot

    i am wondering which model come with bluetooth and the sim card slot,

    I was a little disappointed the Bluetooth is missing on the NB 1000 12A, agreed the Bluetooth logo is on the left side of the box although the actual product spec sticker is on the right side and it only mentions wireless b/g.
    Some of the listings for this model online do say it has Bluetooth although its evident its not included.
    I have ordered one of these to cover the lack of onboard Bluetooth support:
    http://www.memorybits.co.uk/product_info.php?products_id=8156
    Regards,
    Stephen

  • "How to use an Appplicom card with Labview and a Seimens PLC"

    Hi, I am using an applicom card type PCI1500-PFB to communicate with a Seimens S7-300 CPU315-2DP plc. I am using this simply to display in a labview front panel the outputs of the plc and may in the future use switches on the front panel to control the inputs of the plc. How do I do the communication? I have setup the applicam card and have comms with the plc I think. I am trying to use data socket to communicate to the plc via the applicom card. Any suggestions?
    Thanks
    Tom

    There�s a fair bit of documentation on NI�s site regarding the Applicom card.
    The following doc does a pretty good job summarizing Applicom's PCCONF and PCINIT, and the use of ReadWait and WriteWait to ensure you�ve got communication with the between the PLC and the Applicom card:
    http://zone.ni.com/devzone/conceptd.nsf/2d17d611efb58b22862567a9006ffe76/5913e03f551de3f786256a32005b4586?OpenDocument
    Since it doesn�t sound like you�re using the LV DSC module, you can stop reading once it gets into connecting to Lookout Objects.
    Once you�re sure you�ve got comm, you can do some quick tests in LabVIEW using front panel datasocket connections as shown on page 11-12 of the following:
    http://www.ni.com/pdf/manuals/323241a.pdf
    From there, it all depends on
    the complexity of your system. If simple, you could just stay with front panel connections, or you could move to programming with the Datasocket Read and Write functions.
    ... and if you get to the point that Datasocket is too slow and cumbersome, you might want to look at the LV DSC module:
    http://ni.com/labview/labviewdsc/what_is.htm?node=10418
    =====================================================
    Fading out. " ... J. Arthur Rank on gong."

  • Problem with Labview and an ARM Cortex

    Good morning,
    I am currently trying to use Labview with a board from ST Microelectronics (MCBSTM32) with an ARM Cortex Processor.
    I use the SDK and have followed the tutorials.
    But, when I try to launch the program (the simple loop as write in the tutorial n°2 : http://zone.ni.com/devzone/cda/tut/p/id/7029 ), Keil gives me an error via Labview:
    "Argument 'DARMSTM' not permitted for option 'device'."
    It seems that Keil does not allow an ARM Cortex from ST as the device.
    Moreover, after having this problem, I am unable to use a Keil project ,even a project which worked before, without Labview. I need to restart the computer.
    I also try to launch the Keil project generated by Labview, without using Labview, and it works. But as soon as I use Labview, I have the error.
    Did anyone already have this error or know how to solve it
    Thank you for your answer and sorry for my bad english.
    Regards,
    Raphaël VAISSIERE

    Hi Raphi,
    So let me make sure I understand,
    The project created in LabVIEW errors out with the message "Argument 'DARMSTM' not permitted for option 'device" 
    If you open the same project in Keil uVision, it runs fine
    Here are my questions:
    1. So how does the code run when run through Keil? does it deploy and run fine?
    2. Did you follow the porting procedure completely?
    Your target STM32F103RB  is techincally supported by Keil but you need to port the RTX kernel to it. This paragraph explains it:
    To determine if your target already supports the RTX Real-Time Kernel, browse to the \Keil\ARM\Startup directory, then browse to the folder that corresponds to the manufacturer of your ARM microcontroller. If there is an RTX_Conf*.c file for your target, then the RTX Real-Time Kernel has already been ported for your ARM device. If no such file exists, skip to chapter 4 for more information on the RTX Real-Time Kernel and a guide for porting RTX to your ARM microcontroller. 
    You also need to port the Real-Time agent to it.
    I just want to make sure that you have followed the guidelines. If you have and are still having problems, we will continue to explore this.
    Thanks,
    National Instruments
    LabVIEW Embedded Product Support Engineer

  • Problems with Labview and Windows XP with error -214721786​5

    Hello. Im a new beginner in Labview and am having a problem with a error message
    I dont understand. Im running Labview on a pc-logger with windows XP.
    The program is written by a guy on my university, and logs voltage from
    a solar cell panel. He doesnt have the time to check in to it, so Im supposed to
    find out what's wrong.
    The error message is as follows :
    Error -2147217865 occured at Cmd Execute.vi->DB Tools Insert
    Data.vi->Solcelle.vi
    Possible reasons :
    Exception occured in Microsoft OLE DB Provider for ODBC Drivers,
    [MySQL][ODBC 3.51 Driver][mysqld-3.23.38-log]Can't open file :
    'solcelledata.MYD'. (errno: 145). in Rec Create - Command.vi-
    >Cmd Execute.vi->DB Tools Insert Data.vi->Solcelle.vi
    I really hope someone can tell me what's wrong and specifically what to do
    with it, or possibly guide me to someone who could suggest a solution to this
    problem.
    Reguards
    chrisdee

    Hi Chrisdee,
          (.. not to discount what TimoS has suggested, however...) 
    Embedded in the error information you provided:
    ... Can't open file : 'solcelledata.MYD'.
    Sounds like the program needs this file?  Has the program been moved to a new location?
    just a wild guess!
    Cheers
    Message Edited by Dynamik on 10-06-2005 04:53 AM
    When they give imbeciles handicap-parking, I won't have so far to walk!

Maybe you are looking for

  • Raw material Moving Avg. Price (MAP) should include overhead cost.

    We receive a raw material that has unit price of USD 10, the material is used in BOM. We incur some additional cost on that material and want to include that additional cost as a part of raw material cost. Say additional cost is USD 1 per unit. We wa

  • Keyboard for video editing in FCE

    Hi all I am looking for at video editing keyboard to go with FCE. Preferably with a shuttle weel, coloured keys and light in the keys. Was looking at the Bella Prof. Series 3. Has any of you experience with this keyboard or any other keyboard that yo

  • Slide scan attachment for 5200 C

    I have an old back-up computer running Widows XP in conjunction with an HP 5200C scanner.  I have the slide scan attachment for the scanner but can't get it to work.   I no longer have any of the operating instructions.   What do I need to do? This q

  • Making Recording in Studio sound like it was recorded live in a hall

    Hi all, I have a problem. My recordings sound too good!! What I mean is that there is not the feeling of it being in a hall, because what I call the "sound of the dead air" is missing. There is not the feeling of space in the silent bits of the recor

  • Im confused to what network im supposed to connect to

    This must sound stupid. bu ti have followed the steps and set my apple tv up as it says but when it asks me to pick a network to connect to i dont know if im supposed to connect to my internet connection or my imacs wireless card. So basically connec