SQL Connection Failed for SCCM 2012 R2 (Unable to load user-specified certificate)

We've recently completed an upgrade from SCCM 2012 SP1 to 2012 R2 and have been running in the new environment for about a week. As of this morning, The consoles failed to connect to the CAS' and one of the Primary Site's database. The issue was resolved
easily enough by addressing a certificate issue in SQL, but I'm left wondering if there's a correlation between the SP1-to-R2 upgrade that would cause the cert to fail. Anyone have experience with this?
2014-01-21 22:10:11.81 Server      The server could not load the certificate it needs to initiate an SSL connection. It returned the following error: 0x8009030d. Check certificates to make sure they are valid.
2014-01-21 22:10:11.81 Server      Error: 26014, Severity: 16, State: 1.
2014-01-21 22:10:11.81 Server      Unable to load user-specified certificate [Cert Hash(sha1) "haaaaassssshhhh"]. The server will not accept a connection. You should verify that the certificate is correctly installed. See
"Configuring Certificate for Use by SSL" in Books Online.
2014-01-21 22:10:11.81 Server      Error: 17182, Severity: 16, State: 1.
2014-01-21 22:10:11.81 Server      TDSSNIClient initialization failed with error 0x80092004, status code 0x80. Reason: Unable to initialize SSL support. Cannot find object or property.
2014-01-21 22:10:11.81 Server      Error: 17182, Severity: 16, State: 1.
2014-01-21 22:10:11.81 Server      TDSSNIClient initialization failed with error 0x80092004, status code 0x1. Reason: Initialization failed with an infrastructure error. Check for previous errors. Cannot find object or property.
2014-01-21 22:10:11.81 Server      Error: 17826, Severity: 18, State: 3.
2014-01-21 22:10:11.81 Server      Could not start the network library because of an internal error in the network library. To determine the cause, review the errors immediately preceding this one in the error log.
2014-01-21 22:10:11.81 Server      Error: 17120, Severity: 16, State: 1.
2014-01-21 22:10:11.81 Server      SQL Server could not spawn FRunCM thread. Check the SQL Server error log and the Windows event logs for information about possible related problems.

We got the same certificate related error events after a fresh install of SCCM 2012 R2 on a new server. It happened during the first reboot after SCCM was installed. In the Certificates mmc, I right-clicked on the certificate used by SQL and chose Manage
Private Keys. Giving the service account that runs the MSSQLSERVER service read rights to the private key allowed SQL to start. However, after a day or so we rebooted the server again, and SQL wouldn't start. Something had removed the service account's read
permission. Since the SCCM configuration wasn't that far along, we uninstalled SCCM. After giving the service account read rights again, and rebooting several times over a few days, and SQL started every time. We then installed SCCM 2012 R2 again, and checked
the certificate's permissions before rebooting. The service account still had read permissions when the install completed, but as soon as the server was rebooted, it lost the permissions again.
The Certificates mmc was then used to request a second computer certificate and then SQL was configured to use that new certificate via SQL Server Configuration Manager. After several days and a number of reboots the SQL services have started normally every
time so the second certificate seems to have fixed the issue. I have kept the original certificate for fear that removing it will cause whatever part of SCCM 2012 R2 that modifies the original certificate to start removing permissions from the new certificate
as well.

Similar Messages

  • Required Ports to connect remote SQL named Instance for SCCM 2012 R2

    Hi,
      I have allowed the TCP 1433,1434,135 and 80 but still unable to connect the remote SQL named instance DB for the SCCM 2012 R2... and getting below error..can you please suggest if any other port required for the same, i have turned off the windows
    firewall and RPC service is running ob Remote SQL and SCCM 2012 R2 server..
    CCMsetuplog
    Shailendra Dev

    During the installation you need more ports. You would also need the (dynamic) RPC ports. See for a complete list (section Site Server --> SQL Server):
    https://technet.microsoft.com/en-us/library/hh427328.aspx
    My Blog: http://www.petervanderwoude.nl/
    Follow me on twitter: pvanderwoude

  • Configuring Reporting services for SCCM 2012

    Hi,
    I just finish create SQL reporting services ( configure Database, report manager URL) in SQL 2008 R2 for SCCM 2012. When I open the Report option in SCCM console (Monitoring --> Report), no report listed there and then I try to add in Reporting service
    point for it, but get an error message
    "There is a problem connecting to the specific reporting server. Please check the connection and make sure SQL reporting service is running on the specified server"
    I manually browse to http://sqlserver/reportserver or
    http://sqlserver/reports , that is no any folder exist there (I assume when I configure reporting service it will automatic create a folder for it with all report inside?). Anyone can guide me on how to solve this issue?
    Regards,

    Hi,
    hi ,
    I am new to SCCM 2012 group and i have knowledge on sccm2007. i want to discuss some issue what i have with SCCM2012 installtion. The issue is my machine got rebooted while installing sccm 2012 SP1.i have already installed all the prerequisites for SCCM2012.i
    am installing sccm2012 on Hyper-V machine.
    Please see my system configuration below:
    DomainController(2008R2 server) : 512MB RAM, AD things and DNS ,DHCP has installed on it.
    System center server(2008R2) : 1028MB RAM , Sql 2008 server installed on it.
    i tried to install it many times but still i got the same issue.
    Could anybody please help me with this ?
    This is a new question. So please ask this question on a new thread in this forum.
    Thank you.
    Best Regards,
    Joyce Li
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • SCCM Console issue, SQL connectivity login failed for SCCM machine account

    Hi ,
    As part of resolving the corrupt SCCM 2012 R2 environment, we have uninstalled the site from the Standalone primary site and restored it from the last backup. The database is on remote server on SQL 2012 SP1. Only Site recovery is run.
    Post the restoration on unable to launch the SCCM console, Error Could not connect to the site.
    When I checked the logs in the log file SmsProv.log in the program filles\Microsoft Configuration manager\logs, the error is as below
    *~*~e:\nts_sccm_release\sms\siteserver\sdk_provider\smsprov\sspobjectquery.cpp(6260) : SQL Connection attempt timed out~ SQL Error: [28000][18456][Microsoft][SQL Server Native Client 11.0][SQL Server]Login failed for user 'XXXX\ABBC$'.~*~*
    *~*~SQL Connection attempt timed out [28000][18456][Microsoft][SQL Server Native Client 11.0][SQL Server]Login failed for user 'XXXX\ABBC$'.~*~*
    <*><*> CANT CONNECT TO SQL, RETURNING ERROR <*><*>
    Regards
    Leela

    Duplicate post.
    https://social.technet.microsoft.com/Forums/en-US/6b26502b-ac07-426c-abe4-6cfdaa45b33b/sccm-console-launch-fails-sql-connectivity-issue-with-sccm-machine-account?forum=configmanagergeneral
    Garth Jones | My blogs: Enhansoft and
    Old Blog site | Twitter:
    @GarthMJ

  • SQL 2012 Enterprise SP1 installation for SCCM 2012 R2

    I am just starting to install SQL 2012 with SP1 Enterprise for SCCM 2012 R2.
    Does anyone have a step by step guide for this install please
    I am planning to install SQL 2012 with SP1 Enterprise as a physical install which I intend to geo cluster later on
    Also I am thinking of installing WSUS on a separate server and get my SCCM 2012 servers (1 primary and 3 secondary) to use this server - would appreciate some help on how this can be setup as well

    That doesn't make sense to me. Both versions are fully supported on virtual and physical platforms.
    Also, I'm with Garth - local SQL all the way.
    Here are my thoughts on the subject
    http://www.gerryhampsoncm.blogspot.ie/2013/10/configmgr-sql-some-tips.html
    ConfigMgr is not a real-time product like Exchange, for example. A certain amount of downtime can be tolerated. I would spend more time implementing a robust backup solution, rather than trying to implement high availability.
    You should be able to recover a ConfigMgr site from SQL backup in a couple of hours.
    Gerry Hampson | Blog:
    www.gerryhampsoncm.blogspot.ie | LinkedIn:
    Gerry Hampson | Twitter:
    @gerryhampson

  • How to Custom Report using sql server report builder for SCCM 2012 SP1

    Hi ,
    I am new to database, if i want to create a manual report using sql server report builder for SCCM 2012 SP1, what step should i take.
    i want to create a report in which computer name, total disk space, physical disk serial no come together. i already added class (physical disk serial no.) in hardware inventory classes. refer snapshot

    Hi,
    Here is a guide on how to create custom reports in Configuration Manager 2012, it is a great place to start, change to the data you want to display instead.
    http://sccmgeekdiary.wordpress.com/2012/10/29/sccm-2012-reporting-for-dummies-creating-your-own-ssrs-reports/
    Regards,
    Jörgen
    -- My System Center blog ccmexec.com -- Twitter
    @ccmexec

  • Unable to install Cumulative Update 2 for SCCM 2012 R2

    Hi,
    I am trying to install the CU2 update for SCCM 2012 R2 and I am getting the following error during prerequisite checks:
    Server update status: This update applies to product version 5.0.7958. The installed version on this computer is 5.0.7804.1000. This update is not applicable to this computer.
    Console update status: No serviceable configuration manager role was found on the local system.
    Can anyone provide me some guidance or thoughts on how to get to the correct version to install this update?
    Thank you

    You are running 
    ConfigMgr 2012 SP1 – 5.00.7804.1000 - build 7804
    The CU2 you are trying to apply is for SCCM 2012 R2.
    http://www.systemcenterdudes.com/sccm-2012-version-numbers/
    For SP1 the latest CU is CU5 : http://support.microsoft.com/kb/2978017/en-us
    Benoit Lecours | Blog: System Center Dudes

  • Problem to generat an report on an SSRS for SCCM 2012 R2 SP1. I got error has occurred during report processing.

    Hi,
    Problem to generat an report on an SSRS for SCCM 2012 R2 SP1. I got error has occurred during report processing.
    In general it is no problem to generat SSRS reports, but an custom one i get issue with.
    The Error:
    An
    error has occurred during report processing. (rsProcessingAborted)
    Query
    execution failed for dataset 'DataSet1'. (rsErrorExecutingCommand)
    ExecuteReader:
    CommandText property has not been initialized

    Hi SaiTech,
    According to your description, when you render report on SCCM 2012 R2, you got the error message.
    According to my knowledge, the issue can be caused by following reasons:
    Select permission not granted to ConfigMgr reporting account. We need to open the SQL management console and open the properties dialog box of configmgr db, grant select and execute permission to ConfigMgr reporting account.
    Reporting Services Web Service URL or Report Manager is false. Make sure Web Service URL and Report Manager URL are correct. Restart SMS_Executive service and reinstall Reporting Service Point, then please render the report again.
    Report timeout. Increase query and report timeout.
    If the problem remain unresolved, please provide detailed information of SRSRP.log (default location: %programfiles%\Microsoft  and Configuration Manager\Logs) and reporting services error log(default location: %programfiles%\Microsoft SQL Server\<SQL
    Server Instance>\Reporting Services\LogFiles), it will help us move more quickly toward a solution.
    If you have any more questions, please feel free to ask.
    Thanks,
    Wendy Fu
    If you have any feedback on our support, please click
    here.
    Wendy Fu
    TechNet Community Support

  • Using a custom certificate store for SCCM 2012 clients and primary site server

    I have read what seems to be all the pki related documentation out there for SCCM 2012. I have a PKI infrastructure up and running issueing certificates with an offline root through group policy autoenrollment. The problem that i'm faced with is we are migrating
    from SCCM 2007 that was in native mode and we chose not to use the CA that we used for the old SCCM environment. When the clients attempt to communicate with the M.P. it runs through all of the different certificates and adds a tremendous amount of overhead
    to the M.P. We will have ten's of thousands of clients by migration end. Could someone please point me to a document that goes over how to leverage a custom certificate store that I could then tell the new 2012 environment to use? I know that it's in there,
    I've seen it in the console. The setup is one primary site server with SQL on box and the pki I just mentioned as well as the old 2007 environment that is still live.
    I read that you can try and use SAN as a method of identifying the new certs but I haven't found a good document covering exactly how that works. Any info you could provide I would be very grateful for. Thanks.

    Jason, thank you for your reply. I'm getting the impression that you have never been in the situation where you had to deal with 2 different PKI environments. Let me state that I understand what your saying about trust. We have to configure the trusted root
    CA via GPO. That simply isn't enough, and I have a valid example to backup this claim. When the new clients got the advertisement and began the ccmsetup process I used the /pki switch among others. What the client end up doing was selecting a certificate that
    had the longest validity period which was issued by our old CA. It checked the authentication chain, found it to be valid and selected it for communication. At that point the installation failed, period, no caveats as you say. The reason the install failed
    because the new PKI infrastructure is integrated into the new environment, and the old is not. So when you said " that
    are trusted and they can use *any* cert that is trusted because at the end of the day, there is no
    difference between two valid certs that have the same purpose as long as they are trusted. "
    that is not correct. Both certs are trusted, and use the same certificate template, but only one certificate would allow the install to complete successfully.
    Once I started using the CCMCERTISSUERS
    switch the client install went swimmingly. The only reason I'm still debating this point is because someone might read this thread see your comments and assume "well I've got my new PKI configured as a trusted root CA, I should be all set" and their
    deployment will fail, just as my pilot did.
    About Intune I'm looking forward to doing a POC in the lab i built with my Note 3. I'm hoping it goes well as I really want to have our MDM migrated into ConfigMgr... I think the
    biggest obstacle outside of selling it to management will be the actual device migration from the current MDM solution. From what I understand of the enrollment process manual install and config is the only path forward.
    Thanks Jason for your post and discussion.

  • How to setup IPV6 boundary for SCCM 2012 R2 Primary Site?

    How to setup IPV6 boundary for SCCM 2012 R2 Primary Site?
    I have Direct Access implemented in my environment. I have Windows 8.1 machine connecting through direct access.
    I want to manage the windows 8.1 through SCCM. How do I setup IPV6 boundary. Can someone guide me through?
    Below are the Windows 8.1 client IP Configuration
    C:\Windows\system32>ipconfig
    Windows IP Configuration
    Wireless LAN adapter Local Area Connection* 3:
       Media State . . . . . . . . . . . : Media disconnected
       Connection-specific DNS Suffix  . :
    Wireless LAN adapter Wi-Fi:
       Connection-specific DNS Suffix  . : home
       Link-local IPv6 Address . . . . . : fe80::7466:11a5:39ed:ffb0%4
       IPv4 Address. . . . . . . . . . . : 192.168.1.5
       Subnet Mask . . . . . . . . . . . : 255.255.255.0
       Default Gateway . . . . . . . . . : 192.168.1.1
    Tunnel adapter isatap.home:
       Media State . . . . . . . . . . . : Media disconnected
       Connection-specific DNS Suffix  . : home
    Tunnel adapter Teredo Tunneling Pseudo-Interface:
       Connection-specific DNS Suffix  . :
       IPv6 Address. . . . . . . . . . . : 2001:0:5ef5:79fd:1494:1339:93d6:439c
       Link-local IPv6 Address . . . . . : fe80::1494:1339:93d6:439c%9
       Default Gateway . . . . . . . . . :
    Tunnel adapter iphttpsinterface:
       Connection-specific DNS Suffix  . :
       IPv6 Address. . . . . . . . . . . : fd64:fc00:d17b:1000:e1a7:9cc8:c3c7:d819
       Temporary IPv6 Address. . . . . . : fd64:fc00:d17b:1000:206c:f857:ddbe:2f2b
       Link-local IPv6 Address . . . . . : fe80::e1a7:9cc8:c3c7:d819%10
       Default Gateway . . . . . . . . . :
    Below are the IPConfiguration details for Direct Access server
    C:\Windows\system32>PsExec.exe \\MURA01 ipconfig
    PsExec v1.98 - Execute processes remotely
    Copyright (C) 2001-2010 Mark Russinovich
    Sysinternals - www.sysinternals.com
    Windows IP Configuration
    Ethernet adapter Ethernet:
       Connection-specific DNS Suffix  . :
       IPv6 Address. . . . . . . . . . . : fd64:fc00:d17b:3333::1
       Link-local IPv6 Address . . . . . : fe80::b1ad:1c29:b4a:9125%15
       IPv4 Address. . . . . . . . . . . : 10.192.1.25
       Subnet Mask . . . . . . . . . . . : 255.255.255.0
       Default Gateway . . . . . . . . . : 10.192.1.1
    Tunnel adapter Teredo Tunneling Pseudo-Interface:
       Media State . . . . . . . . . . . : Media disconnected
       Connection-specific DNS Suffix  . :
    Tunnel adapter isatap.{3D6A5E86-D85A-46C8-B69B-FFCF6D5D849C}:
       Connection-specific DNS Suffix  . :
       IPv6 Address. . . . . . . . . . . : fd64:fc00:d17b:1:0:5efe:10.192.1.25
       Link-local IPv6 Address . . . . . : fe80::5efe:10.192.1.25%18
       Default Gateway . . . . . . . . . :
    Tunnel adapter 6TO4 Adapter:
       Media State . . . . . . . . . . . : Media disconnected
       Connection-specific DNS Suffix  . :
    Tunnel adapter IPHTTPSInterface:
       Connection-specific DNS Suffix  . :
       IPv6 Address. . . . . . . . . . . : fd64:fc00:d17b:1000::1
       IPv6 Address. . . . . . . . . . . : fd64:fc00:d17b:1000::2
       IPv6 Address. . . . . . . . . . . : fd64:fc00:d17b:1000:2552:e9f8:87d3:ed8e
       Link-local IPv6 Address . . . . . : fe80::2552:e9f8:87d3:ed8e%20
       Default Gateway . . . . . . . . . :
    ipconfig exited on MURA01 with error code 0.
    Below are the IPCONFIG Details for SCCM Server:
    C:\Windows\system32>PsExec.exe \\sccm01 ipconfig
    PsExec v1.98 - Execute processes remotely
    Copyright (C) 2001-2010 Mark Russinovich
    Sysinternals - www.sysinternals.com
    Windows IP Configuration
    Ethernet adapter Ethernet:
       Connection-specific DNS Suffix  . :
       Link-local IPv6 Address . . . . . : fe80::9f0:86f9:441d:bc07%12
       IPv4 Address. . . . . . . . . . . : 10.192.1.30
       Subnet Mask . . . . . . . . . . . : 255.255.255.0
       Default Gateway . . . . . . . . . : 10.192.1.1
    Tunnel adapter isatap.{0749E47D-AE0A-4D47-9D37-BDDC848E56F6}:
       Media State . . . . . . . . . . . : Media disconnected
       Connection-specific DNS Suffix  . :
    ipconfig exited on sccm01 with error code 0.
    What will be the IPV6 values to configure boundary?

    Depending on how the clients connect use the IPv6 prefix of their 6to4, Teredo, and/ or IP-HTTPS tunnel. Just keep in mind that it could become a long list...
    My Blog: http://www.petervanderwoude.nl/
    Follow me on twitter: pvanderwoude

  • Any major changes to the database for SCCM 2012 and Reporting?

    I'm in the process of migrating my custom reports from SCCM 2007 to SCCM 2012. I wonder if all the tables / views in SCCM 2007 are the same in SCCM 2012 for my reporting purposes? So far everything I've migrated over appears to work without a problem.
    Orange County District Attorney

    Yes, I know this is an old post, but I’m trying to clean them up. Did you solve this problem, if so what was the solution?
    The SQL schema for SCCM 2012 has been released here.
    https://technet.microsoft.com/en-us/library/dn581978.aspx
    Garth Jones | My blogs: Enhansoft and
    Old Blog site | Twitter:
    @GarthMJ

  • SCCM 2012: enable powershell execution policy for SCCM 2012 console

    Hi,
    I always get stuck settings up the remote sccm 2012 powershell (cd psdrive sitecode:). Maybe not a real sccm 2012 question but Powershell but wonder what steps you take to make it work (it works on our production environment, setting up in a lab always gives
    me headaches, will defintely write the solution down this time :-)).
    Please advise what the steps are in configuring remote powershell for SCCM 2012.
    1.my personal account "Myuser" has admin-rights in sccm 2012
    2.I can open Powershell logged on to the sccm 2012 server then opening sccm 2012 console, connect via powershell
    3.however, when I connect remote to the sccm server, I get the error:
    . : File C:\Users\Myuser\Documents\WindowsPowerShell\Microsoft.PowerShell_profile.ps1 cannot be loaded. The file C:\Use
    rs\MyUser\Documents\WindowsPowerShell\Microsoft.PowerShell_profile.ps1 is not digitally signed. You cannot run this scr
    ipt on the current system. For more information about running scripts and setting execution policy, see about_Execution
    _Policies at http://go.microsoft.com/fwlink/?LinkID=135170.
    4.So I connect to the sccm-server and ask for the execution policy to unrestricted, I get this:
    set-executionpolicy unrestricted
    [Y] Yes  [N] No  [S] Suspend  [?] Help (default is "Y"): y
    Set-ExecutionPolicy : Windows PowerShell updated your execution policy successf
    ully, but the setting is overridden by a policy defined at a more specific scope
    There is no policy which sets any powershell configs.
    Please advise.
    J.
    Jan Hoedt

    Those client settings are only for the actions performed by the ConfigMgr client. Normal PowerShell actions are restricted to the configured execution policy on the machine.
    Have a look at this post:
    http://blogs.msdn.com/b/pasen/archive/2011/12/07/set-executionpolicy-windows-powershell-updated-your-execution-policy-successfully-but-the-setting-is-overridden-by-a-policy-defined-at-a-more-specific-scope.aspx
    My Blog: http://www.petervanderwoude.nl/
    Follow me on twitter: pvanderwoude

  • Hardware Sizing for SCCM 2012 R2

    Hello,
            I need your help to do Hardware Sizing for SCCM 2012 R2 environment (SCCM and SQL on same server) with 1000 clients. I have identified the Vm for this installation,
            Kindly share the RAM, HDD (Partitions for OS, Data, Log etc..) and No.of CPU
    Additionally kindly confirm SQL server 2012 SP1 requires any CU for SCCM 2012 R2 environment.

    Just an example...
    At least 16GB RAM, 2 or more CPUs.
    Basically your HDD configuration depends do you have fast disk or slow disk. HDD has to be fast, Johan has very good examples here:
    http://www.deploymentresearch.com/Research/tabid/62/EntryId/115/Sizing-your-ConfigMgr-2012-R2-Primary-Site-Server.aspx
    SQL Server 2012 SP1 doesn't require any CU for ConfigMgr 2012 R2.

  • Pre-provision TRK for SCCM 2012 R2 client

    Hello,
    Clients have some troubles with establishing trusted relationship with management point, I found this article http://technet.microsoft.com/en-us/library/bb680504.aspx but this for SCCM 2007, where can I find for SCCM 2012 R2?

    Do you have AD extended and is the site information properly published to AD in the System Management container?
    What happens when you manually "push" a client?
    What exactly is the entire command-line you are using to install the client?
    The message above is not about the trusted root key, it clearly shows that MP being communicated with is not in the MPLIST returned. I can't say I've ever seen that before, but it is indicative of some other configuration type error.
    Jason | http://blog.configmgrftw.com
    Hello,
    thank you for your message,
    yes, AD was extended and System Management container has site info,
    I have the same problems with push and manual installation,
    I tried this command (specify key and site server cert and without it): C:\Client\ccmsetup.exe /mp:SCCM /logon SMSSITECODE:CM1 SMSPublicRootKey=<key> SMSSIGNCERT=<path to cert>
    where <key> from a file and cert which was exported from site server.
    Where MPList is stored? We spent much time to solve this problem, even reinstalled SCCM on new servers with new site code but problem is not solved.
    After installation client tries to register on management point but there are errors in the different logs at same time:
    Failed to verify signature of message received from MP using name 'SCCM.contoso.com.'
    Failed to verify message. Sending MP [SCCM] not in cached MPLIST.
    RegTask: Failed to send registration request message. Error: 0x87d00309

  • List of recommended hotfixes/updates for SCCM 2012 R2 agents?

    Hopefully I ask this correctly.
    Is there a list of recommended hotfixes or updates for SCCM 2012 R2 agents?  Things like .Net or WMI updates.
    I am seeing the occasional agents lose connectivity, and I want to make sure I have a complete or recommended list of non-SCCM hotfixes before I move forward.
    Thanks!
    Andy

    To my knowledge there aren't really any kind of recommended hotfixes to apply before a client installation, except for the prerequisites (that the client installs by itself). But as a best practice, always make sure that a client is up to date when it comes
    to patches.
    Regards,
    Nickolaj Andersen | www.scconfigmgr.com | @Nickolaja

Maybe you are looking for

  • How Can i Set up my Hotmail Account on Mail ?

    i Want to use my hotmail accont on mail, but i dont know the server ?

  • Splitting events for the ipod

    is it possible to have each event show as a separate folder for the ipod. at the moment, all the photos i have come under the main library, they are not distinguished under the events they are put under on my mbp. any ideas? thanks.

  • Info structures update

    Hi! I'm new to info structures (I'm otherwise ABAPer) and I'm probably not posting this question on the right forum. If so, please redirect me. Anyway, here's the question: How do I set an info structure to be filled with data on certain actions? My

  • Src/application.cpp/error-3685 in Premiere Pro CC

    Please help. I have a file that originates from CC that no longer works when I try to open it. I get the error stated above. None of the auto-save files work either. When I try to open my file, it seems to load properly, but then all I get is a blank

  • Problems with downloading OCS single box win32 version

    I'm trying to download OCS single box win32 and seem to have a problem with the disk2 download. (win32_ocs_90411_singlebox_Disk2.zip). The download is finishing with an incorrect size and the result is (of course) that i can't unzip the download. The