Hello Portal experts,
we have SAP EHP4 ERP system (only ABAP stack).
In order to use some SRM functionality we installed SAP EP (EHP1) and creates a appropriate system object within portal.
We use a  Webdispatcher, so we have to replace within WAS area the local address by the address of Webdispatcher and appropriated port (webserver:567).
The tests of this system object looks as follows:
The address of http://webserver:567 can be retrieved
The problem are the results of following tests:
http://webserver:567/sap/bc/ping
http://webserver:567/sap/bc/webdynpro
These errors occured because the both pathes /sap/bc/ping and /sap/bc/webdynpro do not exist on Portal/Java engine.
Questions:
How can we connect ABAP backend to Portal with extra Webdispatcher?
What are the setting within WAS area?
kind regards

Hi Thom,
Is your webdispatcher in front of your portal? or in front of the ICM of your Backend System?
If the applications that you want to enable via your EP are of the type: WD for ABAP, BSP, IAC or ITS then you should also have a webdispatcher in front of your Backend System (in addition to on in front of your portal).
Please check the following link:
http://help.sap.com/saphelp_nw70ehp1/helpdata/en/48/9a9a6b48c673e8e10000000a42189b/frameset.htm
On this page, scroll down to the last example. Although the image is there to explain "High Availability of the SAP Web Dispatcher" it gives you a good view on the request respond steps.
One rule of thumb is that the EP system itself doesn't act as a reverse-proxy. In other words, if an iView points to a WD 4 ABAP application on the Backend then the actual WD4ABAP application is rendered in an iFrame.
From a technical/connection point of view the client (browser) has 2 connections, one to the EP and 1 tot the Backend.
Allot of people do not realize this when they start there project...
Cheers, hope this helps you a bit....
B

Similar Messages

  • BI System Object in Portal

    Hi everyone,
    I'm trying to to display a BI Report in the Portal. Both systems are on NW04s.
    The connection test of the BI system object fails with the following error:
    SAP Web AS Connection
      Test Details:
    The test consists of the following steps:
    1. Check the validity of the system ID in the system object
    2. Check whether the system can be retrieved
    3. Check whether a SAP system is defined in the system object
    4. Validate the following parameters: WAS protocol; WAS host name
    5. WAS_AND_ITS_CONNECTION_TEST_DETAILS_RESOLVE_NAME
    6. WAS_AND_ITS_CONNECTION_TEST_PING_SERVER_DETAILS
    7. WAS_CONNECTION_TEST_DETAILS_PING_SERVICE
    8. Check HTTP/S connectivity to the defined backend application
      Results
    1. The system ID is valid
    2. Retrieval of the system was successful
    3. The system object represents an SAP system
    4. The following parameters are valid: Web AS Protocol (http) Web AS Host Name (hvrz0afa.hvr.sbs.de:8011)
    5. WAShvrz0afa.hvr.sbs.deCONNECTION_TEST_HOSTRESOLVE_RESULT_PASS
    6. WAShvrz0afa.hvr.sbs.deAND_ITS_CONNECTION_TEST_PING_SERVER_FAIL
    I have done all system settings for connector, WAS and ITS.
    The test connection with connector was successful.
    What could be the problem?

    Hi,
    Can you please send the values you have set for the ITS related parameters ?
    Secondly, the test connection results are not reliable. I would rather request you to create a BW report iview and then use this system and check if you are able to see the report ( or get the username & password screen if the SSO is not configured or user is not mapped). This would atleast confirm that the ITS has been configured properly. If it gives an error, then we can make the necessary changes.
    Cheers,
    Sunil
    PS: Reward points for helpful answers.

  • How to create a system object in portal that points to a web dispatcher

    Hi,
    How do we create a system object in the portal for a web dispatcher? The web dispatcher in turn points to an ECC system. The path for communication is EP>Web Dispatcher>ECC
    Regards,
    Sridevi

    Hi,
    Connection test for the following succeeded:
    1. SAP Web AS Connection
      Test Details:
    The test consists of the following steps:
    1. Checks the validity of system ID in the system object.
    2. Checks if the system can be retrieved from the PCD.
    3. Check whether a SAP system is defined in the system object
    4. Validate the following parameters: WAS protocol; WAS host name
    5. Checks if the host name of the server can be resolved.
    6. Pings the WAS ping service; works only if the service is activated on the ABAP WAS.
    7. Checks HTTP/S connectivity to the defined back-end application
      Results
    1. The system ID is valid
    2. The system was retrieved.
    3. The system object represents an SAP system
    4. The following parameters are valid: Web AS Protocol (http) Web AS Host Name (mtw02spwp02:80)
    5. The host name mtw02spwp02 was resolved successfully.
    6. The Web AS ping service http://mtw02spwp02:80/sap/bc/ping was not pinged successfully. If the ping service is not activated on the Web AS, you can try to call the ping service manually.
    7. An HTTP/S connection to http://mtw02spwp02:80/sap/bc/bsp/sap was obtained successfully.
    2. ITS Connection
      Test Details:
    The test consists of the following steps:
    1. Checks the validity of system ID in the system object.
    2. Checks if the system can be retrieved from the PCD.
    3. Check whether the system object has a valid system alias
    4. Check whether a SAP system is defined in the system object
    5. Validate the following parameters: ITS protocol; ITS host name
    6. Checks if the host name of the server can be resolved.
    7. Checks HTTP/S connectivity to the defined back-end application
      Results
    1. The system ID is valid
    2. The system was retrieved.
    3. Retrieval of the default alias was successful
    4. The system object represents an SAP system
    5. The following parameters are valid: ITS Protocol (http) ITS Host Name (mtw02spwp02:80)
    6. The host name mtw02spwp02 was resolved successfully.
    7. An HTTP/S connection to http://mtw02spwp02:80/sap/bc/gui/sap/its/webgui was obtained successfully.
    Next test for SSO failed:
    Test Connection with Connector
      Test Details:
    The test consists of the following steps:
    1. Retrieve the default alias of the system
    2. Check the connection to the backend application using the connector defined in this system object
      Results
    Retrieval of default alias successful
    Connection failed. Make sure that Single Sign-On is configured correctly
    Regards,
    Sridevi

  • Defining SID system object in Portal

    Hi!
    Can some one please tell me how to define a <SID> system object SAP ECC 6.0 ABAP system in Portal?
    What are the technical steps (tools and files)?
    What are the prerequisite to be met?
    Any helpful information will be very appreciated!
    Thank you very much!
    Thom

    Covered many times in the forums, Thom. Please search for note 761917 for examples etc.

  • Cant see the option to login as microsoft account on system after windows 8 was refreshed with 8.1

    My system came with Windows8 installation. And I created my windows account on this. 
    Later it prompted for 8.1 update and I went with that.
    After 8.1 got installed, I also created my local account. 
    I logged in as local account (also admin account) and then logged out. first issue came as system errored out once I tried to login as microsoft account now. I dont know why.. It was not wrong password error. It just said error logging into microsoft account
    Now I do not see an option to login as microsoft account. PLease note, I do not even see this listed in user accounts.
    There are other issues too, like for every folder, I need to specifically provide admin access even if I am logged in as local administrator account. But I am fine with these issues.Obviously, they irritate :). 
    But I would like to resolve the microsoft account issue first.. HOw do I get it back .. 

    Hi,
    Please check your Microsoft Account status in User Account Manager:Control Panel\User Accounts\User Accounts
    In addition, please access to the path of registry to check your Microsoft Account if it locate there.
    HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows NT\CurrentVersion\ProfileList.
    If problem persists, the workaround method may be need you delete and readd your Microsoft Account on your computer.
    Roger Lu
    TechNet Community Support

  • Re: Error in System Object in Portal

    Hi Experts,
    I have created a system and have given values for all the property category
    1.WAS
    2.ITS
    3.Connector
    1.when I do the connection test for ITS, I'm getting error saying
    "User mapping is not valid
    HTTP/S connection failed"
    2.when I do the connection test for Conectors, I'm getting the error saying
    "Connection failed. Make sure user mapping is set correctly and all connection properties are correct."
    Help me to resolve the issue.
    I guess there is problem in values for ITS and Connector property category so I have the following doubts
    1.How to find the ITS host name?
    2.How to find the ITS path?
    Useful answers will be rewarded.
    Thanks in Advance,
    Suba

    Generally I don't worry about error messages in the test tool!  Instead, I try to create a transaction iView and see if that works. That's the important test.
    Cheers

  • Error while creating a system object for R3 in portal

    Hi,
    I am getting error while trying to create a system object in portal.
    Following are the details I used :
    Under WAS...
    Web AS Host Name :<XXXX>:8001
    Web AS path: /sap/bc/bsp/sap/
    Web AS protocol : http
    Under User management:
    Authentication Ticket Type : SAP Logon Ticket
    Logon Method :SAPLOGONTICKET
    User Mapping Type : admin,user
    Under Connector:
    SAP Client : <Client NO>
    SAP System ID : <System ID>
    SAP System No : <System No>
    System Type : SAP_R3
    While trying with connection test... I am getting like this:
    SAP Web AS Connection
      Test Details:
    The test consists of the following steps:
    1. Checks the validity of system ID in the system object.
    2. Checks if the system can be retrieved from the PCD.
    3. Check whether a SAP system is defined in the system object
    4. Validate the following parameters: WAS protocol; WAS host name
    5. Checks if the host name of the server can be resolved.
    6. Pings the server to see if it is alive.
    7. Pings the WAS ping service; works only if the service is activated on the ABAP WAS.
    8. Checks HTTP/S connectivity to the defined back-end application
      Results
    1. The system ID is valid
    2. The system was retrieved.
    3. The system object represents an SAP system
    4. The following parameters are valid: Web AS Protocol (http) Web AS Host Name (<FQDN server name>:8001)
    5. The host name <FQDN Server Name> was resolved successfully.
    6. The server sapdwh01 could not be pinged successfully.
    Test Connection with Connector
      Test Details:
    The test consists of the following steps:
    1. Retrieve the default alias of the system
    2. Check the connection to the backend application using the connector defined in this system object
      Results
    Retrieval of default alias successful
    Connection failed. Make sure that Single Sign-On is configured correctly
    It seems that the portal is not able to ping to R3 system. I tried to ping to R3 server from portal server by command prompt. I am able to ping. Also under SICF, I can see ping service as in activated state.
    Kindly help.
    Regards,
    Niraj
    Edited by: Niraj Kumar on Dec 11, 2008 10:41 AM

    I created a SAP Transactional iView for transaction SE80.
    Also, I tried from under System Administration -> Support -> SAP Transaction. It is not working.
    Got portal Runtime error :
    Portal Runtime Error
    An exception occurred while processing your request
    Exception id: 12:57_11/12/08_0003_2795650
    See the details for the exception ID in the log file.
    Regards,
    Niraj

  • System object with same credentials for all users?

    Hi everyone
    I would like to create a system object in Portal, which can be used by users in a specific group. However, I want all users to use the same credentials for this system. Is this possible?
    I've tried creating systems, but they all seem to require user mapping to work correctly. Is there some way I can create a system object with the credentials as part of the object, and then just assign permissions to it as required?
    Please let me know if this raises any questions.
    Thanks
    Stuart

    i dont think it is possible to create a system object for all the users with same credentials.anyways you are trying to create system object for some users who belong to a particular group.so you need to do only one time user mapping for that group
    go to user administration-search for the group-go to user mapping tab-give username and password..
    reward points if helpful

  • PO No range when we ink two SRM system with One ECC system

    Hello Experts,
    We have a client requirement to link Two SRM Systems with One ECC system.
    In this case what number range we need to maintain in both SRM systems for PO.
    -The number range of ECC PO should get update whenver the PO is transferred from any of the two SRM system.
    -We have Extended classic scenario.
    -Also PO Doc type is going to be same.
    Can we handle this by increasing the buffer of the number range in one of the SRM system?
    Any idea...pls help urgently.
    Best Regards,
    Anil
    Edited by: anil.s.verma on Oct 1, 2010 4:33 PM

    Hello Anil,
    Being in Extended Classic Scenario (leading PO being in SRM, R/3 PO number range is concidered as external because PO number is given by SRM), the only solution for you is to:
    1- give same number range interval for PO (internal in SRM system 1 and SRM system 2, external number range in R/3), e.g. 3100000000 - 3199999999
    2- in SRM system 2, fill in current number with (for example) 3159999999 and let empty (or current value) in SRM system 1
    3- assign, in each system for your concerned transaction type, number range as internal in SRM and external in R/3.
    In this way, you will avoid overlaping in R/3 between PO numbers coming from SRM system 1 and SRM system 2
    Regards.
    Laurent.

  • Problem in System object - Very urgent - Pls help

    Hi ,
    I have installed Portal version SP9 on windows with MS SQL server as database . I am experencing some
    issues during the system object creation for R3 . Below I will specify all the configuration I have done for
    system object creation ,
    1. I have selected the option Dedicated application server for R/3 system .
    2. Under th eproperty category , I have selected Connector and put the following values .
    Application Host  - 128.1.7.2
    Remote Host Type - Select -3
    SAP Client  - 120
    SAP System ID (SID)- DV1
    SAP System Number - 00
    System Type - SAP_R3
    Trace Mode - Select -01
    3 . Then Under the property category , Web Application server ( WAS ) I have selected
    the following properties .
    WAS hostname - 128.1.7.2
    Was Protocol - http
    4 . Next step I have selected the User Management and put the below details
    Logon Method - UIDPW
    usermapping type - admin ,user
    4. I have also created an alias and made it default
    6. Then I have gone to usermapping under the user administration and created the
    user mapping for the user .
    But when I have tested the system object , I am getting the following error .
    SAP Web AS Connection - Jan 1, 1970 8:17:25 AM
      Test Details:
    The test consists of the following steps:
    1. Check that the system object defines an SAP system
    2. Validate the following parameters: wap.WAS.protocol; wap.WAS.hostname
    3. Check the HTTP/S connection to the defined backend application
      Results
    1. The system object represents an SAP system.
    2. The following parameters are valid: wap.WAS.protocol (http) ; wap.WAS.hostname (128.1.7.2)
    3. HTTP/S connection failed. Make sure the protocol, host name, and user mapping are correctly defined.
    ITS Connection - Jan 1, 1970 8:17:25 AM
      Test Details:
    The test consists of the following steps:
    1. Check that the system object defines an SAP system
    2. Validate the following parameters: wap.ITS.path; wap.ITS.protocol; wap.ITS.hostname
    3. Check the HTTP/S connection to the defined backend application
      Results
    1. The system object represents an SAP system.
    2. The following parameters are not valid: wap.ITS.path () ; wap.ITS.protocol () ; wap.ITS.hostname ()
    I really dont know what is foing wrong . Do I need to omit the WAS details which I have mentioned in the step number 3 . What is the
    real use of this step ? Could any body guide me as this is quite urgent
    Thanks
    Aneez

    Hi,
      We have similar setup and having same userids in both R/3 (webas 6.40 based) as well as
    in EP 6.0, so we are not doing any user mapping as recommended. I hope i gave all necessary
    parameters under system object of categories user management with SAPLOGON, connector
    properties and also WAS properties with hostname and type as http. When i try to do test
    connection it is giving following error message:
    SAP Web AS Connection - 
      Test Details:
    The test consists of the following steps:
    1. Check that the system object defines an SAP system
    2. Validate the following parameters: wap.WAS.protocol; wap.WAS.hostname
    3. Check the HTTP/S connection to the defined backend application
      Results
    1. The system object represents an SAP system.
    2. The following parameters are valid: wap.WAS.protocol (http) ; wap.WAS.hostname (xxxxxxxx)
    3. HTTP/S connection failed. Make sure the protocol, host name, and user mapping are
    correctly defined.
    Test Connection with Connector - Jan 1, 1970 6:40:19 PM
      Test Details:
    The test consists of the following steps:
    1. Retrieve the default alias of the system
    2. Check the connection to the backend application using the connector defined in this
    system object
      Results
    Retrieval of default alias successful
    Connection successful
    Also when i try to do the testing of transaction from :
    System Adm.>Support.>SAP Application>SAP transaction>
    Select the system and Tcode and most important SAP GUI type = SAP GUI for Windows
    i am getting connection broken error.
    Let me know is there anything in specific which is missing.
    Thanks

  • Get statuses of SC items - SAP SRM system

    Hello guys
    I would like to ask you for help.
    Let suppose following situation in SAP SRM system
    Approver received SC (shopping cart) with 2 items for approval. He marked first item as rejected, second one as approved. Then clicked submit.
    I need to add a piece of a code to the code which handle click on the button submit. In this code I need to know which items were rejected. I tried to insert the code to implementation of the interface method
    IF_EX_BBP_DOC_CHANGE_BADI~BBP_SC_CHANGE.
    I used method
    /sapsrm/cl_pdo_factory_sc_adv=>get_instance
    which returns object
    ro_instance
    and then I called object's method
    /sapsrm/if_pdo_do_apv_ext~get_process_info
    which return structure
    ls_wf_info
    In this structure I was only able to find requested information (states for each item of SC) only when no operation was done on SC (it means only after code, which handle clicking on submit button, was executed).
    Can somebody help me how to get information for each item of SC?
    Edited by: jozef.gloncak on Jan 18, 2012 2:28 PM

    Hello Jozef,
    we have the same problem.
    Can you provide your solution for the problem?
    Thank you in advance.
    Regards,
    Florian

  • Determine linked SRM system in ECC

    Hi All,
    I need to be able to determine the linked SRM system from ECC in order to call a function module in SRM to return the URL for SRM to ECC to allow a workitem in ECC to contain a link to SRM.
    Table BBPC_RFC_DEST seems to hold a link but I've never seen this table used, does anyone know what this table is used for? The config help says:
    Definition of RFC Connections for Resource-Related Billing
    Use
    In this IMG activity, you define which connected SRM Systems are relevant for resource-related billing.
    Enter the logical system and the RFC destination.
    Requirements
    The connected SRM System must be Release 5.0 or higher.
    but would populating this table alone activate something else?
    Alternatively does anyone else have any other suggestions for retreiving the URL for SRM from ECC other than creating a custom table to hold the information.
    Regards
    Chris

    Hi all,
    perhaps I need to clairfy my question.
    I know how to find the URL in SRM, my requirement is to be able to work out the URL of the linked SRM system from within ECC.
    I have a couple of ideas such as call a function mdoule in SRM to read the user arrtibutes which will give me the URL for system. To do this I need to first determine the RFC destination for the linked SRM system, I think I can do this by populated table BBPC_RFC_DEST in ECC. However I sdon't know if popualtign this table in ECC will have any other implications?
    Does anyone know what the implications of populating table BBPC_RFC_DEST in ECC arE?
    or does anyone have an alternative soltuion for determining the URL for the linked SRM system from within ECC?
    Regards
    Chris

  • I am selling my Mac Mini. I recently purchased OS X Lion. When I restore to factory settings, how can I ensure that the operating system will still be Lion, and not the original operating system, which I believe was Snow Leopard?

    I am selling my Mac Mini. I recently purchased OS X Lion. When I restore to factory settings, how can I ensure that the operating system will still be Lion, and not the original operating system, which I believe was Snow Leopard?

    If you bought Lion from the App Store, you can't legally or practically transfer it, because it's tied to your Apple ID. Reinstall the original software from the discs that came with the machine.

  • PortalRuntimeException in Business Object document iview No portal component associated with the following context

    Hi all,
    We are stumped with a problem in our QA Enterprise Portal (7.3.1 Sp7) that throws a portal runtime error when we preview a Business Objects document iview.  The Business Objects Server versions are 4.0 SP5 and/or 4.1 SP3.
    The error is caught in the the defaultTrace file, /usr/sap/QNW/J00/j2ee/cluster/server0/log
    [EXCEPTION]
    com.sapportals.portal.prt.runtime.PortalRuntimeException: There is no portal component associated with the following context:
    pcd:portal_content/com.summit.SES_BI/com.summit.iviews/Daily_Margin
    at com.sap.portal.prt.component.PortalComponentContext.<init>(PortalComponentContext.java:93)
    Here is what we have tried
    * Confirmed the iviews exist in the PCD, by browsing to the content folders and right lick, preview on the iview.
    * Our PRD and DEV systems work correctly and are on same versions of EP Runtime and java. 7.3.1.7.0.201..
    * Occurs with all Businessobjects iviews from the QA portal and all doc types, webis, dashboards. Tried creating new iview.
    * Reapplied the com.sap.businessobjects.iviews.templates.epa to the Portal from t he BI 4.1 SP3 distribution
    * Deleted and recreated the BI portal system connector using the SAP BOBJ system template set path to http://bi-qas:8080/BOE
    * Set the embed key value in the BI system connector property and in the custom global.properties file, restarted tomcat and SIA services
    * Set permissions for everyone end user on the content folders and the BI system connector
    * Confirmed Single sign on configured correctly between BI and Portal
    * Confirmed that the QA BI server is configured correctly by directing the working DEV Portal to the QA BI server.
    * Performed actions in note 1709737
    We are certainly stuck and the defaultTrace file is not very informative.  Any suggestions are greatly appreciated
    Lee Lewis

    This is resolve with note 1615838  - SAP Netweaver Enterprise Portal 7.3 iView creation with BI 4.0 results in exceptions.
    The note includes a file portalapp.xml that need to be inserted into com.sap.businessobjects.iviews.par that is included in the BI server distribution.
    Then deploy the ear file.....
    Odd thing is that the note mentions 4.0 and we are on 4.1 SP3...
    Environment
    SAP BusinessObjects BI Platform 4.0 SP02 Patch 4 or lower
    SAP Netweaver Enterprise Portal 7.3
    Lee Lewis

  • Problem Create System Object in the Portal for connecting CRM abap

    Hi, i creating system in the portal (JCX) for connecting system ABAP CRM (CRX), after create system try run test connection and show messages error:
    Test Connection with Connector
      Test Details:
    The test consists of the following steps:
    1. Retrieve the default alias of the system
    2. Check the connection to the backend application using the connector defined in this system object
      Results
    Retrieval of default alias successful
    Connection failed. Make sure that Single Sign-On is configured correctly
    In the logs the portal (NWA) show messages:
    Failed in creating the JCO Connection.
    The logs operation system (log Security_audit.log)
    Error> occured  >Thu Jun 23 11:34:41,278<RfcException: message: 'mshost' missing  Return code: RFC_INVALID_PARAMETER(19  Return code: RFC_INVALID_PARAMETER(19)    error group: 101 key: FC_ERROR_PROGRAM
         at com.sap.mw.rfc.api.RfcOptions.checkParameters(RfcOptions.java:438)
         at com.sap.mw.rfc.api.RfcApi.RfcOpen(RfcApi.java:688)
         at com.sap.mw.jco.MiddlewareJRfc$Client.connect(MiddlewareJRfc.java:1079)
         at com.sap.mw.jco.JCO$Client.connect(JCO.java:3256)
    Plase help, any idea?

    message: 'mshost' missing Return
    During the System Object Creating in System Landscape, there is any entry as Message Server Host: CRM MS HOST
    and Message Server Port : sapmsSID and add this entry in etc/services --> bottom samsSID 36NN/tcp where NN is instance number.
    Try this and let me know.
    Thanks
    SM

Maybe you are looking for

  • SharePoint Foundation 2013

    Hi Guys, Is SharePoint Foundation 2013 is like SharePoint Foundation 2010 free? Is SharePoint Foundation 2013 free? Thank you

  • SharePoint 2013 - Asking for password with NTLM

    Hi All, We have deployed a web application using NTLM with single sign on. It's a secure site and in IIS bindings we have SSL certificate attached with this web application. However, many users are keep getting windows authentication prompt as shown:

  • Final Cut Pro Problems! "PLEASE HELP"

    Hi people, I'm having problems with Final Cut Pro and my Camcorder!! Here is the deal: My Mac: iMAc, System 10.5.8, 4GB RAM Final Cut Pro 5.1.4 Camcorder: Sony HDR FX7 Fire Wire Cable The problem... I have wworking with this many months is good way,

  • Problems with a c++ code on a linux pc translate into java windows pc

    Hello does anyone know how I can use this c++ code in my java program. This is a c++ code what we use on a linux pc now I have to make the code for a windows pc with java. void GetLocalIP(int s,struct sockaddr_in *local)    struct ifconf cfg;        

  • Touchsmart All-In-One 310-1125y not powering up