SRW2008 with a 100Base-FX SFP?

i got a 100Base-FX SFP from my localloop provider and tried to use it in a Linksys SRW2008 switch.
it seems the SFP ports are fixed to 1000Base. is there a way around this limitation?
thanks for your help.

Hi
Check  software requirements and configuration requirements in the attached guide.
I think it gives you your answer (I hope )
It suggests you need 1.0.3 software and then try the following;
Manually Configuring the 100M SFP
STEP 1 On the Port Configuration page, click Detail.
STEP 2 In the Port Configuration popup window, select eth 100M in the SFP Speed field.
STEP 3 Save your changes.
STEP 4 Insert the 100M SFP module.
Hope this helps
regards Dave

Similar Messages

  • Issue with LACP on SRW2008 with W2k8

    Hello,
    I'm trying to configure the LACP for W2k8 and I have strange thing :
    My network is :
    1 SRW2008 with
    a Synology NAS connected with LACP
    my PC running under W2k8 with LACP
    1 another PC with single
    1 Router running with DD-WRT fw , used for DHCP , WIFI  and for the internet connexion
    I have a Dual NIC Intel  and the LACP is active on my PC w2k8 , I can see my network connected at 2 Gb/s. I can surf ping the swr2008 , my router and my printer connect by wifi. I cannot ping the other PC and my NAS connected to the srw2008.
    when I disconnect 1 cable of my LACP of my PC I can ping everything
    if I configure w2k8 not with lacp but with ALB I can ping everything
    my question is :
    How to configure LACP 802.3ad on w2k8 and have the ping working to the other system connected to the srw2008 ?
    Thanks a lot
    Emmanuel

    Steve,
    Are you having an issue with incoming or outgoing mail?
    If the issue is with outgoing email this article may be helpful:
    http://docs.info.apple.com/article.html?artnum=305634
    If you are using an IMAP server provided by your employer, you may not be able to access the server without VPN.
    Hope this helps,
    Nathan C.

  • 6509e SUP-2T VSS and 100BASE-X SFP

    Dear All,
    i need to connect via 100BASE-X uplinks some access switches to 6509e VSS distribution Switches having SUP-2T.
    It seems that the only module on 6509e supporting 100BASE-X SFP is WS-X6148-FE-SFP. This module is going EoS and is not supportes in VSS.
    Is there any other modules that i can use?
    Thanks and Regards
    Giuseppe

    Hi,
    Here's a link that contains information about available line cards that might help you:
    http://www.cisco.com/en/US/prod/collateral/switches/ps5718/ps708/product_data_sheet0900aecd801459a7.html
    Regards,

  • 100BASE-BX10 SFP

    Hi All,
    I have several Cisco 3560C setup at multiple stations. The Cisco 3560C are connected in a daisy chain between each other using 100BASE-BX10-D and 100BASE-BX10-U SFP. So, on the first Cisco 3560C (station 1), I have a U-type connecting to the second Cisco 3560C (station 2.). The second Cisco 3560C (station 2) will have a D-type and U-type SFP where the D-type connects to the previous station 1 on its U-type SFP. This setup repeats for station 3 onwards.
    It seems that these connections between the stations, I noticed that the Cisco switch registers the link at 100Mb half-duplex and I see incrementing CRCs and collisions. I am not able to hard-code the interface to 100Mb FULL as it seems that the interface configuration does not give me the option to do a 'speed 100' or 'duplex full'.
    Is this normal for these kinds of SFP?
    Below are some outputs:
    Cisco IOS Software, C3560C Software (C3560c405-UNIVERSALK9-M), Version 12.2(55)EX3, RELEASE SOFTWARE (fc2)
    Technical Support: http://www.cisco.com/techsupport
    Copyright (c) 1986-2011 by Cisco Systems, Inc.
    Compiled Wed 10-Aug-11 07:37 by prod_rel_team
    Image text-base: 0x00003000, data-base: 0x02100000
    Switch(config)#do sh int status
    Port      Name               Status       Vlan       Duplex  Speed Type
    Fa0/1                        notconnect   15           auto   auto 10/100BaseTX
    Fa0/2                        notconnect   15           auto   auto 10/100BaseTX
    Fa0/3                        notconnect   15           auto   auto 10/100BaseTX
    Fa0/4                        notconnect   15           auto   auto 10/100BaseTX
    Fa0/5                        connected    15         a-full  a-100 10/100BaseTX
    Fa0/6                        notconnect   15           auto   auto 10/100BaseTX
    Fa0/7                        notconnect   15           auto   auto 10/100BaseTX
    Fa0/8                        notconnect   15           auto   auto 10/100BaseTX
    Fa0/9                        notconnect   15           auto   auto 10/100BaseTX
    Fa0/10                       notconnect   15           auto   auto 10/100BaseTX
    Fa0/11                       connected    trunk      a-full  a-100 10/100BaseTX
    Fa0/12                       connected    trunk      a-full  a-100 10/100BaseTX
    Gi0/1                        connected    trunk      a-half  a-100 100BaseBX-10U SFP
    Gi0/2                        connected    trunk      a-half  a-100 100BaseBX-10D SFP
    Switch#sh interfaces gigabitEthernet 0/2
    GigabitEthernet0/1 is up, line protocol is up (connected)
      Hardware is Gigabit Ethernet, address is c025.5c11.928d (bia c025.5c11.928d)
      Description:
      MTU 1500 bytes, BW 100000 Kbit, DLY 100 usec,
         reliability 254/255, txload 1/255, rxload 1/255
      Encapsulation ARPA, loopback not set
      Keepalive not set
      Half-duplex, 100Mb/s, link type is auto, media type is 100BaseBX-10D SFP
      input flow-control is off, output flow-control is unsupported
      ARP type: ARPA, ARP Timeout 04:00:00
      Last input 00:00:00, output 00:00:00, output hang never
      Last clearing of "show interface" counters never
      Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
      Queueing strategy: fifo
      Output queue: 0/40 (size/max)
      5 minute input rate 80000 bits/sec, 22 packets/sec
      5 minute output rate 16000 bits/sec, 16 packets/sec
         74931 packets input, 21611558 bytes, 0 no buffer
         Received 48734 broadcasts (39982 multicasts)
         0 runts, 0 giants, 0 throttles
         667 input errors, 667 CRC, 0 frame, 0 overrun, 0 ignored
         0 watchdog, 39982 multicast, 0 pause input
         0 input packets with dribble condition detected
         23385 packets output, 3857612 bytes, 0 underruns
         0 output errors, 564 collisions, 1 interface resets
         0 babbles, 29 late collision, 0 deferred
         0 lost carrier, 0 no carrier, 0 PAUSE output
         0 output buffer failures, 0 output buffers swapped out

    Yes scope all connections with a 900 micron 200x scope, and clean anything you can.
    GLC-FE-100BX-U
    100BASE-BX10-U
    -8
    -14
    -3
    -28.2
    GLC-FE-100BX-D
    100BASE-BX10-D
    -8
    -14
    -3
    -28.2
    If its clean, check the TX/RX power levels with a power meters.  End-to-end; bidirectional test, on both lamdas.
    Because of the CWDM going on, I'm not sure I'd trust the internal "show hard" or
    "show interfaces interface-id transceiver detail" internaly.
    Obviously this is something common/systemic since it happens betwen multiple locations.
    Is the fiber the common denominator?

  • Issue with 3560g sfp GLC-SX-MM connect to 2924C

    I have a 3560g switch. Have gig sfp interface [GLC-SX-MM=] and want to connect to to WS-2924C-XL f0/24 fasteth fiber port.
    I have a patch panel in the middle.
    3560g sfp interface [GLC-SX-MM=]   SC   ---------- ST PP  ST   -------------------------   SC  2924C-XL f0/24 fasteth fiber port
    can I make this work? The lights do not come up. The port are configured correctly. I can not hard code the speed on the 3560 int sfp.

    Unfortunately, you can't directly connect a 1GE GLC-SX-MM SFP interface to a 100Base-FX interface.  You will need to swap the SFP on the 3560G with a 100Base-FX SFP (GLC-FE-100FX).
    Cisco 100-Megabit Ethernet SFP Modules  Compatibility Matrix
    <http://www.cisco.com/en/US/docs/interfaces_modules/transceiver_modules/compatibility/matrix/OL632702.html>
    Hope this helps.
    Tom

  • 8 port poe with 2 SFP 1gig uplink port

    I need a 8 port poe switch  (LAn base) with 2 X 1gig SFP uplink.  can anyone suggest me the correct model?

    Depending on your budget, you have a choice of FastEthernet or GigabitEthernet ports.
    For FastEthernet ports, WS-C2960C-8PC or WS-C3560C-8PC.
    For GigabitEthernet ports, WS-C3560CG-8PC.

  • SFP with Nexus 5500/2000

    We ordered two 5548P and several 2000. They came with two types of SFPs. One is SFP-10G-SR, the other FET-10G.
    What is FET-10G used for? between 2000 FEX and computer servers?
    thanks,
    Han

    It will show invalid SFP until you enable the fex feature and configure the interfaces/port-channel as fex fabric. You have to use the same on both ends, either FET or 10G-SR.
    example
    feature fex
    interface port-channel101
      description Port channel, vPC 101 to FEX 101 Nexus 2248
      switchport mode fex-fabric
      fex associate 101
      vpc 101
    interface Ethernet1/32
      description Connection to FEX 101 Nexus 2248 Fabric port 1/1
      switchport mode fex-fabric
      fex associate 101
      channel-group 101

  • Is switch HP V1910-24G ''JE006A compatible with cisco components such as power injector and cisco SFP

    Hi everbody,
    I need your hand for this case please :)
    this is first time to design outdoor AP, i will use 1532E due to the price is good, but my question is
    * switch HP V1910-24G ''JE006A'' could be compatible with AIR-PWRINJ-30= & SFP cisco 1 G "glc-sx-mmd"
    I am looking for your advice 

    the power injector will work  but the cisco sfp will not work with the HP switch, also i recommend a switch that is already delivering POE+
     

  • Compatibility with SFP modules

    Hi,
    I have a query, I need connect a Switch 6500 with a switch HP, the switch HP has a HP X242 10 SFP module and need connect to the switch 6500 with a module CVR-X2-SFP10G. I need to know if this modules are compatible.
    Thanks for the help.

    According to the 6500 module installation manual, and a Q&A document,
    "Q. What is the difference between WS-X6716-10G-3C and WS-X6716-10G-3CXL?
    A. Both modules offer 16 ports of 10 Gigabit Ethernet and share the same base board, WS-X6716-10GE. WS-X6716-10G-3C comes with distributed forwarding card 3C (WS-F6700-DFC3C), and WS-X6716-10G-3CXL comes with distributed forwarding card 3CXL (WS-F6700-DFC3CXL)."
    "A sticker is placed on the module faceplate identifying it as either a WS-X6816-10G-2T or WS-X6816-10G-2TXL depending on whether a WS-F6K-DFC4-E or WS-F6K-DFC4-EXL daughter card is installed on the module."
    "Not all 10-GB transceiver versions may be supported on your module. Refer to your software release notes to determine if a specific 10-GB transceiver is supported on your module."
    It seems you will need to determine which daughter card or forwarding card is installed in the base WS-C6716-10GE board; then refer to the software release notes for transceiver compatibility.  The longer reach SFP+ copper or active optical interfaces draw more power, thus they may not be supported with the X2 to SFP+ converter.  

  • SFP+ Compatibility with Nexus 3065-x

    Hi,
    I need to know if the STP-SFP+-LR Wavelenght 1310 10km  from other venders will be compatible with the Cisco Nexus 3065 switch. I know you can run
    switch(config)# service unsupported-transceiver
    switch(config)# no errdisable detect cause gbic-invalid
    My question is will it work?
    Thank you
    Etienne

    From other vendors?  No it won't.
    You can use those two hidden commands but any troubles with your 3rd party SFP+ will not be supported by TAC.
    The reason is because there have been numerous well-documented cases where the 3rd party modules (not made by the big five) is the root of (or part of) the problem.

  • MGBLH1 SFP

    Hello
    mgblh1 gbic support multi-mode and single mode fiber optical.
    62.5/125um MMF @ 200MHz/km, up to 500m
    50/125um MMF @ 500MHz/km, up to 2,000m
    9/125um SMF, up to 40km
    my question is what happen if i use this gbic with single mode wire under 500m between my sge2000p switch.
    thanks

    my question is what happen if i use this gbic with single mode wire under 500m between my sge2000p switch.
    If you already purchased MGBLH1 SFP 9/125um SMF, up to 40km then
    1.Either check optical power and if it is less than -3dBm then use it (Like -4dBm)
    2. If it is more than -3dBm (-2, -1 etc )then use an 5dBm optical attenuator
    3.If not bought can go for single mode 10Km or 2 Km multimode (MGBLX1 1000BASE-LX SFP transceiver, for single-mode fiber, 1310 nm wavelength, support up to 10 km, MFEFX1 100BASE-FX SFP transceiver, for multimode fiber, 1310 nm wavelength, support up to 2 km)
    Depending on your current and future requirement

  • SG200 SFP Compatibility

    Hello,
    We want to connect SG200 to Catalyst 2960X via optical fibre. Now on our SG200 (SG200-50P-K9-EU) switches are using D-Link DEM-311GT SFP modules.
    We found module Cisco GLC-SX-MMD, that is compatible with Catalyst series switches, but there's no info about Small Business series. Someone has tried to run this module on Cisco SB?

    Hello,
    SG200 series support these SFP:
    http://www.cisco.com/c/en/us/products/collateral/switches/small-business-100-series-unmanaged-switches/data_sheet_c78-634369.html
    Product Ordering Number
    Description
    MFE Transceivers
    MFEBX1
    100BASE-BX-20U SFP transceiver for single-mode fiber, 1310 nm wavelength, supports up to 20 km
    MFELX1
    100BASE-LX SFP transceiver for single-mode fiber, 1310 nm wavelength, supports up to 2 km
    MFEFX1
    100BASE-FX SFP transceiver for multimode fiber, 1310 nm wavelength, supports up to 10 km
    MGE Transceivers
    MGBBX1
    1000BASE-BX-20U SFP transceiver for single-mode fiber, 1310 nm wavelength, supports up to 40 km
    MGBLH1
    1000BASE-LH SFP transceiver for single-mode fiber, 1310 nm wavelength, supports up to 40 km
    MGBLX1
    1000BASE-LX SFP transceiver for single-mode fiber, 1310 nm wavelength, supports up to 10 km
    MGBSX1
    1000BASE-SX SFP transceiver for multimode fiber, 850 nm wavelength, supports up to 550 m
    This link provides compatibility information:
    https://supportforums.cisco.com/document/140221/interconnect-cisco-sb-switch-and-catalyst-switch-sfp
    To interconnect a Small Business switch with Cisco Catalyst switch, you need to use Cisco Small Business SFP on the Small Business switches, and Cisco traditional SFP on Catalyst switches. And the SFP on both sides should follow the same IEEE standard. The mapping table is shown below.
    Cisco Small Business SFP
    Cisco traditional SFP
    GE Transceiver
    MGBSX1
    GLC-SX-MM
    SFP-GE-S
    MGBLX1
    MGBLH1
    GLC-LH-SM
    MGBBX1
    GLC-BX-D
    MGBT1
    GLC-T
    SFP-GE-T
    FE Transceiver
    MFEFX1
    GLC-FE-100FX
    GLC-GE-100FX
    MFELX1
    GLC-FE-100LX
    MFEBX1
    GLC-FE-100BX-D
    Thanks.
    Yiu Kay Lee
    Concentrix at Cisco
    .:|:.:|:. CISCO | Yiu Kay Lee | SMB Pre-Sales | [email protected] | Phone +1 (855) 354-7776

  • SG500X-48-K9-G5 and SG200-18 compatible SFP

    Hello,
    I am interesting if GLC-SX-MM sfp modules are compatible with following switches: SG500X-48-K9-G5 and SG200-18.
    Do you have any information about it ?

    Hi,
    It doesn't appear that the GLC-SX-MM is compatible with the SG500. I quoted the manual below so you can see the compatible SFPs for the two switches.
    Best,
    David
    Please rate helpful posts.
    From the SG500 manual:
    The following FE SFP (100Mbps) transceivers are supported:•          MFEBX1: 100BASE-BX-20U SFP transceiver for single-mode fiber, 1310 nm wavelength, supports up to 20 km.•          MFEFX1: 100BASE-FX SFP transceiver, for multimode fiber, 1310 nm wavelength, supports up to 2 km.•          MFELX1: 100BASE-LX SFP transceiver, for single-mode fiber, 1310 nm wavelength, supports up to 10 km.The following GE SFP (1000Mbps) transceivers are supported:•          MGBBX1: 1000BASE-BX-20U SFP transceiver, for single-mode fiber, 1310 nm wavelength, supports up to 40 km.Cisco 500 Series Stackable Managed Switch Administration Guide          93Managing Device Diagnostics          8•          MGBLH1: 1000BASE-LH SFP transceiver, for single-mode fiber, 1310 nm wavelength, supports up to 40 km.•          MGBLX1: 1000BASE-LX SFP transceiver, for single-mode fiber, 1310 nm wavelength, supports up to 10 km.•          MGBSX1:1000BASE-SX SFP transceiver, for multimode fiber, 850 nm wavelength, supports up to 550 m.•          MGBT1: 1000BASE-T SFP transceiver for category 5 copper wire, supports up to 100 m.
    From the SG300 manual:
    MSA-compatible SFPsThe following FE SFP (100Mbps) transceivers are supported:•          MFEBX1: 100BASE-BX-20U SFP transceiver for single-mode fiber, 1310 nm wavelength, supports up to 20 km.•          MFEFX1: 100BASE-FX SFP transceiver, for multimode fiber, 1310 nm wavelength, supports up to 2 km.•          MFELX1: 100BASE-LX SFP transceiver, for single-mode fiber, 1310 nm wavelength, supports up to 10 km.The following GE SFP (1000Mbps) transceivers are supported:•          MGBBX1: 1000BASE-BX-20U SFP transceiver, for single-mode fiber, 1310 nm wavelength, supports up to 40 km.•          MGBLH1: 1000BASE-LH SFP transceiver, for single-mode fiber, 1310 nm wavelength, supports up to 40 km.Cisco Small Business 300 1.1 Series Managed Switch Administration Guide          67Managing Device Diagnostics          7•          MGBLX1: 1000BASE-LX SFP transceiver, for single-mode fiber, 1310 nm wavelength, supports up to 10 km.•          MGBSX1:1000BASE-SX SFP transceiver, for multimode fiber, 850 nm wavelength, supports up to 550 m.•          MGBT1: 1000BASE-T SFP transceiver for category 5 copper wire, supports up to 100 m.

  • SFP change on Cisco 3750-X 24S

    Hello,
    I have a Cisco 3750-X 24S equipped with GLC-GE-100FX optical module to provide 100Mbps connectivity to workstation. I have to migrate the workstation NIC to 1 Gbps and, after that, I have to replace the 100base-FX SFP with the 1 GB SFP.
    Wich initial configuration on switch port allowm me to replace the SFP without any reconfiguration on the switch port?
    Thanks
    Gabriele

    Paolo is correct in that you do not need to change the configuration for the switch to recognize the SFP.
    However some IOS versions and hardware platforms do require you to manually configure the interface speed (even though a fiber SFP only operations at a fixed speed). Check the current port configuration. If it has "speed 100", be sure to change it to "speed 1000".
    Hope this helps.

  • The Adobe Forms was created with Disable Fields!

    Hi All,
    I am new in Adode Interactive Forms ABAP.  I am trying to implement a simple scenario using Web Services published by RFC on ABAP side and simple form with one field  MATNR to bring a Description MARKT, and button to call the Web Services.  I configured ADS on Server, installed  Adobe LifeCycle 8 and SAP GUI 7.1.  I created the  Adobe Form and it was actived.
    My issue is,  when a run the program  to generate a PDF, using the FMu2019s 'FP_JOB_OPEN'
    , 'FP_FUNCTION_MODULE_NAME', CALL FUNCTION i_funcname, the Adobe Forms was created with disables fields. I canu2019t fill it and canu2019t press the button to call WS on ECC.
    Could you help me?
    Thank you!
    Fábio Ferri
    SAP Consultant Netweaver

    Hi fabio,
    When you say the example ran successfully is it without any error messages..?
    Did you check in spool "SP01" if there something sitting out there.
    To my understanding PDF rendring is dependent in 2 aspects.
    1) the output device type you select (this should be a PDF enabled printer)
    2) Programatically if you say it should go to a printer or spool.
    Just try with FP_TEST_00 either in sfp or SE38 and try both print preview and print.
    in print priview it should display the PDF on the screen.
    In print it should display as success message and in spool it should have the corresponding PDF. if both are working fine then the ADS and output device config are correct and it all depends on how do you handle the PDF output.
    Just try the above approach and post the results,
    Cheers,

Maybe you are looking for

  • Change in Material Description in Sales Order

    HI, We have a scenario where there's a change in our existing material Description and there's an existing SO of the said material. When we changed the description in MM03, it doesn't reflected/changed in VA03. The material description there, remains

  • Help with Epson and HP All-In-One Drivers

    I've been looking through the forums for a day and not really finding what I'm looking for, so I decided to post... Running an AE-N for a Macbook, a Powermac, and a Powerbook. I've got two printers...an Epson R200 photo printer and an HP PSC 1410 All

  • Question with installing operating system to my new hard drive

    I just ordered a new hard drive for my macbook.  I've had no problems finding how to take out the old one and install the new one into my computer, but I can't seem to find information on how to install osx onto the my computer again.  Is it as simpl

  • Workaround for compressor HDV to DVD field issue?

    I need a work around for the field issue apparent when down-converting HDV to DVD. The Bonsai method <http://www3.telus.net/bonsai/Welcome.html> will not work, as there is too much motion and a side effect of the "fastest" conversion is that it gives

  • Media Encoder 5.5 - h.264 output sync off by 1 frame