Status Led AP 1250 Ligthweight

Hi:
Somebody could you help me, a few day l have 3 AP Ligthweight 1250, today l was checking my infrastructure and l saw that these 3 AP can´t join to the controller, l reset the AP  to the, and its can not  join, l checked physicly the AP, and the Ethernet Led is in Amber permanent and the Radio Led is in Green permanet , i am searching the status led to find the fix but l have not found these convination led. and l can not access to the consolo port.
Thanks in advance for your help.
Regards

http://tiny.cc/uygtkw
Rating useful replies is more useful than saying "Thank you"

Similar Messages

  • Cisco 1131AG LWAP status led yellow and other leds blinking green

    I have a problem with three AIR-LAP1131AG-E-K9  that joined the controller and the status led turns to yellow after joining the controller while other LEDs are blinking green.
    The APs has no coverage at all although the WCS shows that there is coverage and the 4400WLC shows that the AP interfaces are UP. (The ethernet interface and tha 802.11b,g radio interface is up).
    The SSID broadcast is enabled.
    On the switch the interface is up and there is traffic going in and out of the LAP.
    I tired power reset and factory reset for the APs but the problem remains the same.
    Any ideas for what might be the problem ?!!
    Regards

    Yes the clients are not able to see the SSID broadcasted by the AP.
    But these APs were functioning normally before without any changes to the WLC config.
    I had the same problem with other APs but they went back to normal state after a hardware reset to the APs.

  • WiSM Status LED 1 & Status LED 2 showing off. Is it normal?

    Hi,
    WiSM WLAN Service Module WS-SVC-WISM-1-K9 in 6509e running VSS IOs s72033-ipservicesk9_wan-mz.122-33.SXI2a.bin having trouble to get the IP from service-vlan DHCP also status LED 1 & Status LED 2 showing off.
    The pertinent config is as follows.
    vlan 300
    name WiSM_Service_Vlan
    interface Vlan300
    description *** WiSM Service-Vlan
    ip address 192.168.200.1 255.255.255.0
    ip dhcp excluded-address 192.168.200.1
    ip dhcp pool WiSM_Service-Vlan_300
       network 192.168.200.0 255.255.255.0
       default-router 192.168.200.1
    wism service-vlan 300
    vlan 183
    name WiSM_Management
    interface Vlan183
    description *** WiSM Management Vlan ***
    ip address 10.39.139.254 255.255.255.0
    wism switch 1 module 4 controller 1 allowed-vlan 125,126,183,300
    wism switch 1 module 4 controller 2 allowed-vlan 125,126,183,300
    wism switch 2 module 4 controller 1 allowed-vlan 125,126,183,300
    wism switch 2 module 4 controller 2 allowed-vlan 125,126,183,300
    wism switch 1 module 4 controller 1 native-vlan 183
    wism switch 1 module 4 controller 2 native-vlan 183
    wism switch 2 module 4 controller 1 native-vlan 183
    wism switch 2 module 4 controller 2 native-vlan 183
    HO2NET0001#sh wism status
    Service Vlan : 300, Service IP Subnet : 192.168.200.1/255.255.255.0
          WLAN
    Slot  Controller  Service IP       Management IP    SW Version  Status
    ----+-----------+----------------+----------------+-----------+---------------
    20    1           0.0.0.0          0.0.0.0                      Service Port Up
    20    2           0.0.0.0          0.0.0.0                      Service Port Up
    HO2NET0001#sh module
    Mod Ports Card Type                              Model              Serial No.
      1    8  CEF720 8 port 10GE with DFC            WS-X6708-10GE      SAL13442Q5N
      2    8  CEF720 8 port 10GE with DFC            WS-X6708-10GE      SAL13442GAL
      3   48  CEF720 48 port 10/100/1000mb Ethernet  WS-X6748-GE-TX     SAL13410N8P
      4   10  WiSM WLAN Service Module               WS-SVC-WISM-1-K9   SAD133101UY
      5    5  Supervisor Engine 720 10GE (Active)    VS-S720-10G        SAL13442JE4
    Mod MAC addresses                       Hw    Fw           Sw           Status
      1  0025.84f1.55b8 to 0025.84f1.55bf   2.1   12.2(18r)S1  12.2(33)SXI2 Ok
      2  0025.84f1.4e58 to 0025.84f1.4e5f   2.1   12.2(18r)S1  12.2(33)SXI2 Ok
      3  0027.0da7.c240 to 0027.0da7.c26f   3.2   12.2(18r)S1  12.2(33)SXI2 Ok
      4  0023.5e25.7168 to 0023.5e25.7177   2.3   12.2(14r)S5  12.2(33)SXI2 Ok
      5  001f.9e2a.2608 to 001f.9e2a.260f   3.1   8.5(3)       12.2(33)SXI2 Ok
    Mod  Sub-Module                  Model              Serial       Hw     Status
      1  Distributed Forwarding Card WS-F6700-DFC3C     SAL13442EG9  1.4    Ok
      2  Distributed Forwarding Card WS-F6700-DFC3C     SAL13442H9T  1.4    Ok
      3  Centralized Forwarding Card WS-F6700-CFC       SAL13442HU9  4.1    Ok
      4  Centralized Forwarding Card WS-SVC-WISM-1-K9-D SAD133200D6  2.1    Ok
      5  Policy Feature Card 3       VS-F6K-PFC3C       SAL13442E5S  1.1    Ok
      5  MSFC3 Daughterboard         VS-F6K-MSFC3       SAL13421AJZ  2.0    Ok
    Mod  Online Diag Status
      1  Pass
      2  Pass
      3  Pass
      4  Pass
      5  Pass
    HO2NET0001#sh vlan
    300  WiSM_Service_Vlan                active    Gi1/4/9, Gi1/4/10
    The service IP is supposed to have been populated with an address from the dhcp pool. I am also unable to connect to access it by console as well as doing a session switch 1 slot 4 processor 1. I get the following upon attempting to do so:
    Through Console.
    It is giving following & then got stuck.
    Bootloader 3.2.202.0 (Nov 13 2007 - 19:35:12)
    Motorola PowerPC ProcessorID=00000000 Rev. PVR=80200020
            CPU: 999 MHz
            CCB: 333 MHz
            DDR: 166 MHz
            LBC: 41 MHz
    L1 D-cache 32KB, L1 I-cache 32KB enabled.
    I2C:   ready
    DTT:   1 is 33 C
    DRAM:  DDR module detected, total size:512MB.
    512 MB
    8540 in PCI Host Mode.
    8540 not PCI Arbiter.
    Memory Test PASS
    FLASH:
      Flash Bank 0: portsize = 2, size = 8 MB in 142 Sectors
    8 MB
    L2 cache enabled: 256KB
    Card Id: 1537
    Card Revision Id: 1
    Card CPU Id: 1287
    Number of MAC Addresses: 32
    Number of Slots Supported: 4
    Serial Number: FAM133200D6
    Manufacturers ID: 30464
    Board Maintenance Level: 00
    In:    serial
    Out:   serial
    Err:   serial
                          .o88b. d888888b .d8888.  .o88b.  .d88b.
                         d8P  Y8   `88'   88'  YP d8P  Y8 .8P  Y8.
                         8P         88    `8bo.   8P      88    88
                         8b         88      `Y8b. 8b      88    88
                         Y8b  d8   .88.   db   8D Y8b  d8 `8b  d8'
                          `Y88P' Y888888P `8888Y'  `Y88P'  `Y88P'
                        Model SVC-WiSM   S/N: FAM133200D6
    Net:   TSEC ETHERNET
    IDE:   Bus 0: OK
      Device 0: Model: STI Flash 8.0.0 Firm: 01/17/07 Ser#: STI1MMJ109198093647
                Type: Removable Hard Disk
                Capacity: 488.7 MB = 0.4 GB (1000944 x 512)
      Device 1: not available
    Booting Primary Image...
    Press <ESC> now for additional boot options...
    Detecting Hardware . . .
    Cryptographic library self-test....passed!
    XML config selected
    Validating XML configuration
    Cisco is a trademark of Cisco Systems, Inc.
    Software Copyright Cisco Systems, Inc. All rights reserved.
    Cisco AireOS Version 5.2.178.0
    Initializing OS Services: ok
    Initializing Serial Services: ok
    Initializing Internal Interfaces: ok
    Initializing Network Services: ok
    Initializing Licensing Services: ok
    Starting ARP Services: ok
    Starting Trap Manager: ok
    Starting Network Interface Management Services: ok
    Starting System Services: ok
    Starting FIPS Features: ok : Not enabled
    Starting Fast Path Hardware Acceleration: ok
    Starting Switching Services: ok
    Starting QoS Services: ok
    Starting Policy Manager: ok
    Starting Data Transport Link Layer: ok
    Starting Access Control List Services: ok
    Starting System Interfaces: ok
    Starting Client Troubleshooting Service: ok
    Starting Management Frame Protection: ok
    Starting LWAPP: ok
    Starting CAPWAP: ok
    Starting Certificate Database: ok
    Starting VPN Services: ok
    Starting Security Services: ok
    Starting Policy Manager: ok
    Starting Authentication Engine: ok
    Starting Mobility Management: ok
    Starting LOCP: ok
    Starting Virtual AP Services: ok
    Starting AireWave Director: ok
    Starting Network Time Services: ok
    Starting Cisco Discovery Protocol: ok
    Starting Broadcast Services: ok
    Starting Logging Services: ok
    Starting DHCP Server: ok
    Starting IDS Signature Manager: ok
    Starting RFID Tag Tracking: ok
    Starting WLAN Control Protocol (WCP): ok
    Starting Mesh Services:  ok
    Starting TSM: ok
    Starting CIDS Services: ok
    Starting Ethernet-over-IP: ok
    Starting DTLS server:  enabled in CAPWAP
    Starting FMC HS: ok
    Starting WIPS: ok
    Starting SSHPM LSC PROV LIST: ok
    Starting Management Services:
       Web Server: ok
       CLI: ok
       Secure Web: Web Authentication Certificate not found (error). If you cannot access management interface via HTTPS please reconfigure Virtual Interface.
    (Cisco Controller)
    Welcome to the Cisco Wizard Configuration Tool
    Use the '-' character to backup
    Would you like to terminate autoinstall? [yes]:
    AUTO-INSTALL: starting now...
    Through Session
    HO2NET0001##session switch 1 slot 4 proc 1
    The default escape character is Ctrl-^, then x. You can also type 'exit' at the remote prompt to end the session Trying 0.0.0.0 ...
    Any assistance or ideas offered will be greatly appreciated.
    Thanks,

    Hi Tabish,
    How many times do you have to open this same topic?
    In my opinion, this is your THIRD thread for the same topic.

  • FP-1600 Status LED blinks 17 times.

    My FieldPoint bank has 9 modules. I previously had a problem with the FP-TB-10 power and ready lights blinking, but that was because one of my dual-channel modules was not seated correctly. Now the status LED is blinking 17 times. The manual says to contact NI about this. The FieldPoint Explorer seems to find all of the modules correctly, though. Anyone know what's up?

    Aaron,
    I checked the firmware and the FieldPoint Explorer version, and I'm using 3.20 and 3.0, respectively. When I power cycle the FP-1600, the 17 blinks of the status LED go away. Communication works, and all of the devices are found. However, communication does drop out from time to time, and eventually the status LED begins blinking 17 times again.
    A possibly related issue is that the FP-AI-V10 dual-channel module that I have plugged into slot 2 of the FP-TB-10 base causes the FP-TB-10 to flash its power and ready LEDs. Re-seating the FP-AI-V10 seems to fix this, although the module is definitely already clicked into place when I see this problem. Upon reseating (or just pressing on it without removing the module), the FieldPoint Explo
    rer program finds this module.
    I'm tempted to think that this issue with the FP-TB-10 and FP-AI-V10 are unrelated to the FP-1600's status LED blinking 17 times because even with the FP-TB-10 removed from the bank, I still get the flashing LED.
    Any ideas? Also, what is a GPF type error?
    Thanks,
    Jake

  • Status led always on

    I have a macbook wich has been wet with soda, i dried the macbook and cleaned it up. Everything seems to work fine except for the status led thats always on. I already have reseted the smc following the instructions provided by apple but the led remains on.
    Thanks in advance for your help
    PD. I know my english ***** xD.

    Stu--
    Take your unit in and have it examined! Until you do...turn it off, unplug it, take out the battery, and see if anything else drains out. Don't use it until it's been looked over.
    Doc

  • Lenovo 3000 N500 23G Battery Status LED problem.

    I am having problems with the Battery Status LED on my new laptop.  The LED turns blue at around 22-30% charge and the Hardware manual indicates it should be 95%, also the LED remains lit when fully charged on battery power when it should be off. The biggest problem is that I have no idea on when the battery is charged and I should not need to boot into windows to check this.
    I have already returned an identical model to the retailer for the same reason, they did confirm that the unit was faulty and send me another which seems to have the same suspected fault.
    Has any one else have the same problem as me, I am not too sure if I should return the 2nd unit for a refund and look elsewhere?
    I did contact Lenovo support before and was advised to get it repaired under warranty, I did not need to do this as the unit is less than 30 days old and I wouldbe entitled to a refund or replacement.
    Below is an excerpt from the manual I downloaded from this website.
    Thanks, Mark.
    Blue: The battery is charged to 95% or more of its capacity.
    Blinking blue: The battery is being trickle-charged
    Orange: The battery is being normally charged
    Off: The computer is operating on battery power, and the battery has enough power
    Blinking orange: The computer is operating on battery power, and the battery is charged to no more than 8% of capacity.)

    The battery is going to fail on this unit; actually it is a defect in the circuit built into the battery the detects charge level.  It has been happening quite frequently with IBM/Lenovo batteries these days.  If you have warranty left, get the unit in for repair or you will be out of luck like the rest of us who bought these units with failure prone batteries and a poor excuse for product quality.  If you care to help your fellow Lenovo owners, call, email, write, picket, jump up and down, do what ever you have to do to voice your concern and complaint to as high a person as you can at IBM and Lenovo.  We have to keep the heat on at a corporate level at both IBM and Lenovo, to remind them that there is a price to pay for the fact that they do not care about their customers.   

  • Sup V with 4507R status led in Red

    Hi,
    I carried out an upgrade in 4507R with 2 sup V, I loaded in both card 12.2(53)SG10 and I confirmed the redundancy is working
    I don't understand why both status led (for Sup V) are in red.
    the loggs do not show error ,  any idea how can I identify the reason of red color in status led?
    regards
    Mod  Redundancy role     Operating mode      Redundancy status
    ----+-------------------+-------------------+----------------------------------
    1   Standby Supervisor  SSO                 Standby hot
    2   Active Supervisor   SSO                 Active
    redundancy
    mode sso
    main-cpu
      auto-sync standard

    Hello,
    The status LED can actually lend useful information regarding the potential culprits to your issue. You can check out the STATUS LED Error Indications in the 1601 User Manual.
    In this case, it looks like you should contact National Instruments directly since it seems as though the module did not power on correctly. You may have to return your unit for replacement or repair.
    Cheers,
    Emilie K. | Applications Engineer | National Instruments

  • Sun Fire X2100  Blinking Status LED...

    We have 3 new Sun Fire X2100 servers at my current job. Just recently the status LED (orange) started blinking. The logs show fine and running a prtdiag shows everything up and running fine. Is there a way to turn off the blinking LED? I have gone over every piece of information I can find and have found nothing about how to turn this off once it has started blinking.

    This may be one of two issues:
    - There's a know ILOM/nge driver bug in eariler releases of S10 x86 (pre 6/06).
    - There's a know issue with an older firmware rev of the BIOS/LOM where the net management port hangs/drops out and triggers the blinking fault LED. Do you know what BIOS revision you are at?
    Most times a mobo swap is NOT the fix. You may be making the problem worse because we have mobos in the supply chain with older firmware revisions.
    On the X2100's I usually have my customers try:
    - Moving the RAM in different slots
    - Updating the BIOS/LOM firmware
    - Running the PC-Check diags
    ... before I send a field tech out to do major surgery.

  • SUN Fire V65 - System Status LED - non-critical condition

    Hi guys
    We have a Checkpoint Cluster which is made up of 2 Sun Fire V65 servers.
    The front panel of the servers are showing the System Status LED lights as Blinking Amber , which sun documenation has listed as
    "Blinking amber: Indicates the system is in a non-critical condition" ref: http://dlc.sun.com/pdf/817-2024-12/817-2024-12.pdf
    We have resetead the hardware, cleared ,logs, even change HW etc. The light goes away for some time and then returns.
    Can anyone advise on what to do?
    Sun has the following listed in their Troubleshooting pdf i ref before
    "Non-Critical Condition
    A non-critical condition is indicated with a blinking amber status LED and signifies
    that at least one of the following conditions is present:
    ¡ Temperature, voltage, or fan non-critical threshold crossing.
    ¡ Chassis intrusion.
    ¡ Satellite controller sends a non-critical state, via the Set Fault Indication
    command, to the BMC.
    ¡ A Set Fault Indication command from the system BIOS. The BIOS may use the Set
    Fault Indication command to indicate additional, non-critical status such as
    system memory or CPU configuration changes"
    Is there any Unix / Linux / SPLAT logs I can look at or debugging we can look at.
    Thanks in advance

    Your initial description mentions that you have swapped various pieces of hardware around. I presume that means you used current parts instead of new-never-used components. Are both of the clustered systems showing the same symptoms?
    I can only think of a couple of additional things to try.
    Firstly, those are old boxes. V65's went EOL in January 2005, so yours are at least that old if not older. They are x86 architecture. Have you replaced the CR2032 CMOS battery that's on the systemboard? Have you additionally checked for voltage fluctuations in the data center? A marginal power supply can "mostly work" but it can be effected by an AC mains issue.
    If that doesn't change anything, then you may need to contact Checkpoint. They may be able to point you toward some sort of heartbeat function that is tripping a fault level when it flip-flops between the two systems.
    That's a software investigation and would be outside the scope of this forum.

  • Ultra 45  power/status led no display green light

    Hi, i have a problem with my ultra 45. Wonder if anyone come across this. My system when booted will have the green led on but after awhile the led turns off when booting up. The system is able to run up and perform properly except the status led is off.
    First i assume is due to the keyboard and mouse where i didn't connect properly but it does'nt seems to be the problem. I have search through the net and didn't found any useful solution. Hopefully i can get one here. Thanks
    Edited by: kemwah on Sep 16, 2007 8:31 AM

    Anyone got answer for this problem??

  • CompactRIO unusual error status LED flashing continuously

    Hi,
    I have a cRIO 9014 controller with an error i can't solve.
    After re-installing LV 8.5 on my laptop MAX could see the controller but with the VISA and NI-RIO error. I wanted to obtain the IP address from the DHCP server (before i used the static IP address without any problems), rebooted the controller and the status LED started flashing continuously every 1 second. (unrecoverable error or corrupted flash memory card)
    I rebooted the controller several times with IP reset but LED is still flashing. Also in MAX i can't see the controller anymore so reformatting controller  is not possible.
    Firewall is off, crossover cable is connected, IP of host is ok but no cRIO in MAX
    Found a similar problem on the forum http://forums.ni.com/ni/board/message?board.id=170&message.id=238333&query.id=24781#M238333 but it didn't solve my problem unfortunately.
    Thanks for your help!
    Greetings from the Netherlands

    Hello TrabW,
    Thank you for your post on our webforum.
    Can you try to start up the controller in safe mode? Is it possible to ping the controller? Please try the default IP address and the one you entered (in case the controller didn't reset the IP). Please let me know the results,
    Best regards,
    Martijn S
    Applications Engineer
    NI Netherlands

  • CFP 2110 - Status led flashing continously

    I'm running into problem with a cFP 2110.
    During the debugging of my RT application on the cFP, I get an error message "Host IP address not in the access list". At this time, I was unable to download any application to the cFP. the VI server IP access list was configured with *. So all the IP address can access to the cFP.
    I found a procedure on the ni web site to reset the system.
    -Set to safe mode
    -ftp the cFP and delete all the file
    -Remove the safe mode.
    It means that there is no more OS or LabVIEW RT on the system.
    Now, When I restart the cFP, the Status led is flashing continously (1 flash / 1.5s) and I don't have access anymore to the cFP in MAX.. Can some one help me on this case ? .
    Thanks
    Attachments:
    Ni_recommendations.pdf ‏126 KB

    Hi Poussin,
    I would recommend flipping the Reset IP dip switch (dip switch 7).  This
    should get the controller to show up in Measurement and Automation
    Explorer(MAX) as 0.0.0.0.  If you can't see the controller, you may want
    to try turning off your firewall.  Often computer firewalls will prevent
    customers from seeing unconfigured controllers in MAX. 
    Once you find your controller, you can flip the reset IP dip switch back to the
    off position and reset the IP address.  For more information on this,
    click on your FieldPoint controller in MAX that will be displayed as
    0.0.0.0.  In the MAX help that appears on the right, click on the link
    titled, "Configure Network Settings."  If you need assistance
    choosing an IP address, please look at this KnowledgeBase. 
    Once you have assigned an IP address to the controller, the status light should
    stop blinking once.   You will then need to install software. 
    Here is a general
    document that describes how to assign an IP address and install software.
    Please let me know if you have any other questions.
    Regards,
    Ching P.
    DAQ and Academic Hardware R&D
    National Instruments

  • FP 1601 status led shows red continuously

    I am trying to use FP 1601 which was already configured long before. But now the status LED is continuously red .Power LEd is green and all other LEds are off. Am giving 24V power and checked that it is given to V and C properly .Ethernet connection is also proper. i tried to reset , but could not. i cant use it in anymore. can anyone help in troubleshooting

    Hello,
    The status LED can actually lend useful information regarding the potential culprits to your issue. You can check out the STATUS LED Error Indications in the 1601 User Manual.
    In this case, it looks like you should contact National Instruments directly since it seems as though the module did not power on correctly. You may have to return your unit for replacement or repair.
    Cheers,
    Emilie K. | Applications Engineer | National Instruments

  • Live! Cam - Status LED Control

    hi,
    I hold an integrated Live! Cam. I would like to know at which level its status led is controlled. Software, firmware or circuits?
    May it be possible for a hacker to turn the led on/off remotly ?
    thx

    JPhotography wrote:
    Since FaceTime quitted a conversation on its own, the litte green status-LED of the camera is shining all the time, even in stand by and to restarts.
    If I open FaceTime now, it can not find a camera.
    Does anyone know this problem?
    What can I do against this?
    It is really annoying. Since Mountain Lion some things really go wrong..
    Sounds like a trip to your local AS or AASP if the solutions in KB Article http://support.apple.com/kb/HT2090 How to Troubleshoot iSight does not work.

  • CFP status led - stays lit solid red!

    Hi,
    I have a problem with a cFP-2120 RT controller where the red LED status light stays lit.  On the instruction manual it says that the unit was not powered up correctly and to contact NI.  The controller used to work fine until we had a short on the mains side of the power supply The AI, AO and thermocouple modules did not power up but the DI and DO modules seemed to be getting power.  Is there anything we can do or just send it back for repairs.  When I replaced the controller with another one, the system worked fine and the status LED turned off after a few seconds.
    rgds
    Inzaghi_2

    Sounds like you've proven that the controller is bad.  Next step is an RMA from NI.  Make sure NI tells you what failed in the controller and see if they will comment on what might have caused it.   The idea being to see if you can do anything to prevent this failure in the future.

Maybe you are looking for