Steps to create field exit

Hi Gusy,
I need some enhancement requied in MIRO, could you please suggest, steps to create the filed exits?
Thanks,
Gourisankar.

Hi,
There are two ways either go to CMOD and type PRFB in the transaction area( where you enter the trwansaction code) it would open a new screen go to menu path > field exit> create and then choose the data element you want to create the field exit for and a function module would be created like field_exit_fieldname.
Then write your logic and activate and then click on assign button and assing that to the screen where you wnat it to fire.
Search SCN you would get a lot of threads for your requirement like below too:
Field Exit
Regards,
Himanshu

Similar Messages

  • How  to Creating Field EXIT

    Hi,
      Please tell me the step by step procedure for creating Filed Exit

    Hi Mohan,
    This will be too useful for u...
    Step by step procedure for creating Field Exits
    There are eight steps to creating a field exit:
                Step 1: Determine Data Element
                Step 2: Go To Field Exit Transaction
                Step 3: Create Field Exit
                Step 4: Create Function Module
                Step 5: Code Function Module
                Step 6: Activate Function Module
                Step 7: Assign Program/Screen
                Step 8: Activate Field Exit
    Step 1: Determine Data Element
    - Before you can begin adding the functionality for a field exit, you must know the corresponding data element.
    - An easy way to determine the data element associated to a particular screen field is to:
    Go the appropriate screen.
    Position the cursor in the appropriate field.
    Press ‘F1’ for field-level help.
    Click on the ‘Technical info’ pushbutton (or press ‘F9’) on the help dialog box.
    On this Technical Information dialog box, the data element will be specified if the field is 'painted' from the ABAP/4 Dictionary.
    Step 2: Go To Field Exit Transaction
    - The transaction to create field exits is CMOD.
    - You can use the menu path Tools -> ABAP/4 Workbench -> Utilities -> Enhancements -> Project management.
    - From the initial screen of transaction CMOD, choose the Text enhancements -> Field exits menu path.
    - After choosing this menu path, you will be taken to the field exits screen. From here, you can create a field exit.
    NOTE : Even though you use transaction CMOD to maintain field exits, you do not need to create a project to activate field exits.
    Step 3: Create Field Exit
    - From the field exit screen of transaction CMOD, choose the Field exit -> Create menu path.
    - After choosing this menu path, a dialog box will prompt you for the appropriate data element .
    - Enter the data element name and click the ‘Continue’ pushbutton.
    - Now, you will be able to create the function module associated to the data element’s field exit.
    Step 4: Create Function Module
    - You will automatically be taken to the Function Library (SE37) after entering a data element name and clicking the ‘Continue’ pushbutton.
    - In the ‘Function module’ field, a function module name will be defaulted by the system based on the data element specified. This name will have the following convention:
    FIELD_EXIT_<data element>
    - You can add an identifier (an underscore followed by a single character ).
    - The first function module for a data element’s field exit must be created without an identifier.
    - To create the function module, click on the ‘Create’ pushbutton, choose menu path Function module -> Create, or press ‘F5’.
    - After choosing to create the function module, you will get the warning: "Function module name is reserved for SAP". This message is just a warning so a developer does not accidentally create a function module in the field exit name range. By pressing ‘Enter’, you will be able to go ahead and create the function module.
    - Before coding the function module, you will have to specify the function modules attributes -- function group, application, and short text.
    Step 5: Code Function Module
    - From the function module’s attributes screen, click on the ‘Source code’ pushbutton or choose the Goto -> Function module menu path to the code of the function module.
    - Here you will add your desired functionality for the field exit.
    - Remember that field exit’s function module will have two parameters -- one importing parameter called "INPUT" and one exporting parameter called "OUTPUT". These parameters will be set up automatically by the system.
    - You must remember to assign a value to the OUTPUT field. Even if the value does not change, it must be moved from the INPUT field to the OUTPUT field.
    Step 6: Activate Function Module
    - After coding the function module, you must remember to activate it.
    - Use the Function module -> Activate menu path to activate the function module.
    - At this point, you can return to the field exit transaction.
    - You should be able to 'green arrow' back to this transaction.
    - When you return to the field exit transaction, you will see an entry for the newly created field exit.
    - At this point, the field exit is global. That is, it applies to all screens that use a particular data element. On any screen that uses the data element, the corresponding field exit function module will be triggered, once it is active.
    - Also, the field exit will not be triggered yet because it is inactive.
    Step 7: Assign Program/Screen
    - This step is only needed if you want to make a field exit local.
    - To make a field exit local, select the field exit and click on the ‘Assign prog./screen’ pushbutton.
    - In the dialog box , indicate the appropriate program name and screen number.
    This information indicates that the field exit is local to the specified screen in the specified program.
    - In the dialog box, you determine which function module gets executed for the field exit by specifying the identifier in the ‘Fld. Exit’ field.
    - If this field is left blank, the function module triggered will be 'FIELD_EXIT_<data element>'.
    - If a single-character identifier is entered into the field, the function module triggered will be 'FIELD_EXIT_<data element>_<identifier>'.
    Step 8: Activate Field Exit
    - The field exit must be active for it to be triggered by the system.
    - Activate the field exit by choosing the Field exit -> Activate menu path.
    - After assigning the field exit to a change request, its status will change to ‘Active’ and it will be triggered automatically on the appropriate screen(s).
    NOTE : In order to activate the field exit the profile parameter abap/fieldexit = YES must be set on all application servers
    Set the above config in Tcode RZ11

  • Steps to create user exit Macro

    Hello,
    Can any share the step by Step procedure to create user exit macro for APO DP planning book.
    Regards,
    Manish

    Hi Manish,
    Please see OSS note 418801.
    Regards,
    Alexander

  • General Steps in Creating User Exits

    Can someone give me outline of the Steps involved in Userexits...

    For information on Exits, check these links
    http://www.sap-img.com/abap/a-short-tutorial-on-user-exits.htm
    http://www.sapgenie.com/abap/code/abap26.htm
    http://www.sap-img.com/abap/what-is-user-exits.htm
    http://wiki.ittoolbox.com/index.php/HOWTO:Implement_a_screen_exit_to_a_standard_SAP_transaction
    http://www.easymarketplace.de/userexit.php
    http://www.sap-img.com/abap/a-short-tutorial-on-user-exits.htm
    http://www.sappoint.com/abap/userexit.pdfUser-Exit
    http://www.planetsap.com/userexit_main_page.htm
    Raja T
    Message was edited by:
            Raja Thangamani

  • What is Field Exit--Step By Step procedure..

    Hi,
    What is Field Exit.
    And How to validate a field on any screen using field exit.
    what is the Procedure.
    Please give me Step by Step Procedure.
    Points will be given for straight answers..
    Regards,
    Kiran

    Please find below the step by step procedure for field exit :-
    There are eight steps to creating a field exit:
    Step 1: Determine Data Element
    Step 2: Go To Field Exit Transaction
    Step 3: Create Field Exit
    Step 4: Create Function Module
    Step 5: Code Function Module
    Step 6: Activate Function Module
    Step 7: Assign Program/Screen
    Step 8: Activate Field Exit
    Step 1: Determine Data Element
    Before you can begin adding the functionality for a field exit, you must know the corresponding data element.
    An easy way to determine the data element associated to a particular screen field is to:
    Go the appropriate screen.
    Position the cursor in the appropriate field.
    Press ‘F1’ for field-level help.
    Click on the ‘Technical info’ pushbutton (or press ‘F9’) on the help dialog box.
    On this Technical Information dialog box, the data element will be specified if the field is 'painted' from the ABAP/4 Dictionary.
    Step 2: Go To Field Exit Transaction
    The transaction to create field exits is CMOD.
    You can use the menu path Tools -> ABAP/4 Workbench -> Utilities -> Enhancements -> Project management.
    From the initial screen of transaction CMOD, choose the Text enhancements -> Field exits menu path.
    After choosing this menu path, you will be taken to the field exits screen. From here, you can create a field exit.
    NOTE : Even though you use transaction CMOD to maintain field exits, you do not need to create a project to activate field exits.
    Step 3: Create Field Exit
    From the field exit screen of transaction CMOD, choose the Field exit -> Create menu path.
    After choosing this menu path, a dialog box will prompt you for the appropriate data element .
    Enter the data element name and click the ‘Continue’ pushbutton.
    Now, you will be able to create the function module associated to the data element’s field exit.
    Step 4: Create Function Module
    You will automatically be taken to the Function Library (SE37) after entering a data element name and clicking the ‘Continue’ pushbutton.
    In the ‘Function module’ field, a function module name will be defaulted by the system based on the data element specified. This name will have the following convention:
    FIELD_EXIT_<data element>
    You can add an identifier (an underscore followed by a single character ).
    The first function module for a data element’s field exit must be created without an identifier.
    To create the function module, click on the ‘Create’ pushbutton, choose menu path Function module -> Create, or press ‘F5’.
    After choosing to create the function module, you will get the warning: "Function module name is reserved for SAP". This message is just a warning so a developer does not accidentally create a function module in the field exit name range. By pressing ‘Enter’, you will be able to go ahead and create the function module.
    Before coding the function module, you will have to specify the function modules attributes -- function group, application, and short text.
    Step 5: Code Function Module
    From the function module’s attributes screen, click on the ‘Source code’ pushbutton or choose the Goto -> Function module menu path to the code of the function module.
    Here you will add your desired functionality for the field exit.
    Remember that field exit’s function module will have two parameters -- one importing parameter called "INPUT" and one exporting parameter called "OUTPUT". These parameters will be set up automatically by the system.
    You must remember to assign a value to the OUTPUT field. Even if the value does not change, it must be moved from the INPUT field to the OUTPUT field.
    Step 6: Activate Function Module
    After coding the function module, you must remember to activate it.
    Use the Function module -> Activate menu path to activate the function module.
    At this point, you can return to the field exit transaction.
    You should be able to 'green arrow' back to this transaction.
    When you return to the field exit transaction, you will see an entry for the newly created field exit.
    At this point, the field exit is global. That is, it applies to all screens that use a particular data element. On any screen that uses the data element, the corresponding field exit function module will be triggered, once it is active.
    Also, the field exit will not be triggered yet because it is inactive.
    Step 7: Assign Program/Screen
    This step is only needed if you want to make a field exit local.
    To make a field exit local, select the field exit and click on the ‘Assign prog./screen’ pushbutton.
    In the dialog box , indicate the appropriate program name and screen number.
    This information indicates that the field exit is local to the specified screen in the specified program.
    In the dialog box, you determine which function module gets executed for the field exit by specifying the identifier in the ‘Fld. Exit’ field.
    If this field is left blank, the function module triggered will be 'FIELD_EXIT_<data element>'.
    If a single-character identifier is entered into the field, the function module triggered will be 'FIELD_EXIT_<data element>_<identifier>'.
    Step 8: Activate Field Exit
    The field exit must be active for it to be triggered by the system.
    Activate the field exit by choosing the Field exit -> Activate menu path.
    After assigning the field exit to a change request, its status will change to ‘Active’ and it will be triggered automatically on the appropriate screen(s).
    NOTE : In order to activate the field exit the profile parameter abap/fieldexit = YES must be set on all application servers
    Regards
    Kiran

  • Field Exit for VA11 screen ?

    Hello Abapers,
                         I need ur help to find out the field exit available for VA11 screen.
    How to find the field exit wht is the procedure?
    Thks

    Hi Venkateswar,
    First you check this link once.,
    http://www.****************/Tutorials/ExitsBADIs/MK01/FieldExit.htm
    Field exits are frozen on the 4.6C maintenance level and are not further developed. This means that the existing functionality is kept with all restrictions (see also the last item below). Existing exits can be further used and are called at runtime as usual.
    Existing exits can be maintained using program RSMODPRF (run the program using transaction SE38). Activation of the field exits and assignment of the dynpros can also be carried out using program RSMODPRF. For this purpose, the program must be started without parameters (input fields remain blank).
    If required, new field exits can be created using program
    RSMODPRF (see the program documentation).
    Please find below the step by step procedure for field exit :-
    There are eight steps to creating a field exit:
    Step 1: Determine Data Element
    Step 2: Go To Field Exit Transaction
    Step 3: Create Field Exit
    Step 4: Create Function Module
    Step 5: Code Function Module
    Step 6: Activate Function Module
    Step 7: Assign Program/Screen
    Step 8: Activate Field Exit
    Step 1: Determine Data Element
    Before you can begin adding the functionality for a field exit, you must know the corresponding data element.
    An easy way to determine the data element associated to a particular screen field is to:
    Go the appropriate screen.
    Position the cursor in the appropriate field.
    Press ‘F1’ for field-level help.
    Click on the ‘Technical info’ pushbutton (or press ‘F9’) on the help dialog box.
    On this Technical Information dialog box, the data element will be specified if the field is 'painted' from the ABAP/4 Dictionary.
    Step 2: Go To Field Exit Transaction
    The transaction to create field exits is CMOD.
    You can use the menu path Tools -> ABAP/4 Workbench -> Utilities -> Enhancements -> Project management.
    From the initial screen of transaction CMOD, choose the Text enhancements -> Field exits menu path.
    After choosing this menu path, you will be taken to the field exits screen. From here, you can create a field exit.
    NOTE : Even though you use transaction CMOD to maintain field exits, you do not need to create a project to activate field exits.
    Step 3: Create Field Exit
    From the field exit screen of transaction CMOD, choose the Field exit -> Create menu path.
    After choosing this menu path, a dialog box will prompt you for the appropriate data element .
    Enter the data element name and click the ‘Continue’ pushbutton.
    Now, you will be able to create the function module associated to the data element’s field exit.
    Step 4: Create Function Module
    You will automatically be taken to the Function Library (SE37) after entering a data element name and clicking the ‘Continue’ pushbutton.
    In the ‘Function module’ field, a function module name will be defaulted by the system based on the data element specified. This name will have the following convention:
    FIELD_EXIT_<data element>
    You can add an identifier (an underscore followed by a single character ).
    The first function module for a data element’s field exit must be created without an identifier.
    To create the function module, click on the ‘Create’ pushbutton, choose menu path Function module -> Create, or press ‘F5’.
    After choosing to create the function module, you will get the warning: "Function module name is reserved for SAP". This message is just a warning so a developer does not accidentally create a function module in the field exit name range. By pressing ‘Enter’, you will be able to go ahead and create the function module.
    Before coding the function module, you will have to specify the function modules attributes -- function group, application, and short text.
    Step 5: Code Function Module
    From the function module’s attributes screen, click on the ‘Source code’ pushbutton or choose the Goto -> Function module menu path to the code of the function module.
    Here you will add your desired functionality for the field exit.
    Remember that field exit’s function module will have two parameters -- one importing parameter called "INPUT" and one exporting parameter called "OUTPUT". These parameters will be set up automatically by the system.
    You must remember to assign a value to the OUTPUT field. Even if the value does not change, it must be moved from the INPUT field to the OUTPUT field.
    Step 6: Activate Function Module
    After coding the function module, you must remember to activate it.
    Use the Function module -> Activate menu path to activate the function module.
    At this point, you can return to the field exit transaction.
    You should be able to 'green arrow' back to this transaction.
    When you return to the field exit transaction, you will see an entry for the newly created field exit.
    At this point, the field exit is global. That is, it applies to all screens that use a particular data element. On any screen that uses the data element, the corresponding field exit function module will be triggered, once it is active.
    Also, the field exit will not be triggered yet because it is inactive.
    Step 7: Assign Program/Screen
    This step is only needed if you want to make a field exit local.
    To make a field exit local, select the field exit and click on the ‘Assign prog./screen’ pushbutton.
    In the dialog box , indicate the appropriate program name and screen number.
    This information indicates that the field exit is local to the specified screen in the specified program.
    In the dialog box, you determine which function module gets executed for the field exit by specifying the identifier in the ‘Fld. Exit’ field.
    If this field is left blank, the function module triggered will be 'FIELD_EXIT_<data element>'.
    If a single-character identifier is entered into the field, the function module triggered will be 'FIELD_EXIT_<data element>_<identifier>'.
    Step 8: Activate Field Exit
    The field exit must be active for it to be triggered by the system.
    Activate the field exit by choosing the Field exit -> Activate menu path.
    After assigning the field exit to a change request, its status will change to ‘Active’ and it will be triggered automatically on the appropriate screen(s).
    NOTE : In order to activate the field exit the profile parameter abap/fieldexit = YES must be set on all application servers
    Please reward points if helpful.
    Cheers,
    Swamy Kunche

  • Steps for field Exit

    Hi friends,
    For my requirement, I have to use Field Exit.
    Can u please provide me steps/ notes for field exit.
    Regards.

    Hi,
    Follow this:
    - check data element of your field
    - go to SE37 and create a function group of your choice
    - run the program RSMODPRF
    - type your data element and run it
    - the system has to create FM for the field exit. It already suggests the name. Do not change it, just create that one.
    - assign your previously created Function Group
    - don't change the interface of the FM: input and output must be handled here in order to transport data to/from screen. Here you can check it the field fullfills your requirement
    IF input = ...
      MESSAGE 'Wrong input' TYPE 'E'.   "message type E will restart PAI and field will be input ready again
    ENDIF.
    "at the end you must use this
    output = input.   "to transport data
    - now using menu BACK function go back to program RSMODPRF and activate your field exit (Fieldexit -> Activate).
    - Don't forget to activate your FG and FM too.
    This procedure will activate Global field exit, if you want to create a local one, use the same program but Assing a screen and program to that data element.
    Regards
    Marcin

  • Need a document for field exit....urgent

    Can any one please send a document for field exit or have a simple document on how to work on a field exit with screen shots. pls send it ...its urgent
    Thanks and regards
    Nandha kumar R

    Hi,
    A field exit is a type of user exit.
    A user exit is a hook where you can inject your own add-on functionality or behavior to SAP’s standard business applications without having to modify the original applications.
    Field exits allow you to create your own programming logic for any data element in the Dictionary. You can use this logic to carry out checks, conversions, or business-related processing for any screen field.
    Field Exits
    Field exits allow you to create your own programming logic for any data element in the Dictionary. You can use this logic to carry out checks, conversions, or business-related processing for any screen field.  Example: The data element BBBNR identifies a company’s international location number. You might want to set up your R/3 System so that all international location numbers are larger than 100. 
    The field exit concept lets you create a special function module that contains this logic. 
    You assign the special function module to the data element BBBNR. You then assign the module to any programs and screens in which users can add new international location numbers. When you activate your field exit, the system automatically triggers your special routine whenever a user enters a company location number. 
    In 4.6c, you can use "RSMODPRF" program to create field exits.
    An example of a user exits :-
    MODULE user_exit_0001 INPUT 
        CASE okcode.
            WHEN 'BACK OR EXIT'.
                CASE sy-dynnr.
                        WHEN '100'.
                             SET SCREEN 0.
                             LEAVE SCREEN.
                        WHEN '200'.
    Note that you can write any code that satisfy your needs.                                                     ****
    But in this case, this was wrote as a sample code for reference sake.                                    ****
    And you can test it.                                                                                ****
                             SET SCREEN 100.
                             LEAVE SCREEN.
                 ENDCASE.
          ENDCASE. 
    Field exits (SMOD/CMOD) Questions and Answers
    1. Field exit was created with CMOD, but is not processed when calling the screen.
    -  Since the field exit is not processed until PAI, an action must be triggered on the screen (Return, Save, ...).
    -  Set profile parameter abap/fieldexit to YES and restart the system.
    -  After activating the function module FIELD_EXIT... and the field exit, leave the transaction on whose screen the field exit is to be executed. The screen is not generated until the transaction is started.
    - Do not work on different application servers since there may be some delay before the field exit is activated.
    - The profile parameter must be set on all or none of the application servers.
    - If the field exit is to only be active on specific screens, check whether you chose the correct program and the correct screen
          number (take care with subscreens).
    - Using SE51 -> Field list, check that the screen field does have a reference to a data element. In the name of the field exit use the name of the data element and not the field name.
    - After transport, field exits are marked as active but will not be processed. 
       Tip: First try deactivating the field exit once more and then afterwards, activate it again.
    2. How is performance affected by setting abap/fieldexit?
    - If a screen is generated and the profile parameter is set, a check is run on 2 tables (TDDIR, TDDIRS) to see whether a field exit must be generated for the respective field. In practice, the screen load is not generated until the screen is selected after an
    update. The user should not notice any difference because screen generation is very fast.
    3. Can you read the contents of other screen fields in the field exit?
    - In principle, every field exit can store its value in the global variables of the function group (TOP) and hence make them
    available to other field exits. Note here that field exits are always called and not only if an entry is made in the field or if the field is empty. In addition, it is not possible to make any assumptions about the order in which the field exits will be called in the future.
    4. How does the field exit behave on step loop fields ?
    - After the user has entered data, the field exit is called in PAI as often as there are visible fields in the step loop. The system
    variable SY-STEPL is incremented each time. If a new value is assigned to the field, it is displayed in the module between LOOP and ENDLOOP. This module is also called once for each visible step loop line.
    5. Can field exits be debugged ?
    - No. Field exits must be tested separately in the ABAP/4 Development Workbench. For errors which only occur in the screen environment, it is helpful to write interesting variable to the file system using TRANSFER... . These can then be analysed there.
    6. What can you do if the field contents are no longer transported to to ABAP/4.
    - Check whether a value is assigned to the field OUTPUT.
    7. When is the field exit called if a conversion exit is attached to the
       data element ?
    - The field exit is called after the conversion exit. This means that the INPUT field receives the data in the same format as the
    ABAP/4 program also receives it.
    8. Although a global field exit is inactive, a function module is called which does not exist (for example FIELD_EXIT_PROGRAMM_@)
    - This is an error in the kernel which no longer occurs as of 3.0C.  As a temporary measure, it is useful to assign a program and a screen which do not exist to the field exit and then activate the field exit.
    9. Field exit is not visible in CMOD, although created.
    - If you want to create a field exit for a data element, a function module is proposed with the name FIELD_EXIT_. This
    function module must exist for the field exit to work. If you do not create this function module, but do create one with a suffix,
    the data element is not displayed in CMOD.
    10. Field exit is not executed although it is active.
    -  Fields which do not have the 'Input field' attribute usually do not trigger a field exit. The field exit is designed to allow an
    extended input check. It is therefore only called for input fields - even if they are not ready for input at runtime of the         application by LOOP AT SCREEN.
    This rule does not apply, however, if the field is located within a steploop. Here the field will be always activated, even if it is
    invisible.
    - Field exits can only be executed for fields that are directly related tothe dictionary. If the relation is indirect, i.e. via an       ABAP declaration (  LIKE ), no field exit can be executed.
    11. Field exits on check buttons do not work
    -  Field exits are only intended for input fields. As check buttons count as graphical elements, you cannot install field exits on
    them.
    12. Field exits do not work on selection screens
    SAP Field Exits
    From 4.6c onwards, Field exits will no more be supported by SAP.  They removed the function of field exit but they had given lot of flexibility through userexit.
    However, if you still required it, here is how to activate it :-
    First called up transaction  CMOD.
    Then called up transaction PRFB.
    or
    Activation of the field exits and assignment of the dynpros can also be carried out using program RSMODPRF. For this purpose, the program must be started without parameters (input fields remain blank).  If required, new field exits can be created using program RSMODPRF (see the program documentation).
    REFER THIS LINK ALSO.
    defining screen fields using FIELD-SYMBOL
    Thanks,
    Shankar

  • Can any one tell me how to work with field exit????

    Hi
    Can any one tell me how to work with field exit I know how to create them. I want to know how it works. Actually I want to create a field exit for T-CODE MIRO. Where I want to put the value ebeln of the PO Reference tab into the Assignment of details tab and make Assignment field disable.
    Thanks in advance

    Hi,
    Follow the Steps,
    1. Go to CMOD transaction
    2. From the menu "GOTO->TEXT ENHANCEMENTS->DATA ELEMENTS-   ->NEW DE CUST DOCU".
    3. In the displayed box specify the data element and
       press either "CHANGE" or " Ref to screen" button
    4. CHANGE button is for defining the documentation
    5. "Ref. to screen" if for assigning the screen in which
       a field has the this type data element.
       Note: You should have used this data element for a   
             field in that screen.
    6. Now it will ask for Function Module name, specify the
       FM name and double click it. It will go to the editor.
    7. Now using the Import parameters code accordingly
    8. Activate and go back
    9. Now "Assign the created program ( that is FM) to the
       screen by specifying the Program name and Screen
       number.
    10. Now save and activate.
    Note: No need to create a separate project for creating field exit through transaction CMOD.
    I hope this is suffice.
    Regs,
    Venkat Ramanan

  • Documentation about Screen, Menu and Field Exits

    Hi all!!
    I need some documentation about Screen, Menu and Field Exits.
    I´m very interested specially on steps by steps.
    My mail is [email protected]
    Helpful posts will be rewarded.
    Thanks in advance and regards,
    Manuel.

    <b>Types of Exits </b>
    There are several different types of user exits. Each of these exits acts as hooks where you can attach or "hang" your own add-ons.
    <b>Menu Exits</b>
    Menu exits add items to the pulldown menus in standard SAP applications. You can use these menu items to call up your own screens or to trigger entire add-on applications.
    SAP creates menu exits by defining special menu items in the Menu Painter. These special entries have function codes that begin with "+" (a plus sign). You specify the menu item’s text when activating the item in an add-on project.
    <b>Screen Exits</b>
    Screen exits add fields to screens in R/3 applications. SAP creates screen exits by placing special subscreen areas on a standard R/3 screen and calling a customer subscreen from the standard screen’s flow logic.
    <b>Function Module Exits </b>
    Function module exits add functions to R/3 applications. Function module exits play a role in both menu and screen exits. 
    When you add a new menu item to a standard pull down menu, you use a function module exit to define the actions that should take place once your menu is activated. 
    Function module exits also control the data flow between standard programs and screen exit fields. SAP application developers create function module exits by writing calls to customer functions into the source code of standard R/3 programs. 
    These calls have the following syntax: 
    CALL CUSTOMER-FUNCTION ‘001’.
    Field Exits
    Field exits allow you to create your own programming logic for any data element in the Dictionary. You can use this logic to carry out checks, conversions, or business-related processing for any screen field.  Example: The data element BBBNR identifies a company’s international location number. You might want to set up your R/3 System so that all international location numbers are larger than 100. 
    The field exit concept lets you create a special function module that contains this logic. 
    You assign the special function module to the data element BBBNR. You then assign the module to any programs and screens in which users can add new international location numbers. When you activate your field exit, the system automatically triggers your special routine whenever a user enters a company location number. 
    In 4.6c, you can use "RSMODPRF" program to create field exits.
    An example of a user exits :-
    MODULE user_exit_0001 INPUT 
        CASE okcode.
            WHEN 'BACK OR EXIT'.
                CASE sy-dynnr.
                        WHEN '100'.
                             SET SCREEN 0.
                             LEAVE SCREEN.
                        WHEN '200'.
    **** Note that you can write any code that satisfy your needs.                                                     ****
    **** But in this case, this was wrote as a sample code for reference sake.                                    ****
    **** And you can test it.                                                                                ****
                             SET SCREEN 100.
                             LEAVE SCREEN.
                 ENDCASE.
          ENDCASE.
    reward  points if it is usefull..
    Girish

  • About field exits

    Hi Gurus,
    i have a problem, in MM01(Basic data1) there is field called Prod.hierarchy(dataelement is prodh_d), for this data element how to create Field Exits and how to assign to MM01 Tcode.
    the code part i have to write is
    1. To validate MARA-PRDHA field length (field exit can handle this). the field length should be 18 char.
    2.Copy the value of MARA-PRDHA to MVKE-PRODH (the code of the field exit above, you can do field-symbol technique to transfer value from mara-prhda to mvke-prodh).
    plz. do the needfull information with all the steps ASAP.
    Thanks & Regards,
    Sudheer.

    You can create a field exit to the data element by running the report RSMODPRF.
    You will then have to assign the the program name & screen No. (In this case the program name & screen No. in MM01 transaction.)
    You will have to write a field exit for MARA-PRDHA and within that ensure that the field length is 18char.( The input value you read should be of 18 char).
    You can read the screen field value by using the fn. module to read the screen values & put that value inside MVKE-PRODH. This can be written in another exit.
    Important Things to Note.
    1.You cannot debug a field exit.
    2. Assign the correct program name & screen no. to activate the field exit.
    3. This is written at data element level.
    Hope this helps...
    Let me know if you need any further details.
    Regards
    Deepu.
    Reward Points if it helps.

  • Field exits in MM01

    Hi Gurus,
    i have a problem, in MM01(Basic data1) there is field called Prod.hierarchy(dataelement is prodh_d), for this data element how to create Field Exits and how to assign to MM01 Tcode.
    the code part i have to write is
    1. To validate MARA-PRDHA field length (field exit can handle this). the field length should be 18 char.
    2.Copy the value of MARA-PRDHA to MVKE-PRODH (the code of the field exit above, you can do field-symbol technique to transfer value from mara-prhda to mvke-prodh).
    plz. do the needfull information with all the steps ASAP.
    Thanks & Regards,
    Sudheer.

    Hi sudheer,
    I didn;t get your question..
    Do you want to add a field to the standard screen basic data 1 and have a screen exit to handle that field?
    If this is the case check out SAP note 44410 .It talks about intergrating customer-specific fields in the material master maintenance.
    Award points if useful.
    Regards
    Parag

  • Query on Field exits in ECC 6.0

    Hi All,
    We have implemented field exits in SAP R/3 4.6c and now we have upgraded to ECC 6.0.
    I need to know the following information:
    Are field exits obsolete in ECC6.0?
    Can we create new field exits in ECC 6.0 ?
    Going forward, what is the alternative technology/concept to be used - enhancement sports, BADIs etc for field validations(or instead of field exits)?
    Regards
    Shiva

    Hi,
    Though it is obsolete, SAP does not say dont you field exit. You can still use field exit. You can still create field exits.
    Whatever is already existing will definitely work. Creating a field exit is much more simpler and easy than the BADIs or Enhancement points.
    Yes you are right, going forward, you will have to use BADIs or Enhancement points.
    Regards,
    Subramanian

  • The way how field exit gets called??????

    Hi ALL,
    Can any guru tell me how exactally the field exit works.
    Senario- I have created field exit on Data element WERKS_EXT for user validation on plant level for T-code VA01.
    Issue- I don't have proper user details in Dev. system to test this thing, for ulternative what i m doing is; I am running VA01 by putting brake point inside my Include for field exit to check it is getting called or not?
    But the control is not coming to this field exit code and it is creating sales order .
    I have checked, it is ACTIVE and GLOBLE for all screens.
    So, please tell how exactally the field exit works and how i can test this?
    Regards,
    Rahul

    Field exits can only be executed for fields that are directly related tothe dictionary. If the relation is indirect, i.e. via an ABAP declaration ( LIKE ), no field exit can be executed. Field exits cant be debugged.
    For details on field exits, have a look at below link.
    http://www.sap-img.com/abap/field-exits-smod-cmod-questions-and-answers.htm
    http://www.sap-basis-abap.com/sapab014.htm
    Best Regards,
    Vibha
    *Please mark all the helpful answers

  • Field Exit is not working in QA but working in Development Server....

    Hi friends,
                         I have created Field Exit for data element EPOS_LGORT (Storage Location) .Which is using in ME21N transaction of MM. This Field Exit is proper
      working in Development Server but after transport in QA it is not working. I have checked code , it is same as well as exist in development Server. 
                  Abap/fieldexit parameter already has been set as ‘Yes’. But still it is not working.
    Following values has been set for Parameter ‘abap/fieldexit’ for QA .       
    Dflt value                no
    ProfileVal               YES
    Current value          YES
    SAP Release         4.71
                         Any other setting required for  parameter's . Please suggest me.
    Thanks.

    Hi Chandrasekhar,
                           Thanks . Default value of parameter abap/fieldexit is 'yes or no' . Basis person told me that abap/fieldexit either can be set yes or no , so where we have to set 'X'  value for abap/fieldexit parameter.
      After execution of Program RSPARAM , following values found for  QA Server.
    1.1 R/3 C kernel               no
    2.1 file                             no
    3.1 file                             YES
    3.2 program parameters    YES
    3.3 Replace $$ and $(..)    YES
    3.4 Generate file name      YES
    4.4 Value in SharedMemory      YES
          Any other setting's  we needed ?