hello,
I have a main program in which i have two include programs. On a give condition i need to terminate first include and come back to the main program.
Can anyone tell me how to do this???

A trick could be embedding the includes by a loop statement, something like:
DO 1 TIMES.
  INCLUDE zinc1.
ENDDO.
DO 1 TIMES.
  INCLUDE zinc2.
ENDDO.
Then you can exit the include by the EXIT or CHECK statement. Somewhat 'dirty' but nevertheless also use by SAP sometimes.
regards Jack

Similar Messages

  • TS1393 I cannot eject my iPod using either itunes or the eject button on bottom tool bar beacuse it says something is in use by another application or "The device 'generic volume' cannot be stopped because  a program is still accessing it" Synced new iPad

    How can I eject my ipod when neither itunes not the "safe to eject" button will allow it.  Itunes says "...cannot be ejected because it contains files that are in use by another application."  The safe to eject button says "The device 'generic volume' cannot be stopped because a program is still accessing it."  The has never happened before.  The only thing new is that I added an iPad yesterday.  Thanks. 

    Go to your computer's System Tray and try ejecting.  If you can't eject, there is an application that is trying to access your iPod.
    Go to http://technet.microsoft.com/en-us/sysinternals/bb896653.aspx and download ProcessExplorer.
    Go to http://support.microsoft.com/kb/555665 and follow the instructions under Resolution.
    Note that this is a good, general process any time you can't access any file.
    In my case an update to RealPlayer installed a program called RecordingManager that was accessing my iPod.

  • Which is better Function modules or Include programs?

    Hi,
    I am working on an enhancement and it has lot of screens with a tree structure on the left. Now we are planning to have each screen to have its PAI/PBO and the processing logic to be in seperate include programs.
    However in our team we have debate as to go in for include programs or for Function modules. The opinion here is that the program should not take long time to load if its going to be include programs.
    Please suggest what approach is better, is it Function modules or include programs.
    Any other suggestion is also welcome.
    Thank You,
    SAC.

    Thank You all.
    In this enhancement I have about 13 screens and has business logic in each. So if I go with each screens and business logic coding in seperate Function modules than includes under 1 function group is adviceable?
    Using object oriented approach is really the best thing here, but however most of my team members are not welversed in OO concepts. The deadlines are very tight for grooming my team members as well.
    My only concern is that with so much screens and business logic in 1 transaction should not bring down this programs performance when its executed.
    Any other suggestions to keep in mind for this is appreciated.
    Thank You.
    SAC

  • How to use the variables of Function exit in the include program

    i have a problem of using the variables of a function exit in the include program..
    If i use those variables there will be an error indicating 'Field FEBVW_IN is unknown. It is neither in one of the specified tables nor defined by a DATA statement'. Please help... Below is the code of the function exit:
    FUNCTION EXIT_SAPLIEDP_202.
    ""Lokale Schnittstelle:
    *"  IMPORTING
    *"     VALUE(IDOC_CONTROL_INDEX)
    *"     VALUE(IDOC_DATA_INDEX)
    *"     VALUE(FEBVW_IN) LIKE  FEBVW STRUCTURE  FEBVW
    *"     VALUE(FEBKO_IN) LIKE  FEBKO STRUCTURE  FEBKO
    *"     VALUE(FEBEP_IN) LIKE  FEBEP STRUCTURE  FEBEP
    *"     VALUE(FEBRE_IN) LIKE  FEBRE STRUCTURE  FEBRE
    *"     VALUE(FEBPI_IN) LIKE  FEBPI STRUCTURE  FEBPI
    *"  EXPORTING
    *"     VALUE(I_FIMSG) LIKE  FIMSG STRUCTURE  FIMSG
    *"     VALUE(FEBVW_OUT) LIKE  FEBVW STRUCTURE  FEBVW
    *"     VALUE(FEBKO_OUT) LIKE  FEBKO STRUCTURE  FEBKO
    *"     VALUE(FEBEP_OUT) LIKE  FEBEP STRUCTURE  FEBEP
    *"     VALUE(FEBRE_OUT) LIKE  FEBRE STRUCTURE  FEBRE
    *"     VALUE(FEBPI_OUT) LIKE  FEBPI STRUCTURE  FEBPI
    *"  TABLES
    *"      IDOC_CONTROL STRUCTURE  EDIDC
    *"      IDOC_DATA STRUCTURE  EDIDD
    *"      IDOC_AVIP STRUCTURE  AVIP OPTIONAL
    *"      IDOC_AVIR STRUCTURE  AVIR OPTIONAL
    *"      IDOC_AVIT STRUCTURE  AVIT OPTIONAL
    *"  CHANGING
    *"     REFERENCE(IDOC_AVIK) TYPE  AVIK OPTIONAL
    *"  EXCEPTIONS
    *"      PROC_ERROR
      INCLUDE ZXF08U10.
    Here is the code for the include program.
      INCLUDE ZXF08U10
    MOVE febvw_in TO febvw_out.

    Sometimes you will get this error message when checking include code in exits even though there is really no error - it happens because the include does not realise it is in the function due to the navigation index being out of date.
    Try activating the code - it may work even though the check said there were errors.
    You can also get this issue when trying to drill down on the field in the include to view its structure.
    Andrew

  • How to exclude the standard Include programs in Code Inspector?

    I am running code inspector (SCi) on all the development objects using a package. But in certain repository objects standard include programs have been used. I want to exclude the standard include programs while running SCI on the package. What are the ways to achieve this?

    Hi,
    while defining an object set choose:(in the menu)
    Edit - Exclude View Maintenance Function Groups.
    This should exclude most or at least some of the includes from being checked.
    Kind regards,
    Hermann

  • How to perform subroutine form in an include program?

    Hi all,
    I would like to perform an external subroutine form residing in an include program from a customer function user exit. I tried using the following code, but it dumps:
    PERFORM <form name> IN PROGRAM (lv_program)
               TABLES <a> <b> USING <c>.
    In the dump analysis I see that "Program <include name> is type I and therefore cannot be generated" and "The current ABAP/4 program attempts to call the program <include name> but this program cannot be executed. Therefore,the current program had to be terminated. "
    If the include can't be generated, is there another way or method I could directly call the form without needing to copy the standard code to an own function or form?
    Best regards,
    Mikko

    Hi,
    take this example..
         perform idoc_status_record_write in program sapmsed7 using
                                                    x_edidc-docnum
                                                    c_idoc_status_ready
                                                    space
                                                    space
                                                    space
                                                    space
                                                    space
                                                    space.
    in this the from is in include, but while calling you need to call with the help of main program.
    in this case <b>SAPMSED7</b> main program, but form is in include <b>MSED7F05</b>
    Regards
    vijay

  • Problem in creating include program for customer exit for BC425_01

    Hi,
         I want to write a customer exit for transaction BC425_01. For identifying the include program for exit , i go to System->Status.There I double click on the program name(GUI).Then I perform a 'FIND' in main program for 'customer-function' keyword. I get 3 search results with "CALL CUSTOMER-FUNCTION '001' " , "CALL CUSTOMER-FUNCTION '002' " , "CALL CUSTOMER-FUNCTION '003' ".
    Now i double click on CALL CUSTOMER-FUNCTION '001'  and i am taken to the code of program where this function is called in MODULE cust_check INPUT. I double click on CALL CUSTOMER-FUNCTION '001'  and then I am taken to the function module code which contains a single statement 'INCLUDE ZXBC425G01U01 .' .
    Now I double click on this include program so that I can write my own code. But when i double click on it , a message displayed 'Program names ZX.. are reserved for includes of exit function groups'. Hence I am not able to creates this include program and write my coding.
    Kindly Help
    THANKS

    Hi Amber,
    Then you click enter button.It is asking to create object with that include name ZXBC425G01U01 in a pop-up.You  should select YES option.It will ask package . Give the package name and save.Then include program is created and allowed you to write your own code.
    Thanks,
    Prasad GVK.

  • Subroutine inconsistency due to deletion of Include program

    Hi All,
          I created an include program(saved in local object) within my report(this was previously stored in a package) and I copied a few performs and forms from my report into the include program, but then i decided to go for the code without the include and commented the include statement in my report and deleted the include program(in se38). But now when I click on the perform statement in my report it gives a message "Object ZXY not found". The ZXY is my include program. Also when I view the report in se80 I find repetitive sub routines.Also I am not able to delete the duplicate sub routines in se80.
         How can we overcome this inconsistency in duplication of subroutines, how to suppress the message and make sure the code is consistent?

    Hi,
          So currently all the performs in program are part of some other include which is part of your main program?Because if not , obviously an error will be thrown.
    Have you tried the option of rebuilding object  list for the whole program?
    Right click on the program name in SE80--> Other functions->Rebuild object List
    Regards,
    Arun
    Edited by: arun warrier on Nov 30, 2011 1:36 PM

  • Activating Include Program in Exit Function EXIT_SAPLAAPM_002

    Hi,
    Thed System does not allow me to create/activate the Include Program ZXAAPMU02. I am getting message : Program names ZX... are reserved for includes of exit function groups. Can you please help me?
    Appreciate Your Help.
    Thanks,
    Kannan

    hi Kannan,
    when you get this message, just press enter. System will ask if it should create ... just say yes and you can create the exit code.
    hope this helps
    ec

  • Stop: C0000135 The program can't start because %hs is missing from your computer

    Im helping my aunt work on her computer. When you turn it on it says Stop: C0000135 The program can't start because %hs is missing from your computer on a blue screen. Its a Satallite C655-S5132. Please help. Thanks

    If you are able to actually log into your Aunt's computer in SAFE MODE, your need to run from a command window the chkdsk /f  press enter 
    It will prompt you to reboot and it will run chkdsk during reboot.
    If it is unable to complete it is the hard drive.
    If it does complete, then:
    Run chkdsk /r     from the command window press enter
    It will prompt reboot and run during booting.
    If it completes successfully great, if not then again it is a hard drive issue. 
    If you cannot log into your computer then follow these instructions:
    Run check disk from Windows recovery environment. from recovery dvd
    1. Access Windows Recovery command  Run Check disk to fix any bad sectors on the hard drive.
    2. At the command prompt type chkdsk /f and then press enter.
    3. Now, type in chkdsk /r and then press enter.
    I am also attaching a How-To-Document in Word 2003 for the above mentioned instructions.
    I hope this helps.
    "Knowledge should be unrestricted and the most important commodity we can offer to help one another."
    Attachments:
    Repairing Windows 7 through Recovery Dics.doc ‏31 KB

  • Table for Include Programs.

    Hi,
    Can anyone tell me which table stores the include program names of a Module Pool.??
    regards,
    Ramakanth

    Thanks for your Reply..
    My exact requirement is to identify the main program for all the include programs. REPOSRC gives the include program name but i think it doesnt give the main program name from where include is fetched.
    So I need table which stores the main program / Module Pool and its includes.

  • Program  to list all include programs  from the  Sap program list

    My requirement is to display all include programs from the Sap program Table ( D010INC table and TADIR table), From
    here i have to get all include programs.Can anyone give the program code for this requirement

    well, it's your requirement and not ours, so why not try yourself first?

  • Changes in an INCLUDE Program not being transported

    Hi all,
    I have done some changes in the main program of a sapscript form in SE38. This main program calls an INCLUDE program, in which I have done some changes also. But when I transport the program, the changes done in the INCLUDE are not being transported, but only the changes in the main are transported!!
    Can anyone tell me why? I generated both the main and the INCLUDE but it still is not ok.
    Regards,
    Nelmaz

    Make sure the INCLUDE is also in the same request as that of Main Program
    Regards
    - Gopi

  • How to put display-only condition in a custom include program

    hello everyone,
    I have to make a custom include program that will be used instead of the already available 'bdcrecx1'.
    I have a couple of questions and would appreciate your help.
    I need to create a parameter with a checkbox. When this checkbox is 'X' the following 2 fields need to be greyed out, otherwise user should be able to enter values in them. How can I grey out the fields?
    Using my include I should have just the following:
    1)parameter with checkbox
    (if 'X', session and user greyed out)
    2)Session Name
    3)User Name
    Also, is there a way I can avoid putting the following onto the screen:
    1)Keep session (this will always be defaulted to 'X'
    2)No Data
    <b>Note:</b> I made a copy of 'bdcrecx1'and i'm doing changes according to my requirement.
    Thanks in advance.
    Regards,
    Fred.

    Hi,
    For your first question.
    use
    assign user command for checkbox say 'CLICK'..
    at selection-screen output.
    loop at screen.
    if screen-group3 = 'VALUE' and checkbox condition.
    screen-active = 0.
    else
    screen-active = 1.
    endloop.
    To make sure that the user enters the data in fields if checkbox is not grayed,
    do it in event
    start-of selection.
    if field is initial.
    exit.
    go back to previous screen.
    endif.
    for removing 'keep session' , check out for exits..
    Regards,
    Tanveer.
    Please mark helpful answers
    Sorry about the previous error in reply.
    Message was edited by: Tanveer Shaikh

  • Inserting an Include program into all Z programs dynamically using a BDC.

    Hi Experts.
    I've created a BDC to insert a include program (for Authorisation) into all our Zprograms.
    It works but if there is code written on the line where the include has to go it is simply overwritten by the new include.
    Is there a way to search the code lines for example to see on which line the "REPORT" statement is and
    to be able to then dynamically "Hit Enter" to insert a blank line after the report statement sothat the existing code is not
    overwritten.
    Regards
    Vic

    Thanks for sharing your brilliance.
    It's much appreciated
    If I have to insert my lines in, can I update directly from the itab or is there another process
    behind that.
    My reasoning is if there is no space for the Load-of-program and include I'll have to insert it.
    Edited by: Vic Delport on Dec 10, 2009 11:12 AM