Storage Section Settings
Hi Gurus
I put in the customizing of storage type Addition to stock "M" and in the material master I mark the flag for addition to stock this does not work as spected, when I receive a PO with 2 materials on it, they go to 902, then I try to process the posting change notice but I get error no destination storage bin could be found in storage type XXX
These 2 materials have the same storage section, and I have correctly defined a strategy to place accordingly this storage section,
The current putaway is L next empty bin, and if I change to "I" addn to stock then system allows the putaway but just for one materials automatically, with the second one I still get the error but If I manually type the bin of the storage section then It allows putaway too.
Can you explain what needs to be done to allow putaway of stock in a storage type wich is divided into 3 storage sections, 2 of them are assigned to two bins each (2X2=4bins), and the last storage section is linked only to one bin. (Total of 5 bins)
The rare thing here is that in the first 2 storage section that have 2 bins each, I can put material on it only one palled on each bin, if for some reason only half pallet is placed, then no more stock can be placed there, How to check this capacities?
And for last the strategy is that system tries to putaway first in storage section 1, if no empty bin then try in sto section 2, and if no empty bin there, then it should go to storage section 3 (wich has only one bin attached) but I want to make this bin like infinite capacity so if there is no room in the first two storage sections (4 bins) then it will go to the las storage section wich can allow addition to stock and mix storage.
Please your inputs will be really appreciated on what atrategy and capacity cetting need to be done on customizing and material master of material to achieve this.
Regards
Julio,
Better late than never...Here are the other capacity check methods:
Check 2:
=======
o SUT check must be active - if not, then config for SUT assignments to ST will not be used
o For the material no specific capacity data needs to be entered
o For the bin no specific capacity data needs to be entered
o Example:
u2022 Material: 1234
u2022 Liters per CAS: 4.800
u2022 ST/Bin: 112/112-01-01
u2022 Max Bin Weight: 1,500Kg
u2022 Total Capacity: 3,000
u2022 Stock to be placed (Weight): 907.200L = 2,721.600Kg (1L = 3Kg)
u2022 Transaction SUT: T1
u2022 Allowed SUT for ST: C1
o The system stops the transaction for the transaction SUT is not valid according the SUT allowed per Storage Type configuration. Message: Storage Unit Type is not allowed for ST112.
Check 3:
========
o The material must be created for the specific ST (WM2 masterdata view) and the maximum bin qty needs to be speicfied.
o For the bin no specific capacity data needs to be entered
o Example:
u2022 Material: 3344
u2022 Liters per CAS: 4.800
u2022 ST/Bin: 113/113-01-01
u2022 Max Bin Weight: 1,500Kg
u2022 Max Bin Qty: 750L
u2022 Total Capacity: 0
u2022 Stock to be placed (Weight): 768L = 2,304.000Kg (1L = 3.000Kg)
o The following checks were done:
u2022 Bin Quantity Check
u2022 The maximum bin qty was set to 750L (Base UoM)
u2022 The quantity of the product to be placed was 768L ( = 2,304.000Kg). This qty is more than the maximum bin quantity which is 750L (Base UoM), so according to the quantity the product may not be placed in the bin. Message: Maximum qty for storage bin 113-01-01 will be exceeded by 3.750CAS.
o Note from the above that the error message is expressed on the putaway quantity and not the capacity quantity.
o Note: No weight and volume checks are done (see the weight of transaction > bin maximum weight)
Check 5:
========
o Additional config: SPRO Logistics Execution Warehouse Management Master Data Material Define Storage Unit Types - Specify the capacity for the SUT
o For the material no specific capacity data needs to be entered
o For the bin the Total Capacity field must be filled
o Example:
u2022 Material: 5678
u2022 Liters per CAS: 4.800
u2022 ST/Bin: 114/114-01-01
u2022 Max Bin Weight: 1,500Kg
u2022 Total Bin Capacity: 3.000
u2022 Total SUT Capacity: 5.000
u2022 Stock to be placed (Weight): 907.200L = 2,721.600Kg (1L = 3.000Kg)
o The following checks were done:
u2022 Capacity Check according to SUT Capacity:
u2022 The capacity of the SUT used is 5.000
u2022 The capacity limit for the bin is 3.000
u2022 The error message is displayed stating that the placement capacity is more than the allowed (maximum) capacity:
5.000- 3.000 = 2.000 (Message: Storage Unit Type C1 exceeds remaining capacity by 2.000)
o Note that no check according weight was done. The transaction weight was 2,721.600kg vs the maximum bin weight of 1,500.000kg
o Note from the above that the error message is expressed on the putaway quantity (SUT capacity used) and not the capacity quantity.
Check 6:
========
o Additional config: SPRO Logistics Execution Warehouse Management Master Data Material Define Storage Unit Types - Specify the capacity for the SUT
o For the material enter a capacity value (WM1 view)
o For the bin enter a capacity value
o Example:
u2022 Material: 1007
u2022 Liters per CAS: 4.800
u2022 ST/Bin: 115/115-01-01
u2022 Max Bin Weight: 1,500Kg
u2022 Material Capacity per BUoM: 1.000
u2022 Total Bin Capacity: 800.000
u2022 Total SUT Capacity: 5.000
u2022 Stock to be placed (Capacity): 907.200L + 5.000 = 912.200
u2022 Stock to be placed (Weight): 907.200L = 2,721.600Kg (1L = 3.000Kg)
The following checks were done:
u2022 Capacity Check according to SUT Capacity:
u2022 The capacity of the SUT used is 5.000
u2022 The capacity limit for the bin is 800.000
u2022 The error message is displayed stating that the placement capacity is more than the allowed (maximum) capacity: 912.200 - 800.000 = 112.2000 (112.200 / 4.800 = 23.375CAS). Message: Maximum qty for storage bin 115-01-01 will be exceeded by 23.375CAS.
o Note that no check according weight was done. The transaction weight was 2,721.600kg vs the maximum bin weight of 1,500.000kg.
o Note from the above that the error message is expressed on the putaway quantity (SUT capacity used) and not the capacity quantity.
======================================================================================================
There you go (I hope I've got all the detail down).
Cheers,
Hein
Edited by: Hein Botha on Mar 23, 2011 11:18 PM
Similar Messages
-
We have 2 storage section for 1 storage type they are high frequency & low frequency. We are facing issues where most of the bin in high frequency is being taken by 1 material. for example 1 material has occupied 8 -10 pallets. We want to have only 1 or 2 pallets of that material in high frequency storage section so we can have space for other high frequency mateirals. We want to use control qty i.e. if order qty is more than 600 then pick from low frequency storage setion.
How Do I achieve this changes.Hi Kiran,
you have to distinguish between putaway and picking.
Here in this example,. "A" may high, "C" may be low freq. used material.
For putaway:
If all "A" bins are empty and you store lots of same material with "A", all "A" bins are used until they are 100% occupied by WM.
To avoid this, you may use fixed bins for each material in a "A" bin region. As an alternative (if you cannot use fixed bins) you may code own putaway strategy where the quantity of a material is checked before a "A" section bin is used.
For picking:
If you want to pick large qty from "C" and small qty from "A" you may setup removal strategy "large/small qty" but then you need two storage types which also reverts settings for putaway.
Best regars,
Matthias -
Override the storage section check for manual entries
Hi All,
I am facing a issue on Storage section search.While creating To system is giving correct Storage section according t the settings but if I would like to change the storage section to different storage section system is not giving any error message.It is giving only warning message check your enteries.
So I would like know is there is config settings to avoid another storage section selcetion which are not assignned storage search indicator.
I have checked in help.sap.com .I following information .
To set up the strategy for storage sections, see the section on activating storage section searches under Strategies in the Warehouse Management IMG documentation.
If storage section checking is active for the storage type, then the system searches in the storage type only for those empty storage bins in storage sections that have been allowed for the material being put away. When you are creating a transfer order and manually enter a storage bin, then the system checks whether the bin is in a storage section that is allowed for the material.
*You can also make an entry in customizing that permits you to override the section check for manual entries.*_
Can please advice me inorder activate the config for override the section check for manual entries or any warning message.
Thanks & regards,
SrikanthHI,
Thanks for your reply.
I want Error message.
Regards,
Srikanth P -
Storage section indicator functionality
Hi All,
Generally we are using Storage section search for WM in SAP.Previously by using this we restricting some goods movements to particular storage sections.But now this storage section search indicator functionality is not working .I have checked all configuration for storage section search .Everything seems to be correct but this functionality not working .
example: storage section indicator 001 should only be linked to storage section A, but it is also possible to put away in storage section B ?? We have only added section A to 001.
Can you please advice me what configuration settings needed to revert back the settings.
Thanks & Regards,
Srikanth P.Hi
Check wther the storage section check active indicator is set at storage type level.
Storage section is used to further divide the storage type. It will be used only for Putaway process.
Check the following also
Storage section definiition for the wh no/storagetype combination
Storage typw indicator to the wh no
Material master storage section indicator
Storage bins created with the storage section
Hope it helps
Thanks/karthik -
WM- Wrongly triggered storage section in 902 storage type
hi
I maintained the storage section( B11) in 902/ WE-ZONE . When i generated the GRN against purchase order ,
during transfer syatem storage type 902 is triggering the storage section 001.. i dont want system trigger the storage
section 001 for storage type 902..the system should generate the 902 for storage section(B11)
With Regards
Dinesh
Edited by: code acess on Dec 29, 2011 5:22 AMHi,
This is a std system behaviour, since the configuration is done like this in SPRO.Please check for the settings against storage type 902.
spro->Logistics execution->WM->Master data-->Define storage type -
>Define stsorage section
The system picks the section from here
Regards,
Velu -
Problem over storage section search
Hi all .
Actually , I'm facing a strange problem . When , I came to storage section search option , I got noticed that one of my warehouse's storage type ( RES - reserve storage type ) pre- assigned with "Y" option while activating the storage section search option - that means storage section determination but no check ....
In storage type settings , I made " storage section check " option , remains unchecked . That's fine - but , the paradox , I did the same storage type setting for other storage type , and they showed as " blank " not Y ...
my question is why it shows as Y , instead of blank ?
thanks in advance ............
regards
arghyaAs a part of the customizing and implementation of WM, you need to check this customizing step.
When you activate the storage section check, you ought to check this step too, to make sure your
ST's have this setting as required.
So, the default values for this indicator are the following:
* On check (in ST settings) => set to X
* On uncheck (in ST sett.) => Set to Blank
I don't know if there is an option to set the default values for the actions in ST settings, but I highly doubt there are. Also, it seems that in your case it didn't change it at all, so it definitely isn't standard behavior of the system.
You need to test a bit more.
E.g. set to blank, and then activate the check, go back and see what is the result.
Then set to Y manually, then uncheck it at ST level. Again, return to check the indicator.
Now, don't change manually, but go again to ST settings and activate. Return to see the indicator value.
You can try a few more similar tests if you like...
This will give you an idea of what are the rules behind the ST settings => section search indicator (X,Y,Blank).
I have tried at two system now, and both of them behave exactly like I stated before.
Whenever I check ST section search, indicator is set to X.
When I uncheck it, indicator is reset to Blank. -
iPod touch 4 gives message "Cannot Download" "there is not enough available storage to download...You can manage your storage in settings." when trying to update or install one of the apps, but not other apps. I have more space available than needed for the app. What do I need to do to fix this problem? Do I need to completely reset this device as new and, if so, how should I do that?
You need to delete some item (apps, music, photos etc) from the iPod,.However, sometime files get corrupt. To determine that connect the iPod to your computer and click on the iPod under Devices in iTunes. How much storage is used by the "other" category. If over 1 1/2 GB that indicates corrupted files.
To get the "other" down to normal value you need to restore your iPod usually restoring from backup works but sometimes restoring to factory settings.new iPod is required./ -
I have been trying to download a movie to my IPad. I have never had trouble before but the last two times I get an error message that says "Cannot Download" There is not enough storage to download your movie. You can manage your storage in Settings.
When I go to my settings it says I have 5GB remaining storage and 5GB storage used. I have deleted a lot of my music and games but am still having trouble. Has anyone experienced this before?5GB is typically not enough space to download a movie. Often, movies take from 3 - 5 GB to begin with. The only option you have is to delete more things from your iPad. You can remove unused Apps, pictures, music, text message (messages with pictures can take up a lot of space), email messages, books, magazines etc.
-
i need help! my ipad is having a problem~ i cant open my ipad because of this saying "Not enough storage -> this ipad cannot be backed up because there is not enough iCloud storage available. You can manage your storage in settings." if i click the button close it wont close and if i click button settings it wont go to settings as well. What will i do? how can i fix it? here's the pic of it.. need your help anyone?
Hi jasmin,
Did you read what Demo wrote? He wasn't saying he had a problem. He was responding to the OP who had a problem, and was providing a solution. Follow what Demo said to do....
Cheers,
GB -
I have a 4S and in the lock screen it is coming up with a screen (Not Enough Storage - This iphone cannot be backed up because there is not enough iCloud storage available. You can manage your storage in settings) it then has option close or settings.....but i am unable to click on either or turn off the phone. I have plugged it into itunes on the computer and manually backed it up but i cannot use my phone as i cant get past this message
Welcome to the Apple Community.
You might try a forced shutdown to begin with, hold down the top and home buttons together until the device shuts down, then restart it. -
I am getting a dialog bx saying "Not enough storage: this Ipad cannot be backed up....manage storage in settings" When I click settings nothing happens. The Ipad seems to be locked. How can I upgrade storage to unfreeze my I pad?
Hi karlos16,
For the error message you are seeing, I found this article:
iCloud: Troubleshooting creating backups
http://support.apple.com/kb/TS3992
"This iPhone cannot be backed up because there is not enough iCloud storage available."
This message is displayed when there is not enough storage space available in your iCloud Storage to complete your backup. You can either reduce the amount of data you are backing up under Backup Options, or you can buy more storage.
For the issue with the iPhone appearing to be unresponsive, I recommend this article for troubleshooting:
iPhone, iPad or iPod touch: Not responding or does not turn on
http://support.apple.com/kb/TS3281
Cheers!
- Ari -
I deleted my music through the "manage storage" section in the options to make room for the ios update awhile back. Now I can't get any music back onto my device through itunes. (I've tried restoring the device twice to no avail)
Try:
- iOS: Not responding or does not turn on
- Also try DFU mode after try recovery mode
How to put iPod touch / iPhone into DFU mode « Karthik's scribblings
- If not successful and you can't fully turn the iOS device fully off, let the battery fully drain. After charging for an least an hour try the above again.
- Try on another computer
- If still not successful that usually indicates a hardware problem and an appointment at the Genius Bar of an Apple store is in order.
Apple Retail Store - Genius Bar -
WM: Error occurred during storage section search (FGWM05 001)
HI friends
i done GRN 101(movement type) with mb31 for production order ..based on TR Iam trying to create transfer order i have
the below error. where i missed the configuration
"Error occurred during storage section search (FGWM05 001)"
Message no. L3 041
Diagnosis
No storage area search has been defined for this material and this
storage type.
Procedure
Contact your system administrator! Note down the material and the
storage type listed within parentheses in the error message.
with regards
dinesh
Edited by: code acess on Jun 28, 2011 8:30 AMHi
In WM customizing Please check for your warehouse/Storage type combnation the storage section search is on and valid.
IMG>Logistics Execution>WM>Strategies>Storage section search
if there is no entry then maintain it. The nest error may be storage bin. Make sure that you create storage bin for whsno/storage type/storage section combination by using LS10 or LS01N)
Hope it helps
Karthik -
The following message appears when I try to turn on the iPad..."Not enough storage..this iPad cannot be backed up because there is not enough iCloud storage available. You can manage your storage in settings." When I tap Close or Settings nothing happens
Reboot the iPad by holding down on the sleep and home buttons at the same time for about 10-15 seconds until the Apple Logo appears - ignore the red slider if it appears on the screen - let go of the buttons. Let the iPad start up.
-
Putaway in storage section PA1 is not allowed
Hello,
While creating TO against TR in LT04 system is giving error message as above said in subject line.
I have checked in LX20 and LS04 bins are there even though still getting same error.
Please let me know what could be the reasion and solution for this issue.
Thanks in advance.you get this error if the storage section check is made active in customizing transaction OMLZ
here you first define one or more storage section indicators (also named storage area indicator).
then you define a storage section search per combination of warehouse and storage type and storage section indicators and assign the possible storage section for this combination.
in the storage bins (LS01N) you enter the storage section to which this bin belongs.
in the material master you enter the storage section indicator
if a bin is determined which has a storage section that is not among the listed storage sections from the storage section search then the error you have is issued.
Maybe you are looking for
-
How can i plot a histogram with using the results of Line Length
PLS HELP.How can i prepare a histogram with using the results of line length code(It is somewhere in the middle). This is a final exam take-home question. I would appreciate if you can help? import java.awt.*; import java.awt.event.*; import java.io.
-
Photoshop Elements 7 folder layer doesn't wanted to collapse. Need help!
Hi all, Recently i purchased a catalog online, it is under .psd format and i assumed that everything is covered in layer which is editable. Not until then i downloaded and most of the content are under folder. Others work fine which i saw in internet
-
Hi I have Adobe Captivate 5.5. When I select Help >> Adobe Captivate Help, the Adobe Help application appears, but it simply goes to a web site at helpx.adobe.com. This site lists a manual for "Captivate 7". On the status bar of Adobe Help it says
-
J2EE server stops while stopping irj application
Hi We are getting Problem while trying to stop irj application before applying Patch 2 SP2 in EP 6.0. The server stops and displays message connection Lost in admin tool. Pl help me to solve the Problem. Regards Atul
-
Preparing a file in Photoshop for widescreen video in Final Cut
I have tried two ways; using the the NTSC DV Widescreen setting in Photoshop (exporting w/ PAR turned off as is recommended); preparing the document at 853 x 480 pixels. In Final Cut I am using NTSC DV 48 kHz Anamorphic for my sequence setting. The i