Storedge 3310 and format
hi,
i have the following problem:
a storedge 3310 with raid controller. i have partitioned the volume ( which consists of 6 raid 1 logical drives) into 4 partions and assigned luns to these partitions.
probe-scsi-all shows the following:
/pci@1e,600000/pci@2/scsi@4
Target 0
Unit 0 Disk SUN StorEdge 3310 0325
Unit 1 Disk SUN StorEdge 3310 0325
Unit 2 Disk SUN StorEdge 3310 0325
Unit 3 Disk SUN StorEdge 3310 0325
format shows only the first one:
0. c0t0d0
/pci@1c,600000/scsi@2/sd@0,0
1. c0t1d0
/pci@1c,600000/scsi@2/sd@1,0
2. c2t0d0
/pci@1e,600000/pci@2/scsi@4/sd@0,0
where are the other three partitions?
Hi there,
I have a similar situation where I set up a SE 3310 connected to a Sunfire V210 running Solaris 10 GA.
The SE 3310 was set up as 2 RAID 5 logical volumes, each
with 5x72GB disk drives. I also map the hosts LUNS etc...
At the V210, when I did the probe-scsi-all it sees both RAID5
logical disks as StorEdge 3310 0325 (firmware 3.25)
however when I boot up with the -rv option, it only sees one
RAID5. Where is the other RAID 5 logical drive?
I did update_drv -f sd, devfsadm; manually edit the sd.conf
to add additional controllers and LUN's (c0,c1,c2 and up to
32 LUN's for each controller, but I still do not see the other
RAID5 logical drive. Where is it?
Please help !!!
Tony
Similar Messages
-
Storedge 3310 & Dual Ultra3 Adaptor
Hi all,
A couple of things...
1. We have 2 storedge 3310 and two machines with Ultra3 Adaptors. I can not see the 3310 using the Ultra3 adaptors. If I plug the 3310 into the host controller I can see it, (but that is not ideal as it is running slow). at the 'ok' prompt I can see the 3310, but I can never get anything to display in 'format' or on the ssconsole.
commands tried:
reboot -- -r
update_drv -f sd
devfsadm -v
All with no luck. Any ideas?
2. With the 3310 I have configure one logical RAID 5 drive (5 disks) and partitioned into 4 and mapped each partition to a host lun.
I have mucked with /kernel/drv/sd.conf and put "set scsi_options=0x43ff8" into /etc/system, I can never see the anything but the first partion on the first lun.
Help please :-)Have you downloaded and installed the Ultra3 SUNWqus....packages & installed patch as in the release notes or InfoDoc 47841?
http://sunsolve.Sun.COM/data/816/816-2157/pdf/816-2157-14.pdf
http://sunsolve.Sun.COM/pub-cgi/retrieve.pl?doc=finfodoc%2F47841&zone_110=47841 -
Multi-initated LUNS on Sun StorEdge 3310
I recently received two Sun V20Zs and a StorEdge 3310, and I am asked to cluster these two machines with the 3310 as shared storage. 3310 came with two raid controllers.
My question is, could I create multi-initiaged LUNs and have these LUNs mapped by the V20Z. Reason behind having the multi-imitated LUNs is it will facilitate fail-over in case a one of the V20Z are unavailable.
V20Zs are running Fedora Core 3.
Thanks for your help.A good output that would give you a hint of a problem is iostat -En
This output reports anykind of errors to a particular disk since the last reboot. If you are seeing high error numbers, then you can move onto running a file system check - fsck - on the drive.
If you have anykind of RAID setup, check to see if any issues are being reported. Depending on what you are using to manage the RAID - Veritas Volume Manager or Solaris Disk Suite - they will most certainly tell you if there is an issue. A vxprint for Veritas and a metastat for DiskSuite will show you what you have setup and if there are any recognized disk issues. -
Not all storedge 3310 disk showing up
I have a storedge 3310 hooked to my V440 running solaris 8 and not all the logical disks are showing up in the format command. I have a total of 4 logical disks configured on the array, two on the primary controller and 2 on the secondary controller. It appears that I only have one logical drive from each controller appearing. Any help would be appreciated.
ThanksThat worked however, now when I run format I get the following errors:
8. c4t1d1 <SUN-StorEdge3310-0325 cyl 34474 alt 2 hd 64 sec 32>
/pci@1d,700000/scsi@1/sd@1,1
9. c4t1d3 <SUN-StorEdge3310-0325 cyl 34474 alt 2 hd 64 sec 32>
/pci@1d,700000/scsi@1/sd@1,3
Specify disk (enter its number): Feb 21 18:10:44 socorro scsi: Vendor 'SUN', product 'StorEdge', 70606848 512 byte blocks
Feb 21 18:10:44 socorro scsi: WARNING: /pci@1c,600000/scsi@1/sd@0,2 (sd160):
Feb 21 18:10:44 socorro corrupt label - wrong magic number
Feb 21 18:10:44 socorro scsi: Vendor 'SUN', product 'StorEdge', 70606848 512 byte blocks
Feb 21 18:10:44 socorro scsi: WARNING: /pci@1d,700000/scsi@1/sd@1,1 (sd204):
Feb 21 18:10:44 socorro corrupt label - wrong magic number
Feb 21 18:10:44 socorro scsi: Vendor 'SUN', product 'StorEdge', 70606848 512 byte blocks
Will look into thme and see if I can get them resolved.
Thanks -
Adding 146GB drives to StorEdge 3310
I have a StorEdge 3310 with 6 72GB drives in it (RAID 10). Customer wants to add a pair of 146GB drives to increase capacity. Is there any issue with having disparate sized drives in a 3310 RAID array?
I have a 3310 disk array with 12 72gb drives ,
configured raid 5 , 1 hot spare...The host side scsi
parms are max queded i/o 256, luns /host 32, max #
concurent host lun 128, cyl/head/sector
cyl-65536,head-64, sector-255...... NO problems.
I have added a 3310 expansion unit to the original
disk array. expansion unit also configured raid5 ,
one local spare. sd.conf also update. I am able to
newfs, mount and use the disk. however it odd
compared to othe disks when using the solaris format
command. questions are the OK for 146gb drives. I
noticed that one of the options for cyl/head/sector
was variable. does anyone have experience using the
option??? -
StorEdge 3310 RAID hung.
During the billing run on a Sun Fire V440, the attached 3310 hung. Reboots of the server did nothing to improve the situation, but once the RAID was powercycled everything was alright again.
sccli version 2.1.1
built 2005.09.16.23.10
build 1 for solaris-sparc
Vendor: SUN
Product: StorEdge 3310
Revision: 0325
Peripheral Device Type: 0x0
NVRAM Defaults: 325S 3310 v1.37
Bootrecord version: 1.31G
Serial Number: 07CB61
There are no "event" entries for this trouble listed in sscli, and everything comes up green. The only errors we received at the time were that of SCSI errors:
Aug 10 10:49:30 InfranetDB01 scsi: [ID 107833 kern.warning] WARNING: /pci@1f,700
000/scsi@2,1/sd@0,0 (sd16):
Aug 10 10:49:30 InfranetDB01 Error for Command: write(10) Error
Level: Retryable
Aug 10 10:49:30 InfranetDB01 scsi: [ID 107833 kern.notice] Requested Block:
289557696 Error Block: 289557696
Aug 10 10:49:30 InfranetDB01 scsi: [ID 107833 kern.notice] Vendor: SUN
Serial Number: 29C8306F-00
Aug 10 10:49:30 InfranetDB01 scsi: [ID 107833 kern.notice] Sense Key: Unit
Attention
Aug 10 10:49:30 InfranetDB01 scsi: [ID 107833 kern.notice] ASC: 0x29 (power
on, reset, or bus reset occurred), ASCQ: 0x0, FRU: 0x0
Aug 10 11:01:12 InfranetDB01 scsi: [ID 107833 kern.notice] /pci@1f,700000/scsi@2
,1 (mpt1):
Aug 10 11:01:12 InfranetDB01 got external SCSI bus reset.
Aug 10 11:01:12 InfranetDB01 scsi: [ID 365881 kern.info] /pci@1f,700000/scsi@2,1
(mpt1):
Aug 10 11:01:12 InfranetDB01 Log info 11030000 received for target 0.
Aug 10 11:01:12 InfranetDB01 scsi_status=0, ioc_status=804b, scsi_state=8
Aug 10 11:01:12 InfranetDB01 scsi: [ID 107833 kern.notice] /pci@1f,700000/scsi@2
,1 (mpt1):
Aug 10 11:01:12 InfranetDB01 got external SCSI bus reset.
[repeat]
The question is whether or not to upgrade the firmware. Since the current firmware is so old (version 3.x) there seems to be special instructions to bring it to 4.x, and eventually 4.15G. Which would include OS patches as well. (117171-12).
Or, just carry on, since this has only happened once (during the last billing run) in the last 9 runs/months.What is the difference between the host/drive channel? Besides the fact that they are their for connecting to disk drive or to host. Because lets say I connect the first RAID controller to the second one, host-to-host configuration from one RAID to another, will the host see this transparently?
By the way, I tried the JBOD method you mention so basically just connect one of the RAID unit to the other one just as a JBOD and the RAID controller can see the disks on a difference channel but only half of the disk because the RAID I/O actually have internal conneciton to half of the disk, while the other half is jumper. -
Veritas Volume manager 4.0 with Sun StorEdge 3310 D
I am running into a problem. The vxconfigd deamon always dump core when rebooting.
Our environment is listed below.
OS environemt.
SunOS server1 5.8 Generic_117350-43 sun4u sparc SUNW,Sun-Fire-V240
Software installed.
Sun Cluster 3.0
Veritas Volume Manager 4.0 MP2.
Disk Array associated.
Sun StorEdge 3310 D.
I looked up veritas.com and find Array Support Library (ASL) for Sun StorEdge 3xxx Series is recommended. But I didn't find this library is running on this server.
Please refer to this following link
http://support.veritas.com/docs/277923
As our system is one of critical systems and I'd like to confirm that I can follow up this procedure without doing harm things to our system.
JeffNo problem Jeff :)
I took a look at the Veritas doc and you're right it does seem to cover everthing.
Has the vxconfigd core dumped since the start? ie from the moment it was installed?
I have installed VXVM 4.0 with Solaris 8 but without the ASL and this worked ok, I know that's not much help to you but I am not sure the ASL will help. Mind you I have not installed it with Sun Cluster 3.0. -
Raid manager and format utility inconsistency
Hi,
I have two A1000 module attached to Sun Fire 280 R with X6541A through both channels. Here is raidutil info for (c3t4d0 and c4t8d0)
# raidutil -c c3t4d0 -i
LUNs found on c3t4d0.
LUN 0 RAID 3 381620 MB
Vendor ID Symbios
ProductID StorEDGE A1000
Product Revision 0301
Boot Level 03.01.02.33
Boot Level Date 06/16/99
Firmware Level 03.01.02.35
Firmware Date 08/12/99
raidutil succeeded
# raidutil -c c4t8d0 -i
LUNs found on c4t8d0.
LUN 0 RAID 5 172345 MB
Vendor ID Symbios
ProductID StorEDGE A1000
Product Revision 0205
Boot Level 03.01.04.00
Boot Level Date 04/05/01
Firmware Level 03.01.04.68
Firmware Date 06/22/01
raidutil succeeded!
# lad
c3t4d0 1T04469376 LUNS: 0
c4t8d0 1T03843281 LUNS: 0
Those output actually reflecting the settings,
But what format command gave me is inconsistent with raid manager:
AVAILABLE DISK SELECTIONS:
0. c1t0d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107>
/pci@8,600000/SUNW,qlc@4/fp@0,0/ssd@w21000004cf092afe,0
1. c1t1d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107>
/pci@8,600000/SUNW,qlc@4/fp@0,0/ssd@w2100002037cd9c32,0
2. c3t4d0 <Symbios-StorEDGEA1000-0205 cyl 43084 alt 2 hd 128 sec 64>
/pseudo/rdnexus@3/rdriver@4,0
Select 2 -->partition-->print
Part Tag Flag Cylinders Size Blocks
0 root wm 0 - 43083 168.30GB (43084/0/0) 352944128
1 swap wu 0 0 (0/0/0) 0
2 backup wu 0 - 43083 168.30GB (43084/0/0) 352944128
so in format, c3t4d0 is actually reflecting c4t8d0
Anyone can give me a hint,
Thanks,
WeiYeah, you probably want to go through rebuilding the device paths. This amounts to removing everything in /dev/osa/dev/dsk, /dev/osa/dev/rdsk, and /devices/pseudo/rdnexus. Then performing
a reconfiguration boot.
If you're uncomfortable with this, open a service call, or look for
the string hot_add, under Infodocs and Symptoms and Resolutions in the Sunsolve search engine.
Another string is "Syncing lad and format".
Good luck! -
Hello All,
My first connection on this forum & I would need your help.
I have to configure a Storedge 3310 (6 disks 72Gb).
Already created:
1 Logical Drive: 5 disks in Raid 5 + 1 Spare
Size of the drive: 279GB.
I need to create 11 partitions (10*12GB + 1*159GB), but apparently, I can create only 8 partitions (from 0 to 7).
Could you help me? I don't know how to do.
I already read this topic: http://forum.java.sun.com/thread.jspa?forumID=831&threadID=5098175
But the answer is not really clear (for me...)
Thx.
Eric
Message was edited by:
Eric_MdZI had to do something similar on site today, I believe (although have not tried it) that you alter the number of partitions to create on the 3320, however an alternative way of partitioning the Logical Drive is to let Solaris do it, by that I mean LVM ( formly known as disksuite). Bring the logical drive into solaris and create one large partition. Bring that single partition into LVM and then use "soft partitioning" to break it up. I have done this before and it works fine, its just another way of doing the same job albeit on the host and not on the Array.
-
Partition logical drive storedge 3310
Hi
I have Sun storedge 3310 version 413B, i create logical drive in Raid 5 configuration:
LD LD-ID Size Assigned Type Disks Spare Failed Status
ld0 68EB1906 272.46GB Primary RAID5 5 1 0 Good
and i need create 16 partitions on it, but i can create only 7 partitions:
* partitions
LD/LV ID-Partition Size
ld0-00 68EB1906-00 14.00GB
ld0-01 68EB1906-01 14.00GB
ld0-02 68EB1906-02 14.00GB
ld0-03 68EB1906-03 14.00GB
ld0-04 68EB1906-04 14.00GB
ld0-05 68EB1906-05 14.00GB
ld0-06 68EB1906-06 14.00GB
ld0-07 68EB1906-07 14.00GB
How i can create other eight partitions on ld0; i need create this configuration:
ld0-00 68EB1906-00 14.00GB
ld0-01 68EB1906-01 14.00GB
ld0-02 68EB1906-02 14.00GB
ld0-03 68EB1906-03 14.00GB
ld0-04 68EB1906-04 14.00GB
ld0-05 68EB1906-05 14.00GB
ld0-06 68EB1906-06 14.00GB
ld0-07 68EB1906-07 14.00GB
ld0-08 68EB1906-08 14.00GB
ld0-09 68EB1906-09 14.00GB
ld0-0a 68EB1906-0A 14.00GB
ld0-0b 68EB1906-0B 14.00GB
ld0-0c 68EB1906-0C 20.00GB
ld0-0d 68EB1906-0D 20.00GB
ld0-0e 68EB1906-0E 20.00GB
ld0-0f 68EB1906-0F 20.00GB
ld0-10 68EB1906-10 24.46GB
any idea?....thanksIf you are using lun mapping to create your partitions, (done by using telnet to the array and then selecting "View and Edit Host Luns") you have to tell the array the maximum numbers of luns you can create. Some systems will only let you create one by default and you can't make any changes to the size of the lun you are trying to present to your host. There is an option when you telnet to the box in the controller area for the maximum number of luns you can create. Luns in this case are partitions.
If you are not trying to partition your logical drive by using lun mapping, I don't know what your problem is.
Stephen -
Converting Storedge 3310 RAID unit to act as JBOD?
Hello, I have been struggling with this configuration, any advice is appreciated.
I have 4 x Storedge 3310 RAID units each with it own controller. I have 1 x Linux host and 1 x HBA in the host, with ch0 and ch1. I want to be able access to all 4 Storedge 3310s. Normally if this were 2 x Storedge 3310 RAID + 2 x JBOD then I just connect each RAID unit to a JBOD then each RAID to ch0 and ch1 respectively to the host. Instead what I have is 4 x Storedge 3310 RAID units, is there a way to convert two of the Storedge 3310 unit to make it act exactly like a JBOD? So that I can daisy-chain them to make them all accessible to the host?
Or adding another HBA card to the host is the only option?
thank you.What is the difference between the host/drive channel? Besides the fact that they are their for connecting to disk drive or to host. Because lets say I connect the first RAID controller to the second one, host-to-host configuration from one RAID to another, will the host see this transparently?
By the way, I tried the JBOD method you mention so basically just connect one of the RAID unit to the other one just as a JBOD and the RAID controller can see the disks on a difference channel but only half of the disk because the RAID I/O actually have internal conneciton to half of the disk, while the other half is jumper. -
I would like to know if it is possible to connect a sun storedge 3310 array to windows server 2012 r2? If ther is could you tell me how. I know how to do it on server 2003 but 2012 r2 is much different.
Hi,
I would like to know if it is possible to connect a sun storedge 3310 array to windows server 2012 r2?
Since we are not familiar with the product you have mentioned, I would suggest you contact corresponding vendor support to get more specific and accurate response.
Thank you for your understanding and support.
Best Regards,
Amy
Please remember to mark the replies as answers if they help and un-mark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact [email protected] -
Connecting to a Sun StorEdge 3310
Hello all,
in our warehouse I've found a Sun StorEdge 3310. I want to try to use it but I do not have any kind of usefull serial cable. Also StorEdge has a LAN port but I'm not able to find a mac address to force ARP table and telnet it.
Any hint to get my storage accessible?
Thanks
Stefano
http://www.stefanocislaghi.itPlease have a look at the installation document http://docs.sun.com/app/docs/doc/816-7290-19 and feel free to get back here if you still have questions.
-
I have a old storedge 3310. There is a password on there that I do not have. I'm running ubuntu 14.04 on the server. I do not have any software the came with storedge 3310. So how do go about change the password? I know that if I had all the sun software this would not be a problem but, I have not been able to find any. I'm using a serial cable to connect the 2 servers together.
ThanksDo you know the current password on the 6120?
If not, then I'm afraid you'll need a service engineer and downtime on the array to change it.
If you do know it, then you just telnet to the 6120; log in with the username 'root' and the current password and then issue the 'passwd' command.
HTH,
--A. -
Data Recovery from Partitioned and formatted Bit Locker Encrypted Drive
Recently because of some issues in windows 7 installation from windows 8 installed OS. it was giving as the disc is dynamic windows can not be installed on it. so at last after struggling hard no other solution i partitioned and formatted my whole
drive so all data gone included the drive which was encrypted by bit lockers.
For recovery i used many software such as ontrack easy recover, get data back, recovery my files professional edition but still i couldnt able to recover my data from that drive. then i found some suggestion Using CMD to decrypt my data first
http://technet.microsoft.com/en-us/library/ee523219(WS.10).aspx
where it shows it successfully decrypt my data at that moment my drives were in RAW format excluding on which windows is installed and then in CMD i check Chdsk which also shows no problem found. but now problem is still i coudnt able to recover
my data then i format the drive D and again tried to recover data using above software after decryption still no result.
Now i need assistance how i can recover my encrypted drive as it was partitioned and also formatted but decrypted also as i have its recovery key too. thanksHi ,
I am afraid that we cannot get the data back if the drive has been formatted even if use the
BitLocker Repair Tool.
You’d better contact your local data recovery center to try to get data back.
Tracy Cai
TechNet Community Support
Maybe you are looking for
-
ok im in need of some help i had just bought a brand new ipod touch from walmart and when i got it home i was trying to cope with all the new things on it and i was just fooling around like figuring where things where at and i put a passcode on my ip
-
In XML Show Form display Creator FirstName and LastName ?
Hi all, In XML Form Builder i want to display the creator FirstName and LastName ( Diamond Admin) in the Show Form. For egs: Logon ID: diamond_admin Last Name: Admin First Name: Diamond In the EDIT Form By using $sap_user and also createdBy property
-
Customizing the ICH (UIBSP)BSP application
Hi All, I am reposting my query here again.I have seen some postings related to this by PradeepReddy/Raja. Could somebody help me on this..... We have implemented the ICH and integrated it into the Portal.In this regard I want to link a BW report to
-
Working with m2v files extracted from m2t
Hey everyone. Here's a question... First, the background: I'm working with LumiereHD and a JVC GY-100U HDV camera recording in 24p. In the past, I have captured the m2t files into Lumiere, extracted the m2v and aif files, then created mov files for i
-
How to call OAF page from plsql
Hi OAF Guru's, I have a requirement to call a OAF page from a plsql procedure/function, I know how to call procedure/function from OAF pages, but I don't have any idea about how to call a OAF page from plsql. Any help is appreciated. Thanks in Advanc