Strange frm-18108 after breaking reference with an olb module

Hi all.
We have a foms10g module upgraded from a previous 6i version. As part of the upgrade process, an old olb module reference was broken, and a newer olb module was added.
Every time the form module is open it displays a frm-18108 error, saying a reference to an object is missing. The object is a pl/sql procedure which was part of the old olb library. We have checked, and there is not such reference. But it has to be somewhere although we can not see it.
I believe there was an issue when breaking the reference, but have no idea of how to fix this problem.
Any help will be greatly appreciated ...!

>
myluism Posted: Aug 5, 2010 1:34 PM
We are completely sure all objects have been removed ... Remember the object is a pl/sql procedure.... How can one miss that ...?
>
Clearly, there are still some objects from the Forms Object Library (OL) that still exist in your form or you would not be getting this error. ;) Not all objects in an OL are PL/SQL objects. They can also be Property Classes, Visul Attributes, Canvases, Forms Triggers & Program Units, etc.
Craig...

Similar Messages

  • FRM-31626: Shared menu reference detected in menu module.

    any idea to resolve it?

    you have to delete the reference in submenu inside the main menu they can not in more than one suboption

  • FRM - 18108 Failed to load following object

    when i am opening the forms in 10G suit , getting below error
    FRM - 18108 Failed to load following object
    source module : template.fmb
    source object: STANDARD
    please help me

    Sounds like you are working with the Enterprise Business Suite (EBS). The error you are getting is because Forms can't find a referenced object. This is because the directory where your TEMPLATE.fmb (and the objects the template.fmb form references) is not found in your FORMS_PATH. If you are using Windows, edit the registry and add the directory where you have your reference objects to the FORMS_PATH entry. Make sure you add it to the end of the existing value; not replace the existing value!
    Hope this helps,
    Craig B-)
    If someone's response is helpful or correct, please mark it accordingly.

  • FRM-18108 Error when opening a form with subclassed objects

    Dear Group,
    I have 2 forms in Oracle Forms 6i. One of the forms contains an object group. The other form contains the object that I subclassed it to.
    When I open the form that contains the subclassed object group, I get the FRM-18108 error.
    If I open the form with the original object group, then open the subclassed form, there is no error.
    Does this mean I must always open the original form in order to work on the one with the subclassed object group?
    I hope there is an simple solution to what is something I am missing in my Oracle Forms setup.
    Thank you in advance.
    Emad

    Hi Duncan.
    Your suggestion worked.
    Thank you for the fast response!
    Truly,
    Emad

  • Getting FRM-18108 and FRM-10102 when opening a form with Form Builder

    Hi,
    we're migrating from Forms 6i to Forms 10g. If I try to open a form in Form Builder 10g, FRM-18108 and FRM-10102 are appearing. I checked registry entries on my XP-System (FORMS90_PATH) and everything seems to be similar to the old Forms environment.
    Any ideas ?
    Thanks,
    Markus

    Hello,
    FRM-18108: Failed to load the following objects.
    Cause:  Forms could not load the foreign references specified.
    Action:  Verify that all the referenced forms and object libraries are present.
    FRM-10102: Cannot attach PL/SQL library %s.
    This library attachment will be lost if the module is saved.
    Cause:  The library you specified is locked by other users, the library name is invalid, or the library module could have been moved from or not exist in the FORMS90_PATH directory list.
    Action:  Check the library name and try again later.
    Francois

  • Does anyone know how to make songs in your playlist play directly after each other with no break between then, ie no silent period?

    Does anyone know how to make songs in your playlist play directly after each other with no break between then, ie no silent period?

    you cannot.

  • FRM-18108 When loading form (due to change in olb)

    Hello,
    I am working with oracle forms 6i and have an object library and pl/sql library that are both utilized in all forms I work with. There was a duplicate stored procedure in the object library and pl/sql library so I removed the duplicate from the object library. This stored procedure that i removed from the olb was subclassed or copied to many of the forms I work with so I have been manually deleting that stored procedure from the forms so that my application will pick up the current version in the attached pl/sql library. The forms run fine however every time I open the forms that had the subclassed library object removed I get FRM-18108 Failed to load the following objects (the message references the object library as the source module and the stored procedure that was removed as the source object.)
    I am not sure why forms is still looking for the stored procedures in the olb, I am confident that the subclassed copies from the olb have been removed form the form and there is no trace of the original code in the olb either. When running the form and calling that stored procedure it picks up the version from the pl/sql library without issue.
    Both the object library and pl/sql library are correctly attached to the form and the registry does contain the path of their physical location. The form has been recompiled several times but I can't seem to get rid of the error.
    Anyone have any idea what I can do to get rid of the FRM-18108 when opening forms that contained this subclassed unit that has been completely removed? It doesn't hurt anything but is annoying. Been searching through the forms but all I could find was issues with attaching the libraries which didn't help me on this.
    Thanks!
    Terra

    use
    SELECT      ...
      TO_DATE(decode(warrenty_flag_yn, 'Y', TO_DATE(warrenty_upto),
                                       'W', TO_DATE(warrenty_upto),
                                       'A', TO_DATE('31-MAR-'||v_year),
                                       'C', TO_DATE('31-MAR-'||v_year),
                                       'X', TO_DATE('31-MAR-'||v_year),
                                       'N', TO_DATE('31-MAR-'||v_year)
                    ),'DD-MM-RR'
             ) AS amc_date
      FROM      pc_item_procurement_history a,
    ...

  • Frm-18108 olb no longer exists

    Hi,
    i am using 10gR2 forms.
    at first i created a olb containing webutil and my bean areas. i used it for a while and then i give up using it and decided to develop different design.
    but still my forms developer gives error frm-18108(failed to load the fallowing objects with my deleted olb name.) while opening forms. in fact my forms do not subclass it anymore.
    i searched registry for olb name and deleted found ones.
    error continues when i try to open any form.
    how can i stop error message?
    thanks in advance. Engin.

    Sounds like you have it attached somewhere still. Double check that you don't have it attached in any of the forms that are called by the application or the menu or some other attached file.

  • HP Photosmart 5510 will not print Black Ink!! - Time to "break-up" with HP

    I came upon this forum by doing a google search for the issue I'm having which is my HP Photosmart 5510 will not print black ink. The printer is a year and a half old and is used only for home office use (not a heck of a lot of printing being done)
    It started right after I installed new ink cartridges (all four of them) I want to mention hear that I ONLY buy genuine HP ink cartridges from Staples and when I replace my cartriges I replace all four at the same time even if one ink level is not considered "replaceably" low. When the issue started I thought I must have gotten a bad black cartridge so I went out and bought another one but was still having the issue. So that's when I did my google search.
    I tried all the suggestions (several times) on this post (which did not reslove the problem) : http://h30434.www3.hp.com/t5/Printing-Issues-Troubleshooting/HP-Photosmart-5510-will-not-print/m-p/1...
    and I tried a "Hard Reset" as suggested here (again did not resolve the problem) :  http://h30434.www3.hp.com/t5/Ink-Toner-Cartridge-Printhead-Issues/Photosmart-5510-Will-not-print-in-...
    After trying all of these my color ink is less than half full....remember....I started with 4 brand new ink cartridges...so now, I'm out roughly $85 in ink just trying to resolve a problem that should not have happened in the first place!! Shame on HP for makeing such poor quality products. I gave up on HP computers years ago and now I'm giving up on their printers!! This HP Photosmart 5510 All In One printer replaced an HP Color Laserjet CM1312nfi printer (which cost approximately $400) that only lasted about 3 years. Sorry HP but that's it....I'm moving on! Consider this our "break-up" letter. 

    Hi TisKate, sorry to hear that you are having printing issues when it comes to printing in Black. I am also sorry to hear that you are breaking up with HP. I would like to offer a couple more troubleshooting steps before we say our fond farewells. Now this might sound silly but really it isn't. If you have the power cable connected to a Power bar/strip, please remove it and connect the power cable directly to a wall outlet. HP printers already have a built in surge protector and if you have it in a strip/bar, the printer will not get all the power needed to function properly. This can cause printing issues or false error messages on the printer display screen. Here is a document that explains the Issues when Connected to an Uninterruptible Power Supply/Power Strip/Surge Protector. 
    The other step I would like to take is on the printers display touch screen. Please use the right arrow key and go to the Wrench icon. Press the wrench and go to the Tools menu. Once in the Tools menu, please select Clean Printhead. Use the cleaning utility 2-3 times or until you see a change in the print status reports. It might take a few cycles but I am confident that it will make a difference.
    I hope you and HP can still be friends( friendly humor).
    Thanks for your time. 
    Click the “Kudos Thumbs Up" at the bottom of this post to say “Thanks” for helping!
    Please click “Accept as Solution ” if you feel my post solved your issue, it will help others find the solution.
    W a t e r b o y 71
    I work on behalf of HP

  • FRM-18108: Failed to load the following objects

    FRM-18108: Failed to load the following objects
    I get the following error when I open a form that references an object library. The repercussions of this is that the window settings are affected in the main form and several other calling forms.
    FRM-18108: Failed to load the following objects
    What do I need to do to resolve this? I need to fix this in NT and then upload the forms to Solaris to be compiled and then deployed over the web.
    I need solutions for NT and what I need to do on Solaris.
    Thanks

    Hi
    at least for NT, you must place IN ALL the FORMS60_PATH (regedit of yourNT) of your regedit,the directories where you have the libraries, menus, etc, and of course your forms.
    I suggest you: place your own directories in the first place of the forms60_path's item. then, repeat the attaching and compiling.
    I hope it helps U
    bye

  • FRM-18108

    Hi to All,
    I am working on a Client-Server Application, Oracle 6i Forms.
    My application is running perfect no problem.
    I have worked on different forms of this application previously, tested and then moved to the production (by push).
    One of the forms when opened gives me this error.
    FRM-18108: Failed to load the following objects
    Source Module:fsc
    Source Object: FSC_STD00
    so on.
    Under "Object Groups"
    I can find all the source object which were not attached, they all have the red arrow of a subclass object.
    whe the subclass Information for these object is clicked you get this message.
    "Could not find the source object. Press view to view....."
    If view is pressed the information presented is all grayed.
    but the option button "Object" is select and in the text field "Module" has fsc. I found a form "fsc" which has all the source objects but if they were attached from the form then if I open the fsc form first and then the error form then I should not get this error.
    If these are attached through a Object library, and I can't find the library anywhere then how is this application running.
    After creating an exe for a form which has referenced objects from a Object library, then if the object library is lost, does the form exe function properly.
    Can somebody help me regarding this issue.
    thanks
    Habeeb

    Thanks to all who viewed this thread.
    The answer to my own question is, If a object library is attached to a form, then the form is compiled the exe created works fine even if the object library is deleted. Reason Why.
    When the form is compiled the object library is embeded in the exe, meaning whenever the object library is modified the form has to be compiled again to reflect the changes or else the old version is still there.
    Where as in pll libraries they are attached at run time, meaning whatever the new version is or the latest version is attached when form is called.
    That is the reason my applications are working properly even though the object library is lost.
    Habeeb.

  • Urgent: FRM - 18108: Failed to load the following objects.... in R12

    Hi,
    I am unable to open forms,
    even it opens with this following error, as well all form fields are not coming.
    anyone give information.
    Please see this following error message:
    FRM - 18108: Failed to load the following objects.
    Source Module: APPSTAND
    Source Object: STANDARD_PC_AND_VA
    Source Module: APPSTAND
    Source Object: STANDARD_TOOLBAR
    Source Module: APPSTAND
    Source Object: STANDARD_CALENDAR
    Cheers from..
    M.K.Thamaraiselvan

    Hi,
    i used to get this following error also, while connecting from windows desktop
    FRM - 18108: Failed to load the following objects.
    Source Module: APPSTAND
    Source Object: STANDARD_PC_AND_VA
    Source Module: APPSTAND
    Source Object: STANDARD_TOOLBAR
    Source Module: APPSTAND
    Source Object: STANDARD_CALENDAR
    FRM-10102: Cannot attach PL/SQL library APPCORE.pll. This library attachment will be lost if the module is saved.
    FRM-10102: Cannot attach PL/SQL library GLOBE. This library attachment will be lost if the module is saved.
    FRM-10102: Cannot attach PL/SQL library JE. This library attachment will be lost if the module is saved.
    FRM-10102: Cannot attach PL/SQL library FNDSQF. This library attachment will be lost if the module is saved.
    FRM-10102: Cannot attach PL/SQL library JA. This library attachment will be lost if the module is saved.
    FRM-10102: Cannot attach PL/SQL library JL. This library attachment will be lost if the module is saved.
    FRM-10102: Cannot attach PL/SQL library VERT. This library attachment will be lost if the module is saved.
    FRM-10102: Cannot attach PL/SQL library CUSTOM. This library attachment will be lost if the module is saved.
    FRM-10102: Cannot attach PL/SQL library APPDAYPK.pll. This library attachment will be lost if the module is saved.
    FRM-10102: Cannot attach PL/SQL library GHR. This library attachment will be lost if the module is saved.
    FRM-10102: Cannot attach PL/SQL library PQH_GEN. This library attachment will be lost if the module is saved.
    FRM-10102: Cannot attach PL/SQL library PSAC. This library attachment will be lost if the module is saved.
    FRM-10102: Cannot attach PL/SQL library IGILUTIL. This library attachment will be lost if the module is saved.
    FRM-10102: Cannot attach PL/SQL library GMS. This library attachment will be lost if the module is saved.
    FRM-10102: Cannot attach PL/SQL library APPCORE2. This library attachment will be lost if the module is saved.
    FRM-10102: Cannot attach PL/SQL library FV. This library attachment will be lost if the module is saved.
    FRM-10102: Cannot attach PL/SQL library OPM. This library attachment will be lost if the module is saved.

  • FRM-18108 Failed to load the  objects

    I have upgraded the forms from 4.5 to 6i and when I tried to open the form PCOECU20 it gives me error
    FRM-18108 Failed to load the following objects:
    Source Module: PCOEar10
    Source Object: STRUCTURE_NAME_QF_LOV
    Source Object: pc_object_Group1
    ... and several others...
    The form and libraries (pll, plx) are in the same directory.
    Can anyone help?

    Make sure you upgrade any object libraries or reference forms before the forms thta depend on them.
    Also set your Forms60_path explicitly so you know that you are using the correct versions

  • Serious problems after Mavericks installation with External Drive Lacie P9220.

    Experiencing serious problems after Mavericks installation with External Drive Lacie P9220 1TB. Mac Finder totally locked!
    I had to format the External hard drive with a Windows PC (fat32), then format again with my IMac (mac Journal.) and hopefully restored data from time machine backup.
    So far so good but system looks unstable. Some software were not able to write on the hard drive.Some strange things happens. With Mountain Lion never had an even minor issue.
    I read many discussion regarding problems with WD, just wondering if anyone had the same problems with Lacie and if there is any tip to solve the
    problem.
    Many thanks.
    Marco

    Thanks very much for your reply.
    Unfortunately I couldn't find a solution because the article refers to whom have configured the drive with included software and drivers that came with the drive.
    This is not my case, I never used any third party soft ...only OS X disk utility ...
    best
    marco

  • [Solved] Strange font problem - after update.

    Hello guys,
    encountered a strange small font problem on sites with code wrappers like stackoverflow/blogs/jsfiddle. After update. took a look at my font setup all looks good.
    I've also checked the settings for gtk2/3 and no problems there.
    INFO:
    Google-Chrome-Beta. [same thing]
    Firefox [same thing]
    /etc/vconsole.conf ->
    KEYMAP=sv-latin1
    FONT=ter-112n
    .gtkrc-2.0->
    gtk-theme-name="Clearlooks"
    gtk-icon-theme-name="Faience"
    gtk-font-name="Tewi 9"
    gtk-cursor-theme-name="Adwaita"
    gtk-cursor-theme-size=0
    gtk-toolbar-style=GTK_TOOLBAR_BOTH
    gtk-toolbar-icon-size=GTK_ICON_SIZE_LARGE_TOOLBAR
    gtk-button-images=1
    gtk-menu-images=1
    gtk-enable-event-sounds=0
    gtk-enable-input-feedback-sounds=0
    gtk-xft-antialias=1
    gtk-xft-hinting=1
    gtk-xft-hintstyle="hintfull"
    gtk-xft-rgba="none"
    /gtk-3.0/settings.ini->
    gtk-theme-name=Clearlooks
    gtk-icon-theme-name=Faience
    gtk-font-name=Tewi 9
    Any ideas on this problem would be greatfully appreciated.
    http://imgur.com/MD7yPI2
    Mod note: removed huge image -- WorMzy
    Last edited by Learning (2015-05-22 21:55:07)

    Update:
    Tried reinstalling, change the fonts, remove all font clear the cache.
    change, look up the settings, looked up size, tried monitor dpi.
    checked all the config files for anything remotely related to this problem.
    Had a quick look at the bug tracker for google-chrome-beta as well no reported
    font problems as far as i can find.
    Update2:
    Tried adding custom.css to the browser not even that worked.
    update3: [SOLVED]
    So i solved the problem.
    The problem was a faulty font that was stuck and used in the pre somehow.
    Removed and added another to the list and somehow that worked.
    recommendations - if anyone has this problem in the future.
    open firefox and look in the font tab what is used. and remove that
    or try to install a fixed one. that should work.
    -Nothing has yielded any working results.
    So any ideas at this point would be most appreciated.
    Thanks,
    -L
    Last edited by Learning (2015-05-22 21:59:14)

Maybe you are looking for

  • Object-group with network-object containing an IP address range

    Hello, Does the ASA treat an object-group with a network-object containing a range of IP addresses as a netmask? For example, I can apply this configuration without the ASA throwing any errors though the configuration calls for a 'net mask': object-g

  • How to clear noted items for a vendor

    Hi Gurus, User has crated a noted item in F-47, when i run FBL1N for that vendor and select the noted itmes option, it shows open itmes which i created using F-47, now the user do not want to pay the Vendor. How can i clear the doc which i have creat

  • New G/L account assigment MATD Excise Transaction Type

    Hi expert I need to assign a new G/L while performing TCode J1is,i am using Red Doc Type MATD Regard Nabil

  • Converting CMYK to Spot Color (InDesign/Illustrator)

    I have come across a client that have sent files built in process or CMYK.  We want to make it a 2 color job (2 spot colors) but they have not chosen colors.  What is the most effective way to determine the spot color that matches the CMYK procees wi

  • Toplink 10g to 11g migration advice.

    We have application that was completely developed JDeveloper 10.1.3/4 with Toplink, JSF, ADF, and Session Facade; extremely similar to the SRDemo. I want to upgrade to JDeveloper 11g, and will probably just let JDeveloper to automatically migrate the