Hi,
We need to create 2 sub types for the custom infotype which is already existing.
Please provide your inputs
Thanks
Raju

hi raju,
i believe that the the custom infotype which you created  didnt have any subtype and subtype table created intially.
If it had , then it would have a little simpler to just change subtype table in V_t582a or maintain the extra entries in V_t591a table.
In case the custom infotype didnt have any subtype information maintained intially, then you can proceed in the same way by
introducing the subtype table in V_t582a or updating v_t591a.
But you will have to ensure that after the customising is done, all the available records maintained for the custom infotype should have the subtype field updated via a utillity program.
Let me know incase i misinterpreted your question.
Thank you,
JOse

Similar Messages

  • Subtype for custom INFOTYPE

    Hi all,
    My requirement is to Create Custom Infotyp 9100 with two new subtypes(9001 & 9002).
    Subtype 9002 will pick up relationship data from the subtype of Infotype 0021
    IT9801 u2013 Subtype 9001
    PERNR     EmpNo     NUMC     8
    ZISNo     Serial No     NUMC     4
    VORNA     First Name In Passport     CHAR     25
    NACHN     Last Name In Passport     CHAR     25
    MIDNM     Middle Name In Passport     CHAR     40
    IT9801 u2013 Subtype 9002
    PERNR     EmpNo     NUMC     8
    ZISNo     Serial No     NUMC     4
    VORNA     First Name In Passport     CHAR     25
    NACHN     Last Name In Passport     CHAR     25
    MIDNM     Middle Name In Passport     CHAR     40
    SUBTY     Relationship Serial No     CHAR     4
    The field SUBTY should display as drop down by picking up the subtypes  related to Infotype 0021 from the table T591A
    Can you please provide ur inputs as this is very urjent requirement .Step by step procedure will be of great help.
    Thanks in advance.

    Transaction to create an infotype is PM01. See online help there.
    You have to create the PS structure first (SE11). This structure containms the fields, look at existing infotype for example.
    hope it helps.

  • Creation of subtype for custom infotye

    hi,
    I have a requirement to create a subtype for custom infotype for particular fields and same fields can be able to see in T-code pa30 for corresponding infotype and subtype .
    Kindly tell me the steps or proceedure to create subtype.
    Thanks in advance
    Shweta

    hi,
    you can achieve this using PM01 transaction and some functional configuration.
    for more details search in ERP HCM Forums.

  • Custom Subtype table for custom Infotype

    Hi,
    How can I have a customer table Z* as subtype for an infotype? In PM01 I can set a Z table and field in infotype settings, but an error occurs when genarating my infotype.
    I would like someting similar to IT 2006 in my custom infotype where I would have a specific Z table as subtype (not a generic one like t591a) so that new entries in that Z table appears as new subtype options.
    Thanks and regrads.
    Sérgio.

    Hi,
    The Subtype Table doesn't contain the Subtype Field.
    For Example: PM01 for IT 2006 has Subtype Table T556A, Subtype Field KTART (which is not part of T556A).
    KTART is a field in the IT2006 Structure itself.
    Subtype Table is used just for the Values of the subtypes, Texts, Time Constraints and Object IDs.
    Can you mention what the Structure of Z table is, and what the Subtype Field is.
    Thanks,
    Suryakiran D.

  • Time constraint 'T' for custom infotype

    HI experts,
    Im creating a custom infotype and i want to assign time constraint 'T' for that infotype. But while assigning the time constraint in Infotype characteristcs in PM01, it throws the below error message.
    "TIme constraint T is not allowed for 9021 infotype".
    Pls tell me what is the pbm here and how to solve the problem?

    Hi,
    Try this.
    If a subtype needs to be maintained for the Infotype then some additional steps also needs to be performed
    before providing Infotype characteristics
    1. Select the Technical attributes from the initial screen of PM01 transaction .You will see a list of RP_XXXX where XXXX is infotype.
    2. Select the change button on application tool bar. The dialog module in the above screen then becomes
    editable.
    3. Select the Infotype 9021 and select the details button. Make sure you are in change mode.
    4. Provide the Subtype field of the Infotype, Subtype table as T591A and Subty.text table as T591S.
    5. Save and go back to the initial PM01 screen.
    6. The subtypes for an Infotype can be entered via the maintenance view V_T591A.
    Now try maintaining time constraint T with view V_T582A through SM31.
    cheers
    Ajay

  • How to create Subtype for an Infotype

    Hi,
    Can you please help or guide me to "create Subtype for an Infotype"..
    Eg: I need to Create for IT0009 a Subtype...
    Regards,
    Spaul

    Go to Transaction PM01.
    2) Enter the custom Infotype number which you want to create (Should be a 4 digit number, start with 9).
    3) Select the u2018Employee Infotypeu2019 radio button.
    4) Select the u2018PS Structure Infotypeu2019.
    5) Click on Createu2026 A separate table maintenance window appearsu2026
    6) Create a PS structure with all the fields you want on the Infotype
    7) Save and Activate the PS structure
    8) Go back to the initial screen of PM01.
    9) Click on u2018Allu2019 push button. It takes a few moments.
    10) Click on u2018Technical Characteristicsu2019. Infotype list screen appears
    11) Click on u2018Changeu2019(pencil) button
    12) Select your Infotype and click on u2018Detailu2019 (magnifying glass) button
    13) Give u2018T591Au2019 as subtype table
    14) Give u2018T591Su2019 as subtype txt tab
    15) Give your subtype field as subtype field
    16) Save and come back to PM01 initial screen
    17) Click on u2018Infotype Characteristicsu2019 u2026 Infotype list screen appears
    18) Click on u2018Changeu2019 (pencil) button
    19) Click on u2018New Entriesu2019
    20) Enter your Infotype number and short text
    21) Here we have to set different Infotype Characteristics as per the requirement. (Better open another session with some standard Infotypeu2019s infotype characteristics screen and use as the reference to fill yours)
    22) Save your entries.
    23) Now the Infotype is created and ready to use.
    24) If you want to change the layout of the Infotype as per your requirementu2026
    25) In the PM01 initial screenu2026Select u2018Screenu2019 radio button and give 2000 as the screen name, then click on edit.
    26) In the next screen.. Select u2018Layout Editoru2019 and click u2018Changeu2019.
    27) Screen default layout appearsu2026here you can design/modify the screen..change the attributes of the fields..etc.
    28) Save and activate. (Donu2019t forget to u2018Activate at every level)

  • Logical database PNP not retrieving data for custom infotypes.

    Hi all,
    I am using logical database PNP in a program. I have declared infotypes as follows:
    INFOTYPES: 0001, 0002, 0041, 9801, 9840.
    The problem is that the logical database is retrieving data for the standard infotypes but not for the custom infotypes. Any explanation as to why data for custom infotypes is not being retireved and how this can be solved will be greatly appreciated.
    regards,
    Hamza

    solved

  • T code for custom infotype in PA

    Hi
    T code for custom infotype in PA.
    Regards
    Sudha

    Hi Sudha,
    PM01 is the tcode.
    Similar questions were already answered in the following threads
    ABAP HR : Infotype Enhancement
    So please search and then post specific queries.
    rgds
    gayathri

  • How to upload data for custom infotype

    Hi  Friends
    Can we use HR_INFOTYPE_OPERATIONS   FM  for custom infotype too  or is there other way or other Standard FM to upload data for custom infotype  starting with 9000..etc.
    Points will be there for sure.
    Thanks
    Meeta & Roopa

    Thanks for quick response.
    my qns is can we use Standard FM like HR_INFOTYPE_OPERATIONS  for custom infotype too ?
    in my requirment  input will come from portal form and in background  Java Wd is going to use these FM  but i have this big  doubt can we use these standard FM for  uploading data in custom infotype as well or else is there any other way.. but for sure we can't use BDC and LSMW in this requirement .
    Thanks Meeta & Roopa

  • E-Recruiting : Creation of Search Profile for custom infotypes

    Dear experts,
    Can anyone let me know if you have created search profiles for custom infotypes in eRecruiting?
    The requirement is for the TREX to be able to search for Candidates based on the fields which are defined in this custom infotype. This infotype (9999) is completely custom defined mapped to object NA.
    In the IMG,
    I don't have to change the search profile type
    I created a new Z Information category.
    Here, i have to specify an extraction class for this Z Information Category.
    Can anyone please tell me what this should be? Can i give it as "CL_HRRCF_CEC_INFOTYPE" ?
    Also, can anyone please mention the significance of the table "T77RCF_SPT_INFTY " and how we should be handling the entries here for our custom infotype ? Should we create a custom class to specify here? How should we do this ?
    Any inputs & thoughts regarding this will be invaluable.
    Needless to say, i created the Z information category with the class CL_HRRCF_CEC_INFOTYPE but when i run the report RCF_RECREATE_SEARCH_PROFILE,It is giving me a lot errors.
    Please help.
    Regards,
    Sowmya

    Sowmya,
    To answer your question, Yes, automatic generation of NA for newly hired/created PERNR (P) is because of the integration you have activated between PA and eRecruit via BADI implementations. Look at OSS note 997181 for details on how integration works.
    If you dont need integration between PA and eRecruit on PA40 then you may have to tweak the BADI's.
    regards
    Sridhar Kandisetty

  • Currency config for Custom Infotype

    Hi Guru's,
    Can any one guide me how to config the currency for Custom infotypes.
    Regards,
    Reddy

    Hello,
    If I was to do it and under the exposed conditions I  would have to make a batch input report that would create a cut in your infotype from the currency change start date and record - convert all previous record to new currency.
    There is a few standard program created back when the euro came into play that you could have a look at so to replicate behavior for your custom infotype. Report is RPUEMU00, you could have a look at subroutines PROCESS_INFOTYPE_TABLES, PROCESS_PA0015, or maybe just custom abap logic will suit you better.
    Cheers.

  • Change layout of Adhoc query output list for Custom infotype

    Hi All,
    The fields in the Infoset query output on a custom infotype are aligned with the fields u2018payment typeu2019 and u2018amountu2019 appearing repeatedly(in columns) as declared in the Infotype and the output will be a long horizontal list.
    Instead, the requirement is that the output list should show vertically so that If I choose u2018Payment Typeu2019 and u2018Amountu2019 as output fields, it will show a long vertical list as in the case of a standard infotype (IT0008).
    Also, this way enables user to use Payment Type as a selection criteria so as to just pulling the needed payment type. When we use IT0008 in the infoset it works fine but in custom IT it does not work.
    Any pointers/suggestions on how we can achieve this would be helpful.

    Hi yu liang,
                     You can find vendor list having Vendor No. & without showing total liability for every vendor.
    after executing the report,
    1.You need to select "change layout (ctrl+F8)",
    a small window comes, it has two part -> column content & hidden fields.
    then u select "Vendor" from hidden field & move it to column content.
    2. at column content there is a column named "Total". u need to remove check for your column name "amount".
    now select "copy" button or enter. u will find the req. report.
    u can save it also by ur name.
    hope its helpful to u.......
    plz, reward points as a way of thanks if helpful...

  • Problem in creating help input for custom infotype creation

    Hi,
    I had the task of creating a custom infotype for storing recruitment test result.
    I created it using the following structure:
    Component ______________Data Element
    TEST_TYPE______________ZTEST_TYPE
    TEST_DATE
    LOCATION
    PIC_____________________RFPER
    EX_PIC
    TEST_RESULT____________ZRESULT_TYPE
    STATUS_________________ZSTATUS_TYPE
    OTHER_POSITION_________PLANS
    Now for the component other_position for the entry help i use is H_T528B with check table T528B. My objective is, when the infotype is accessed through pa30 and user is inputting the entry, when they press F4 on the inputbox for other_position, help search should show the list of all position within the system. But rather than that, the input help display such message:
    No values selected
    Maintain entries?
    Yes       No         Cancel
    When I choose yes, the input help suddenly prompt me to "Choose customizing project"  which i believe is from SPRO.
    How do I fix this problem so that when I press f4, the help will shows all position within the system.
    Thanks

    not answered, but found another work around

  • Error for custom infotype in PPOME

    Hello Experts,
    I have created one custom OM infotype for object position.Now when i am trying to acccess that Infotype in PO13 it is working fine but when i am trying to acccess the custom infotype in PPOME it is giving a dump.
    EERROR:
    Error in the ABAP program "SAPLRHOMDETAIL_PP01" had to be terminated because it has come accross a statement which cannot be exceuted.
    An exception occurred.
    The exception, which is assigned to class 'CX_SY_ASSIGn_CAST_UNKNOWN_TYPE', was not caught in procedure "INIT_SUBSCREEN" "(FORM)" nor was it propagagted by raising clause exception.
    The reason for the exception is :
    The type "" dynamically specified with ASSIGN....CASTING TYPE is unknown.
    Please guide me where i am doing mistake.
    Thanks in advance.
    Shweta

    Hi Sudha,
    PM01 is the tcode.
    Similar questions were already answered in the following threads
    ABAP HR : Infotype Enhancement
    So please search and then post specific queries.
    rgds
    gayathri

  • ALE/IDOC-How to create Change Pointers for Custom Infotype

    Hi,
    My requirement is to transfer custom OM infotype changes using IDOCs.
    But its not creating any change pointers for that infotype.
    The message used is a copy of standard message OM_HRMD_A.
    Can any one please help me out in this issue.
    Thanks,
    Sarika

    Hi Sarika,
    How did you solve this issue? We are also facing a similar problem, it will be helpful if you could explain how you found out the solution.
    Thanks
    Anu.

Maybe you are looking for

  • I can't tell if I have Mozilla 5 or Firefox 3.6. But it always says it is in SafeMode. How do I get out of safe mode?

    There are no more details. Firefox is listed as being in Safe Mode and everytime it opens I have to request that it either open in Safe Mode or choose the settings I want and then start up Firefox, but it never retains the new settings and goes back

  • How to create a swatch library from multiple png files?

    Illustrator CC I am having a difficult time trying to create a new swatch libray of patterns from multiple png files. The way I am doing this is very slow and repetitive and seems silly for a tool as advanced as the latest CC suite including illustra

  • Ow do I resolve an incorrect name or password error?

    Salut! I have two comps. All were connected to FirefoxSync. After last update to v.19, the second computer stoped sync - incorrect name or password error. I have set new password on the main computer and copyed recovery Key. Then I have done the next

  • Set the records in ALV output table

    Dear Experts, How to set the number of records in the ALV output as 10..i.e .. When user executes WD application the output of the ALV output table should contains only 10 records in every page. Thanks in advance.

  • Reminder letters for Partial delivery

    Hi,   I am configuring the Remider letter printing to Vendors in my system. Will like to know if the Standard SAP supports to print the reminder/Urging letters for partial deliveries. If the PO is of 100 qty and 60 is already delivered.Can we get thi