Successfully processed messages did not generate files

Hi,
I have a situation with file interface were XI is generated text files. I have several successfully messages out of which only some messages created files but not all. I checked the FTP but don't see all the files. Where do I need to start looking or troubleshooting? How can I rerun the successful messages to create the file? I cannot rerun the program otherwise I will duplication in R/3.
Thanks,
Sangita

Hi Sangita,
start having a look at the runtime workbench -> adapter engine where you'll see the status of your messages at adapter engine level.
Could it be that you set the append mode so every time the file content is just appended? try adding a timestamp when you generate the file, just to check if everything is ok.
Are you using condition to create the files? maybe this could be a reason, check the message payload from SXMB_MONI.
If messages are in error in SXMB_MONI you can restart them from there, otherwise if they are in error in the adapter engine you can restart them from RWB.
Hope it helps,
Kind Regards,
Sergio

Similar Messages

  • SQL 2012 - SSIS Error -The step did not generate any output. The return value was unknown. The process exit code was -1073741819. The step failed.

    Hi guys 
     Trying to run this package on SQL 2012 agent  and getting below error . No more details I could find so far.
    The step did not generate any output.  The return value was unknown.  The process exit code was -1073741819.  The step failed.
    About Package - Its connecting to different version (2000,2005,2008,2008R2,2012) servers and putting Jobs information into one Database table.  
    Any workaround or fix ?
    Thanks
    Please Mark As Answer if it is helpful. \\Aim To Inspire Rather to Teach

    New package or one that used to work? Connecting how? How does it poll?
    On the surface it is an error from a memory space of the binary/non-managed code, so nothing can be really concluded based on what you decided to share with us.
    Arthur My Blog
    So Same package is working fine from my local machine which has SQL 2008 R2 and SQL 2012 installed. I am trying to push the package on server which has sql server 2012 Installed . 
    I don't see any error .
    I ran package manually from server using SQL Data tools and ran successfully...
    Please Mark As Answer if it is helpful. \\Aim To Inspire Rather to Teach

  • Objects did not generate successfully

    Dear all,
    while applying patch 8444110, i got error below and select Yes to continue.
    Please advise what to do after finishing apply this patch. and where to find the cause of this error.
    Thanks in advance.
    Regards,
    Error in path # 8444110
    The following Oracle Forms objects did not generate successfully:
    ap forms/US APXHOLDS.fmx
    ap forms/US APXINWKB.fmx
    ap forms/US APXIWALL.fmx
    ap forms/US APXPAWKB.fmx
    ap forms/US APXSUMDS.fmx
    ap forms/US APXPWALL.fmx
    ap forms/US APXPMTCH.fmx
    ap forms/US APXSUMPS.fmx
    An error occurred while generating Oracle Forms files.
    Continue as if it were successful [No] : yes
    Connecting to APPS......Connected successfully.

    Hi,
    Not all, just the forms which adpatch failed to generate. You need to select AP product, then select specific forms. When it prompts you to generate pll files in addition to forms, enter Yes.
    You can find more details about adadmin and generating forms files in "Oracle Applications Maintenance Utilities" and "Oracle Applications Maintenance Procedures" guides.
    11i (11.5.10.2+ virtual) Documentation Library
    http://download-uk.oracle.com/docs/cd/B25516_14/current/html/docset.html
    Release 12.0.4 Documentation Library
    http://download.oracle.com/docs/cd/B40089_09/current/html/docset.html
    Note: 178722.1 - How to Generate a Specific Form Through AD utility ADADMIN
    https://metalink2.oracle.com/metalink/plsql/ml2_documents.showDocument?p_database_id=NOT&p_id=178722.1
    Regards,
    Hussein

  • I have an error message "page_bottom_overlay-2.png" which comes up when I try to publish.  There is a large X with a Question mark in the middle over the entire background of the page.  The error message says the file is missing.  I did not delete files.

    I have an error message "page_bottom_overlay-2.png" which comes up when I try to publish.  There is a large X with a Question mark in the middle over the entire background of the page.  The error message says the file is missing.  I did not delete files.  How can I find files that seem to be missing?

    This is probably one of the files that is required by the template you are using.
    These files are inside the iWeb app. Control click the iWeb app icon and select "Show package contents".
    You need to dig down through the folders and files to find what you want...
    Contents/Resources/da.lproj/Templates/
    If the file is missing you would need to re install the iWeb app...
    http://www.iwebformusicians.com/iWeb/iWeb-Tips.html

  • Restrating the successfully processed messages------Not Working

    Hi All,
    i have Followed this Blog and Copied that STD program to Z program After that
    Commented those Two mentioned lines in the Report also and activated
    /people/michal.krawczyk2/blog/2005/11/09/xi-restarting-successfully-processed-messages
    While Executing the Report in Se38 by proving the Message ID, iam getting this Error
    Selected message does not exist (any more)
    Regards
    Suman
    Edited by: Suman gupta on May 9, 2008 9:49 AM

    Hey
    >>Selected message does not exist (any more
    This is the issue,you don't have that message anymore hence you can't resend it(it does not matter if its successful or un-successful).
    when you normally try to send the successful message(without changing the ABAP code,you should get a message as below
    "You cannot restart XML message <MessageID> with this status/type"
    try to send another message and see if its successful and then modify the ABAP code and resend that successful message.
    Thanx
    Aamir

  • Virtex6:Configuration data download to FPGA was not successful. DONE did not go high, please check your configuration setup and mode settings

    Hello,everyone.
    I am using virtex6 FPGA and trying to download mcs file to PROM and have failed.
    I download .bit file to FPGA and succeed.
    When i try to download .mcs file to PROM XCF128X-FTG64C(BPI Flash) and choose Slave SelectMAP Mode
    and the process is about 68% it fails.
    The message below the IMapct is as belows:
    done.
    PROGRESS_END - End Operation.
    Elapsed time =      0 sec.
    // *** BATCH CMD : identifyMPM
    // *** BATCH CMD : assignFile -p 1 -file "C:/Users/Administrator/Desktop/TEST/LED/led.bit"
    '1': Loading file 'C:/Users/Administrator/Desktop/TEST/LED/led.bit' ...
    done.
    INFO:iMPACT:2257 - Startup Clock has been changed to 'JtagClk' in the bitstream stored in memory,
    but the original bitstream file remains unchanged.
    UserID read from the bitstream file = 0xFFFFFFFF.
    INFO:iMPACT:501 - '1': Added Device xc6vlx240t successfully.
    INFO:iMPACT - Current time: 2014/3/13 8:48:14
    // *** BATCH CMD : Program -p 1
    PROGRESS_START - Starting Operation.
    Maximum TCK operating frequency for this device chain: 66000000.
    Validating chain...
    Boundary-scan chain validated successfully.
    INFO:iMPACT - 1: Over-temperature condition detected! [ 230.52C >  120.00C]
    1: Device Temperature: Current Reading:  230.52 C, Max. Reading:  230.52 C
    1: VCCINT Supply: Current Reading:   2.997 V, Max. Reading:   2.997 V
    1: VCCAUX Supply: Current Reading:   2.997 V, Max. Reading:   2.997 V
    '1': Programming device...
     Match_cycle = NoWait.
    Match cycle: NoWait
     LCK_cycle = NoWait.
    LCK cycle: NoWait
    done.
    INFO:iMPACT:2219 - Status register values:
    INFO:iMPACT - 0011 1111 0111 1110 0100 1011 1100 0000
    INFO:iMPACT:579 - '1': Completed downloading bit file to device.
    INFO:iMPACT:188 - '1': Programming completed successfully.
     Match_cycle = NoWait.
    Match cycle: NoWait
     LCK_cycle = NoWait.
    LCK cycle: NoWait
    INFO:iMPACT - '1': Checking done pin....done.
    '1': Programmed successfully.
    PROGRESS_END - End Operation.
    Elapsed time =     23 sec.
    Selected part: XCF128X
    // *** BATCH CMD : attachflash -position 1 -bpi "XCF128X"
    // *** BATCH CMD : assignfiletoattachedflash -position 1 -file "C:/Users/Administrator/Desktop/TEST/LED/leda.mcs"
    INFO:iMPACT - Current time: 2014/3/13 8:49:32
    // *** BATCH CMD : Program -p 1 -dataWidth 16 -rs1 NONE -rs0 NONE -bpionly -e -v -loadfpga
    PROGRESS_START - Starting Operation.
    Maximum TCK operating frequency for this device chain: 66000000.
    Validating chain...
    Boundary-scan chain validated successfully.
    INFO:iMPACT - 1: Over-temperature condition detected! [ 230.52C >  120.00C]
    1: Device Temperature: Current Reading:  230.52 C, Max. Reading:  230.52 C
    1: VCCINT Supply: Current Reading:   2.997 V, Max. Reading:   2.997 V
    1: VCCAUX Supply: Current Reading:   2.997 V, Max. Reading:   2.997 V
    '1': BPI access core not detected. BPI access core will be downloaded to the device to enable operations.
    INFO:iMPACT - Downloading core file D:/Xilinx/14.3/ISE_DS/ISE/virtex6/data/xc6vlx240t_jbpi.cor.
    '1': Downloading core...
     Match_cycle = NoWait.
    Match cycle: NoWait
     LCK_cycle = NoWait.
    LCK cycle: NoWait
    done.
    INFO:iMPACT:2219 - Status register values:
    INFO:iMPACT - 0011 1111 0111 1110 0100 1011 1100 0000
    INFO:iMPACT:2492 - '1': Completed downloading core to device.
    Current cable speed is set to 6.000 Mhz.
    Cable speed is default to 3Mhz or lower for BPI operations.
    Current cable speed is set to 3.000 Mhz.
    Setting Flash Control Pins ...
    Setting Configuration Register ...
    Populating BPI common flash interface ...
    Common Flash Interface Information Query completed successfully.
    INFO:iMPACT - Common Flash Interface Information from Device:
    INFO:iMPACT - Verification string:  51 52 59
    INFO:iMPACT - Manufacturer ID:         49
    INFO:iMPACT - Vendor ID:              01
    INFO:iMPACT - Device Code:            18
    Setting Flash Control Pins ...
    Using x16 mode ...
    Setting Flash Control Pins ...
    Setting Configuration Register ...
    '1': Erasing device...
    '1': Start address = 0x00000000, End address = 0x008CE03B.
    done.
    '1': Erasure completed successfully.
    Setting Flash Control Pins ...
    Using x16 mode ...
    Setting Flash Control Pins ...
    Setting Configuration Register ...
    INFO:iMPACT - Using Word Programming.
    '1': Programming Flash.
    done.
    Setting Flash Control Pins ...
    '1': Flash Programming completed successfully.
    Using x16 mode ...
    Setting Flash Control Pins ...
    Setting Configuration Register ...
    '1': Reading device contents...
    done.
    '1': Verification completed.
    Setting Flash Control Pins ...
    Current cable speed is resumed to 6.000 Mhz.
    '1': Configuration data download to FPGA was not successful. DONE did not go high, please check your configuration setup and mode settings.
    `Elapsed time =    814 sec.
    and i find many people have met the same thing. But they are spartan  series FPGA and i try to low the Resistances of Mode pins,M0 M1 and M2, but the problem does not been solved.
    I have read the status Registers and find there is an over-temperature state 
    and in Impact i could not readback the registers. It is strange.
    I am anxious about this problem and have not solved it yet
    What reasons may it be?
    Hope for your answer, thank you

    Hi~I want to know if you solve the configuration problem for virtex-6?
    As I encounter the  same configuration problem, I want to consult  you with some question.
    Can I have your email?
    gszakacs wrote:
    I have measured the VCCINT and find it is 1.0V, not 2.997V;
    That is not at all surprising.  I always assumed the problem is with reading the XADC (system monitor) block and not with the voltage or temperature.
    my Reference board is ML605
    That would have been nice to know at the beginning...
    It seems that you have selected the correct mode, assuming your jumpers are set as required in the ML605 Hardware User's Guide.  See table 1-27, table 1-33 and the note below it about switch S1.
    I'm not that familiar with the details of this reference design, but it may be that the slave SelectMap circuitry requires a reset or power cycle to actually configure the FPGA.  Have you tried power-cycling to see if the FPGA boots from the flash?
    I'd also suggest that you select the V6 in the JTAG chain view, then go to the debug menu of Impact and select Read Device Status (this is from memory, but it's something like that).  That will not only show the bits of the configuration status register, but also describe what each bit means.  Among other things you can check the state of the FPGA's configuration logic and the Mode pins.
     

  • InfoSpoke fails with message "Could not open file on application server"

    BW Experts,
    I created an InfoSpoke that is configured to extract to a flat file. The name of the file is specified using a logical filename. During extraction, the infospoke reports the error message "Could not open file on application server" adnd  marks the extraction process as red(failed). I have tried to run the InfoSpoke in background mode and in dialog mode and the same error appears. After i run in dialog mode, i checked SU53 for authorization errors and did not find any. I also tried changing the Logical filename setup in transaction FILE to a more "friendly" directory in which i'm sure i have authorizations (e.g. my UNIX home directory) and im still getting errors.
    Can you please share your thoughts on this? Any help will greatly appreciated. I also promise to award points.

    Hi Nagesh,
    Thanks for helping out.
    If i configure the InfoSpoke to download to a file using "File Name" option and also check the "Application server" checkbox, the extract works correctly (extraction to the defualt SAP path and filename=infospoke name). If i configure the InfoSpoke to download to the local workstation, the InfoSpoke also works correctly. It's only when i configure it to download to the application server and use the "Logical filename" option, that i encounter a failed extract.
    Here are the messages is the Open Hub Monitor:
    (red icon) Request No.147515
    0 Data Records
    Runtime 1 sec.
    (red icon)Run No. 1
    0 Data Records
    Runtime 1 sec.
    Messages for Run
    Extraction is running RSBO 305
    Could not open file on application server RSBO 214
    Request 147515 was terminated before extraction RSBO 326
    Request 1475151: Error occured RSBO 322
    If i clink on the error message, no messages nor clues are displayed. Note, this is a new InfoSpoke that is currently in the dev system.
    Please help.

  • How to restart the Successfully processed messages

    Hi,
    I have IDOC to File Scenario
    we posted the idoc from R/3 and it has processed successfully.
    Now again i want to process that idoc again with out going to R/3.
    How to restart the Successfully processed message from MONI.
    we have one option in MONI Restart. this is not working for Successfully processed messages.
    How to achieve this
    Regards
    Suman

    Hello Suman..
    XI: Restarting successfully processed messages..
    Go through this : Michal Krawczyk Blog This will really helpful to you..
    /people/michal.krawczyk2/blog/2005/11/09/xi-restarting-successfully-processed-messages
    Reward Points If it is Helpful...
    Thanks,
    Satya Kumar..

  • RAC instance won't start: ORA-00443: background process "VKRM" did not star

    I've logged a SR with Oracle, but while waiting for response from them...I'm stumped I can't find more out here about this article.
    On Oracle knowledgebase...any search for VKRM, gives about the same 3 articles relating to RDA (Remote Diagnostic Assistant).
    Not sure what went on here.
    I have a 5 node RAC cluster. All other instances seem to be running just fine.
    On one instance...some applications were getting an error like:
    ORA-01033: ORACLE initialization or shutdown in progress
    I looked in GRID...and it indicated that only two of the 5 nodes had this instance running...which was strange in that with srvctl, it showed ll 5 up and running:
    [oracle@server2 bin]$ ./srvctl status database -d INSTANCE
    Instance INSTANCE1 is running on node server1
    Instance INSTANCE2 is running on node server2
    Instance INSTANCE3 is running on node server3
    Instance INSTNANCE4 is running on node server4
    Instance INSTANCE5 is running on node server5
    Anyway, thought I'd poke around. I started with trying to get srvctl to stop instance #2...in GRID it seemed that instance 2,4 and 5 weren't working.
    srvctl stop instance -D INSTANCE -i INSTANCE2
    This just hung...
    I thought I'd cycle all the nodes...so, did a ctl-c out of that one, and did:
    [oracle@server2 bin]$ ./srvctl stop database -d INSTANCE -o abort
    PRCD-1124 : Failed to stop database INSTANCE and its services
    PRCR-1065 : Failed to stop resource (((((NAME STARTS_WITH ora.instance.) && (NAME ENDS_WITH .svc)) && (TYPE == ora.service.type)) && ((STATE != OFFLINE) || (TARGET != OFFLINE))) || (((NAME == ora.instance.db) && (TYPE == ora.database.type)) && (STATE != OFFLINE)))
    CRS-2675: Stop of 'ora.instance.db' on 'server5' failed
    CRS-2675: Stop of 'ora.instance.db' on 'server4' failed
    ORA-01034: ORACLE not available
    ORA-27101: shared memory realm does not exist
    Linux-x86_64 Error: 2: No such file or directory
    Process ID: 0
    Session ID: 0 Serial number: 0
    ORA-01034: ORACLE not available
    ORA-27101: shared memory realm does not exist
    Linux-x86_64 Error: 2: No such file or directory
    Process ID: 0
    Session ID: 0 Serial number: 0
    The ORA-01034 messages repeats a number of times...and the one with server4 and server5 repeated again too.
    I also got this:
    CRS-2680: Clean of 'ora.instance.db' on 'server2' failed
    CRS-2675: Stop of 'ora.instance.db' on 'server5' failed
    CRS-2675: Stop of 'ora.instance.db' on 'server4' failed
    ORA-01034: ORACLE not available
    ORA-27101: shared memory realm does not exist
    Linux-x86_64 Error: 2: No such file or directory
    Process ID: 0
    Session ID: 0 Serial number: 0
    I get similar messages when I try to restart.
    clusters seem to be up, and other instances seem to be ok
    Looking at alert log...I found some strangeness in the traces
    Starting background process VKRM
    Errors in file /u01/app/oracle/diag/rdbms/instance/INSTANCE2/trace/INSTANCE2_dbrm_26982.trc:
    ORA-00443: background process "VKRM" did not start
    Errors in file /u01/app/oracle/diag/rdbms/instance/INSTANCE2/trace/INSTANCE2_ora_27467.trc:
    ORA-00450: background process '' did not start
    Errors in file /u01/app/oracle/diag/rdbms/instance/INSTANCE2/trace/INSTANCE2_ora_27467.trc:
    ORA-00450: background process '' did not start
    Error 450 happened during db open, shutting down database
    USER (ospid: 27467): terminating the instance due to error 450
    LGWR waiting for instance termination
    Instance terminated by USER, pid = 27467
    ORA-1092 signalled during: ALTER DATABASE OPEN...
    opiodr aborting process unknown ospid (27467) as a result of ORA-1092
    Looking at the trace listed above:
    2011-05-09 12:17:18.305726 :84271119:db_trace:ksb.c@2157:ksbs1p_real(): [10254:6:464] KSBS1P: process DBRM trying to start background VKRM
    2011-05-09 12:17:18.305729 :8427111A:db_trace:ksb.c@2220:ksbs1p_real(): [10254:6:464] KSBS1P: process DBRM obtained PR enqueue to start background VK
    RM
    2011-05-09 12:17:18.306021 :8427111D:db_trace:ksb.c@2354:ksbs1p_real(): [10254:6:464] KSBS1P: creation error posted OER(1089)
    2011-05-09 12:17:18.306029 :8427111F:db_trace:ksb.c@2424:ksbs1p_real(): [10254:6:464] KSBS1P: out of loop: process did not start
    Trace Bucket Dump End: default bucket for process 6 (osid: 26982, DBRM)
    ORA-00443: background process "VKRM" did not start
    kskdbrmpa: reply error 450
    Any ideas? Again...I can't seem to find much of ANY information searching out there for the VKRM background process not starting...
    Thanks in advance,
    cayenne
    Edited by: cayenne on May 9, 2011 11:34 AM

    Anyone? Anyone? Bueller?
    Ok..have been on phone with Oracle support, and have them stumped so far.
    I've checked..other instances are running (except one other that failed to cleanly shut down with srvctl and same error messages).
    I've check...ASM is running on all 5 nodes. I've used crsctl to check CRS on all nodes..clustering seems ok.
    Memory while somewhat high...should have enough room...the system has never complained before, and this has been up on this config for over a year.
    I was able on node one...to fire up the first nodes instance using the pfile there...it came up. I started it restrict..and promptly ran a datapump export, and then shut back down.
    While Oracle support is going through logs and trace files I sent...I've got another 11Gr2 environment (3 node RAC) I've been using as a test environment...and am recreated the instance there temporarily to allow my developers to test and get past the upcoming deadline.
    But, I'm still puzzled as to the solution on the main cluster. This seem to be normal, except these two instances....
    any ideas on where and what to look for?
    cayenne

  • Process 000004 did not confirm within the permitted time period

    Hi
    The process chain failed while activating the ODS with an error message :Process 000004 did not confirm within the permitted time period" . When repeated the failed step it went successufull. but want to know what can be the cause and steps to be taken in order to avoide this issue further.
    Thanks
    Ratan

    Hi,
    Whenever ODS activation goes there'll be some batch processes you can say as parallel processes running along with main job. Due to unavailability of resources i.e either bkgd or dialog processes soemtimes gets delayed and they gets canceled which leads to the failure of main ODS activation job...
    may be in ur scenario the same thing might have happened, so when you had repeated the step if the resources are free it will be successful.
    once chk in your system for canceled jobs, ther might be some job which relates to your process.
    rgds,

  • Parser Error Message: Could not load file or assembly 'Oracle.DataAccess, V

    I'm working on a 64 bit windows 7 ultimate system and I can't get the Oracle.DataAccess and Oracle.Web to load on the helloworld web page
    See error below. At the very end i have the gacutil output. Also, the same dll's work on a 32 bit windows 7 system. I've also tried to load the beta version of the odac 64 bit
    but it it gets a "java stopped working error"
    Thanks in advance
    WEB PAGE ERRORVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVV
    Server Error in '/test/helloworld' Application.
    Configuration Error
    Description: An error occurred during the processing of a configuration file required to service this request. Please review the specific error details below and modify your configuration file appropriately.
    Parser Error Message: Could not load file or assembly 'Oracle.DataAccess, Version=2.112.1.1, Culture=neutral, PublicKeyToken=89b483f429c47342' or one of its dependencies. The system cannot find the file specified.
    Source Error:
    Line 37:                     <add assembly="System.Xml.Linq, Version=3.5.0.0, Culture=neutral, PublicKeyToken=B77A5C561934E089"/>
    Line 38:                     <add assembly="System.Core, Version=3.5.0.0, Culture=neutral, PublicKeyToken=B77A5C561934E089"/>
    Line 39:                     <add assembly="Oracle.DataAccess, Version=2.112.1.1, Culture=neutral, PublicKeyToken=89B483F429C47342"/>
    Line 40:                     <add assembly="Oracle.Web, Version=2.112.1.1, Culture=neutral, PublicKeyToken=89B483F429C47342"/></assemblies>
    Line 41:           </compilation>
    Source File: C:\inetpub\wwwroot\test\helloworld\web.config Line: 39
    Assembly Load Trace: The following information can be helpful to determine why the assembly 'Oracle.DataAccess, Version=2.112.1.1, Culture=neutral, PublicKeyToken=89b483f429c47342' could not be loaded.
    === Pre-bind state information ===
    LOG: User = IIS APPPOOL\DefaultAppPool
    LOG: DisplayName = Oracle.DataAccess, Version=2.112.1.1, Culture=neutral, PublicKeyToken=89b483f429c47342
    (Fully-specified)
    LOG: Appbase = file:///C:/inetpub/wwwroot/test/helloworld/
    LOG: Initial PrivatePath = C:\inetpub\wwwroot\test\helloworld\bin
    Calling assembly : (Unknown).
    ===
    LOG: This bind starts in default load context.
    LOG: Using application configuration file: C:\inetpub\wwwroot\test\helloworld\web.config
    LOG: Using host configuration file: C:\Windows\Microsoft.NET\Framework64\v2.0.50727\Aspnet.config
    LOG: Using machine configuration file from C:\Windows\Microsoft.NET\Framework64\v2.0.50727\config\machine.config.
    LOG: Post-policy reference: Oracle.DataAccess, Version=2.112.1.1, Culture=neutral, PublicKeyToken=89b483f429c47342
    LOG: Attempting download of new URL file:///C:/Windows/Microsoft.NET/Framework64/v2.0.50727/Temporary ASP.NET Files/test_helloworld/480589f5/895d06ab/Oracle.DataAccess.DLL.
    LOG: Attempting download of new URL file:///C:/Windows/Microsoft.NET/Framework64/v2.0.50727/Temporary ASP.NET Files/test_helloworld/480589f5/895d06ab/Oracle.DataAccess/Oracle.DataAccess.DLL.
    LOG: Attempting download of new URL file:///C:/inetpub/wwwroot/test/helloworld/bin/Oracle.DataAccess.DLL.
    LOG: Attempting download of new URL file:///C:/inetpub/wwwroot/test/helloworld/bin/Oracle.DataAccess/Oracle.DataAccess.DLL.
    LOG: Attempting download of new URL file:///C:/Windows/Microsoft.NET/Framework64/v2.0.50727/Temporary ASP.NET Files/test_helloworld/480589f5/895d06ab/Oracle.DataAccess.EXE.
    LOG: Attempting download of new URL file:///C:/Windows/Microsoft.NET/Framework64/v2.0.50727/Temporary ASP.NET Files/test_helloworld/480589f5/895d06ab/Oracle.DataAccess/Oracle.DataAccess.EXE.
    LOG: Attempting download of new URL file:///C:/inetpub/wwwroot/test/helloworld/bin/Oracle.DataAccess.EXE.
    LOG: Attempting download of new URL file:///C:/inetpub/wwwroot/test/helloworld/bin/Oracle.DataAccess/Oracle.DataAccess.EXE.
    Version Information: Microsoft .NET Framework Version:2.0.50727.4927; ASP.NET Version:2.0.50727.4927
    gacuil output
    VVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVVV
    C:\Users\Administrator>C:\"Program Files"\"Microsoft SDKs"\Windows\v6.0A\Bin\x64
    \gacutil.exe /l Oracle.DataAccess
    Microsoft (R) .NET Global Assembly Cache Utility. Version 3.5.21022.8
    Copyright (c) Microsoft Corporation. All rights reserved.
    The Global Assembly Cache contains the following assemblies:
    Oracle.DataAccess, Version=2.112.1.1, Culture=neutral, PublicKeyToken=89b483f4
    29c47342, processorArchitecture=x86
    Edited by: burk_s on Jun 6, 2010 2:42 PM

    Hi Mubarak,
    Please firstly make sure you installed SharePoint Foundation 2010 with SP2 in a Windows Server 2012 R2. Since only SP2 slipstream installations are supported on Windows Server 2012 R2
    http://blogs.technet.com/b/stefan_gossner/archive/2014/05/03/sharepoint-2010-sp2-and-windows-server-2012-r2.aspx
    http://blogs.technet.com/b/stefan_gossner/archive/2013/09/19/slipstream-version-of-sharepoint-foundation-2010-with-sp2-included.aspx
    Regards,
    Rebecca Tu
    TechNet Community Support
    Please remember to mark the replies as answers if they help, and unmark the answers if they provide no help. If you have feedback for TechNet Support, contact
    [email protected]

  • Error message Could not open file....on application server

    Hi Experts,
    we are using 3.1 production server which has four application servers, after harware upgrdation we are facing connectivity problem with datastage.
    daily the infospkoes and abap programs are faling with the message "Could not open file........on application server".
    when we trigger manually on one server then it gets success, means we are facing problem with other 3 appliction servers. we do not know how to go about this issue.

    Hi,
    This is error RSBO214 and can be due to upper/lower case letters within your destination path.
    Maybe you have changed the path in transaction SE16?
    In case you change the destination manually, you have to make sure that that the directory exists and that the authorizations are set up correctly for the extraction user.
    Rgds,
    Colum

  • Not generate file using ItemAdded Event in SharePoint Online

    I develop a list item event receiver For Sharepoint online.I upload the .wsp file in solution and activate the feature On ItemAdded event I create/generate document on 15 document library based on library template.
    Some time it generate all 15 files and sometime it generate 8/10/12 files.
    i.e not generate files in all the document library.
    It work fine in my local server.
    Please Help me.

    &nbsp;****1.design_Pre_Order_Meeting_Template [=========== ] System.ArgumentException: Value does not fall within the expected range.
    Server stack trace:  
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetWebRelativeUrlFromUrl(String strUrl, Boolean includeQueryString, Boolean canonicalizeUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink._PrivateProcessMessage(IntPtr md, Object[] args, Object server, Object[]& outArgs)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink.SyncProcessMessage(IMessage msg)
    Exception rethrown at [0]:  
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at new_contract_request.pc_contract_request_form.pc_contract_request_form.ItemAdded(SPItemEventProperties properties) ****2.design_Checklist_T [=========== ] System.ArgumentException: Value does not fall within the expected range.
    Server stack trace:  
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetWebRelativeUrlFromUrl(String strUrl, Boolean includeQueryString, Boolean canonicalizeUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink._PrivateProcessMessage(IntPtr md, Object[] args, Object server, Object[]& outArgs)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink.SyncProcessMessage(IMessage msg)
    Exception rethrown at [0]:  
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at new_contract_request.pc_contract_request_form.pc_contract_request_form.ItemAdded(SPItemEventProperties properties) ****3.design_Drawing_Change_Schedule [=========== ] System.ArgumentException: Value does not fall within the
    expected range.
    Server stack trace:  
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetWebRelativeUrlFromUrl(String strUrl, Boolean includeQueryString, Boolean canonicalizeUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink._PrivateProcessMessage(IntPtr md, Object[] args, Object server, Object[]& outArgs)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink.SyncProcessMessage(IMessage msg)
    Exception rethrown at [0]:  
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at new_contract_request.pc_contract_request_form.pc_contract_request_form.ItemAdded(SPItemEventProperties properties) ****4.design_Responsibility_Matrix_Template [=========== ] System.ArgumentException: Value does not fall within
    the expected range.
    Server stack trace:  
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetWebRelativeUrlFromUrl(String strUrl, Boolean includeQueryString, Boolean canonicalizeUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink._PrivateProcessMessage(IntPtr md, Object[] args, Object server, Object[]& outArgs)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink.SyncProcessMessage(IMessage msg)
    Exception rethrown at [0]:  
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at new_contract_request.pc_contract_request_form.pc_contract_request_form.ItemAdded(SPItemEventProperties properties) ****5.design_Review_Record_Template [=========== ] System.ArgumentException: Value does not fall within the expected
    range.
    Server stack trace:  
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetWebRelativeUrlFromUrl(String strUrl, Boolean includeQueryString, Boolean canonicalizeUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink._PrivateProcessMessage(IntPtr md, Object[] args, Object server, Object[]& outArgs)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink.SyncProcessMessage(IMessage msg)
    Exception rethrown at [0]:  
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at new_contract_request.pc_contract_request_form.pc_contract_request_form.ItemAdded(SPItemEventProperties properties) ****6.design_Risk_Assesment_Template [=========== ] System.ArgumentException: Value does not fall within the
    expected range.
    Server stack trace:  
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetWebRelativeUrlFromUrl(String strUrl, Boolean includeQueryString, Boolean canonicalizeUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink._PrivateProcessMessage(IntPtr md, Object[] args, Object server, Object[]& outArgs)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink.SyncProcessMessage(IMessage msg)
    Exception rethrown at [0]:  
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at new_contract_request.pc_contract_request_form.pc_contract_request_form.ItemAdded(SPItemEventProperties properties) ****7.design_Supplier_Material_Sheet [=========== ] System.ArgumentException: Value does not fall within the
    expected range.
    Server stack trace:  
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetWebRelativeUrlFromUrl(String strUrl, Boolean includeQueryString, Boolean canonicalizeUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink._PrivateProcessMessage(IntPtr md, Object[] args, Object server, Object[]& outArgs)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink.SyncProcessMessage(IMessage msg)
    Exception rethrown at [0]:  
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at new_contract_request.pc_contract_request_form.pc_contract_request_form.ItemAdded(SPItemEventProperties properties) ****8.design_Team_Meeting_T [=========== ] System.ArgumentException: Value does not fall within the expected
    range.
    Server stack trace:  
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetWebRelativeUrlFromUrl(String strUrl, Boolean includeQueryString, Boolean canonicalizeUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink._PrivateProcessMessage(IntPtr md, Object[] args, Object server, Object[]& outArgs)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink.SyncProcessMessage(IMessage msg)
    Exception rethrown at [0]:  
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at new_contract_request.pc_contract_request_form.pc_contract_request_form.ItemAdded(SPItemEventProperties properties) ****9.pc_Key_Isssue_Schedule [=========== ] System.ArgumentException: Value does not fall within the expected
    range.
    Server stack trace:  
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetWebRelativeUrlFromUrl(String strUrl, Boolean includeQueryString, Boolean canonicalizeUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink._PrivateProcessMessage(IntPtr md, Object[] args, Object server, Object[]& outArgs)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink.SyncProcessMessage(IMessage msg)
    Exception rethrown at [0]:  
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at new_contract_request.pc_contract_request_form.pc_contract_request_form.ItemAdded(SPItemEventProperties properties) ****10.pc_Client_Progress_Report [=========== ] System.ArgumentException: Value does not fall within the expected
    range.
    Server stack trace:  
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetWebRelativeUrlFromUrl(String strUrl, Boolean includeQueryString, Boolean canonicalizeUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink._PrivateProcessMessage(IntPtr md, Object[] args, Object server, Object[]& outArgs)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink.SyncProcessMessage(IMessage msg)
    Exception rethrown at [0]:  
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at new_contract_request.pc_contract_request_form.pc_contract_request_form.ItemAdded(SPItemEventProperties properties) ****11.pc_Design_Change_Register [=========== ] System.ArgumentException: Value does not fall within the expected
    range.
    Server stack trace:  
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetWebRelativeUrlFromUrl(String strUrl, Boolean includeQueryString, Boolean canonicalizeUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink._PrivateProcessMessage(IntPtr md, Object[] args, Object server, Object[]& outArgs)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink.SyncProcessMessage(IMessage msg)
    Exception rethrown at [0]:  
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at new_contract_request.pc_contract_request_form.pc_contract_request_form.ItemAdded(SPItemEventProperties properties) ****12.pc_rfi_schedule [=========== ] System.ArgumentException: Value does not fall within the expected range.
    Server stack trace:  
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetWebRelativeUrlFromUrl(String strUrl, Boolean includeQueryString, Boolean canonicalizeUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink._PrivateProcessMessage(IntPtr md, Object[] args, Object server, Object[]& outArgs)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink.SyncProcessMessage(IMessage msg)
    Exception rethrown at [0]:  
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at new_contract_request.pc_contract_request_form.pc_contract_request_form.ItemAdded(SPItemEventProperties properties) ****13.pc_Drawing_Progress_Schedule_T [=========== ] System.ArgumentException: Value does not fall within the
    expected range.
    Server stack trace:  
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetWebRelativeUrlFromUrl(String strUrl, Boolean includeQueryString, Boolean canonicalizeUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink._PrivateProcessMessage(IntPtr md, Object[] args, Object server, Object[]& outArgs)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink.SyncProcessMessage(IMessage msg)
    Exception rethrown at [0]:  
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at new_contract_request.pc_contract_request_form.pc_contract_request_form.ItemAdded(SPItemEventProperties properties) ****14.pc_Technical_Submittal_Schedule [=========== ] System.ArgumentException: Value does not fall within the
    expected range.
    Server stack trace:  
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetWebRelativeUrlFromUrl(String strUrl, Boolean includeQueryString, Boolean canonicalizeUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink._PrivateProcessMessage(IntPtr md, Object[] args, Object server, Object[]& outArgs)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink.SyncProcessMessage(IMessage msg)
    Exception rethrown at [0]:  
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at new_contract_request.pc_contract_request_form.pc_contract_request_form.ItemAdded(SPItemEventProperties properties) ****16.pc_Drawing_Issue_Schedule [=========== ] System.ArgumentException: Value does not fall within the expected
    range.
    Server stack trace:  
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetWebRelativeUrlFromUrl(String strUrl, Boolean includeQueryString, Boolean canonicalizeUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink._PrivateProcessMessage(IntPtr md, Object[] args, Object server, Object[]& outArgs)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink.SyncProcessMessage(IMessage msg)
    Exception rethrown at [0]:  
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at new_contract_request.pc_contract_request_form.pc_contract_request_form.ItemAdded(SPItemEventProperties properties) ****19.proc_Pre_Order_Meeting_T [=========== ] System.ArgumentException: Value does not fall within the expected
    range.
    Server stack trace:  
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetWebRelativeUrlFromUrl(String strUrl, Boolean includeQueryString, Boolean canonicalizeUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink._PrivateProcessMessage(IntPtr md, Object[] args, Object server, Object[]& outArgs)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink.SyncProcessMessage(IMessage msg)
    Exception rethrown at [0]:  
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at new_contract_request.pc_contract_request_form.pc_contract_request_form.ItemAdded(SPItemEventProperties properties) ****20.proc_Preferred_Supplier_List [=========== ] System.ArgumentException: Value does not fall within the expected
    range.
    Server stack trace:  
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetWebRelativeUrlFromUrl(String strUrl, Boolean includeQueryString, Boolean canonicalizeUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink._PrivateProcessMessage(IntPtr md, Object[] args, Object server, Object[]& outArgs)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Messaging.StackBuilderSink.SyncProcessMessage(IMessage msg)
    Exception rethrown at [0]:  
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.HandleReturnMessage(IMessage reqMsg, IMessage retMsg)
    &nbsp;&nbsp;&nbsp;at System.Runtime.Remoting.Proxies.RealProxy.PrivateInvoke(MessageData& msgData, Int32 type)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb_SubsetProxy.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile__Inner(String strUrl)
    &nbsp;&nbsp;&nbsp;at Microsoft.SharePoint.SPWeb.GetFile(String strUrl)
    &nbsp;&nbsp;&nbsp;at new_contract_request.pc_contract_request_form.pc_contract_request_form.ItemAdded(SPItemEventProperties properties)

  • Xerox Phaser 4500 : "remote host did not accept file (32)"

    Am trying to print to our networked Xerox Phaser 4500DT at work. Set it up as an LPR printer as I did with Tiger (setting it up as IPP gives a permission denied error when you try to print), and printed a test page. Worked fine.
    Try to print any sort of useful document, however, and I get a "remote host did not accept file (32)" error, when it's spooled about 20% of the document. Anybody run into this, or have any ideas?
    I've tried Leopard's built-in 4500 driver, and the Leopard driver from the Xerox website (which seems to be the same version anyway). I've also tried the trick of putting "lp" in the queue name field, which seems to have been the cause of this error for some people. No joy for me, though.

    That seems to be an LPD error message, so you could try setting the printer up as either IPP or JetDirect, if the interface supports either one.

  • V5 in BPI Mode " Configuration data download to FPGA was not successful. DONE did not go high,"

    Hello,everyone.
    I am using virtex5 XC5VLX155 FPGA and trying to download mcs file to BPI flash and have failed.
    The flash is JS28F512P30E. The iMpact version is 14.7. 
    FPGA's VCCINT is 1.0V, VCCAUX is 2.5V. VCCO is 3.3V.
    M[2:0] is 010 in Master BPI.  Ican  program FPGA through JTAG. The FPGA_DONE pin 's  LED can always flash.
    The error is shown as below. the full  IMPACT console log and the SCHEMATIC_ FLASH are in the attachment.
    Using x16 mode ...
    Setting Flash Control Pins ...
    '1': Erasing device...
    '1': Start address = 0x00000000, End address = 0x004E4AFF.
    done.
    '1': Erasure completed successfully.
    Using x16 mode ...
    Setting Flash Control Pins ...
    INFO:iMPACT - Using Word Programming.
    '1': Programming Flash.
    done.
    '1': Flash Programming completed successfully.
    '1': Configuration data download to FPGA was not successful. DONE did not go high, please check your configuration setup and mode settings.
    PROGRESS_END - End Operation.
    Elapsed time =    692 sec.
    Hope everyone give more advices. Thank you.
     

    Thank you very much!
    I can read ack the mcs file, but the file is much bigger than the original mcs file.
    The flash datasheet is in the attachment.
    I want to use the Master BPI mode. In BPI_UP, the address starts at 0 and increments by 1 until the DONE pin is
    asserted. I do not know the difference between the BPI_UP and BPI_DOWN.
    ps:  The R61,R62 and R63 are not weld on the board. The ADV pin is tie to VSS .
     