Sun Storedge 3310

I would like to know if it is possible to connect a sun storedge 3310 array to windows server 2012 r2? If ther is could you tell me how. I know how to do it on server 2003 but 2012 r2 is much different.

Hi,
I would like to know if it is possible to connect a sun storedge 3310 array to windows server 2012 r2?
Since we are not familiar with the product you have mentioned, I would suggest you contact corresponding vendor support to get more specific and accurate response.
Thank you for your understanding and support.
Best Regards,
Amy
Please remember to mark the replies as answers if they help and un-mark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact [email protected]

Similar Messages

  • Veritas Volume manager 4.0 with Sun StorEdge 3310 D

    I am running into a problem. The vxconfigd deamon always dump core when rebooting.
    Our environment is listed below.
    OS environemt.
         SunOS server1 5.8 Generic_117350-43 sun4u sparc SUNW,Sun-Fire-V240
    Software installed.
         Sun Cluster 3.0
         Veritas Volume Manager 4.0 MP2.
    Disk Array associated.
         Sun StorEdge 3310 D.
    I looked up veritas.com and find Array Support Library (ASL) for Sun StorEdge 3xxx Series is recommended. But I didn't find this library is running on this server.
    Please refer to this following link
    http://support.veritas.com/docs/277923
    As our system is one of critical systems and I'd like to confirm that I can follow up this procedure without doing harm things to our system.
    Jeff

    No problem Jeff :)
    I took a look at the Veritas doc and you're right it does seem to cover everthing.
    Has the vxconfigd core dumped since the start? ie from the moment it was installed?
    I have installed VXVM 4.0 with Solaris 8 but without the ASL and this worked ok, I know that's not much help to you but I am not sure the ASL will help. Mind you I have not installed it with Sun Cluster 3.0.

  • Connecting to a Sun StorEdge 3310

    Hello all,
    in our warehouse I've found a Sun StorEdge 3310. I want to try to use it but I do not have any kind of usefull serial cable. Also StorEdge has a LAN port but I'm not able to find a mac address to force ARP table and telnet it.
    Any hint to get my storage accessible?
    Thanks
    Stefano
    http://www.stefanocislaghi.it

    Please have a look at the installation document http://docs.sun.com/app/docs/doc/816-7290-19 and feel free to get back here if you still have questions.

  • Sun storedge 3310 fw 4.1.5f MIB ?

    Hi does anybody know where can I find the MIB snmp file for Sun storedge 3310 fw version 4.1.5.f ?
    Thanks

    Nevermind the last posts, I forgot to install the 32 bit drivers of ultra 3 card.
    Anyway thanks to anyone who might have thought about this.
    Orlando

  • Multi-initated LUNS on Sun StorEdge 3310

    I recently received two Sun V20Zs and a StorEdge 3310, and I am asked to cluster these two machines with the 3310 as shared storage. 3310 came with two raid controllers.
    My question is, could I create multi-initiaged LUNs and have these LUNs mapped by the V20Z. Reason behind having the multi-imitated LUNs is it will facilitate fail-over in case a one of the V20Z are unavailable.
    V20Zs are running Fedora Core 3.
    Thanks for your help.

    A good output that would give you a hint of a problem is iostat -En
    This output reports anykind of errors to a particular disk since the last reboot. If you are seeing high error numbers, then you can move onto running a file system check - fsck - on the drive.
    If you have anykind of RAID setup, check to see if any issues are being reported. Depending on what you are using to manage the RAID - Veritas Volume Manager or Solaris Disk Suite - they will most certainly tell you if there is an issue. A vxprint for Veritas and a metastat for DiskSuite will show you what you have setup and if there are any recognized disk issues.

  • Disk error message on Sun StorEdge 3310.

    Hi guys,
    Does anyone see the following error message in the /var/adm/messages? Should I have to replace this faulty disk?
    Mar 6 11:06:21 balrog scsi: [ID 107833 kern.warning] WARNING: /pci@1d,700000/sc
    si@1/sd@5,0 (sd36):Mar 6 11:06:21 balrog Error for Command: write(10) Error Level:Retryable
    Mar 6 11:06:21 balrog scsi: [ID 107833 kern.notice] Requested Block: 5491072 Error Block: 5491079
    Mar 6 11:06:21 balrog scsi: [ID 107833 kern.notice] Vendor: SEAGATE
    Serial Number: 0447B9LRDV
    Mar 6 11:06:21 balrog scsi: [ID 107833 kern.notice] Sense Key: Hardware Error
    Mar 6 11:06:21 balrog scsi: [ID 107833 kern.notice] ASC: 0x32 (no defect spare location available), ASCQ: 0x0, FRU: 0x4
    Looking forward to your comments.
    Jeff.

    A good output that would give you a hint of a problem is iostat -En
    This output reports anykind of errors to a particular disk since the last reboot. If you are seeing high error numbers, then you can move onto running a file system check - fsck - on the drive.
    If you have anykind of RAID setup, check to see if any issues are being reported. Depending on what you are using to manage the RAID - Veritas Volume Manager or Solaris Disk Suite - they will most certainly tell you if there is an issue. A vxprint for Veritas and a metastat for DiskSuite will show you what you have setup and if there are any recognized disk issues.

  • Storedge 3310 and format

    hi,
    i have the following problem:
    a storedge 3310 with raid controller. i have partitioned the volume ( which consists of 6 raid 1 logical drives) into 4 partions and assigned luns to these partitions.
    probe-scsi-all shows the following:
    /pci@1e,600000/pci@2/scsi@4
    Target 0
    Unit 0 Disk SUN StorEdge 3310 0325
    Unit 1 Disk SUN StorEdge 3310 0325
    Unit 2 Disk SUN StorEdge 3310 0325
    Unit 3 Disk SUN StorEdge 3310 0325
    format shows only the first one:
    0. c0t0d0
    /pci@1c,600000/scsi@2/sd@0,0
    1. c0t1d0
    /pci@1c,600000/scsi@2/sd@1,0
    2. c2t0d0
    /pci@1e,600000/pci@2/scsi@4/sd@0,0
    where are the other three partitions?

    Hi there,
    I have a similar situation where I set up a SE 3310 connected to a Sunfire V210 running Solaris 10 GA.
    The SE 3310 was set up as 2 RAID 5 logical volumes, each
    with 5x72GB disk drives. I also map the hosts LUNS etc...
    At the V210, when I did the probe-scsi-all it sees both RAID5
    logical disks as StorEdge 3310 0325 (firmware 3.25)
    however when I boot up with the -rv option, it only sees one
    RAID5. Where is the other RAID 5 logical drive?
    I did update_drv -f sd, devfsadm; manually edit the sd.conf
    to add additional controllers and LUN's (c0,c1,c2 and up to
    32 LUN's for each controller, but I still do not see the other
    RAID5 logical drive. Where is it?
    Please help !!!
    Tony

  • Partition logical drive storedge 3310

    Hi
    I have Sun storedge 3310 version 413B, i create logical drive in Raid 5 configuration:
    LD LD-ID Size Assigned Type Disks Spare Failed Status
    ld0 68EB1906 272.46GB Primary RAID5 5 1 0 Good
    and i need create 16 partitions on it, but i can create only 7 partitions:
    * partitions
    LD/LV ID-Partition Size
    ld0-00 68EB1906-00 14.00GB
    ld0-01 68EB1906-01 14.00GB
    ld0-02 68EB1906-02 14.00GB
    ld0-03 68EB1906-03 14.00GB
    ld0-04 68EB1906-04 14.00GB
    ld0-05 68EB1906-05 14.00GB
    ld0-06 68EB1906-06 14.00GB
    ld0-07 68EB1906-07 14.00GB
    How i can create other eight partitions on ld0; i need create this configuration:
    ld0-00 68EB1906-00 14.00GB
    ld0-01 68EB1906-01 14.00GB
    ld0-02 68EB1906-02 14.00GB
    ld0-03 68EB1906-03 14.00GB
    ld0-04 68EB1906-04 14.00GB
    ld0-05 68EB1906-05 14.00GB
    ld0-06 68EB1906-06 14.00GB
    ld0-07 68EB1906-07 14.00GB
    ld0-08 68EB1906-08 14.00GB
    ld0-09 68EB1906-09 14.00GB
    ld0-0a 68EB1906-0A 14.00GB
    ld0-0b 68EB1906-0B 14.00GB
    ld0-0c 68EB1906-0C 20.00GB
    ld0-0d 68EB1906-0D 20.00GB
    ld0-0e 68EB1906-0E 20.00GB
    ld0-0f 68EB1906-0F 20.00GB
    ld0-10 68EB1906-10 24.46GB
    any idea?....thanks

    If you are using lun mapping to create your partitions, (done by using telnet to the array and then selecting "View and Edit Host Luns") you have to tell the array the maximum numbers of luns you can create. Some systems will only let you create one by default and you can't make any changes to the size of the lun you are trying to present to your host. There is an option when you telnet to the box in the controller area for the maximum number of luns you can create. Luns in this case are partitions.
    If you are not trying to partition your logical drive by using lun mapping, I don't know what your problem is.
    Stephen

  • Sun StorEdge[TM] 3510/3310/3511

    Dear
    What does the "2(3)" mean in the show disks output under the channel ID (Ch) for Sun StorEdge[TM] 3310/3510/3511
    :)Thanks
    Mohammed Tanvir

    Hi
    2(3) means there are two channels configured for the storedge 2 and 3 or I should say that it is in redundant mode. And at present control is with 2nd channel.
    Regards

  • Sun storedge se 3310

    Hello all,
    I have created on a sun storedge se 3310 an RAID 5 array matrix with 4 disks (73 GB) for logical drive and a 5th disk (73 GB) for local spare. It seems that is taking a long time to be created and i can not see any activity on the servers leds.
    Can anyone tell me how long it should take until the array will be finished?
    Thanks

    For SE3310 RAID 5 with 4HDD(73GB) you have to wait for about 1.5hrs to 2hrs. new LD be completely initialized, then after that you can perform lun mapping.

  • Not all storedge 3310 disk showing up

    I have a storedge 3310 hooked to my V440 running solaris 8 and not all the logical disks are showing up in the format command. I have a total of 4 logical disks configured on the array, two on the primary controller and 2 on the secondary controller. It appears that I only have one logical drive from each controller appearing. Any help would be appreciated.
    Thanks

    That worked however, now when I run format I get the following errors:
    8. c4t1d1 <SUN-StorEdge3310-0325 cyl 34474 alt 2 hd 64 sec 32>
    /pci&#64;1d,700000/scsi&#64;1/sd&#64;1,1
    9. c4t1d3 <SUN-StorEdge3310-0325 cyl 34474 alt 2 hd 64 sec 32>
    /pci&#64;1d,700000/scsi&#64;1/sd&#64;1,3
    Specify disk (enter its number): Feb 21 18:10:44 socorro scsi: Vendor 'SUN', product 'StorEdge', 70606848 512 byte blocks
    Feb 21 18:10:44 socorro scsi: WARNING: /pci&#64;1c,600000/scsi&#64;1/sd&#64;0,2 (sd160):
    Feb 21 18:10:44 socorro corrupt label - wrong magic number
    Feb 21 18:10:44 socorro scsi: Vendor 'SUN', product 'StorEdge', 70606848 512 byte blocks
    Feb 21 18:10:44 socorro scsi: WARNING: /pci&#64;1d,700000/scsi&#64;1/sd&#64;1,1 (sd204):
    Feb 21 18:10:44 socorro corrupt label - wrong magic number
    Feb 21 18:10:44 socorro scsi: Vendor 'SUN', product 'StorEdge', 70606848 512 byte blocks
    Will look into thme and see if I can get them resolved.
    Thanks

  • StorEdge 3310 RAID hung.

    During the billing run on a Sun Fire V440, the attached 3310 hung. Reboots of the server did nothing to improve the situation, but once the RAID was powercycled everything was alright again.
    sccli version 2.1.1
    built 2005.09.16.23.10
    build 1 for solaris-sparc
    Vendor: SUN
    Product: StorEdge 3310
    Revision: 0325
    Peripheral Device Type: 0x0
    NVRAM Defaults: 325S 3310 v1.37
    Bootrecord version: 1.31G
    Serial Number: 07CB61
    There are no "event" entries for this trouble listed in sscli, and everything comes up green. The only errors we received at the time were that of SCSI errors:
    Aug 10 10:49:30 InfranetDB01 scsi: [ID 107833 kern.warning] WARNING: /pci@1f,700
    000/scsi@2,1/sd@0,0 (sd16):
    Aug 10 10:49:30 InfranetDB01 Error for Command: write(10) Error
    Level: Retryable
    Aug 10 10:49:30 InfranetDB01 scsi: [ID 107833 kern.notice] Requested Block:
    289557696 Error Block: 289557696
    Aug 10 10:49:30 InfranetDB01 scsi: [ID 107833 kern.notice] Vendor: SUN
    Serial Number: 29C8306F-00
    Aug 10 10:49:30 InfranetDB01 scsi: [ID 107833 kern.notice] Sense Key: Unit
    Attention
    Aug 10 10:49:30 InfranetDB01 scsi: [ID 107833 kern.notice] ASC: 0x29 (power
    on, reset, or bus reset occurred), ASCQ: 0x0, FRU: 0x0
    Aug 10 11:01:12 InfranetDB01 scsi: [ID 107833 kern.notice] /pci@1f,700000/scsi@2
    ,1 (mpt1):
    Aug 10 11:01:12 InfranetDB01 got external SCSI bus reset.
    Aug 10 11:01:12 InfranetDB01 scsi: [ID 365881 kern.info] /pci@1f,700000/scsi@2,1
    (mpt1):
    Aug 10 11:01:12 InfranetDB01 Log info 11030000 received for target 0.
    Aug 10 11:01:12 InfranetDB01 scsi_status=0, ioc_status=804b, scsi_state=8
    Aug 10 11:01:12 InfranetDB01 scsi: [ID 107833 kern.notice] /pci@1f,700000/scsi@2
    ,1 (mpt1):
    Aug 10 11:01:12 InfranetDB01 got external SCSI bus reset.
    [repeat]
    The question is whether or not to upgrade the firmware. Since the current firmware is so old (version 3.x) there seems to be special instructions to bring it to 4.x, and eventually 4.15G. Which would include OS patches as well. (117171-12).
    Or, just carry on, since this has only happened once (during the last billing run) in the last 9 runs/months.

    What is the difference between the host/drive channel? Besides the fact that they are their for connecting to disk drive or to host. Because lets say I connect the first RAID controller to the second one, host-to-host configuration from one RAID to another, will the host see this transparently?
    By the way, I tried the JBOD method you mention so basically just connect one of the RAID unit to the other one just as a JBOD and the RAID controller can see the disks on a difference channel but only half of the disk because the RAID I/O actually have internal conneciton to half of the disk, while the other half is jumper.

  • Partition Storedge 3310

    Hello All,
    My first connection on this forum & I would need your help.
    I have to configure a Storedge 3310 (6 disks 72Gb).
    Already created:
    1 Logical Drive: 5 disks in Raid 5 + 1 Spare
    Size of the drive: 279GB.
    I need to create 11 partitions (10*12GB + 1*159GB), but apparently, I can create only 8 partitions (from 0 to 7).
    Could you help me? I don't know how to do.
    I already read this topic: http://forum.java.sun.com/thread.jspa?forumID=831&threadID=5098175
    But the answer is not really clear (for me...)
    Thx.
    Eric
    Message was edited by:
    Eric_MdZ

    I had to do something similar on site today, I believe (although have not tried it) that you alter the number of partitions to create on the 3320, however an alternative way of partitioning the Logical Drive is to let Solaris do it, by that I mean LVM ( formly known as disksuite). Bring the logical drive into solaris and create one large partition. Bring that single partition into LVM and then use "soft partitioning" to break it up. I have done this before and it works fine, its just another way of doing the same job albeit on the host and not on the Array.

  • Storedge 3310 & Dual Ultra3 Adaptor

    Hi all,
    A couple of things...
    1. We have 2 storedge 3310 and two machines with Ultra3 Adaptors. I can not see the 3310 using the Ultra3 adaptors. If I plug the 3310 into the host controller I can see it, (but that is not ideal as it is running slow). at the 'ok' prompt I can see the 3310, but I can never get anything to display in 'format' or on the ssconsole.
    commands tried:
    reboot -- -r
    update_drv -f sd
    devfsadm -v
    All with no luck. Any ideas?
    2. With the 3310 I have configure one logical RAID 5 drive (5 disks) and partitioned into 4 and mapped each partition to a host lun.
    I have mucked with /kernel/drv/sd.conf and put "set scsi_options=0x43ff8" into /etc/system, I can never see the anything but the first partion on the first lun.
    Help please :-)

    Have you downloaded and installed the Ultra3 SUNWqus....packages & installed patch as in the release notes or InfoDoc 47841?
    http://sunsolve.Sun.COM/data/816/816-2157/pdf/816-2157-14.pdf
    http://sunsolve.Sun.COM/pub-cgi/retrieve.pl?doc=finfodoc%2F47841&zone_110=47841

  • Password on storedge 3310

    I have a old storedge 3310. There is a password on there that I do not have. I'm running ubuntu 14.04 on the server. I do not have any software the came with storedge 3310. So how do go about change the password? I know that if I had all the sun software this would not be a problem but, I have not been able to find any. I'm using a serial cable to connect the 2 servers together.
    Thanks

    Do you know the current password on the 6120?
    If not, then I'm afraid you'll need a service engineer and downtime on the array to change it.
    If you do know it, then you just telnet to the 6120; log in with the username 'root' and the current password and then issue the 'passwd' command.
    HTH,
    --A.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           

Maybe you are looking for

  • Deleting Loops

    May someone please tell me how to delete the loops in Garageband that came with Soundtrack Pro? The the thing is, I uninstalled Soundtrack pro and it's loops. But Garageband still has SP's loops in the loop browser, but the loops are gone. Poof! Not

  • Multitimbral Instrument Plugins (ie 1 instument many midi channels)

    I am using SampleTank and Kontakt and they way I use them just does not seem right ! The problem starts here.. - when I add Kontakt to a Instrument Strip the Midi channel is assigned in the strip in the environment window. - If I create multiple trac

  • Monitoring EP through SMD

    Hi Friends, We have installed Willy introscope and Configured SMD for EP system. Working fine.. we can able to monitor the EP System, Java System through SMD. Now, I need to know , what are the Theshold Values for 1. EP response time, CPU utilization

  • Duplicate the details section when I retrieve data from Delivery notes

    Hey all. I built a query that retrieve data from ODLN and it works fine. But, when I have a Delivery Notes Document that has items from some different orders (that I copy them to Delivery notes of course) it duplicate my rows in the report I run the

  • Problem while executing SAP transactions

    Dear All,        When I am executing transaction like ME21N, ME51N its going to ABAP runtime error.Below is the runtime error description will you please go through it. <b>Type group was changed at runtime.</b> <u> What happened?</u> Error in ABAP ap