Sun StorEdge L8 Tape Library (UREGENT!!)

hi all
help needed.. i am new in this.. i ahve to do backup in the Sun StorEdge L8 every weekend.. as usual i will unload the Tape 1 and load the Tape 2 for this weekend backup.. Recently the tape shows '!' at the Tape 2.. when i try to unload the Tape 2, it shows me no tape is load.. wat does the '!' means?? can anyone explain? is it the tape is bad??
this is wat it shows when i mt staus
HP Ultrium LTO 2 tape drive:
sense key(0x6)= Unit Attention residual= 0 retries= 0
file no= 0 block no= 0
can anyone explain..
Thanks..

Hi Surajsid
Do you still have a support contract for this Library ? If it's still showing the same issues after power cycling the drive I would log a call with Orcale/Sun.
Have you changed anything in your backup environment lately ?
Regards
David

Similar Messages

  • Installing Sun Storage C4 - Tape Library on IBM p550Q

    All,
    Need your advise, what should we prepare to install Sun Storage C4 Tape Library attached to IBM P550Q?
    I read the information about supported OS on C4 Tape Library are only Windows, Linux and Solaris. So, how do we reveal with this situation?
    regards,
    /hendra

    I'm looking for the same thing -
    Were you able to location any documentation?
    I've been trying to get my hands on the documentation
    for the C4. Sun's doc site does not have this product
    listed at all. The product documentation link
    (http://docs.sun.com/app/docs/prod/1878#hic) just
    returns " The requested item could not be found."
    I've even tried opening up a case with Sun. First,
    the support people had no idea what the C4 was. After
    3 days and 3 support engineers, I finally found one
    who understood what this product was, but I was then
    told that getting the documentation would be on a
    time and materials basis. I'd rather not have to pay
    $400+ for documentation that should be on their
    website, just like all their other equipment. I'm
    currently using the Quantum PX502 documentation as a
    reference, but I'd really like to see Sun specific
    documentation.
    Any ideas?
    Thanks.I'm looking for the same thing -
    Were you able to location any documentation?

  • Sun Storedge L9 command utility, need to load and unload tapes.

    I am looking for a utility that will unload, and reload an L9 Sun storedge.
    I found:
    http://www.sun.com/bigadmin/jsp/descFile.jsp?url=descAll/l9ctl
    This utility has some calls that either we don't have, or I can't find:
    loadmedia.cgi
    inloadmedia.cgi
    Am I setting this up incorrectly?
    Where is this stuff supposed to be?
    I am running on a sun ulta-5, Solaris 8.

    Hello!
    Before use, You should small customize script:
    1) Change
    $LibraryHostName="http://l9"; - It's library hostname.
    Or set this name in /etc/hosts
    $AdminPwd="12341234"; - password to Library
    And, of course, before use this script - you should setup netwotk connection of L9.
    Another way - use project MTX.
    http://freshmeat.net/projects/mtx/releases
    This program use SCSI commands for control library.
    Regards.

  • Solstice backup 6.1 hang when invoking the autochanger "SUN Storedge L8 "

    My company have a SUN Storedge L8 attached to a SUN Solaris 9 (SPARC) while I can only do a tar to the /dev/rmt/0, whenever I tried to interact with the jukebox with the solstice backup, the program hang definitely.
    grep '/usr/kernel/drv/lus' /var/sadm/install/contents
    /usr/kernel/drv/lus f none 0555 root bin 34624 12073 993189557 SUNWsbus2
    /usr/kernel/drv/lus.conf f none 0444 root bin 3754 45438 993190441 SUNWsbus2
    /usr/kernel/drv/lus32 f none 0555 root bin 33444 4422 993213667 SUNWsbus2
    pkginfo -l SUNWsbus2
    PKGINST: SUNWsbus2
    NAME: Solstice Backup (Backup/Recover) Device Drivers
    CATEGORY: system
    ARCH: sparc
    VERSION: 6.1,REV=Build.186
    BASEDIR: /
    VENDOR: Sun Microsystems, Inc.
    PSTAMP: gelato010622054128
    INSTDATE: Apr 08 2003 13:25
    STATUS: completely installed
    FILES: 48 installed pathnames
    44 executables
    37896 blocks used (approx)
    this machine has installed the solstice backup manager
    pkginfo | grep -i Solstice
    system SUNWmibii Solstice Enterprise Agents 1.0.3 SNMP daemon
    system SUNWsacom Solstice Enterprise Agents 1.0.3 files for root file system
    system SUNWsadmi Solstice Enterprise Agents 1.0.3 Desktop Management Interface
    system SUNWsadml Solstice Launcher.
    system SUNWsadmx Solstice Enterprise Agents 1.0.3 Desktop Management Interface Libraries (64-bit)
    system SUNWsasnm Solstice Enterprise Agents 1.0.3 Simple Network Management Protocol
    system SUNWsasnx Solstice Enterprise Agents 1.0.3 Simple Network Management Protocol Libraries (64-bit)
    application SUNWsbuc Solstice Backup (Backup/Recover) Client
    application SUNWsbum Solstice Backup (Backup/Recover) Man
    application SUNWsbun Solstice Backup (Backup/Recover) Storage Node
    application SUNWsbus1 Solstice Backup (Backup/Recover) Server
    system SUNWsbus2 Solstice Backup (Backup/Recover) Device Drivers
    under the server->registration, I found that the registration contains :-
    Autochanger Module, 9 slots/9
    ClientPaks for Windows/1
    Networker for UNIX, Workgroup edition (8 clients per server)1 server
    Networker Module for Oracl/1
    BTW, inquire shows:-
    /etc/LGTOuscsi/inquire
    [email protected]:TOSHIBA DVD-ROM SD-M14011009|CD-ROM
    [email protected]:ADIC FastStor 2 A12r|Autochanger (Jukebox)
    [email protected]:HP Ultrium 1-SCSI E3 |Tape
    [email protected]:HP Ultrium 1-SCSI E3 |Tape
    where cfgadm -alv shows:-
    Ap_Id Receptacle Occupant Condition Information
    When Type Busy Phys_Id
    c0 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,700000/scsi@6:scsi
    c0::/dev/lus connected configured unknown TOSHIBA DVD-ROM SD-M1401
    unavailable CD-ROM n /devices/pci@8,700000/scsi@6:scsi::/dev/lus
    c0::dsk/c0t6d0 connected configured unknown TOSHIBA DVD-ROM SD-M1401
    unavailable CD-ROM y /devices/pci@8,700000/scsi@6:scsi::dsk/c0t6d0
    c1 connected configured unknown
    unavailable fc-private n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc
    c1::21000004cfe34092 connected configured unknown SEAGATE ST373307FSUN72G
    unavailable disk n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc::21000004cfe34092
    c1::21000004cfe34350 connected configured unknown SEAGATE ST373307FSUN72G
    unavailable disk n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc::21000004cfe34350
    c2 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,700000/scsi@6,1:scsi
    c2::lus1 connected configured unknown
    unavailable unknown n /devices/pci@8,700000/scsi@6,1:scsi::lus1
    c3 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@4:scsi
    c3::lus2 connected configured unknown HP Ultrium 1-SCSI
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@4:scsi::lus2
    c3::rmt/0 connected configured unknown HP Ultrium 1-SCSI
    unavailable tape n /devices/pci@8,600000/pci@1/scsi@4:scsi::rmt/0
    c4 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@5:scsi
    c4::lus3 connected configured unknown
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@5:scsi::lus3
    usb0/1 connected configured ok Mfg: <undef> Product: <undef> NConfigs: 1 Config: 0 <no cfg str descr>
    unavailable usb-kbd n /devices/pci@8,700000/usb@5,3:1
    usb0/2 empty unconfigured ok
    unavailable unknown n /devices/pci@8,700000/usb@5,3:2
    usb0/3 connected configured ok Mfg: <undef> Product: <undef> NConfigs: 1 Config: 0 <no cfg str descr>
    unavailable usb-mouse n /devices/pci@8,700000/usb@5,3:3
    usb0/4 empty unconfigured ok
    unavailable unknown n /devices/pci@8,700000/usb@5,3:4
    nsrjb shows
    Jukebox L8:
    slot volume pool volume id recyclable
    1: dwbak.inc.day0.wk0.001* 2481680129
    2: dwbak.inc.day0.wk0.002 DW Incremental 2481704705 no
    3: dwbak.inc.day0.wk0.003 DW Incremental 2481729793 no
    4: -* -
    5: dwbak.inc.day0.wk0.005 DW Incremental 2481779201 no
    6: dwbak.inc.day0.wk0.006 DW Incremental 2481804289 no
    7: dwbak.inc.day0.wk0.007 DW Incremental 2481829889 no
    8: dwbak.inc.day0.wk0.008 DW Incremental 2481854209 no
    *not registered in the NetWorker media data base
    drive 1 (/dev/rmt/0cbn) slot 5: dwbak.inc.day0.wk0.005
    nsrjb -HE hang indefinitly, so does nsrjb -HHE. devfsadm -c tape also hang while simply devfsadm can run without problem and cfgadm -alv c3 provide the following:-
    Ap_Id Receptacle Occupant Condition Information
    When Type Busy Phys_Id
    c3 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@4:scsi
    c3::lus2 connected configured unknown HP Ultrium 1-SCSI
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@4:scsi::lus2
    c3::rmt/0 connected configured unknown HP Ultrium 1-SCSI
    unavailable tape n /devices/pci@8,600000/pci@1/scsi@4:scsi::rmt/0
    nsjrb result should be past history, coz I am doing tar and manually changing the slot for quite some time already. Now I unconnect the cable and run devfsadm and then cfgadm -alv shows
    cfgadm -alv
    Ap_Id Receptacle Occupant Condition Information
    When Type Busy Phys_Id
    c0 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,700000/scsi@6:scsi
    c0::/dev/lus connected configured unknown TOSHIBA DVD-ROM SD-M1401
    unavailable CD-ROM n /devices/pci@8,700000/scsi@6:scsi::/dev/lus
    c0::dsk/c0t6d0 connected configured unknown TOSHIBA DVD-ROM SD-M1401
    unavailable CD-ROM y /devices/pci@8,700000/scsi@6:scsi::dsk/c0t6d0
    c1 connected configured unknown
    unavailable fc-private n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc
    c1::21000004cfe34092 connected configured unknown SEAGATE ST373307FSUN72G
    unavailable disk n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc::21000004cfe34092
    c1::21000004cfe34350 connected configured unknown SEAGATE ST373307FSUN72G
    unavailable disk n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc::21000004cfe34350
    c2 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,700000/scsi@6,1:scsi
    c2::lus1 connected configured unknown
    unavailable unknown n /devices/pci@8,700000/scsi@6,1:scsi::lus1
    c3 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@4:scsi
    c3::lus2 connected configured unknown HP Ultrium 1-SCSI
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@4:scsi::lus2
    c3::rmt/0 connected configured unknown HP Ultrium 1-SCSI
    unavailable tape n /devices/pci@8,600000/pci@1/scsi@4:scsi::rmt/0
    c4 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@5:scsi
    c4::lus3 connected configured unknown
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@5:scsi::lus3
    usb0/1 connected configured ok Mfg: <undef> Product: <undef> NConfigs: 1 Config: 0 <no cfg str descr>
    unavailable usb-kbd n /devices/pci@8,700000/usb@5,3:1
    usb0/2 empty unconfigured ok
    unavailable unknown n /devices/pci@8,700000/usb@5,3:2
    usb0/3 connected configured ok Mfg: <undef> Product: <undef> NConfigs: 1 Config: 0 <no cfg str descr>
    unavailable usb-mouse n /devices/pci@8,700000/usb@5,3:3
    usb0/4 empty unconfigured ok
    unavailable unknown n /devices/pci@8,700000/usb@5,3:4
    and inquire still shows
    [email protected]:TOSHIBA DVD-ROM SD-M14011009|CD-ROM
    [email protected]:ADIC FastStor 2 A12r|Autochanger (Jukebox)
    [email protected]:HP Ultrium 1-SCSI E3 |Tape
    [email protected]:HP Ultrium 1-SCSI E3 |Tape
    and then I reconnect the cable I saw a lot of error message in dmesg:-
    Jun 19 13:47:37 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:47:37 server Received unexpected SCSI Reset
    Jun 19 13:47:37 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:47:37 server Received unexpected SCSI Reset
    Jun 19 13:51:30 server scsi: [ID 107833 kern.notice] /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:51:30 server Failed to Get Features
    Jun 19 13:51:50 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:51:50 server ISP: Firmware cmd timeout
    Jun 19 13:51:50 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:51:50 server Fatal error, resetting interface, flg 1
    and devfsadm hang. So I double check the past demsg and found a lot of similar SCSI error message as below:-
    Jun 19 13:43:12 server probe request for LUN 0 denied: max LUN -1
    Jun 19 13:43:12 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@5 (qus1):
    Is that represent a hardware failure either on the jukebox or the SCSI controller? Or it is indeed a software corruption that can only be solved by reinstallation? But unfortunately I don't have the media on hand.
    PS.a more details can be found under expert exchange thru the links below:-
    http://www.experts-exchange.com/OS/Unix/Solaris/Q_23413012.html#a21749881
    http://www.experts-exchange.com/OS/Unix/Solaris/Q_23478147.html

    My company have a SUN Storedge L8 attached to a SUN Solaris 9 (SPARC) while I can only do a tar to the /dev/rmt/0, whenever I tried to interact with the jukebox with the solstice backup, the program hang definitely.
    grep '/usr/kernel/drv/lus' /var/sadm/install/contents
    /usr/kernel/drv/lus f none 0555 root bin 34624 12073 993189557 SUNWsbus2
    /usr/kernel/drv/lus.conf f none 0444 root bin 3754 45438 993190441 SUNWsbus2
    /usr/kernel/drv/lus32 f none 0555 root bin 33444 4422 993213667 SUNWsbus2
    pkginfo -l SUNWsbus2
    PKGINST: SUNWsbus2
    NAME: Solstice Backup (Backup/Recover) Device Drivers
    CATEGORY: system
    ARCH: sparc
    VERSION: 6.1,REV=Build.186
    BASEDIR: /
    VENDOR: Sun Microsystems, Inc.
    PSTAMP: gelato010622054128
    INSTDATE: Apr 08 2003 13:25
    STATUS: completely installed
    FILES: 48 installed pathnames
    44 executables
    37896 blocks used (approx)
    this machine has installed the solstice backup manager
    pkginfo | grep -i Solstice
    system SUNWmibii Solstice Enterprise Agents 1.0.3 SNMP daemon
    system SUNWsacom Solstice Enterprise Agents 1.0.3 files for root file system
    system SUNWsadmi Solstice Enterprise Agents 1.0.3 Desktop Management Interface
    system SUNWsadml Solstice Launcher.
    system SUNWsadmx Solstice Enterprise Agents 1.0.3 Desktop Management Interface Libraries (64-bit)
    system SUNWsasnm Solstice Enterprise Agents 1.0.3 Simple Network Management Protocol
    system SUNWsasnx Solstice Enterprise Agents 1.0.3 Simple Network Management Protocol Libraries (64-bit)
    application SUNWsbuc Solstice Backup (Backup/Recover) Client
    application SUNWsbum Solstice Backup (Backup/Recover) Man
    application SUNWsbun Solstice Backup (Backup/Recover) Storage Node
    application SUNWsbus1 Solstice Backup (Backup/Recover) Server
    system SUNWsbus2 Solstice Backup (Backup/Recover) Device Drivers
    under the server->registration, I found that the registration contains :-
    Autochanger Module, 9 slots/9
    ClientPaks for Windows/1
    Networker for UNIX, Workgroup edition (8 clients per server)1 server
    Networker Module for Oracl/1
    BTW, inquire shows:-
    /etc/LGTOuscsi/inquire
    [email protected]:TOSHIBA DVD-ROM SD-M14011009|CD-ROM
    [email protected]:ADIC FastStor 2 A12r|Autochanger (Jukebox)
    [email protected]:HP Ultrium 1-SCSI E3 |Tape
    [email protected]:HP Ultrium 1-SCSI E3 |Tape
    where cfgadm -alv shows:-
    Ap_Id Receptacle Occupant Condition Information
    When Type Busy Phys_Id
    c0 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,700000/scsi@6:scsi
    c0::/dev/lus connected configured unknown TOSHIBA DVD-ROM SD-M1401
    unavailable CD-ROM n /devices/pci@8,700000/scsi@6:scsi::/dev/lus
    c0::dsk/c0t6d0 connected configured unknown TOSHIBA DVD-ROM SD-M1401
    unavailable CD-ROM y /devices/pci@8,700000/scsi@6:scsi::dsk/c0t6d0
    c1 connected configured unknown
    unavailable fc-private n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc
    c1::21000004cfe34092 connected configured unknown SEAGATE ST373307FSUN72G
    unavailable disk n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc::21000004cfe34092
    c1::21000004cfe34350 connected configured unknown SEAGATE ST373307FSUN72G
    unavailable disk n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc::21000004cfe34350
    c2 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,700000/scsi@6,1:scsi
    c2::lus1 connected configured unknown
    unavailable unknown n /devices/pci@8,700000/scsi@6,1:scsi::lus1
    c3 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@4:scsi
    c3::lus2 connected configured unknown HP Ultrium 1-SCSI
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@4:scsi::lus2
    c3::rmt/0 connected configured unknown HP Ultrium 1-SCSI
    unavailable tape n /devices/pci@8,600000/pci@1/scsi@4:scsi::rmt/0
    c4 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@5:scsi
    c4::lus3 connected configured unknown
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@5:scsi::lus3
    usb0/1 connected configured ok Mfg: <undef> Product: <undef> NConfigs: 1 Config: 0 <no cfg str descr>
    unavailable usb-kbd n /devices/pci@8,700000/usb@5,3:1
    usb0/2 empty unconfigured ok
    unavailable unknown n /devices/pci@8,700000/usb@5,3:2
    usb0/3 connected configured ok Mfg: <undef> Product: <undef> NConfigs: 1 Config: 0 <no cfg str descr>
    unavailable usb-mouse n /devices/pci@8,700000/usb@5,3:3
    usb0/4 empty unconfigured ok
    unavailable unknown n /devices/pci@8,700000/usb@5,3:4
    nsrjb shows
    Jukebox L8:
    slot volume pool volume id recyclable
    1: dwbak.inc.day0.wk0.001* 2481680129
    2: dwbak.inc.day0.wk0.002 DW Incremental 2481704705 no
    3: dwbak.inc.day0.wk0.003 DW Incremental 2481729793 no
    4: -* -
    5: dwbak.inc.day0.wk0.005 DW Incremental 2481779201 no
    6: dwbak.inc.day0.wk0.006 DW Incremental 2481804289 no
    7: dwbak.inc.day0.wk0.007 DW Incremental 2481829889 no
    8: dwbak.inc.day0.wk0.008 DW Incremental 2481854209 no
    *not registered in the NetWorker media data base
    drive 1 (/dev/rmt/0cbn) slot 5: dwbak.inc.day0.wk0.005
    nsrjb -HE hang indefinitly, so does nsrjb -HHE. devfsadm -c tape also hang while simply devfsadm can run without problem and cfgadm -alv c3 provide the following:-
    Ap_Id Receptacle Occupant Condition Information
    When Type Busy Phys_Id
    c3 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@4:scsi
    c3::lus2 connected configured unknown HP Ultrium 1-SCSI
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@4:scsi::lus2
    c3::rmt/0 connected configured unknown HP Ultrium 1-SCSI
    unavailable tape n /devices/pci@8,600000/pci@1/scsi@4:scsi::rmt/0
    nsjrb result should be past history, coz I am doing tar and manually changing the slot for quite some time already. Now I unconnect the cable and run devfsadm and then cfgadm -alv shows
    cfgadm -alv
    Ap_Id Receptacle Occupant Condition Information
    When Type Busy Phys_Id
    c0 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,700000/scsi@6:scsi
    c0::/dev/lus connected configured unknown TOSHIBA DVD-ROM SD-M1401
    unavailable CD-ROM n /devices/pci@8,700000/scsi@6:scsi::/dev/lus
    c0::dsk/c0t6d0 connected configured unknown TOSHIBA DVD-ROM SD-M1401
    unavailable CD-ROM y /devices/pci@8,700000/scsi@6:scsi::dsk/c0t6d0
    c1 connected configured unknown
    unavailable fc-private n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc
    c1::21000004cfe34092 connected configured unknown SEAGATE ST373307FSUN72G
    unavailable disk n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc::21000004cfe34092
    c1::21000004cfe34350 connected configured unknown SEAGATE ST373307FSUN72G
    unavailable disk n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc::21000004cfe34350
    c2 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,700000/scsi@6,1:scsi
    c2::lus1 connected configured unknown
    unavailable unknown n /devices/pci@8,700000/scsi@6,1:scsi::lus1
    c3 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@4:scsi
    c3::lus2 connected configured unknown HP Ultrium 1-SCSI
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@4:scsi::lus2
    c3::rmt/0 connected configured unknown HP Ultrium 1-SCSI
    unavailable tape n /devices/pci@8,600000/pci@1/scsi@4:scsi::rmt/0
    c4 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@5:scsi
    c4::lus3 connected configured unknown
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@5:scsi::lus3
    usb0/1 connected configured ok Mfg: <undef> Product: <undef> NConfigs: 1 Config: 0 <no cfg str descr>
    unavailable usb-kbd n /devices/pci@8,700000/usb@5,3:1
    usb0/2 empty unconfigured ok
    unavailable unknown n /devices/pci@8,700000/usb@5,3:2
    usb0/3 connected configured ok Mfg: <undef> Product: <undef> NConfigs: 1 Config: 0 <no cfg str descr>
    unavailable usb-mouse n /devices/pci@8,700000/usb@5,3:3
    usb0/4 empty unconfigured ok
    unavailable unknown n /devices/pci@8,700000/usb@5,3:4
    and inquire still shows
    [email protected]:TOSHIBA DVD-ROM SD-M14011009|CD-ROM
    [email protected]:ADIC FastStor 2 A12r|Autochanger (Jukebox)
    [email protected]:HP Ultrium 1-SCSI E3 |Tape
    [email protected]:HP Ultrium 1-SCSI E3 |Tape
    and then I reconnect the cable I saw a lot of error message in dmesg:-
    Jun 19 13:47:37 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:47:37 server Received unexpected SCSI Reset
    Jun 19 13:47:37 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:47:37 server Received unexpected SCSI Reset
    Jun 19 13:51:30 server scsi: [ID 107833 kern.notice] /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:51:30 server Failed to Get Features
    Jun 19 13:51:50 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:51:50 server ISP: Firmware cmd timeout
    Jun 19 13:51:50 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:51:50 server Fatal error, resetting interface, flg 1
    and devfsadm hang. So I double check the past demsg and found a lot of similar SCSI error message as below:-
    Jun 19 13:43:12 server probe request for LUN 0 denied: max LUN -1
    Jun 19 13:43:12 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@5 (qus1):
    Is that represent a hardware failure either on the jukebox or the SCSI controller? Or it is indeed a software corruption that can only be solved by reinstallation? But unfortunately I don't have the media on hand.
    PS.a more details can be found under expert exchange thru the links below:-
    http://www.experts-exchange.com/OS/Unix/Solaris/Q_23413012.html#a21749881
    http://www.experts-exchange.com/OS/Unix/Solaris/Q_23478147.html

  • Install SUN StorEdge L280 to Solaris 10 x86

    Hi, i need help with install & configure SUN StorEdge L280. I have SOLARIS 10 x86 platform on HP DL 380 g3. I need help with this. I dont understend what with this, what drivers is need... On sparc is all ok with veritas netbackup, but on x86...any help?thanks

    i need help with install & configure SUN StorEdge L280. I have SOLARIS 10 x86 platform on HP DL 380 g3. I need help with this. I dont understend what with this, what drivers is need... On sparc is all ok with veritas netbackup, but on x86...any help?thanks
    The L280 (or HP SureStore Autoloader 718) contains a DLT7000 drive. There is no reason why the generic SCSI tape driver doesn't support these drives.
    If you're asking for software to control the autoloader, a similar software like Veritas NetBackup is required. Veritas supplies a replacement driver.
    Now I see why your L280 doesn't work with your HP server. The L280 requires a HVD (High Voltage Differential) SCSI controller. The standard SCSI interface is SE (Single Ended) or LVD (Low Voltage Differential). Neither SE nor LVD are compatible with HVD. You won't see the device and can even damage the device and/or the controller.
    Get a HVD SCSI controller (Symbios SYM22802, Part-No 375-0006) or Adaptec AHA-2944UW (not AHA-2940UW which is SE!!).
    The Sun labeled HP Autoloaders (StorEdge L9, L280) use HVD SCSI while the original ones (SureStore 1/9, 718) use LVD or SE SCSI.
    Michael
    Robert,
    any update ?
    Message was edited by:
    MAALATFT

  • Veritas Volume manager 4.0 with Sun StorEdge 3310 D

    I am running into a problem. The vxconfigd deamon always dump core when rebooting.
    Our environment is listed below.
    OS environemt.
         SunOS server1 5.8 Generic_117350-43 sun4u sparc SUNW,Sun-Fire-V240
    Software installed.
         Sun Cluster 3.0
         Veritas Volume Manager 4.0 MP2.
    Disk Array associated.
         Sun StorEdge 3310 D.
    I looked up veritas.com and find Array Support Library (ASL) for Sun StorEdge 3xxx Series is recommended. But I didn't find this library is running on this server.
    Please refer to this following link
    http://support.veritas.com/docs/277923
    As our system is one of critical systems and I'd like to confirm that I can follow up this procedure without doing harm things to our system.
    Jeff

    No problem Jeff :)
    I took a look at the Veritas doc and you're right it does seem to cover everthing.
    Has the vxconfigd core dumped since the start? ie from the moment it was installed?
    I have installed VXVM 4.0 with Solaris 8 but without the ASL and this worked ok, I know that's not much help to you but I am not sure the ASL will help. Mind you I have not installed it with Sun Cluster 3.0.

  • Cluster and L1000 Tape Library

    We are planning to purchase a tape library system for backing up the data on our cluster. I was wondering if any one ever used the Sun L1000 Tape library system with NetBackup. How do you like the L1000 and NetBackup? Is the L1000 tape library reliable? What kind of throughput do you get? We have a 2-node cluster E5500/E4500. I am planning to connect the tape library to an E250 and use it as the backup server.
    Thank you in advance.

    hi sjen,
    it depends on the size of you databases and filesystems. the sun 250 should be ok, if you have enough memory. sometimes the network-interface (dfx) is a bottleneck.
    lg michael

  • Tape library compatibility.

    Hi I have no Solaris expertise. I work at Dell in support, and I have a customer that is trying to use a Power Vault 124T (Tape Library). I know that Dell has not verified the system with Solaris 10. I am trying to find a compatibility list from Sun, or proof that it is/is not supported. Could anyone help me out there? :)

    Thanks very much. That was all I needed. I was able to find the driver I needed throgh that page as well.

  • Tape library

    we want to buy tape library, our box is
    sun.
    after a little bit research,
    i decide to buy something from quantum.
    i read some doc from quantum, regarding
    DLT8000 it says that its native capacity is
    40G, what does that mean? i can always
    it should have a lot of tape inside,
    and i can always replace it,right?
    does that mean it at most can occupy
    tape upto 40G?
    null

    Quantum won't sell you the DLT 8000 drives unless you really push them. They had alot of problems with them and will steer you to the 7000. Look at the libs from Quantum/ATL, I have great luck with them. R

  • Sun StorEdge L25

    Our company have a SunToreEdge L25 tape library, it works normal for 4 years. It contains two HP Ultrium1 SCSI tape drives.
    I found some problem recently.
    1. The robot can not hold the tape when tape eject the tape. I can see the robot try to hold the tape from tape drive though the window of L25, after fail to hold tape several times, the L25 report a error message, the error code is 26C0, I check the guide, it said: Drive 1 has not responded to multiple requests to unload.
    But it does not occur every time. Sometimes, it is no problem. If I disable this tape drive, another drive does not have this kind of problems.
    I think I do not need to buy new tape drive, because the problem does not occur always.
    2. The power supply unit have three lights, both smaller lights is green, but the bigger one is in red, a warning message on screen, "PSU fail". Whether I need to change a new power supply unit?
    Thanks.

    Hello Prashant,
    It returned only the four internal SCSI drives and couldn't seem to find the tape library.
    maybe I have mis-read your post. Are the four internal drives the disk drives inside the V240 and the L25 isn't detected ? This misunderstanding might be caused by the fact that the L25 supports only upto 2 tape drives (the L100 upto 5 tape drives).
    Quote from the manual (L25-L100_install_guide, page 34ff):
    "The library robotics and tape drives are independent SCSI devices with
    independent SCSI connections. The L25 and L100 provide two 68-pin
    high density connectors for each device. You can connect these devices
    to a single SCSI bus or divide them between two or more SCSI buses."
    You have to review the cabling on the back of the L25 and the GUI configuration menu.
    Unfortunately you didn't tell what type of drives (DLT8000, LTO, SDLT) are installed and how the L25 is attached.
    Some drives require a HVD SCSI hba while other require a LVD SCSI hba. The installation guide mentions only HVD SCSI, but the Full Components List lists LVD SCSI adapters as valid choices (depending on the drive types installed!) too.
    HVD SCSI and LVD/SE aren't compatible.
    The LVD SCSI hba requires installation of some Solaris packages (the drivers aren't included with Solaris, but are on a CD that is supplied with the hba).
    Maybe someone else is able to assist you after you provided the missing information. I have no hands-on experience with the L25/L100, it's just from reviewing the manuals and the Sun System Handbook.
    Michael

  • SL500 Tape library Issue

    Hi Every one here
    I need some help with the SL500 Tape library
    I need to connect to the Library through the CLI port so I need to know the connection pin configuration
    I'll tell u what I do & any one who knows the connection tells me if it's wrong or what ?
    1)I'm using RJ-45 straight cable to connect to the CLI port
    2)from my lap top side I use usb-to-serial converter
    3)between both of them there is a converter which have DB-9 female from a side & RJ-45 interface from the other side which is the one that comes along with most of the sparc servers
    is this right ? or there is some special converters that comes along with the Tape library which may be had been lost in the customer site ? & if so can any one tell me the pin configuration of this converter & I will made up one ? if not may be the problem in the Straight RJ-45 cable which I use may be it's the wrong one knowing that I tried also cross-over & roll-over cables ?
    I tried to login using the admin username from the cross-over connection between me labtop & the library
    I use the Putty tool to ssh the IP address of the library when I type thw admin it prompts me the password & as sson as I type the password & press enter it logs me off
    why Can't I login to the CLI using ssh throught the ethernet cable or must I login to the library from the CLI port ???
    Regards

    Hi,
    There is a special DB9-RJ45 connector that comes with each STK/Sun libraries. You'll need it to establish a CLI connection. Server adapters does not function in libraries.
    Regards

  • Unable to restore from  Overland Tape library to STK 5320

    Hi,
    The Details are...
    STK 5320 (1.0.215.199)
    WindowXP System where the volume of the STK 5320 is maped (1.0.0.185)
    When restoreing a tape from Overland tape library using baracuda to STK 5320 maped volume we are getting the following log on the STK 5320.
    We have checked the permission and access status for the spdtest the are in full permission and read/write resp.
    Volume Name spdtest.
    {color:#ff0000}*03/01/10 17:07:54 W smbd[1.0.0.185]: refimg_unres access denied*
    *03/01/10 17:02:13 N smbd[1.0.0.185]: spdtest rw access granted*
    *03/01/10 17:02:12 I reauth: granted 1.0.0.185 to /SPDTest ro=0 uid0=0*
    {color}

    I opened the package and see lots of projects == are the projects in the Vault sufficient so that if I want to get the images and things out of those projects that would work?? In other words, skip the restoration totally and just open package contents and click and drag out of there?

  • Is possible control tape library slot 1 - 10 for file system backup

    hi ..
    i am new to osb , i just install and setup osb , i have a question as below , hope expert can help me
    env: testing
    rhel 5.5
    tape library with 20 slot
    file system backup
    1. is possible osb only use slot 1 - 10 for file system backup ? amanda can control slot x - slot y for the configuration .
    2. how do i label the tape for slot 1 - slot 10 by obtool ? how to control osb auto load the tape for next backup ? where to check the log say that next tape is tape-02 ?
    thanks ..

    hi dcooksey
    how do i use list for a tape drive...for example, if you want tape drive A to only use slots 1-10 from obtool or webtool ?
    becoz i new to backup solution & osb ( i always use ghost or acronis to clone the image ) , my thinking as below , pls correct me if i am wrong
    slot 1 - 10 for daily backup
    slot 11-16 for full system backup
    slot 17 - 20 reserve ( this tape only use for full system backup before perform any application upgrade patches , )
    daily backup mon - fri ( 2 week ) ( no backup on saturday and sunday ) , server application offline
    full system backup friday ( 1 , 14 on calendar ) every 2 week perform full system backup after daily backup completed
    for upgrade application ,
    perform full system backup after daily backup , then release the server to application team to perform upgrading .
    so how to set my media family for the above setting ? the slot configuration is control by media family ?
    hope you can help ...

  • How to set the IP address in L25 Tape library

    I try to set the ip address in L25 tape library. But it is not stored in the NVRAM. For that purpose I restart the device. Then all the values are reset. please tell how to set the ip address.

    Lylee,
    Please take a look at the following links.  The first describes how to distribute your application to multiple targets when using shared variables.  The others are explaining alternate ways to change the IP address of a controller.
    How Do I Distribute a Real-Time Application with Shared Variables to Multiple Users?
    http://digital.ni.com/public.nsf/allkb/20C9771687E6BBB3862570E7006C2284?OpenDocument
    How Do I Change the IP Address of a RT Series Controller (FieldPoint, cRIO, etc) that is not on the Local Subnet?
    http://digital.ni.com/public.nsf/allkb/9F7548F5C781E05586256C75006D8B94?OpenDocument
    Real-Time Target System Replication Tool
    http://digital.ni.com/public.nsf/allkb/444A6A22A6EC50FB86257213004A878C?OpenDocument
    http://digital.ni.com/public.nsf/allkb/DDD15965085446E68625733A00451C7A?OpenDocument
    Can I Programmatically Assign an IP Address to My Real-Time Target?

  • Sun StorEdge 3510

    Dears,
    Good day,
    I need your support to guide me to configure Sun StorEdge 3510. I have 24 Disks and single controller. I is connected to one host. I want to configure it with the most biggest storage. I want to implement RAID 5 on 11 disks on the first enclosure and the same to the second enclosure with two disks spare each one in the same enclosure.
    Can you guide me throw this?
    Thanks a lot.

    Wow, it took me about 5 hours to set mine up from scratch and I'm a pretty strong storage guy. Here's an overview of what I did. Most of the info is in the 3510 documentation.
    Step 1 is connectivity. Get your host to see the 3510 (FC).
    Step 2 - use the cli utilities to setup the IP address on the controller (in-band).
    Step 3 - ssh in, setup the RAID and presentation of the luns
    Step 4 - rescan on the hosts to see the new luns

Maybe you are looking for

  • Detecting object in images

    Hi, how can I detect objects in images using java ? I need to detect movements of an object in consecutive images exported from a video. thank you

  • One to One activation question

    I'm trying to activate my one to one membership. I can't get past step 3. It continues to tell me to review my info because it cannot keep my store location selected from step 2.  I've tried Safari, Firefox, and Explorer. Any advice?

  • What other V$ view than V$SESSION can provide the "program" column ?

    Hi all, We get a blank value , no value then, given by the "program" column of the V£SESSION view when our after logon database trigger fires. This is perhaps because we use a forms R6i application which uses a 8.0.6 version of oracle client. So I wa

  • Calendar on phone not showing birthdays

    HELP.... All by birthdays show up on mobile me and on my computer just not on my phone......

  • [SOLVED] I'd like to autostart X when I log in on concrete tty

    Hi all. Supposing I use a marginal ortodox weird window manager (notion - ion3 fork) and a relatively weird keyboard layout. Furthermore, when I'm using my laptop, sometimes I don't launch X, so I start X manually most of the time. What I want is X a