Sun storedge se 3310

Hello all,
I have created on a sun storedge se 3310 an RAID 5 array matrix with 4 disks (73 GB) for logical drive and a 5th disk (73 GB) for local spare. It seems that is taking a long time to be created and i can not see any activity on the servers leds.
Can anyone tell me how long it should take until the array will be finished?
Thanks

For SE3310 RAID 5 with 4HDD(73GB) you have to wait for about 1.5hrs to 2hrs. new LD be completely initialized, then after that you can perform lun mapping.

Similar Messages

  • Sun StorEdge[TM] 3510/3310/3511

    Dear
    What does the "2(3)" mean in the show disks output under the channel ID (Ch) for Sun StorEdge[TM] 3310/3510/3511
    :)Thanks
    Mohammed Tanvir

    Hi
    2(3) means there are two channels configured for the storedge 2 and 3 or I should say that it is in redundant mode. And at present control is with 2nd channel.
    Regards

  • Veritas Volume manager 4.0 with Sun StorEdge 3310 D

    I am running into a problem. The vxconfigd deamon always dump core when rebooting.
    Our environment is listed below.
    OS environemt.
         SunOS server1 5.8 Generic_117350-43 sun4u sparc SUNW,Sun-Fire-V240
    Software installed.
         Sun Cluster 3.0
         Veritas Volume Manager 4.0 MP2.
    Disk Array associated.
         Sun StorEdge 3310 D.
    I looked up veritas.com and find Array Support Library (ASL) for Sun StorEdge 3xxx Series is recommended. But I didn't find this library is running on this server.
    Please refer to this following link
    http://support.veritas.com/docs/277923
    As our system is one of critical systems and I'd like to confirm that I can follow up this procedure without doing harm things to our system.
    Jeff

    No problem Jeff :)
    I took a look at the Veritas doc and you're right it does seem to cover everthing.
    Has the vxconfigd core dumped since the start? ie from the moment it was installed?
    I have installed VXVM 4.0 with Solaris 8 but without the ASL and this worked ok, I know that's not much help to you but I am not sure the ASL will help. Mind you I have not installed it with Sun Cluster 3.0.

  • Sun Storedge 3310

    I would like to know if it is possible to connect a sun storedge 3310 array to windows server 2012 r2? If ther is could you tell me how. I know how to do it on server 2003 but 2012 r2 is much different.

    Hi,
    I would like to know if it is possible to connect a sun storedge 3310 array to windows server 2012 r2?
    Since we are not familiar with the product you have mentioned, I would suggest you contact corresponding vendor support to get more specific and accurate response.
    Thank you for your understanding and support.
    Best Regards,
    Amy
    Please remember to mark the replies as answers if they help and un-mark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact [email protected]

  • Connecting to a Sun StorEdge 3310

    Hello all,
    in our warehouse I've found a Sun StorEdge 3310. I want to try to use it but I do not have any kind of usefull serial cable. Also StorEdge has a LAN port but I'm not able to find a mac address to force ARP table and telnet it.
    Any hint to get my storage accessible?
    Thanks
    Stefano
    http://www.stefanocislaghi.it

    Please have a look at the installation document http://docs.sun.com/app/docs/doc/816-7290-19 and feel free to get back here if you still have questions.

  • Sun storedge 3310 fw 4.1.5f MIB ?

    Hi does anybody know where can I find the MIB snmp file for Sun storedge 3310 fw version 4.1.5.f ?
    Thanks

    Nevermind the last posts, I forgot to install the 32 bit drivers of ultra 3 card.
    Anyway thanks to anyone who might have thought about this.
    Orlando

  • Solstice backup 6.1 hang when invoking the autochanger "SUN Storedge L8 "

    My company have a SUN Storedge L8 attached to a SUN Solaris 9 (SPARC) while I can only do a tar to the /dev/rmt/0, whenever I tried to interact with the jukebox with the solstice backup, the program hang definitely.
    grep '/usr/kernel/drv/lus' /var/sadm/install/contents
    /usr/kernel/drv/lus f none 0555 root bin 34624 12073 993189557 SUNWsbus2
    /usr/kernel/drv/lus.conf f none 0444 root bin 3754 45438 993190441 SUNWsbus2
    /usr/kernel/drv/lus32 f none 0555 root bin 33444 4422 993213667 SUNWsbus2
    pkginfo -l SUNWsbus2
    PKGINST: SUNWsbus2
    NAME: Solstice Backup (Backup/Recover) Device Drivers
    CATEGORY: system
    ARCH: sparc
    VERSION: 6.1,REV=Build.186
    BASEDIR: /
    VENDOR: Sun Microsystems, Inc.
    PSTAMP: gelato010622054128
    INSTDATE: Apr 08 2003 13:25
    STATUS: completely installed
    FILES: 48 installed pathnames
    44 executables
    37896 blocks used (approx)
    this machine has installed the solstice backup manager
    pkginfo | grep -i Solstice
    system SUNWmibii Solstice Enterprise Agents 1.0.3 SNMP daemon
    system SUNWsacom Solstice Enterprise Agents 1.0.3 files for root file system
    system SUNWsadmi Solstice Enterprise Agents 1.0.3 Desktop Management Interface
    system SUNWsadml Solstice Launcher.
    system SUNWsadmx Solstice Enterprise Agents 1.0.3 Desktop Management Interface Libraries (64-bit)
    system SUNWsasnm Solstice Enterprise Agents 1.0.3 Simple Network Management Protocol
    system SUNWsasnx Solstice Enterprise Agents 1.0.3 Simple Network Management Protocol Libraries (64-bit)
    application SUNWsbuc Solstice Backup (Backup/Recover) Client
    application SUNWsbum Solstice Backup (Backup/Recover) Man
    application SUNWsbun Solstice Backup (Backup/Recover) Storage Node
    application SUNWsbus1 Solstice Backup (Backup/Recover) Server
    system SUNWsbus2 Solstice Backup (Backup/Recover) Device Drivers
    under the server->registration, I found that the registration contains :-
    Autochanger Module, 9 slots/9
    ClientPaks for Windows/1
    Networker for UNIX, Workgroup edition (8 clients per server)1 server
    Networker Module for Oracl/1
    BTW, inquire shows:-
    /etc/LGTOuscsi/inquire
    [email protected]:TOSHIBA DVD-ROM SD-M14011009|CD-ROM
    [email protected]:ADIC FastStor 2 A12r|Autochanger (Jukebox)
    [email protected]:HP Ultrium 1-SCSI E3 |Tape
    [email protected]:HP Ultrium 1-SCSI E3 |Tape
    where cfgadm -alv shows:-
    Ap_Id Receptacle Occupant Condition Information
    When Type Busy Phys_Id
    c0 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,700000/scsi@6:scsi
    c0::/dev/lus connected configured unknown TOSHIBA DVD-ROM SD-M1401
    unavailable CD-ROM n /devices/pci@8,700000/scsi@6:scsi::/dev/lus
    c0::dsk/c0t6d0 connected configured unknown TOSHIBA DVD-ROM SD-M1401
    unavailable CD-ROM y /devices/pci@8,700000/scsi@6:scsi::dsk/c0t6d0
    c1 connected configured unknown
    unavailable fc-private n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc
    c1::21000004cfe34092 connected configured unknown SEAGATE ST373307FSUN72G
    unavailable disk n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc::21000004cfe34092
    c1::21000004cfe34350 connected configured unknown SEAGATE ST373307FSUN72G
    unavailable disk n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc::21000004cfe34350
    c2 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,700000/scsi@6,1:scsi
    c2::lus1 connected configured unknown
    unavailable unknown n /devices/pci@8,700000/scsi@6,1:scsi::lus1
    c3 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@4:scsi
    c3::lus2 connected configured unknown HP Ultrium 1-SCSI
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@4:scsi::lus2
    c3::rmt/0 connected configured unknown HP Ultrium 1-SCSI
    unavailable tape n /devices/pci@8,600000/pci@1/scsi@4:scsi::rmt/0
    c4 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@5:scsi
    c4::lus3 connected configured unknown
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@5:scsi::lus3
    usb0/1 connected configured ok Mfg: <undef> Product: <undef> NConfigs: 1 Config: 0 <no cfg str descr>
    unavailable usb-kbd n /devices/pci@8,700000/usb@5,3:1
    usb0/2 empty unconfigured ok
    unavailable unknown n /devices/pci@8,700000/usb@5,3:2
    usb0/3 connected configured ok Mfg: <undef> Product: <undef> NConfigs: 1 Config: 0 <no cfg str descr>
    unavailable usb-mouse n /devices/pci@8,700000/usb@5,3:3
    usb0/4 empty unconfigured ok
    unavailable unknown n /devices/pci@8,700000/usb@5,3:4
    nsrjb shows
    Jukebox L8:
    slot volume pool volume id recyclable
    1: dwbak.inc.day0.wk0.001* 2481680129
    2: dwbak.inc.day0.wk0.002 DW Incremental 2481704705 no
    3: dwbak.inc.day0.wk0.003 DW Incremental 2481729793 no
    4: -* -
    5: dwbak.inc.day0.wk0.005 DW Incremental 2481779201 no
    6: dwbak.inc.day0.wk0.006 DW Incremental 2481804289 no
    7: dwbak.inc.day0.wk0.007 DW Incremental 2481829889 no
    8: dwbak.inc.day0.wk0.008 DW Incremental 2481854209 no
    *not registered in the NetWorker media data base
    drive 1 (/dev/rmt/0cbn) slot 5: dwbak.inc.day0.wk0.005
    nsrjb -HE hang indefinitly, so does nsrjb -HHE. devfsadm -c tape also hang while simply devfsadm can run without problem and cfgadm -alv c3 provide the following:-
    Ap_Id Receptacle Occupant Condition Information
    When Type Busy Phys_Id
    c3 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@4:scsi
    c3::lus2 connected configured unknown HP Ultrium 1-SCSI
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@4:scsi::lus2
    c3::rmt/0 connected configured unknown HP Ultrium 1-SCSI
    unavailable tape n /devices/pci@8,600000/pci@1/scsi@4:scsi::rmt/0
    nsjrb result should be past history, coz I am doing tar and manually changing the slot for quite some time already. Now I unconnect the cable and run devfsadm and then cfgadm -alv shows
    cfgadm -alv
    Ap_Id Receptacle Occupant Condition Information
    When Type Busy Phys_Id
    c0 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,700000/scsi@6:scsi
    c0::/dev/lus connected configured unknown TOSHIBA DVD-ROM SD-M1401
    unavailable CD-ROM n /devices/pci@8,700000/scsi@6:scsi::/dev/lus
    c0::dsk/c0t6d0 connected configured unknown TOSHIBA DVD-ROM SD-M1401
    unavailable CD-ROM y /devices/pci@8,700000/scsi@6:scsi::dsk/c0t6d0
    c1 connected configured unknown
    unavailable fc-private n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc
    c1::21000004cfe34092 connected configured unknown SEAGATE ST373307FSUN72G
    unavailable disk n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc::21000004cfe34092
    c1::21000004cfe34350 connected configured unknown SEAGATE ST373307FSUN72G
    unavailable disk n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc::21000004cfe34350
    c2 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,700000/scsi@6,1:scsi
    c2::lus1 connected configured unknown
    unavailable unknown n /devices/pci@8,700000/scsi@6,1:scsi::lus1
    c3 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@4:scsi
    c3::lus2 connected configured unknown HP Ultrium 1-SCSI
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@4:scsi::lus2
    c3::rmt/0 connected configured unknown HP Ultrium 1-SCSI
    unavailable tape n /devices/pci@8,600000/pci@1/scsi@4:scsi::rmt/0
    c4 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@5:scsi
    c4::lus3 connected configured unknown
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@5:scsi::lus3
    usb0/1 connected configured ok Mfg: <undef> Product: <undef> NConfigs: 1 Config: 0 <no cfg str descr>
    unavailable usb-kbd n /devices/pci@8,700000/usb@5,3:1
    usb0/2 empty unconfigured ok
    unavailable unknown n /devices/pci@8,700000/usb@5,3:2
    usb0/3 connected configured ok Mfg: <undef> Product: <undef> NConfigs: 1 Config: 0 <no cfg str descr>
    unavailable usb-mouse n /devices/pci@8,700000/usb@5,3:3
    usb0/4 empty unconfigured ok
    unavailable unknown n /devices/pci@8,700000/usb@5,3:4
    and inquire still shows
    [email protected]:TOSHIBA DVD-ROM SD-M14011009|CD-ROM
    [email protected]:ADIC FastStor 2 A12r|Autochanger (Jukebox)
    [email protected]:HP Ultrium 1-SCSI E3 |Tape
    [email protected]:HP Ultrium 1-SCSI E3 |Tape
    and then I reconnect the cable I saw a lot of error message in dmesg:-
    Jun 19 13:47:37 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:47:37 server Received unexpected SCSI Reset
    Jun 19 13:47:37 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:47:37 server Received unexpected SCSI Reset
    Jun 19 13:51:30 server scsi: [ID 107833 kern.notice] /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:51:30 server Failed to Get Features
    Jun 19 13:51:50 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:51:50 server ISP: Firmware cmd timeout
    Jun 19 13:51:50 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:51:50 server Fatal error, resetting interface, flg 1
    and devfsadm hang. So I double check the past demsg and found a lot of similar SCSI error message as below:-
    Jun 19 13:43:12 server probe request for LUN 0 denied: max LUN -1
    Jun 19 13:43:12 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@5 (qus1):
    Is that represent a hardware failure either on the jukebox or the SCSI controller? Or it is indeed a software corruption that can only be solved by reinstallation? But unfortunately I don't have the media on hand.
    PS.a more details can be found under expert exchange thru the links below:-
    http://www.experts-exchange.com/OS/Unix/Solaris/Q_23413012.html#a21749881
    http://www.experts-exchange.com/OS/Unix/Solaris/Q_23478147.html

    My company have a SUN Storedge L8 attached to a SUN Solaris 9 (SPARC) while I can only do a tar to the /dev/rmt/0, whenever I tried to interact with the jukebox with the solstice backup, the program hang definitely.
    grep '/usr/kernel/drv/lus' /var/sadm/install/contents
    /usr/kernel/drv/lus f none 0555 root bin 34624 12073 993189557 SUNWsbus2
    /usr/kernel/drv/lus.conf f none 0444 root bin 3754 45438 993190441 SUNWsbus2
    /usr/kernel/drv/lus32 f none 0555 root bin 33444 4422 993213667 SUNWsbus2
    pkginfo -l SUNWsbus2
    PKGINST: SUNWsbus2
    NAME: Solstice Backup (Backup/Recover) Device Drivers
    CATEGORY: system
    ARCH: sparc
    VERSION: 6.1,REV=Build.186
    BASEDIR: /
    VENDOR: Sun Microsystems, Inc.
    PSTAMP: gelato010622054128
    INSTDATE: Apr 08 2003 13:25
    STATUS: completely installed
    FILES: 48 installed pathnames
    44 executables
    37896 blocks used (approx)
    this machine has installed the solstice backup manager
    pkginfo | grep -i Solstice
    system SUNWmibii Solstice Enterprise Agents 1.0.3 SNMP daemon
    system SUNWsacom Solstice Enterprise Agents 1.0.3 files for root file system
    system SUNWsadmi Solstice Enterprise Agents 1.0.3 Desktop Management Interface
    system SUNWsadml Solstice Launcher.
    system SUNWsadmx Solstice Enterprise Agents 1.0.3 Desktop Management Interface Libraries (64-bit)
    system SUNWsasnm Solstice Enterprise Agents 1.0.3 Simple Network Management Protocol
    system SUNWsasnx Solstice Enterprise Agents 1.0.3 Simple Network Management Protocol Libraries (64-bit)
    application SUNWsbuc Solstice Backup (Backup/Recover) Client
    application SUNWsbum Solstice Backup (Backup/Recover) Man
    application SUNWsbun Solstice Backup (Backup/Recover) Storage Node
    application SUNWsbus1 Solstice Backup (Backup/Recover) Server
    system SUNWsbus2 Solstice Backup (Backup/Recover) Device Drivers
    under the server->registration, I found that the registration contains :-
    Autochanger Module, 9 slots/9
    ClientPaks for Windows/1
    Networker for UNIX, Workgroup edition (8 clients per server)1 server
    Networker Module for Oracl/1
    BTW, inquire shows:-
    /etc/LGTOuscsi/inquire
    [email protected]:TOSHIBA DVD-ROM SD-M14011009|CD-ROM
    [email protected]:ADIC FastStor 2 A12r|Autochanger (Jukebox)
    [email protected]:HP Ultrium 1-SCSI E3 |Tape
    [email protected]:HP Ultrium 1-SCSI E3 |Tape
    where cfgadm -alv shows:-
    Ap_Id Receptacle Occupant Condition Information
    When Type Busy Phys_Id
    c0 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,700000/scsi@6:scsi
    c0::/dev/lus connected configured unknown TOSHIBA DVD-ROM SD-M1401
    unavailable CD-ROM n /devices/pci@8,700000/scsi@6:scsi::/dev/lus
    c0::dsk/c0t6d0 connected configured unknown TOSHIBA DVD-ROM SD-M1401
    unavailable CD-ROM y /devices/pci@8,700000/scsi@6:scsi::dsk/c0t6d0
    c1 connected configured unknown
    unavailable fc-private n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc
    c1::21000004cfe34092 connected configured unknown SEAGATE ST373307FSUN72G
    unavailable disk n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc::21000004cfe34092
    c1::21000004cfe34350 connected configured unknown SEAGATE ST373307FSUN72G
    unavailable disk n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc::21000004cfe34350
    c2 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,700000/scsi@6,1:scsi
    c2::lus1 connected configured unknown
    unavailable unknown n /devices/pci@8,700000/scsi@6,1:scsi::lus1
    c3 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@4:scsi
    c3::lus2 connected configured unknown HP Ultrium 1-SCSI
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@4:scsi::lus2
    c3::rmt/0 connected configured unknown HP Ultrium 1-SCSI
    unavailable tape n /devices/pci@8,600000/pci@1/scsi@4:scsi::rmt/0
    c4 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@5:scsi
    c4::lus3 connected configured unknown
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@5:scsi::lus3
    usb0/1 connected configured ok Mfg: <undef> Product: <undef> NConfigs: 1 Config: 0 <no cfg str descr>
    unavailable usb-kbd n /devices/pci@8,700000/usb@5,3:1
    usb0/2 empty unconfigured ok
    unavailable unknown n /devices/pci@8,700000/usb@5,3:2
    usb0/3 connected configured ok Mfg: <undef> Product: <undef> NConfigs: 1 Config: 0 <no cfg str descr>
    unavailable usb-mouse n /devices/pci@8,700000/usb@5,3:3
    usb0/4 empty unconfigured ok
    unavailable unknown n /devices/pci@8,700000/usb@5,3:4
    nsrjb shows
    Jukebox L8:
    slot volume pool volume id recyclable
    1: dwbak.inc.day0.wk0.001* 2481680129
    2: dwbak.inc.day0.wk0.002 DW Incremental 2481704705 no
    3: dwbak.inc.day0.wk0.003 DW Incremental 2481729793 no
    4: -* -
    5: dwbak.inc.day0.wk0.005 DW Incremental 2481779201 no
    6: dwbak.inc.day0.wk0.006 DW Incremental 2481804289 no
    7: dwbak.inc.day0.wk0.007 DW Incremental 2481829889 no
    8: dwbak.inc.day0.wk0.008 DW Incremental 2481854209 no
    *not registered in the NetWorker media data base
    drive 1 (/dev/rmt/0cbn) slot 5: dwbak.inc.day0.wk0.005
    nsrjb -HE hang indefinitly, so does nsrjb -HHE. devfsadm -c tape also hang while simply devfsadm can run without problem and cfgadm -alv c3 provide the following:-
    Ap_Id Receptacle Occupant Condition Information
    When Type Busy Phys_Id
    c3 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@4:scsi
    c3::lus2 connected configured unknown HP Ultrium 1-SCSI
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@4:scsi::lus2
    c3::rmt/0 connected configured unknown HP Ultrium 1-SCSI
    unavailable tape n /devices/pci@8,600000/pci@1/scsi@4:scsi::rmt/0
    nsjrb result should be past history, coz I am doing tar and manually changing the slot for quite some time already. Now I unconnect the cable and run devfsadm and then cfgadm -alv shows
    cfgadm -alv
    Ap_Id Receptacle Occupant Condition Information
    When Type Busy Phys_Id
    c0 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,700000/scsi@6:scsi
    c0::/dev/lus connected configured unknown TOSHIBA DVD-ROM SD-M1401
    unavailable CD-ROM n /devices/pci@8,700000/scsi@6:scsi::/dev/lus
    c0::dsk/c0t6d0 connected configured unknown TOSHIBA DVD-ROM SD-M1401
    unavailable CD-ROM y /devices/pci@8,700000/scsi@6:scsi::dsk/c0t6d0
    c1 connected configured unknown
    unavailable fc-private n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc
    c1::21000004cfe34092 connected configured unknown SEAGATE ST373307FSUN72G
    unavailable disk n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc::21000004cfe34092
    c1::21000004cfe34350 connected configured unknown SEAGATE ST373307FSUN72G
    unavailable disk n /devices/pci@8,600000/SUNW,qlc@4/fp@0,0:fc::21000004cfe34350
    c2 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,700000/scsi@6,1:scsi
    c2::lus1 connected configured unknown
    unavailable unknown n /devices/pci@8,700000/scsi@6,1:scsi::lus1
    c3 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@4:scsi
    c3::lus2 connected configured unknown HP Ultrium 1-SCSI
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@4:scsi::lus2
    c3::rmt/0 connected configured unknown HP Ultrium 1-SCSI
    unavailable tape n /devices/pci@8,600000/pci@1/scsi@4:scsi::rmt/0
    c4 connected configured unknown
    unavailable scsi-bus n /devices/pci@8,600000/pci@1/scsi@5:scsi
    c4::lus3 connected configured unknown
    unavailable unknown n /devices/pci@8,600000/pci@1/scsi@5:scsi::lus3
    usb0/1 connected configured ok Mfg: <undef> Product: <undef> NConfigs: 1 Config: 0 <no cfg str descr>
    unavailable usb-kbd n /devices/pci@8,700000/usb@5,3:1
    usb0/2 empty unconfigured ok
    unavailable unknown n /devices/pci@8,700000/usb@5,3:2
    usb0/3 connected configured ok Mfg: <undef> Product: <undef> NConfigs: 1 Config: 0 <no cfg str descr>
    unavailable usb-mouse n /devices/pci@8,700000/usb@5,3:3
    usb0/4 empty unconfigured ok
    unavailable unknown n /devices/pci@8,700000/usb@5,3:4
    and inquire still shows
    [email protected]:TOSHIBA DVD-ROM SD-M14011009|CD-ROM
    [email protected]:ADIC FastStor 2 A12r|Autochanger (Jukebox)
    [email protected]:HP Ultrium 1-SCSI E3 |Tape
    [email protected]:HP Ultrium 1-SCSI E3 |Tape
    and then I reconnect the cable I saw a lot of error message in dmesg:-
    Jun 19 13:47:37 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:47:37 server Received unexpected SCSI Reset
    Jun 19 13:47:37 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:47:37 server Received unexpected SCSI Reset
    Jun 19 13:51:30 server scsi: [ID 107833 kern.notice] /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:51:30 server Failed to Get Features
    Jun 19 13:51:50 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:51:50 server ISP: Firmware cmd timeout
    Jun 19 13:51:50 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@4 (qus0):
    Jun 19 13:51:50 server Fatal error, resetting interface, flg 1
    and devfsadm hang. So I double check the past demsg and found a lot of similar SCSI error message as below:-
    Jun 19 13:43:12 server probe request for LUN 0 denied: max LUN -1
    Jun 19 13:43:12 server scsi: [ID 107833 kern.warning] WARNING: /pci@8,600000/pci@1/scsi@5 (qus1):
    Is that represent a hardware failure either on the jukebox or the SCSI controller? Or it is indeed a software corruption that can only be solved by reinstallation? But unfortunately I don't have the media on hand.
    PS.a more details can be found under expert exchange thru the links below:-
    http://www.experts-exchange.com/OS/Unix/Solaris/Q_23413012.html#a21749881
    http://www.experts-exchange.com/OS/Unix/Solaris/Q_23478147.html

  • Sun StorEdge 3510

    Dears,
    Good day,
    I need your support to guide me to configure Sun StorEdge 3510. I have 24 Disks and single controller. I is connected to one host. I want to configure it with the most biggest storage. I want to implement RAID 5 on 11 disks on the first enclosure and the same to the second enclosure with two disks spare each one in the same enclosure.
    Can you guide me throw this?
    Thanks a lot.

    Wow, it took me about 5 hours to set mine up from scratch and I'm a pretty strong storage guy. Here's an overview of what I did. Most of the info is in the 3510 documentation.
    Step 1 is connectivity. Get your host to see the 3510 (FC).
    Step 2 - use the cli utilities to setup the IP address on the controller (in-band).
    Step 3 - ssh in, setup the RAID and presentation of the luns
    Step 4 - rescan on the hosts to see the new luns

  • Install SUN StorEdge L280 to Solaris 10 x86

    Hi, i need help with install & configure SUN StorEdge L280. I have SOLARIS 10 x86 platform on HP DL 380 g3. I need help with this. I dont understend what with this, what drivers is need... On sparc is all ok with veritas netbackup, but on x86...any help?thanks

    i need help with install & configure SUN StorEdge L280. I have SOLARIS 10 x86 platform on HP DL 380 g3. I need help with this. I dont understend what with this, what drivers is need... On sparc is all ok with veritas netbackup, but on x86...any help?thanks
    The L280 (or HP SureStore Autoloader 718) contains a DLT7000 drive. There is no reason why the generic SCSI tape driver doesn't support these drives.
    If you're asking for software to control the autoloader, a similar software like Veritas NetBackup is required. Veritas supplies a replacement driver.
    Now I see why your L280 doesn't work with your HP server. The L280 requires a HVD (High Voltage Differential) SCSI controller. The standard SCSI interface is SE (Single Ended) or LVD (Low Voltage Differential). Neither SE nor LVD are compatible with HVD. You won't see the device and can even damage the device and/or the controller.
    Get a HVD SCSI controller (Symbios SYM22802, Part-No 375-0006) or Adaptec AHA-2944UW (not AHA-2940UW which is SE!!).
    The Sun labeled HP Autoloaders (StorEdge L9, L280) use HVD SCSI while the original ones (SureStore 1/9, 718) use LVD or SE SCSI.
    Michael
    Robert,
    any update ?
    Message was edited by:
    MAALATFT

  • Sun StorEdge L8 Tape Library (UREGENT!!)

    hi all
    help needed.. i am new in this.. i ahve to do backup in the Sun StorEdge L8 every weekend.. as usual i will unload the Tape 1 and load the Tape 2 for this weekend backup.. Recently the tape shows '!' at the Tape 2.. when i try to unload the Tape 2, it shows me no tape is load.. wat does the '!' means?? can anyone explain? is it the tape is bad??
    this is wat it shows when i mt staus
    HP Ultrium LTO 2 tape drive:
    sense key(0x6)= Unit Attention residual= 0 retries= 0
    file no= 0 block no= 0
    can anyone explain..
    Thanks..

    Hi Surajsid
    Do you still have a support contract for this Library ? If it's still showing the same issues after power cycling the drive I would log a call with Orcale/Sun.
    Have you changed anything in your backup environment lately ?
    Regards
    David

  • Two servers with redundant connections for Sun StorEdge 3320 SCSI arrays

    Hello All,
    I read in the "Sun StorEdge 3000 Family Installation, Operation and Service Manual" that it's possible to setup "two servers with redundant connections" but I never see a detailed schema to do this. I read also the "Best Pratices Guide" but this case is not mentioned. Is it really possible ?
    My objective is to split a Sun StoreEdge 3320 SCSI array between two hosts with dual redundant scsi connection.
    Thanks in advance for your answers.
    Francois.

    At first this sounded easy, but looking at the parts listing for the 3320 seems to indicate otherwise. They're listing different part numbers for the chassis and midplane...
    371-0105 chassis & midplane for JBOD
    371-0106 chassis & midplane for RAID array
    There are also different part numbers for the I/O boards....
    370-7655 RAID SCSI I/O module
    370-7713 JBOD SCSI I/O module
    I can see what the difference is between the I/O modules, but am unsure of what differences if any are in the chassis and midplane. Seems like there's more involved here than what it would be worth to try and make it work. Perhaps the cost of a second HBA would be the lesser of two evils..........

  • Sun Storedge L9 command utility, need to load and unload tapes.

    I am looking for a utility that will unload, and reload an L9 Sun storedge.
    I found:
    http://www.sun.com/bigadmin/jsp/descFile.jsp?url=descAll/l9ctl
    This utility has some calls that either we don't have, or I can't find:
    loadmedia.cgi
    inloadmedia.cgi
    Am I setting this up incorrectly?
    Where is this stuff supposed to be?
    I am running on a sun ulta-5, Solaris 8.

    Hello!
    Before use, You should small customize script:
    1) Change
    $LibraryHostName="http://l9"; - It's library hostname.
    Or set this name in /etc/hosts
    $AdminPwd="12341234"; - password to Library
    And, of course, before use this script - you should setup netwotk connection of L9.
    Another way - use project MTX.
    http://freshmeat.net/projects/mtx/releases
    This program use SCSI commands for control library.
    Regards.

  • Are SUN StorEdge c2 and  Sun Storagetek C2 the same ?

    Hello All,
    Are SUN StorEdge c2 and Sun Storagetek C2 the same ? or are they 2 different products.
    Thanks
    Venkat Jupalli

    mmmmn, not sure about this one, but I would assume that moving from StorEdge to Storagetek is brand name related and came about from Sun Microsystems' acquisition of StorageTek late '05. Call marketing for more information.

  • Multi-initated LUNS on Sun StorEdge 3310

    I recently received two Sun V20Zs and a StorEdge 3310, and I am asked to cluster these two machines with the 3310 as shared storage. 3310 came with two raid controllers.
    My question is, could I create multi-initiaged LUNs and have these LUNs mapped by the V20Z. Reason behind having the multi-imitated LUNs is it will facilitate fail-over in case a one of the V20Z are unavailable.
    V20Zs are running Fedora Core 3.
    Thanks for your help.

    A good output that would give you a hint of a problem is iostat -En
    This output reports anykind of errors to a particular disk since the last reboot. If you are seeing high error numbers, then you can move onto running a file system check - fsck - on the drive.
    If you have anykind of RAID setup, check to see if any issues are being reported. Depending on what you are using to manage the RAID - Veritas Volume Manager or Solaris Disk Suite - they will most certainly tell you if there is an issue. A vxprint for Veritas and a metastat for DiskSuite will show you what you have setup and if there are any recognized disk issues.

  • Disk error message on Sun StorEdge 3310.

    Hi guys,
    Does anyone see the following error message in the /var/adm/messages? Should I have to replace this faulty disk?
    Mar 6 11:06:21 balrog scsi: [ID 107833 kern.warning] WARNING: /pci@1d,700000/sc
    si@1/sd@5,0 (sd36):Mar 6 11:06:21 balrog Error for Command: write(10) Error Level:Retryable
    Mar 6 11:06:21 balrog scsi: [ID 107833 kern.notice] Requested Block: 5491072 Error Block: 5491079
    Mar 6 11:06:21 balrog scsi: [ID 107833 kern.notice] Vendor: SEAGATE
    Serial Number: 0447B9LRDV
    Mar 6 11:06:21 balrog scsi: [ID 107833 kern.notice] Sense Key: Hardware Error
    Mar 6 11:06:21 balrog scsi: [ID 107833 kern.notice] ASC: 0x32 (no defect spare location available), ASCQ: 0x0, FRU: 0x4
    Looking forward to your comments.
    Jeff.

    A good output that would give you a hint of a problem is iostat -En
    This output reports anykind of errors to a particular disk since the last reboot. If you are seeing high error numbers, then you can move onto running a file system check - fsck - on the drive.
    If you have anykind of RAID setup, check to see if any issues are being reported. Depending on what you are using to manage the RAID - Veritas Volume Manager or Solaris Disk Suite - they will most certainly tell you if there is an issue. A vxprint for Veritas and a metastat for DiskSuite will show you what you have setup and if there are any recognized disk issues.

Maybe you are looking for

  • Function module is not working properly in background

    Hi  all, i have used one Function module 'PRICING' in user exit SAPMV45A to calculate pricing for sales order. i am using BAPI_SALESORDER_CHANGE to change the sales order pricing.         when i run the program in foreground, all condition records fo

  • How to setup a guest network when the dialogue boxes do not show up in AirPort Utility 6.1

    How do I setup a guest network when the dialogue boxes do not show up in AirPort Utility 6.1? I see screenshots where there are boxes to 'enable' guest network but these simply do not apear on the Wireless tab in AirPort Utility

  • Windows SBS 2003 to Server 2012 Essentials R2

    I am tasked with upgrading from an existing SBS 2003 server to 2012 R2 Essentials. Currently the 2012 box is on the network, fresh install but I'm encountering issues from there. I joined it to the domain and now when it boots up it goes through the

  • Beginner's JSF problems

    Hi - I'm a beginner at using JSF. I've worked with Java and Struts, and I'm comfortable with Netbeans. I'm working through some example code from one of the JSF books and I'm having the following problems: 1) The following code simply doesn't work...

  • Issue while scheduling job of Delete program of Archiving Object

    Please help me. I am working on SARA and clicked on delete program for Purchase Order. When the job was executed, i checked logs and i found that there is some error and the job was cancelled. The main problem is when i checked the EKKO table, the en