Supress warning msg during RRI

We have a query that jumps to R/3 tcode. when we try to jump, for some document no's the jump goes smooth .. for some other doc's, it throws a warning msg saying that the infosource is not linked to the source system. this happnes with some of the docs only. But the jump does go thru to R/3.
I want to supress the warning msg during the jump. I tried in RSRT, but it doesnt help. the error code i get is RSBBS206. where do i have to exactly supress this warning?
Any pointers or clues would be appreciated.
thanks,
Voodi

Hi Vodi,
In RSBBS, go to the sender query in change mode. There should be a tab in the middle column where you have to give your infosource name..
For. eg If you want to jump from Cost centre report (BW) to Masterdata transaction in R/3, you ust assign this particular infosource in RSBBS settings..
Hope it helps.

Similar Messages

  • Warning Msg during RRI

    When I'm trying to jump from a source report to target query via RRI, i get a warning msg (thought the query runs). I want to supress the msg.
    I tried supressing the msg in source query, target query and both of them together. Still the msg is being displayed. Where do I need to supress the msg if its during RRI process?
    The variable and the hierarchies being used for cost center is the same in both the queries. Any thoughts?
    Error msg:
    Invalid filter on 0COSTCENTER: Filter changed
        Message no. BRAIN502
    Diagnosis
        You tried to filter on a characteristic with active presentation
        hierarchy by a node of another hierarchy.
        This can only be done by switching the hierarhcy or for example by using
        the report/report interface.
    System Response
        The filter is not evaluated for the characteristic, but removed instead.
    Procedure
    Procedure for System Administration

    Thanks guys, I figured it out.
    Message was edited by:
            voodi

  • Supress warning msg in BADI

    Hi ,
    i have a requirement in which i need to suppress the warning message , which is coming while creating/changing PO .
    i have done it using  " mmpur_remove_messages_by_id  " and    " mmpur_remove_msg_by_context "   , but the issue is it is removing all the message of the corresponding given ID , and i need to remove just 1 warning message of that ID.
    ANY SUGGESTIONS ?
    Thankx in advance
    rahul

    thankx

  • WARNING MSG . DURING J1IEX

    Dear All ,
                             user had created a Stock transfer P.o , in this P.o there in no tab of  invoice , now it's Goods rcvd  is done here all excise details are maintained , here exscise base value is visible for all line items . now user had to post J1IEX so as he clicks on simulate a warning msg comes that is -" PLEASE CHECK EXCISE BASE FOR ITEM IS ZERO ! ".
    Pl help what to do .
    sap11

    Thanks guys, I figured it out.
    Message was edited by:
            voodi

  • Report to Report Interface warning msg

    Hi,
    I am getting "Incompatible for target selection for fiscal year" warning msg in SAP BEX.I am using same variable in my source and target system to select fiscal year.
    How to supress this warning message?
    thanks
    venkii

    If your report is working fine as per expectation in RRI, and your requirement is to supress the warning message, you can set the global setting of the workbook to supress any warning messages.
    Question:
    Do you have any customer exit on this variable?
    - Danny

  • Sales order- Warning msg Static credit check

    Hi, SAP Guru,
    When I create a order & saving it ...a POP UP comes with warning msg the static credit limit exceeds..... Can any one please let me know the how I can remove the warning POP UP . As client do not want any pop up should come while saving the order.
    Please help.
    Thx & regards

    Hi,
    If you remove the entry from the field "Check credit" in "OVAK" T.Code,the credit check will not happen for this order type.Which we don't want.
    We need that the credit check should happen but the pop-up is to be removed.right?
    For this goto the T.Code "OVA8".
    Select your valid entry.Details.
    Remove the value as "blank" for the field "Reaction".Press F4 for more options.
    Beside this there is one more field "status/block" which is ticked means the order will be blocked for further transactions.And also status will be updated accordingly.
    These blocked order have to be released either by using the T.Code "VKM3/VKM1".
    Regards,
    Krishna.

  • WARNING MSG

    had my iphone with me out by the pool... it was on the side face down exposed to the sun... warning msg came up with a yellow triangle with an ! in the middle and the word temperature above it... seems to be working fine now... but was playing my ipod at the time and it just stopped playing...

    If the phone gets too hot, it will shut itself down. See p. 132 of the manual... http://manuals.info.apple.com/enUS/iPhone_UserGuide.pdf

  • Ho do we make msg. CK666 become warning msg when we do costing run?

    Dear Experts,
    The sys. activate transfer price for preserve use.
    When we do costing run for profit center valuation, the following error msg ocurred.
    CK666 Material 227BO0001/plant 1030: Transfer price could not be found.
    Diagnosis
    When switching profit center 0000008000->0000005000 (from the material component to the costing object), a transfer price could not be determined for transfer price variant 0 in respect of material 227BO0001 in plant 1030.
    System Response
    If you carry out costing for a profit center valuation, material 227BO0001 goes into the cost estimate without a value.
    If you create a cost estimate for group valuation, profit from material 227BO0001 is not transferred into the cost component split.
    Procedure
    Check the settings for transfer price variant 0.
    In OKEQ, the variant for TP is blank.
    Ho do we make msg. CK666 become warning msg when we do costing run? and let costing result can be release, or there's another way?
    Thanks in advance.

    There is alternative solution.
    Try using TCode SE91.
    Enter the class - CK and Enter the message number 666.
    Select that line message line.
    Go to Utilities, Click on "Where-Used-list" or press "CtrlShiftF3" from keyboard.
    Select programs and deselect all others.
    Identify your program and double click against that under short description.
    There you can change the letter from "E" to "W" as your requirement.
    NOTE: take assistance of ABAPer of this, Do enquire about the implication of the same in sandbox before doing anything on any other client.
    Thanks & Regards
    JP

  • Where warning msg & error  msg are maintained in SPRO

    Dear All,
                              pl give the menu path to know that Where warning msg & error  msg are maintained in SPRO.
    regards
    sap11

    Hi,
    In case of Purchasing, the path to maintain warning & error messages is:
    Material Management->Purchasing->Environment Data->Define Attributes of System Messages
    In case of Inventory Management,
    Material Management->Inventory Management and Physical Inventory->Define Attributes of System Messages
    In case of External Service Management,
    Material Management->External Services Management->Define Attributes of System Messages
    In case of Logistics Invoice verification,
    Material Management->Invoice Verification->Logistics Invoice Verification->Define Attributes of System Messages
    In case of Material Master,
    Logistics - General->Material Master->Basic Settings->Define Attributes of System Messages
    Then, for eash message no., Maintain whether the message is to be shown as warning or error or information message.
    Reward if useful.
    Thanks & Regards,
    Komal

  • Warning msg "Signal is not contiguous"

    Hi,
    I used NI FGen to generate a sine wave to pump into a circuit (under test) and use NI Hi-speed Digitizer to capture the output of the circuit.
    The captured signal goes through a low pass filter.  This warning message appear at the filter when it is Run continuously.
    'Run Once' does not have problem.
    Has this got to do with synchronizing  the 2 modules in the PXI system or is it a matter of wrong sample rates.
    I have searched Help and it mentioned using TClk to synchronize the 2 modules. 
    How do you use TClk in Signal Express?
    How to solve this warning msg?
    Someone please help.....thanks.
    Regards,
    SeeMist

    Hello,
    I am glad to hear that you resolved the warning issue.  In regard to the other project, are you just interesting in generating the signal once?  What is the lay out of the steps in the project for both the FGEN and SCOPE?  Is the FGEN set to finite or continous generation mode?  How is the SCOPE step setup in the Execution Control tab? 
    SeeMist wrote:
    Currently (another project) I use the NI-FEN step to generate a signal from a .hws file (a 25khz burst signal).
    It works fine by itself and the "Scope Soft Front Panel" (SFP) is always good at capturing the generated signal.
    (The output of generator is externally connected to the input of the Scope).
    However, after I closed the SFP and inserted NI-Scope Acquire step in Signal Express, I was not always successful in capturing the signal generated.  Sometimes okay, sometimes not.
    The error occurred at the FGen step : "Finite Generation timeout"
    Do I have to initialise or there is a problem with my setting?  Trigger or synchronization problem?
    The setting of the FGen remains the same in both tests.
    The NI-Scope: Trigger = Edge ; Sample rate =100MS/s; Record Length =5000
    Samantha
    National Instruments
    Applications Engineer

  • Warning msg at the time of PR creation

    When I am creating the PR a Warning msg is being displayed as:-
    "Base unit of measure KG adopted from  material master record"
    Could anybody suggest me, why this msg is comming.
    and if I ignore it and go ahead with pressing enter, Is there any future impact by the same.

    Hi There
    When you create the PR, if you have not provide the unit of entry, System will read the master data and bring the base unit of measure,, and provide the warning message,, You can acknowledge that message and proceed further it is not an issue,,
    For more details ref the below link, it provides the details of diff units and usages,,
    http://help.sap.com/saphelp_46c/helpdata/en/a5/63310c43a211d189410000e829fbbd/content.htm
    Thanks
    Senthil

  • Warning msg. when trying to activate MP

    guys,
    I am trying to activate MP, and i am getting following Waring msg. ! what does it mean ? and how serious it it ?
    "The InfoProvider properties for ZCIA_M05 are not the same as the system default
    Message no. BRAIN376"
    thanks

    yes i did assign all the infoobject. i could activate it too, but before i could activate it, i got a warning msg.
    still, i ignore those and activate it.
    but i wasnt sure i serious it. Also i checked MP's properties and its all the same( like other MPs).
    But, i thought let me get some information from Experts about that worning !!!
    let me know if you have any idea about it.
    Also, When i was trying to Activate MP again, it was asking like " its already active, do u still want to active" and if i say yes, it
    gives me an error msg. " MP is not yet Locked"
    Do i need to Lock it ????? what is that ??
    thanks

  • Warning Msg - While checking Mulitproviders

    Hi Frds,
    When i am trying the check the mulitproviders, we are getting warning msg. Below is the warning msg which we getting.
    Error messages from point of view of OLAP processor:
    Message no. R7I127
    Now we have upgrade our patch level from 16 to 21.
    Kindly can anyone give me some solution to overcome these warning msg.
    Thanks
    Yuvi

    Has the MultiProvider ever been activated in the past? If you activate it, and it hasn't been activated previously, you'll get this message from time-to-time (another one of those "undocumented features"). After actiavting it, go back into the MultiProvider in edit mode and run a check on it. It shouldn't throw that warning anymore.

  • In Windows 7 warning msg says another version of Adobe CC installer is running while updating LR 5 to 6

    In Windows 7 warning msg says another version of Adobe CC installer is running while trying to update LR 5 to LR 6.

    Hi There,
    Kindly restart the machine and try to initiate the installation again.
    Download Lightroom 6: Digital photography software | Download free Adobe Photoshop Lightroom CC trial
    Serialize Lightroom CC trial to activate as Lightroom 6:https://helpx.adobe.com/lightroom/kb/serialize-lightroom-cc-trial-to-activate-as-lightroom -6.html
    Thanks,
    Atul Saini

  • ERROR MSG DURING ATTEMPT TO SAVE A QUERY ON LOCAL

    Hi Experts,
    Kindly help me out
    ERROR MSG DURING ATTEMPT TO SAVE A QUERY ON LOCAL
    status message : Errors: Authorization change not available for query

    Hi Surendra,
    Nw while i executing this query in production system
    Error i gt:   1.  Infoprovider was changed or activated at runtime
                      2.  system error in program CL_RSD_Multiprov and form GET_PART_IOBJNM_CMP_01
    Kindly give me some inputs
    Thnks
    Sinu