Switch 2960-S
Good evening,
I have purchased a new 2960 - S switch catalyst and have configured one SVI (interface -Layer 3). But my problem is that can't to use the show ip route command on this model.
This device has the universalk9 flash.
Thanks in advance!
You won't be able to, because it's a L2 switch, i.e. it cannot route!
Martin
Similar Messages
-
AAA configuration on switches 2960
Hi
I have introduced the following configuration of AAA in the switches of series 2950 and works very well,
but when I do the same in switches 2960, the local password does not work and it is obligatory to introduce the switch in the ACS to have management of the switch.
Is needed some additional configuration of AAA in switches 2960?
Thanks.
tacacs-server host y.y.y.y
tacacs-server key xxxxx
aaa new-model
aaa authentication login acceso-consola group tacacs+ line
aaa authentication login acceso-telnet group tacacs+ line
aaa authentication enable default group tacacs+ enable
aaa authorization commands 1 default group tacacs+ if-authenticated
aaa authorization commands 15 default group tacacs+ if-authenticated
aaa accounting commands 1 default start-stop group tacacs+
aaa accounting commands 15 default start-stop group tacacs+
line con 0
exec-timeout 0 0
login authentication acceso-consola
line vty 0 4
login authentication acceso-telnetMaria
Perhaps some clarification of your environment might help us. In particular it would help to understand how you produce the "without ACS" environment.
Clearly the switch is still configured for ACS. And clearly there is connectivity from the switch to the ACS. And the ACS is responding to the authentication request from the switch. I am not sure what the errno 254 represents or what on the ACS server causes it. Perhaps you can help us understand that?
I had a situation at one point that may have been similar to your situation. Our devices were sending requests to ACS. But ACS was not able to communicate with the external DB because one of the services on ACS was not running. ACS responded with an error indicating unable to process. But the IOS devices were not interpreting that as an error that should send them to the backup authentication method.
If you are stopping something on the ACS server then I would suggest that a better test would be to break IP connectivity between the switch and the ACS so that the switch receives no response to its request or to change the configured IP address for the server in the switc and point to some device not running ACS so that the switch receives a port unreachable response to its request. Those would give you a better test of without ACS.
HTH
Rick -
i want to know if this model (WS-C2960X-48TS-LL ) from switch 2960-X with lan lite support DHCP server ?
Hi!
I don't think L2 Access switch will be act as DHCP server, but you can check it here (based on IOS ver.)
http://tools.cisco.com/ITDIT/CFN/jsp/by-feature-technology.jsp
Feature info: search for: DHCP server / view image-detail.
P.S. strange it shows DHCP SERVER even with lanlite ios. probably Feature Navigator is not the best source
Have a nice day,
Dmitry -
How to connected mgmt port on switch 2960 -XR
Hi guys,
I need of a technical support to resolve a issue with some Switch 2960-XR and its MGMT Port installed on our infrastructure.
I'd like to reach it via ssh connection to management them from a remote station (my PC), some guides found on Internet suggested me to use a extenal Hub/switch and a PC dedicated for that like this:
|SW1 mgmt port|------|H|
|SW2 mgmt port|------|U|-------- PC
|SW3 mgmt port|------|B|
I've also tried to patch the mgmt port on a port tagged with a management VLAN but it's not worked.
I ask you if there is a way to reach that SW using mngt port without use another external SW, thanks in advance for your supportOur network is hybrid, we have CIsco Sw and IBM Sw.
For the IBM solution the configuration of mgmt port is inband (data) and use an interface called IP2 where assigning an IP address we can manage via ssh the sw. In this case we've created a dedicated Vlan 15 and assigned as IP 10.10.10.15/24 to the interface IP2.
In Cisco Sw the only ways I know is either to create a dedicated Vlan with an IP or using Out of band, but in this case I've to use an external Sw.
Which is the best solution to have the management port on Cisco Sw without to use out of band?
thanks -
Packets input or output in switch 2960
Hi all,
How to know have packets input or output of one port in switch 2960 Catalyst. Thanks you!Thank for your answer.
I have some problems involved Cisco Catalyst 2960 Switch.
I am using a device which includes Marvell PHY chip 88E1111. The device can send and receive PTP packet to and from my PC.
Now, I want to connect the device and the PC to Cisco Catalyst 2960 Switch, which will help me trace all of packets in the network . The test scenario is below:
- Switch: Cisco Catalyst 2960
- Tracer: Wireshark software
- PC: Windows 7-64 bit, plugging in Switch port 1 (interface 1)
- Device: FPGA board, plugging in Switch port 2 (interface 2),
operating mode: 1000Mbps, Fullduplex, no auto-negotiation, no auto power efficient-ethernet.
- Interface 2 of the Switch is static set by the device’s MAC
address , which ensures the Switch known the device’s MAC.
I suffered a problem. Although the RJ45 TX status led are on, there is not any packet sent to the Switch. I have no idea in this case.
Could you give me an advise please. -
warm greeting, I require to administer or enable by HTTP switch 2960. Somebody could to send the steps to do this activity,
My email is [email protected]
thank you very much,
John Jairo Osorioconf t
ip http server
end
wr -
NAC is not managing new Cisco Switch 2960S
Hello,
we want to add a Cisco Switch 2960S to the devices, but CAM says he is unable to control that switch.
The switch type Cisco WS-C2960-8TC-L is already running on the CAM.
Is there a OID Update for the 2960S?
Our CAM version is 4.5.1.Solution:
Use the update on CAM:
-> Device Management -> Clean Access -> Updates -> Update
to get new OIDs for the switches.
This solved the problem. The device was added afterwards successfully. -
New Accesslayer Switch 2960S vs 3560X
Hallo together,
so we plan to acquire new access layer switches for a medium sized LAN.
So there are three switch types we shortlisted.
1. WS-C3560X-48P-L
2. WS-C2960S-48LPD-L
3. WS-C2960S-48LPS-L
So could anybody tell me advantages / disadvantages of the 2960S against the 3560X and vice versa? Except some Layer 3 features and the Uplinkports of the Cat LPS, i can't see great distinctions.
Thanks for answer.Hi there,
given that you already accounted for Layer 3 and that you are planning on LAN Base 3560X. lets say it gives you a total of 435W of POE power, while 2960S gives you 370W per chasis, in case u r planning for PoE. But its stackable unlike 3560's.
in 3560 you get a bit more flexiblity in QoS, but not that much though.
then I'd say, here come's the price!
Hope it Helps,
Soroush. -
whether 2960 is a l2 layer or l3 layer
Cisco introduced Layer 3 switching on the 2960S, 2960G, 2960, and 2975 series switches when running the LAN BASE IOS with version 12.2(55)SE.
But there’s a small catch…it does NOT support RIP, OSPF, EIGRP, BGP, or routed interfaces. It ONLY supports 16 static routes with SVIs.
http://www.cisco.com/en/US/docs/switches/lan/catalyst2960/software/release/12.2_55_se/configuration/guide/swipstatrout.html
Hope this helps
Sent from Cisco Technical Support iPhone App -
Cisco Switches (2960 Series) Management
We are managing these devices using HP OpenView Network Node Manager (Ver. 7.5) on HP-UX platform.
What are the known problems, limitations on its initial discovery and on later stages of managing the same ?The Cisco Catalyst 2960 Series supports the Cisco IOS LAN BASE software image. This software image is a rich suite of intelligent services that is also available in a crypto image at no additional charge.
Cisco Network Assistant also offers centralized management and configuration of Cisco switches and other Cisco devices such as routers and wireless access points. With Cisco Network Assistant, in addition to configuring multiple switches at a time, you can configure Cisco wireless access points, and invoke the Device Manager on Cisco routers and access points. Cisco Network Assistant can be downloaded (available at no cost).
This URL should help you:
http://www.cisco.com/en/US/products/ps5931/index.html -
Hello,
I am ordering cisco 2960 series. I need the following features only. please recommend which IOS i should order with it. LAN_Base or LAN_Lite ?
Features I need >>
802.1X
VLAN Management Interface supportLAN Lite is always very limited in terms of features and doesn't give you much more then basic switching. For 802.1X you find the available features in the config-Guide:
http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst2960x/software/15-2_2_e/security/configuration_guide/b_sec_1522e_2960x_cg/b_sec_1522e_2960x_cg_chapter_010.html -
How can I configure a 802.1x in a switch 2960 with IOS 15.0.2?
Hi,
I'm trying to config a switch WS-C2960+24PC-L with IOS 15.0(2)SE5 and C2960-LANBASEK9-M to use 802.1x in my network but when I type the following commands the IOS doesn't recognize the interface commands and I can't complete the settings:
Router# configure terminal
Router(config)# dot1x system-auth-control
Router(config)# aaa new-model
Router(config)# aaa authentication dot1x default group radius
Router(config)# interface fastethernet2/1
Router(config-if)# switchport mode access
Switch(config-if)# authentication port-control auto (or dot1x port-control auto)
Switch(config-if)# authentication host-mode multihost
Router(config-if)# dot1x pae authenticator
Router(config-if)# end
Source: http://www.cisco.com/en/US/docs/ios-xml/ios/sec_usr_8021x/configuration/15-2mt/config-ieee-802x-pba.html#GUID-C11588CB-31B6-4CD9-9E74-CF2199FB1807
I've used the same commands in other switch with IOS 12.x and I don't have any problem to complete the settings so.... somebody know if:
* Should I use others commands to activate this feature in this IOS?
* Do I need to use other IOS?
Thanks in advance,The authentication manager commands in Cisco IOS Release 12.2(50)SE or later
The equivalent 802.1x commands in Cisco IOS Release 12.2(46)SE and earlier
Description
authentication control-direction { both | in}
dot1x control-direction { both | in}
Enable 802.1x authentication with the wake-on-LAN (WoL) feature, and configure the port control as unidirectional or bidirectional.
authentication event
dot1x auth-fail vlan
dot1x critical (interface configuration)
dot1x guest-vlan6
Enable the restricted VLAN on a port.
Enable the inaccessible-authentication-bypass feature.
Specify an active VLAN as an 802.1x guest VLAN.
authentication fallback fallback-profile
dot1x fallback fallback-profile
Configure a port to use web authentication as a fallback method for clients that do not support 802.1x authentication.
authentication host-mode [ multi-auth | multi-domain | multi-host | single-host]
dot1x host-mode { single-host | multi-host | multi-domain}
Allow a single host (client) or multiple hosts on an 802.1x-authorized port.
authentication order
mab
Provides the flexibility to define the order of authentication methods to be used.
authentication periodic
dot1x reauthentication
Enable periodic re-authentication of the client.
authentication port-control { auto | force-authorized | force-un authorized}
dot1x port-control { auto | force-authorized | force-unauthorized}
Enable manual control of the authorization state of the port.
authentication timer
dot1x timeout
Set the 802.1x timers.
authentication violation { protect | restrict | shutdown}
dot1x violation-mode { shutdown | restrict | protect}
Configure the violation modes that occur when a new device connects to a port or when a new device connects to a port after the maximum number of devices are connected to that port.
show authentication
show dot1x
Display 802.1x statistics, administrative status, and operational status for the switch or for the specified port. authentication manager: compatibility with earlier 802.1x CLI commands
http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst2960x/software/15-0_2_EX/security/configuration_guide/b_sec_152ex_2960-x_cg/b_sec_152ex_2960-x_cg_chapter_010000.html#concept_6275D339A9074AC0BB06F872D7A54FBB -
Configuring SNMpv3 in switch 2960 and connect to cisco prime 6.3
hi
I configuring the parameters in the switch for snmp v3 and the cisco prime, but i don´t have any response
but, I configure snmp version1 this work
in the scree on the cisco prime, don´t appear this field´s to configure all parameters for snmpv3
any idea??
thanksHi ,
share your SNMPv3 config or I have attached the sample SNMPv3 config , kindly check or reconfigure it and see if it help
Thanks-
Afroz
***Ratings Encourages Contributors *** -
Switch 2960 IOS boot fixing problem
I have a prolem .when I change the IOS from rommon I try to reload the switc but he stopped and not complet it,s boot as show..
I tried the ios latest and old also, even same problem
Loading "flash:c2960-lanbasek9-mz.122-50.SE5.bin"...@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@@
File "flash:c2960-lanbasek9-mz.122-50.SE5.bin" uncompressed and installed, entry point: 0x3000
executing...
Switch uptime is 13 seconds
cisco WS-C2960-24PC-L (PowerPC405) processor (revision G0) with 65536K bytes of
memory.
Processor board ID FCQ1521Y4UG
Using driver version 1 for media type 1
Base ethernet MAC Address: 20:37:06:8a:e0:00
Xmodem file system is available.
The password-recovery mechanism is enabled.
Initializing Flash...
mifs[2]: 0 files, 1 directories
mifs[2]: Total bytes : 3870720
mifs[2]: Bytes used : 1024
mifs[2]: Bytes available : 3869696
mifs[2]: mifs fsck took 1 seconds.
mifs[3]: 8 files, 3 directories
mifs[3]: Total bytes : 27998208
mifs[3]: Bytes used : 9243136
mifs[3]: Bytes available : 18755072
mifs[3]: mifs fsck took 5 seconds.
...done Initializing Flash.
done.
Loading "c2960-lanbasek9-mz.150-2.SE2.bin"...c2960-lanbasek9-mz.150-2.SE2.bin: n
o such device
Error loading "c2960-lanbasek9-mz.150-2.SE2.bin"
Interrupt within 5 seconds to abort boot process.
Loading "flash:/c2960-lanbasek9-mz.122-50.SE4.bin"...@@@@@@@@@@@@@@@@@@@@@@@@@@@
File "flash:/c2960-lanbasek9-mz.122-50.SE4.bin" uncompressed and installed, entr
y point: 0x3000
executing...
Restricted Rights Legend
Use, duplication, or disclosure by the Government is
subject to restrictions as set forth in subparagraph
(c) of the Commercial Computer Software - Restricted
Rights clause at FAR sec. 52.227-19 and subparagraph
(c) (1) (ii) of the Rights in Technical Data and Computer
Software clause at DFARS sec. 252.227-7013.
cisco Systems, Inc.
170 West Tasman Drive
San Jose, California 95134-1706
Cisco IOS Software, C2960 Software (C2960-LANBASEK9-M), Version 12.2(50)SE4, REL
EASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2010 by Cisco Systems, Inc.
Compiled Fri 26-Mar-10 09:14 by prod_rel_team
Image text-base: 0x00003000, data-base: 0x01400000
Initializing flashfs...
Using driver version 1 for media type 1
ifs[3]: 0 files, 1 directories
mifs[3]: Total bytes : 3870720
mifs[3]: Bytes used : 1024
mifs[3]: Bytes available : 3869696
mifs[3]: mifs fsck took 0 seconds.
mifs[3]: Initialization complete.
mifs[4]: 8 files, 3 directories
mifs[4]: Total bytes : 27998208
mifs[4]: Bytes used : 9243136
mifs[4]: Bytes available : 18755072
mifs[4]: mifs fsck took 0 seconds.
mifs[4]: Initialization complete.
...done Initializing flashfs.
Checking for Bootloader upgrade.. not needed
POST: CPU MIC register Tests : Begin
POST: CPU MIC register Tests : End, Status Passed
POST: PortASIC Memory Tests : Begin
POST: PortASIC Memory Tests : End, Status Passed
POST: CPU MIC interface Loopback Tests : Begin
POST: CPU MIC interface Loopback Tests : End, Status Passed
POST: PortASIC RingLoopback Tests : Begin
00:00:08 UTC Mon Mar 1 1993: Unexpected exception to CPUvector 200, PC = 8A26E0
-Traceback= 8A26E0 651700 64A3F8 64B458 64C008 64C4C8 4F32E8 101C2A0 101C338 BCA
4C8 BCA734 1098AE4 108F5B4
Writing crashinfo to flash:/crashinfo_ext/crashinfo_ext_5
=== Flushing messages (00:00:11 UTC Mon Mar 1 1993) ===
Buffered messages:
Queued messages:
Cisco IOS Software, C2960 Software (C2960-LANBASEK9-M), Version 12.2(50)SE4, REL
EASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2010 by Cisco Systems, Inc.
Compiled Fri 26-Mar-10 09:14 by prod_rel_team
Machine Check Exception (0x0200)!
ESR: 0x00000000, BESRA: 0x00000000, BESRB: 0x00000000, BEAR: 0x00000000
CPU Register Context:
Vector = 0x00000200 PC = 0x008A26E0 MSR = 0x00029230 CR = 0x39033033
LR = 0x00651700 CTR = 0x006516F0 XER = 0xC0000010
R0 = 0x00651700 R1 = 0x01FAFDA8 R2 = 0x00000000 R3 = 0x00000000
R4 = 0x7C0000A4 R5 = 0x00000000 R6 = 0x00000000 R7 = 0x00000000
R8 = 0xFFFFFFFF R9 = 0x01D40000 R10 = 0x7C0000A4 R11 = 0x01472004
R12 = 0xE59C0800 R13 = 0x00110000 R14 = 0x01FAFDF8 R15 = 0x00000001
R16 = 0x01FAFDFA R17 = 0x01FAFDF8 R18 = 0x00000001 R19 = 0x00650000
R20 = 0x0144DED8 R21 = 0x00000000 R22 = 0x00000578 R23 = 0x00000001
R24 = 0x019F0000 R25 = 0x00000000 R26 = 0x00000000 R27 = 0x00000000
R28 = 0x00000000 R29 = 0x00000000 R30 = 0x0000000F R31 = 0x00000001
Stack trace:
PC = 0x008A26E0, SP = 0x01FAFDA8
Frame 00: SP = 0x01FAFDB0 PC = 0x008A26D4
Frame 01: SP = 0x01FAFDB8 PC = 0x00651700
Frame 02: SP = 0x01FAFDD0 PC = 0x0064A3F8
Frame 03: SP = 0x01FAFDF0 PC = 0x0064B458
Frame 04: SP = 0x01FAFE90 PC = 0x0064C008
Frame 05: SP = 0x01FAFEC0 PC = 0x0064C4C8
Frame 06: SP = 0x01FAFEE0 PC = 0x004F32E8
Frame 07: SP = 0x01FAFEE8 PC = 0x0101C2A0
Frame 08: SP = 0x01FAFF00 PC = 0x0101C338
Frame 09: SP = 0x01FAFF20 PC = 0x00BCA4C8
Frame 10: SP = 0x01FB0028 PC = 0x00BCA734
Frame 11: SP = 0x01FB0030 PC = 0x01098AE4
Frame 12: SP = 0x00000000 PC = 0x0108F5B4
Switch uptime is 13 seconds
cisco WS-C2960-24PC-L (PowerPC405) processor (revision G0) with 65536K bytes of
memory.
Processor board ID FCQ1521Y4UG
Using driver version 1 for media type 1
Base ethernet MAC Address: 20:37:06:8a:e0:00
Xmodem file system is available.
The password-recovery mechanism is enabled.
Initializing Flash...
mifs[2]: 0 files, 1 directories
mifs[2]: Total bytes : 3870720
mifs[2]: Bytes used : 1024
mifs[2]: Bytes available : 3869696
mifs[2]: mifs fsck took 0 seconds.
mifs[3]: 10 files, 3 directories
mifs[3]: Total bytes : 27998208
mifs[3]: Bytes used : 9521664
mifs[3]: Bytes available : 18476544
mifs[3]: mifs fsck took 5 seconds.
...done Initializing Flash.
done.
Loading "c2960-lanbasek9-mz.150-2.SE2.bin"...c2960-lanbasek9-mz.150-2.SE2.bin: n
o such device
Error loading "c2960-lanbasek9-mz.150-2.SE2.bin"
Interrupt within 5 seconds to abort boot process.
Loading "flash:/c2960-lanbasek9-mz.122-50.SE4.bin"...@@@@@@@@@@@@@@@@@@@@@@@@@@@
File "flash:/c2960-lanbasek9-mz.122-50.SE4.bin" uncompressed and installed, entr
y point: 0x3000
executing...
Restricted Rights Legend
Use, duplication, or disclosure by the Government is
subject to restrictions as set forth in subparagraph
(c) of the Commercial Computer Software - Restricted
Rights clause at FAR sec. 52.227-19 and subparagraph
(c) (1) (ii) of the Rights in Technical Data and Computer
Software clause at DFARS sec. 252.227-7013.
cisco Systems, Inc.
170 West Tasman Drive
San Jose, California 95134-1706
Cisco IOS Software, C2960 Software (C2960-LANBASEK9-M), Version 12.2(50)SE4, REL
EASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2010 by Cisco Systems, Inc.
Compiled Fri 26-Mar-10 09:14 by prod_rel_team
Image text-base: 0x00003000, data-base: 0x01400000
Initializing flashfs...
Using driver version 1 for media type 1
ifs[3]: 0 files, 1 directories
mifs[3]: Total bytes : 3870720
mifs[3]: Bytes used : 1024
mifs[3]: Bytes available : 3869696
mifs[3]: mifs fsck took 0 seconds.
mifs[3]: Initialization complete.
mifs[4]: 10 files, 3 directories
mifs[4]: Total bytes : 27998208
mifs[4]: Bytes used : 9521664
mifs[4]: Bytes available : 18476544
mifs[4]: mifs fsck took 0 seconds.
mifs[4]: Initialization complete.
...done Initializing flashfs.
Checking for Bootloader upgrade.. not needed
POST: CPU MIC register Tests : Begin
POST: CPU MIC register Tests : End, Status Passed
POST: PortASIC Memory Tests : Begin
POST: PortASIC Memory Tests : End, Status Passed
POST: CPU MIC interface Loopback Tests : Begin
POST: CPU MIC interface Loopback Tests : End, Status Passed
POST: PortASIC RingLoopback Tests : Begin
00:00:08 UTC Mon Mar 1 1993: Unexpected exception to CPUvector 200, PC = 8A26E0
-Traceback= 8A26E0 651700 64A3F8 64B458 64C008 64C4C8 4F32E8 101C2A0 101C338 BCA
4C8 BCA734 1098AE4 108F5B4
Writing crashinfo to flash:/crashinfo_ext/crashinfo_ext_6
=== Flushing messages (00:00:11 UTC Mon Mar 1 1993) ===
Buffered messages:
Queued messages:
Cisco IOS Software, C2960 Software (C2960-LANBASEK9-M), Version 12.2(50)SE4, REL
EASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2010 by Cisco Systems, Inc.
Compiled Fri 26-Mar-10 09:14 by prod_rel_team
Machine Check Exception (0x0200)!
ESR: 0x00000000, BESRA: 0x00000000, BESRB: 0x00000000, BEAR: 0x00000000
CPU Register Context:
Vector = 0x00000200 PC = 0x008A26E0 MSR = 0x00029230 CR = 0x39033033
LR = 0x00651700 CTR = 0x006516F0 XER = 0xC0000010
R0 = 0x00651700 R1 = 0x01FAFDA8 R2 = 0x00000000 R3 = 0x00000000
R4 = 0x7C0000A4 R5 = 0x00000000 R6 = 0x00000000 R7 = 0x00000000
R8 = 0xFFFFFFFF R9 = 0x01D40000 R10 = 0x7C0000A4 R11 = 0x01472004
R12 = 0xE59C0800 R13 = 0x00110000 R14 = 0x01FAFDF8 R15 = 0x00000001
R16 = 0x01FAFDFA R17 = 0x01FAFDF8 R18 = 0x00000001 R19 = 0x00650000
R20 = 0x0144DED8 R21 = 0x00000000 R22 = 0x00000578 R23 = 0x00000001
R24 = 0x019F0000 R25 = 0x00000000 R26 = 0x00000000 R27 = 0x00000000
R28 = 0x00000000 R29 = 0x00000000 R30 = 0x0000000F R31 = 0x00000001
Stack trace:
PC = 0x008A26E0, SP = 0x01FAFDA8
Frame 00: SP = 0x01FAFDB0 PC = 0x008A26D4
Frame 01: SP = 0x01FAFDB8 PC = 0x00651700
Frame 02: SP = 0x01FAFDD0 PC = 0x0064A3F8
Frame 03: SP = 0x01FAFDF0 PC = 0x0064B458
Frame 04: SP = 0x01FAFE90 PC = 0x0064C008
Frame 05: SP = 0x01FAFEC0 PC = 0x0064C4C8
Frame 06: SP = 0x01FAFEE0 PC = 0x004F32E8
Frame 07: SP = 0x01FAFEE8 PC = 0x0101C2A0
Frame 08: SP = 0x01FAFF00 PC = 0x0101C338
Frame 09: SP = 0x01FAFF20 PC = 0x00BCA4C8
Frame 10: SP = 0x01FB0028 PC = 0x00BCA734
Frame 11: SP = 0x01FB0030 PC = 0x01098AE4
Frame 12: SP = 0x00000000 PC = 0x0108F5B4
Switch uptime is 13 seconds
cisco WS-C2960-24PC-L (PowerPC405) processor (revision G0) with 65536K bytes of
memory.
Processor board ID FCQ1521Y4UG
Using driver version 1 for media type 1
Base ethernet MAC Address: 20:37:06:8a:e0:00
Xmodem file system is available.
The password-recovery mechanism is enabled.
Initializing Flash...
mifs[2]: 0 files, 1 directories
mifs[2]: Total bytes : 3870720
mifs[2]: Bytes used : 1024
mifs[2]: Bytes available : 3869696
mifs[2]: mifs fsck took 0 seconds.
mifs[3]: 12 files, 3 directories
mifs[3]: Total bytes : 27998208
mifs[3]: Bytes used : 9800192
mifs[3]: Bytes available : 18198016
mifs[3]: mifs fsck took 5 seconds.
...done Initializing Flash.
done.
Loading "c2960-lanbasek9-mz.150-2.SE2.bin"...c2960-lanbasek9-mz.150-2.SE2.bin: n
o such device
Error loading "c2960-lanbasek9-mz.150-2.SE2.bin"
Interrupt within 5 seconds to abort boot process.
Loading "flash:/c2960-lanbasek9-mz.122-50.SE4.bin"...@@@@@@@@@@@@@@@@@@@@@@@@@@@
File "flash:/c2960-lanbasek9-mz.122-50.SE4.bin" uncompressed and installed, entr
y point: 0x3000
executing...
Restricted Rights Legend
Use, duplication, or disclosure by the Government is
subject to restrictions as set forth in subparagraph
(c) of the Commercial Computer Software - Restricted
Rights clause at FAR sec. 52.227-19 and subparagraph
(c) (1) (ii) of the Rights in Technical Data and Computer
Software clause at DFARS sec. 252.227-7013.
cisco Systems, Inc.
170 West Tasman Drive
San Jose, California 95134-1706
Cisco IOS Software, C2960 Software (C2960-LANBASEK9-M), Version 12.2(50)SE4, REL
EASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2010 by Cisco Systems, Inc.
Compiled Fri 26-Mar-10 09:14 by prod_rel_team
Image text-base: 0x00003000, data-base: 0x01400000
Initializing flashfs...
Using driver version 1 for media type 1
ifs[3]: 0 files, 1 directories
mifs[3]: Total bytes : 3870720
mifs[3]: Bytes used : 1024
mifs[3]: Bytes available : 3869696
mifs[3]: mifs fsck took 0 seconds.
mifs[3]: Initialization complete.
mifs[4]: 12 files, 3 directories
mifs[4]: Total bytes : 27998208
mifs[4]: Bytes used : 9800192
mifs[4]: Bytes available : 18198016
mifs[4]: mifs fsck took 0 seconds.
mifs[4]: Initialization complete.
...done Initializing flashfs.
Checking for Bootloader upgrade.. not needed
POST: CPU MIC register Tests : Begin
POST: CPU MIC register Tests : End, Status Passed
POST: PortASIC Memory Tests : Begin
POST: PortASIC Memory Tests : End, Status Passed
POST: CPU MIC interface Loopback Tests : Begin
00:00:07 UTC Mon Mar 1 1993: Unexpected exception to CPUvector 1000, PC = 6DCA7
0
-Traceback= 6DCA70
Writing crashinfo to flash:/crashinfo_ext/crashinfo_ext_7
=== Flushing messages (00:00:09 UTC Mon Mar 1 1993) ===
Buffered messages:
Queued messages:
Cisco IOS Software, C2960 Software (C2960-LANBASEK9-M), Version 12.2(50)SE4, REL
EASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2010 by Cisco Systems, Inc.
Compiled Fri 26-Mar-10 09:14 by prod_rel_team
Programmable Interval Timer Exception (0x1000)!
SRR0 = 0x006DCA70 SRR1 = 0x00029230 SRR2 = 0x006533DC SRR3 = 0x00021200
ESR = 0x00000000 DEAR = 0x00000000 TSR = 0x8C000000 DBSR = 0x00000000
CPU Register Context:
Vector = 0x00001000 PC = 0x006DCA70 MSR = 0x00029230 CR = 0x39000033
LR = 0x0064B04C CTR = 0x0022E52C XER = 0xE0000010
R0 = 0x0064B04C R1 = 0x01FAFE58 R2 = 0x00000000 R3 = 0x0000002F
R4 = 0x01FC1E3C R5 = 0x00000000 R6 = 0x000001ED R7 = 0x00000000
R8 = 0x00000000 R9 = 0x019F0000 R10 = 0x00029230 R11 = 0x01D40000
R12 = 0x39000033 R13 = 0x00110000 R14 = 0x00BCA6D4 R15 = 0x00000000
R16 = 0x00000000 R17 = 0x00000000 R18 = 0x00000000 R19 = 0x00000000
R20 = 0x00000000 R21 = 0x00000000 R22 = 0x00000000 R23 = 0x00000000
R24 = 0x00000000 R25 = 0x00000000 R26 = 0x00000578 R27 = 0x00000000
R28 = 0x01D40000 R29 = 0x00000000 R30 = 0x01FAFEC8 R31 = 0x00000001
Stack trace:
PC = 0x006DCA70, SP = 0x01FAFE58
Frame 00: SP = 0x01FAFE80 PC = 0x01CA11B4
Frame 01: SP = 0x01FAFEB0 PC = 0x01DAC898
Frame 02: SP = 0x01FAFEC0 PC = 0x0064C29C
Frame 03: SP = 0x01FAFEE0 PC = 0x004F32A4
Frame 04: SP = 0x01FAFEE8 PC = 0x0101C2A0
Frame 05: SP = 0x01FAFF00 PC = 0x0101C338
Frame 06: SP = 0x01FAFF20 PC = 0x00BCA4C8
Frame 07: SP = 0x01FB0028 PC = 0x00BCA734
Frame 08: SP = 0x01FB0030 PC = 0x01098AE4
Frame 09: SP = 0x00000000 PC = 0x0108F5B4
Switch uptime is 12 seconds
cisco WS-C2960-24PC-L (PowerPC405) processor (revision G0) with 65536K bytes of
memory.
Processor board ID FCQ1521Y4UG
Using driver version 1 for media type 1
Base ethernet MAC Address: 20:37:06:8a:e0:00
Xmodem file system is available.
The password-recovery mechanism is enabled.
Initializing Flash...
mifs[2]: 0 files, 1 directories
mifs[2]: Total bytes : 3870720
mifs[2]: Bytes used : 1024
mifs[2]: Bytes available : 3869696
mifs[2]: mifs fsck took 0 seconds.
mifs[3]: 14 files, 3 directories
mifs[3]: Total bytes : 27998208
mifs[3]: Bytes used : 10084864
mifs[3]: Bytes available : 17913344
mifs[3]: mifs fsck took 5 seconds.
...done Initializing Flash.
done.
Loading "c2960-lanbasek9-mz.150-2.SE2.bin"...c2960-lanbasek9-mz.150-2.SE2.bin: n
o such device
Error loading "c2960-lanbasek9-mz.150-2.SE2.bin"
Interrupt within 5 seconds to abort boot process.
Loading "flash:/c2960-lanbasek9-mz.122-50.SE4.bin"...@@@@@@@@@@@@@@@@@@@@@@@@@@@
Thanks & Regards,
Srinivas. N.To solve this problem, please follow instruction carefully as follows:
1. go to cisco download website: http://software.cisco.com/download/release.html?mdfid=281231709&catid=268438038&rellifecycle=ED&release=12.2.50-SE5&softwareid=280805680&sortparam=
2. Copy the error loading message "c2960-lanbasek9-mz.150-2.SE2.bin" (without quotes). Paste it in the "search tab"
left side middle-corner then click the search zoom icon.
3. Locate your "c2960-lanbasek9-mz.150-2.SE2.bin" file. see below
All Releases
15.0
15.0SE
15.0.2-SE6(ED)
15.0.2-SE5(ED)
15.0.2-SE4(ED)
15.0.2-SE2(ED) <--click it
4. Download the the file
LAN BASE
c2960-lanbasek9-mz.122-55.SE9.bin <-- download this one.
Now you can proceed to the next step.
5. User HyperTerminal in sending files via xmodem
Step 1. Boot your switch into switch ROM mode. This typically involves holding down the STAT button on the front of the switch when plugging in the power.
Once you’ve booted your switch into Switch ROM mode you’ll be see the following dispatch;
Boot Sector Filesystem (bs) installed, fsid: 2
Base ethernet MAC Address: 00:00:00:00:00:00
Xmodem file system is available.
The password-recovery mechanism is enabled.
The system has been interrupted prior to initializing the
flash filesystem. The following commands will initialize
the flash filesystem, and finish loading the operating
system software:
flash_init
boot
switch:
Step 2. Once you’ve booted into Switch ROM mode you’ll need to initialize the flash file system by executing the flash_init command as shown below;
switch: flash_init
Initializing Flash...
flashfs[0]: 1 files, 1 directories
flashfs[0]: 0 orphaned files, 0 orphaned directories
flashfs[0]: Total bytes: 21592931
flashfs[0]: Bytes used: 19474880
flashfs[0]: Bytes available: 4224091
flashfs[0]: flashfs fsck took 8 seconds.
...done Initializing Flash.
switch:
Step 3 – OPTIONAL – If your image is corrupted you can format your flash file system by executing the format flash: command as shown below however this will delete your start-up configuration!!!
Switch: format flash:
Are you sure you want to format "flash:" (all data will be lost) (y/n)?y
flashfs[0]: 0 files, 1 directories
flashfs[0]: 0 orphaned files, 0 orphaned directories
flashfs[0]: Total bytes: 8440441
flashfs[0]: Bytes used: 2024
flashfs[0]: Bytes available: 8540274
flashfs[0]: flashfs fsck took 9 seconds.
Filesystem "flash:" formatted
Switch:
Step 4. To speed up the xModem file transfer speed you’ll need to set the console line BAUD rate to 115200 by executing the set BAUD 115200. If you do this you’ll need to disconnect your console session and change the serial line speed from 9600 to 115200. However if you do not set the BAUD to 115200 your file transfer can take up to 3 hours.
switch: set BAUD 115200
Step 5. Once setting the BAUD rate and reconnecting to the console line of your Cisco switch you’re ready to copy the IOS image via xmodem to the switch’s flash memory by executing the copy xmodem: flash:filename.bin and Then go to Hyper Terminal's menu bar, select Terminal, then send the file.
Select the file c2960-lanbasek9-mz.150-2.SE2.bin to send and select Xmodem as the protocol.
switch: copy xmodem: flash:c2960-lanbasek9-mz.150-2.SE2.bin
Begin the Xmodem or Xmodem-1K transfer now...
CCC
Starting xmodem transfer. Press Ctrl+C to cancel.
Transferring c2960-lanbasek9-mz.150-2.SE2.bin...
100% 12181 KB 6 KB/s 00:31:56 0 Errors
File "xmodem:" successfully copied to "flash:c2960-lanbasek9-mz.150-2.SE2.bin"
switch:
Step 6. Once the IOS image is copied into flash you’ll need to update the BOOT parameter by executing the set BOOT flash:filename.bin command as shown below;
switch: set BOOT flash:c2960-lanbasek9-mz.150-2.SE2.bin
Step 7. Once the boot parameter has been set you can now set the BAUD rate back to the default 9600bps by executing the command unset BAUD. Note that when doing this you’ll need to disconnect your current console connection and change the baud speed on your terminal emulator from 115200 back to 9600.
switch: unset BAUD
Step 8 is the last step which is to boot the switch and verify that the switch successfully boots the IOS image placed into flash from xMODEM. Execute the Boot command to load the IOS image specified in the boot parameter as shown below;
switch: boot
Loading "flash:/c2960-lanbasek9-mz.150-2.SE2.bin"...@@@@@@@@@@@@@@@@@@
WAIT UNTIL YOU SEE THE LAST MESSAGE
Press RETURN to get started!
CONGRATULATION!
DONE! -
Hello,
I have a switch which is powers up but does not work. I saw the below logs the I connected to to an interface.
Kindly assist.
POST: Inline Power Controller Tests : Begin
POST: inline power post failed for port 0
POST: inline power post failed for port 1
POST: inline power post failed for port 2
POST: inline power post failed for port 3
POST: inline power post failed for port 4
POST: inline power post failed for port 5
POST: inline power post failed for port 6
POST: inline power post failed for port 7
POST: inline power post failed for port 8
POST: inline power post failed for port 9
POST: inline power post failed for port 10
POST: inline power post failed for port 11
POST: inline power post failed for port 12
POST: inline power post failed for port 13
POST: inline power post failed for port 14
POST: inline power post failed for port 15
POST: inline power post failed for port 16
POST: inline power post failed for port 17
POST: inline power post failed for port 18
POST: inline power post failed for port 19
POST: inline power post failed for port 20
POST: inline power post failed for port 21
POST: inline power post failed for port 22
POST: inline power post failed for port 23
POST: Inline Power Controller Tests : End, Status Failed
POST: Thermal, Fan Tests : Begin
POST: Thermal, Fan Tests : End, Status Passed
POST: PortASIC Stack Port Loopback Tests : Begin
POST: PortASIC Stack Port Loopback Tests : End, Status Passed
POST: PortASIC Port Loopback Tests : Begin
POST: PortASIC Port Loopback Tests : End, Status Passed
POST: EMAC Loopback Tests : Begin
POST: EMAC Loopback Tests : End, Status Passed
Election Complete
Switch 1 booting as Master
Waiting for Port download...Complete
*Mar 1 00:00:1e Vlan1, changed state to down
*Mar 1 00:01:37.077: %SPANTREE-5-EXTENDED_SYSID: Extended SysId enabled for type vlan
*Mar 1 00:02:14.506: %SYS-5-CONFIG_I: Configured from memory by console
*Mar 1 00:02:14.736: %STACKMGR-5-SWITCH_READY: Switch 1 is READY
*Mar 1 00:02:14.736: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 1 has changed to state DOWN
*Mar 1 00:02:14.736: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 2 Switch 1 has changed to state DOWN
*Mar 1 00:02:15.014: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/1 can't be brought up because it failed POST in Inline Power test.
*Mar 1 00:02:15.014: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/2 can't be brought up because it failed POST in Inline Power test.
*Mar 1 00:02:15.014: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/3 can't be brought up because it failed POST in Inline Power test.
*Mar 1 00:02:15.014: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/4 can't be brought up because it failed POST in Inline Power test.
*Mar 1 00:02:15.014: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/5 can't be brought up because it failed POST in Inline Power test.
*Mar 1 00:02:15.014: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/6 can't be brought up because it failed POST in Inline Power test.
*Mar 1 00:02:15.014: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/7 can't be brought up because it failed POST in Inline Power test.
*Mar 1 00:02:15.014: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/8 can't be brought up because it failed POST in Inline Power test.
*Mar 1 00:02:15.014: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/9 can't be brought up because it failed POST in Inline Power test.
*Mar 1 00:02:15.014: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/10 can't be broug
*Mar 1 00:02:15.014: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/11 can't be broug
*Mar 1 00:02:15.019: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/12 can't be broug
*Mar 1 00:02:15.019: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/13 can't be broug
*Mar 1 00:02:15.019: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/14 can't be broug
*Mar 1 00:02:15.019: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/15 can't be broug
*Mar 1 00:02:15.019: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/16 can't be broug
*Mar 1 00:02:15.019: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/17 can't be broug
*Mar 1 00:02:15.019: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/18 can't be broug
*Mar 1 00:02:15.019: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/19 can't be broug
*Mar 1 00:02:15.019: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/20 can't be broug
*Mar 1 00:02:15.019: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/21 can't be broug
*Mar 1 00:02:15.019: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/22 can't be broug
*Mar 1 00:02:15.025: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/23 can't be broug
*Mar 1 00:02:15.025: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/24 can't be broug
*Mar 1 00:02:15.040: %STACKMGR-5-MASTER_READY: Master Switch 1 is READY
AnimHi Frederick,
POST: Inline Power Controller Tests : BeginPOST: inline power post failed for port 0POST: inline power post failed for port 1POST: inline power post failed for port 2POST: inline power post failed for port 3POST: inline power post failed for port 4POST: inline power post failed for port 5POST: inline power post failed for port 6POST: inline power post failed for port 7POST: inline power post failed for port 8POST: inline power post failed for port 9POST: inline power post failed for port 10POST: inline power post failed for port 11POST: inline power post failed for port 12POST: inline power post failed for port 13POST: inline power post failed for port 14POST: inline power post failed for port 15POST: inline power post failed for port 16POST: inline power post failed for port 17POST: inline power post failed for port 18POST: inline power post failed for port 19POST: inline power post failed for port 20POST: inline power post failed for port 21POST: inline power post failed for port 22POST: inline power post failed for port 23POST: Inline Power Controller Tests : End, Status FailedPOST: Thermal, Fan Tests : BeginPOST: Thermal, Fan Tests : End, Status PassedPOST: PortASIC Stack Port Loopback Tests : BeginPOST: PortASIC Stack Port Loopback Tests : End, Status PassedPOST: PortASIC Port Loopback Tests : BeginPOST: PortASIC Port Loopback Tests : End, Status PassedPOST: EMAC Loopback Tests : BeginPOST: EMAC Loopback Tests : End, Status PassedElection CompleteSwitch 1 booting as MasterWaiting for Port download...Complete*Mar 1 00:00:1e Vlan1, changed state to down*Mar 1 00:01:37.077: %SPANTREE-5-EXTENDED_SYSID: Extended SysId enabled for type vlan*Mar 1 00:02:14.506: %SYS-5-CONFIG_I: Configured from memory by console*Mar 1 00:02:14.736: %STACKMGR-5-SWITCH_READY: Switch 1 is READY*Mar 1 00:02:14.736: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 1 Switch 1 has changed to state DOWN*Mar 1 00:02:14.736: %STACKMGR-4-STACK_LINK_CHANGE: Stack Port 2 Switch 1 has changed to state DOWN*Mar 1 00:02:15.014: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/1 can't be brought up because it failed POST in Inline Power test.*Mar 1 00:02:15.014: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/2 can't be brought up because it failed POST in Inline Power test.*Mar 1 00:02:15.014: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/3 can't be brought up because it failed POST in Inline Power test.*Mar 1 00:02:15.014: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/4 can't be brought up because it failed POST in Inline Power test.*Mar 1 00:02:15.014: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/5 can't be brought up because it failed POST in Inline Power test.*Mar 1 00:02:15.014: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/6 can't be brought up because it failed POST in Inline Power test.*Mar 1 00:02:15.014: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/7 can't be brought up because it failed POST in Inline Power test.*Mar 1 00:02:15.014: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/8 can't be brought up because it failed POST in Inline Power test.*Mar 1 00:02:15.014: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/9 can't be brought up because it failed POST in Inline Power test.*Mar 1 00:02:15.014: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/10 can't be broug*Mar 1 00:02:15.014: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/11 can't be broug*Mar 1 00:02:15.019: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/12 can't be broug*Mar 1 00:02:15.019: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/13 can't be broug*Mar 1 00:02:15.019: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/14 can't be broug*Mar 1 00:02:15.019: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/15 can't be broug*Mar 1 00:02:15.019: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/16 can't be broug*Mar 1 00:02:15.019: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/17 can't be broug*Mar 1 00:02:15.019: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/18 can't be broug*Mar 1 00:02:15.019: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/19 can't be broug*Mar 1 00:02:15.019: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/20 can't be broug*Mar 1 00:02:15.019: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/21 can't be broug*Mar 1 00:02:15.019: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/22 can't be broug*Mar 1 00:02:15.025: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/23 can't be broug*Mar 1 00:02:15.025: %PLATFORM_ENV-3-ILP_PORT_POST_ERR: Gi1/0/24 can't be broug*Mar 1 00:02:15.040: %STACKMGR-5-MASTER_READY: Master Switch 1 is READY
try no shut on each interface and check it.
If still fails then, Please contact Cisco and try to get the appliance replaced. This swicth is dead, also raise a TAC case.
Reagrds
Dont forget to rate helpful posts.
Maybe you are looking for
-
Need to unlock an AT&T iPhone outside of the USA
Hi. First of all, I CALLED AT&T. They said they have a new policy now, in which I HAVE to have a valid AT&T phone number in order for them to be able to unlock my iphone4. They said this new policy was enforced by Apple. I'm not a residant of the USA
-
Repository is invalid after crash of the MDM Server in MDM 7.1
Hello, after a crash of our MDS the slave repository is invalid. When I tried to connect to the repository I am getting an error like Repository connect failed Error: The MDM repository is Invalid I tired to delete but I am not able to delete also. W
-
I erased some logic files ...can I get them back?
Hi all, I've erased some files by mistake and I want to recover them, I managed to recover all the audio files using 'Data recover II' but I can't find the logic sequences files... Can anyone help befor i spend lots of money with data recovery people
-
After adding a record in the database and the application is running, how do I update the tableview and display the record that I just include? Thanks
-
Yahoo has hijacked my web browser from Firefox and I can't get rid of it.
I have tried every way to change it, and my settings say Firefox is still my default browser yet it opens with AT&T/Yahoo as my search engine. I hate AT&T and have eliminated them completely from my life and don't want them as my search engine. I am