Switch Model SG302-08MP

Hi all, I have bought a SF 302-08MP Switch, thinking that this works like a Switch 2960, ie, I want to configure VLANs and ports TRUNK.
But when I connect via console shows me a series of menus that do not allow me to configure the ports to VLAN, or create a port in TRUNK mode.
I can do this kind of configurations in this model of Switch.?? .
Please, Any idea about this little problem ..??
Attach, sime screens of the configurator.
Regards.
Fernando

Hi flielguera, when you console and see only menu, this means the switch is on an old firmware 1.0.0.27. The CLI was introduced after the preliminary production release.
Please load the new firmware 1.3.5 software. This will require a boot code upgrade before loading the software.
Here's the download
http://software.cisco.com/download/release.html?mdfid=283019611&softwareid=282463181&release=1.3.5.58&relind=AVAILABLE&rellifecycle=&reltype=latest
To load the boot code, log in to the switch HTTP and you'll need to use TFTP.
https://supportforums.cisco.com/thread/2252523
-Tom
Please mark answered for helpful posts

Similar Messages

  • Conditionally  Switch Model Driven Lov In Jdev 12c problem

    Hi
    I this the following is a bug in Jdeveloper 12c
    I downloaded the  the demo application "How-to conditionally switch model driven LOV in ADF forms and tables"
    http://www.oracle.com/technetwork/developer-tools/adf/learnmore/index-101235.html
    and I open it using Jdeveloper 12c 12.1.2
    Click on the SOrdView  view object
    Click on the attribute tab and select "PaymentDetail"
    Click on List of values tab to see  the two defined LOVs
    now try to edit any one of these two LOVs by click on the pencil icon to open the edit LOV window
    On the Edit LOV window click on UI Hint to add or remove displayed attributes
    You will see that the shuttle list is dimmed . I mean disabled and this is the problem. Why it is disabled
    Is this a bug in Jdeveloper 12c?
    if it is not, how can i remove a displayed attribute from the list
    Please help

    Yes  I did
    In fact I know well how to make switch model driven LOV.
    In the very beginning I tried to do this task in my work and I find out this problem. So I downloaded the Demo to test it and I discovered that the demo too does not work.

  • Which switch model for more than 4 10G-Ports?

    we have a little network (100 clients, 1 VMware-Cluster with 2 Hosts, 1 Storage) and we want to replace old switches.
    we want to connect 4 cisco catalyst 2960X to core switch with 10G, and 4 2960X with 1G.
    Core switch is main routing instance for all.
    So we need following features for the core switch:
    - 8 10G-Ports
    - Redundancy
    - Static Routing
    Which is the cheapest model for core?
    Thanks!
    Martin

    I'm not sure if you get it "cheap" ...
    You could use:
    A stack of 2*WS-C3650-48TQ (each has 4*10GE)
    A stack of 2*SG500X-24 (each has 4*10GE)
    one or two SG500XG-8F8T (each has 8*10GE copper and 8*10GE SFP+)
    2) and 3) are from the SmallBusiness line of switches. So option 2) will probably the cheapest.
    Edit: Just looked at the stacking of the 500X. Seems that the 10GE-ports are used for stacking, so you would need four of them to get eicht usable 10GE-Ports. It still could be cheaper then the 3650, but probably not better ...

  • Switching model

    Hello!
    i'll Implement a lan fiberOptic Infrastructure.i'm a litle bit confused about the model of the switching in distribution mode;& for access mode.distance between the 2 distribution up to 600M.also i need to implement Etherchanel between the 2 distribution switch VIA fiber.also help me to determine the model that support GBIC fiber optic for distribution switch& for the access switch.
    10XS.
    aLI

    all of the Cisco switches that have a GBIC or SFP ports are suitable for these implementation, the decision on which switch depends on your budget and port density you want. The GBIC or SFP you will need based on the distance between switches (600 M) will need to be at least an LX/LH with fiber type as SMF as this combo have distance capabilities of 10 km. Anything less such as SX/LX/LH with cable type MMF have a ceiling distance of 550 M.
    Please rate helpful posts.

  • Question related to SFP, Fiber, and switches model Compatibility for Gigs Connections

    Hi everyone,
    I am in the middle of a project where we are receiving a 2gig Internet connection from a service provider. I need to connect this to a switch , my question is related to what sfp, switch would be the most compatible. I was thinking about a 3750 switch with sfp modules, but i am not sure if a SFP 1000 sx is enough as we are receiving a 2 gig connection via fiber then I would need to use a 10G module, with 10G sfps... mm well i am very confuse... can anyone help me please in your experience with a similar situation
    Thanks.

    Disclaimer
    The Author of this posting offers the information contained within this posting without consideration and with the reader's understanding that there's no implied or expressed suitability or fitness for any purpose. Information provided is for informational purposes only and should not be construed as rendering professional advice of any kind. Usage of this posting's information is solely at reader's own risk.
    Liability Disclaimer
    In no event shall Author be liable for any damages whatsoever (including, without limitation, damages for loss of use, data or profit) arising out of the use or inability to use the posting's information even if Author has been advised of the possibility of such damage.
    Posting
    A "2 gig" connection might mean a 10g logically limited to 2g, or it might mean the full duplex capacity of a gig link.
    The SFP+ ports on 10g 3750X modules will support either a gig or 10g transceiver.  The SPF ports, on either 10g or gig modules will only support gig.

  • Catalyst switch model 2950 series need ios image flash is unable to load.

     Hi, i'm in need of ios image for cisco 2950 series switch, because when its boots up its shows me a error message, Error loading "flash:c2950-i6q412-mz.121-13.EA1.bin"

    when switch gets reload its show me this message.....
    Xmodem file system is available.
    Initializing Flash...
    flashfs[0]: 1 files, 1 directories
    flashfs[0]: 0 orphaned files, 0 orphaned directories
    flashfs[0]: Total bytes: 7741440
    flashfs[0]: Bytes used: 1536
    flashfs[0]: Bytes available: 7739904
    flashfs[0]: flashfs fsck took 4 seconds.
    ...done initializing flash.
    Boot Sector Filesystem (bs:) installed, fsid: 3
    Parameter Block Filesystem (pb:) installed, fsid: 4
    Loading ""...: permission denied
    Error loading ""
    Interrupt within 5 seconds to abort boot process.
    Boot process failed...
    The system is unable to boot automatically.  The BOOT
    environment variable needs to be set to a bootable
    image

  • Switch Models & IOS Versions

    Hi
    I have been reading through the MARS manual and noticed that to manage switches they need to have a minimum IOS of 12.2. I have 14 2950's and 2 2940's which according to the cisco software advisor cannot upgrade to 12.2.
    Can i add these devices to MARS and what will be reported to MARS?

    You can add these devices to MARS but you would have to add them as custom devices since they are running an IOS not supported by MARS. In order to see events for the raw data you would have to develop customer parser.

  • Cisco switch model question

    Can someone tell what the -L,-S, or -E designation means on Cisco equipment? For example, looking at the
    WS-C3650-24TD-S ?

    Hi,
    According to your description, your question is about Cisco hardware. Here is the Microsoft TechNet Forum and mainly focused on product Windows Server System. I recommend you to ask the hardware vendor(Cisco) for official support. 
    Or you may reference link which Dave Patrick’s provided.
    Please Note: Since the web site is not hosted by Microsoft, the link may change without notice. Microsoft does not guarantee the accuracy of this information.
    Best Regards,
    Eve Wang
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Support, contact [email protected]

  • Two VLANs on one switch port?

    Currently we have the following
    Cat 4003 with VLAN trunking turned on to multiple switches. Each port in those exterior switches is assigned to a vlan(we have about 60 different vlans).
    What I would like to do is on those exterior switches have two vlans assigned to it.
    We'd like to create a single IP Phone VLAN(let's call it 999) that can span our entire enterprise and would have dhcp deployed on it.
    Each port is connected to an IP phone which has a 2 port switch in them. One port to the wall, one to the pc.
    The switch ports on those phones support vlan tagging
    How would setup an exterior switch to access 2 vlans that connect to 2 port switch on an IP phone?

    To facilitate ease of deployment, use VTP so that you can centrally create the vlans and propagate to each exterior switch. Now I believe you already do have a layer 3 engine or router that does routing between all these vlans. What switches are used on teh exterior ? This is to find out if voice vlan support is available.
    In cat switches, voice vlan is created using command,
    set port auxiliaryvlan vlan
    In IOS based switches,
    int fa0/1
    switchport mode trunk
    switchport trunk encap dot1q
    switchport trunk native vlan
    switchport voice vlan
    switchport priority cos extend 0
    or
    int fa0/1
    switchport mode access
    switchport access vlan
    switchport voice vlan
    I am not sure about support of voice/aux vlan in 4003. We will have check your other switch models/ software versions to determine support for this command.

  • How to set up VLAN for DATA and VOIP on SRW248G4P switch?

    Hi guys,
    I am totally new and was given this task to complete. I  really really need help.
    We are using one network 192.168.1.0
    Shared  with data and voip.
    CISCO C870, 5 switches LINKSYS SRW248G4P .
    The  email wrote:-
    On the Linksys switch;
    - create two  different VLANs one for voice and one for data.
    - put a firewall  between the two VLANs (between voice and data) and only enable certain  ports to flow to voice network (inbound tcp 8443 and ssh )
    What  should i do guys? I really need a dumb guide now.
    I know its simple for  you guys but i am not a smart IT fella. Whats the  step by step?

    If the switch is new or you have support on this, then you might try calling the support center.  Here is a link:
    https://www.myciscocommunity.com/community/smallbizsupport
    On the right hand side you can find links to the support center.
    Here is a link to the guide:
    http://www.cisco.com/en/US/products/ps9967/prod_maintenance_guides_list.html
    @ the bottom of this link you can find your switch model, you want the larger of the two.  In this guide it shows you how to create a second vlan.
    Will your router be the firewall between the two?
    Kindest regards,
    Andrew Lissitz

  • Domains usage in SQL Developer data MODELER

    Hi,
    I'm trying to understand how to use Domains in Oracle SQL Developer Data Modeler. We use version 3.1.3 .  before I used Toad Modeler  where domains are just part of your main design.
    Oracle data modeler has some different concept.
    let's assume I'm working on 2 designs:  DesignA and DesignB that include relational models.
    DesignA and Design B should use domains but list of domains in design A is very different than in design B.
    Default domain file is located on c: drive where SqlModeler is installed. It is obviously unacceptable , so I need to change Default System Type directory in preferences.
    And of course I want to have different domain directories for DESIGN A and DESIGN B.
    So when I open design A then I changed   Default System Type directory  let's say to x:\AAA.   Then i close design A and open Design B and change Default System Type directory to x:\BBB
    I checked folders AAA and BBB and they  have necessary XML files there:  defaultdomains.xml, defaultRFDBSSites and so on....
    Now questions:
    can I rename defaultdomains.xls to something else like AAAdomains.xls?  Domain administration can edit any domain file with any name , but how  can I associate certain domain file with my design?  My wish , when I open my design , then corresponding domain file will be open automatically.  Is it possible?
    If I open 2 designs in Sql Modeler and switch between designs  then corresponding domain files should be changed automatically as well.  Currently   I shouldn't forget to change default System Type directory every time when I switch models.  Is it the only way to handle it?
    Thanks
    vitaliy

    Hi Vitaliy,
    We use version 3.1.3
    I recommend always to use the latest version. If you don't want to use beta (DM 4.0 EA is out) you can use DM 3.3.
    Otherwise Oracle SQL Developer Data Modeler supports two types of domains:
    1) DM installation domains - those in file defaultdomains.xml
    2) Design level domains - they are stored in design directories and are visible to particular design only. They can be created in following ways:
    2.1 Manually - there is a property "Domains file" and you id it's not set "defaultdomains" domain will become design level domain and will be stored in file with provided name (without .xml extension)
    You can change later the file for design level domains, however you cannot change file for domain already in defaultdomains.xml.
    2.2 Using types to domains wizard you can generate design level domains
    2.3 Design level domains are created during import of  DDL files (controlled in preferences)
    2.4 You can import domains from specific file with domains using "File>Import>Domains" - you need to rename the source file if it's named defaultdomains.xml otherwise you'll get domains as installation domains
    If the list with domains is too long you can define  a list with preferred domains (or/and logical types) in "Preferences>Data Modeler>Model" and you can use shorter list in Table/Entity dialog if check "Preferred" check box next to "Type:" combo box.
    If I open 2 designs in Sql Modeler and switch between designs  then corresponding domain files should be changed automatically as well
    If you open 2 designs in one instance of DM they will use the same file with default domains i.e. you'll lose domains in one of design depending of setting for "system data type directory". You need to go with design level domains.
    Philip

  • CMTS uBR10012+RF-Switch N+1 Redundancy

    Hello,
    I need to know how to cabling a CMTS uBR10012 to a RF-Switch, when we are using four RF modules MC5X20S on the CMTS, to provide the 3+1 Redundancy.
    There is only one document about RF-Switch Cabling, but it describes the cabling only for ONE RF module (http://www.cisco.com/en/US/tech/tk86/tk804/technologies_white_paper09186a00802cd675.shtml)
    Please, everything about this issue is welcome.
    Thanks.

    What is the RFswitch type u r using?there are several RF switch types.If u r using uBR 3x10 RF switch, then I think the following link will provide you with a detailed sketch on cabling between this RF switch and the uBR10012 CMTS router.
    http://www.cisco.com/en/US/products/hw/cable/ps2929/prod_quick_installation_guide09186a00801da7d5.html.
    If this is not the RF switch model u use, then mention the name or model of ur RF switch type.Hence, I can provide u with a more appropriate document.

  • IDSM comand lines removal from 6509 vss switch

    Hi in our network we have implimented VSS withtwo Cisco 6509 -Eswitches. In these switch I have installed IDS module and following are my IDS configurations.
    intrusion-detection switch 1 module 4 management-port access-vlan 21
    intrusion-detection switch 2 module 4 management-port access-vlan 21
    intrusion-detection switch 1 module 4 data-port 1 trunk allowed-vlan 27,31
    intrusion-detection switch 2 module 4 data-port 1 trunk allowed-vlan 27,31
    intrusion-detection switch 1 module 4 data-port 1 autostate include
    intrusion-detection switch 2 module 4 data-port 1 autostate include
    Whenever I am restarting any node of my VSS the last two lines of the IDS configuration disappears and i need to reenter this manually.
    "intrusion-detection switch 1 module 4 data-port 1 autostate include
    intrusion-detection switch 2 module 4 data-port 1 autostate include"
    Following are my switch details.
    Switch model : WS-C6509-E
    SUP module : VS-S720-10G
    IDS module details : WS-SVC-IDSM-2
    IDS firmware : 7.2(1)
    IDS software : 6.2(3)E4
    I dont understand what causes this problem and during reboot of any VSS node why this configuration is not getting replicated to the othet node?
    Please help me...

    intrusion-detection switch 1 module 4 data-port 1 autostate include portfast
    set this command and check !!!!

  • Switch memory issue

       I have cisco 2960G switch. I got below error message on switch at some interval. 
     "Memory on switch has insufficient capacity or is malfunctioning."
    Switch model no: WS-C2960G-24TC-L
    SW version:  15.0(2)SE2
    SW image : C2960-LANBASEK9-M

    Use 15.0(2)SE4.

  • PXI-2570 switch capacitance

    I am generating a 5V peak, 400 kHz signal from an ARB (NI 5401) and inputting it into an amplfier with a gain of about 2, current draw around 400mA and an input voltage of 13V. I am taking the output of that amplifier and going straight into the PXI-2570 relay switches. From NO-1 and NO-2 I run the cable directly to DUT and get a ~2.5V peak-peak signal in which i should be getting a 10V peak-peak signal. If I take the output of the amplifier and without putting it through the relays I run it directly to the DUT i get the 10V peak-peak.
    My Question is why when i generate the 5V peak, 400 kHz signal and run it through the PXI-2570 and attach to the DUT do I see the large decrease in peak to peak voltage? Is there some internal capacitance of the relays that would be causing such a drop? The spec for PXI-2570 seems to be able to handle a 400 kHz signal?

    Murphyky,
    There’s one more test I’d like you to do with your setup.  Connect the signal from your amplifier, through the switch (modeled as 1 Ohm resistors), and then to a large load (not connected to your DUT).  If the signal shows up without attenuation, then we can confirm that the switch itself is working correctly. 
    Switches have a resistance listed in the specifications manual.    It is small, but it should still be considered in your design.  You’ve basically built a voltage divider with your circuit.
    A colleague of mine simulated your DUT in our Multisim circuit design software to see if we could determine the exact source of the signal attenuation in your DUT.  What sort of load are the two transformers driving?  We found that we could get a wide range of voltages across the DUT just by altering the load attached to the transformers.  See the images I’ve attached for reference:
    With the transformers driving 2 Megaohm loads:
    With one load reduced to 100 Ohms:
    Do you know the specifications of the amplifier that you're using?  Is it possible that it can't source the power required to drive the DUT.
    Let me know how the test with the switch goes.  If it passes, there is some other limitation in the circuit that is causing the signal attenuation.
    Good luck with everything.
    Regards,
    Jared R.
    Precision DC Product Support Engineer
    National Instruments

Maybe you are looking for

  • Design view greyed out

    Hello I have this css file and i can only view the code, when I try to click on the design view its greyed out. This wasnt the case last week when I could view it fine. Can anyone help me? Thanks

  • IMovie at 270mbps - Cost and upgrade ?

    I have 10.3.9 and because I want to play with uncompressed digital I have been told I must upgrade software because iMovie only handles 25mbps. Thus I am looking for the lowest cost way to do it. I am having 6 hours of home movies scanned into pure u

  • HP Laserjet pro 400 m451dn

    My printer keeps cancelling the print jobs, randomly. it's does not matter how big a print job is, I may get 50 pages printed of 160 or 1 of 8I do not get any error message, just printer states "cancelling" and status of printer is "error-send to pri

  • Autodiscover on Android Unchecks SSL?

    Testing autodiscover to Exchange 2007 over mobile data network on Android Galaxy S6 and everything is nearly working, except that when it goes through the autodiscover process, it unchecks the "Use SLL" checkbox and then fails (as we require SSL); if

  • Acquisition vidéo lente et enregistrement défectueux...

    Bonjour à tous, Je me permets de me tourner vers vous car j'avoue ne pas avoir de solution à mon problème, malgré de nombreuses et infructueuses recherches. Tout d'abord, je tourne sous labview 8.5 et j'ai téléchargé les versions d'évaluation de Visi