Switch with 6 SFP

Can anyone suggest me any Switch which will have minimum 12 10/100/1000T port and min 6 SFP for SX transiever or combo port?

No fixed configuration switch exist with such configuration requirements. However, you can use any module switch and pick the appropriate line card that will meet your requirements. an example of modular switch are Cat4000 and Cat6000.
Please rate helpful posts.

Similar Messages

  • Connecting two Nexus switches with link

    Hi,
    I would like to connect two nexus switches with a link. Like one c5020 and one c5548p. How do i need to configure the ports at both the switches which will be joined with a fiber cable.
    For MDS switches such links becomes E-port and fabric is merged. Not sure what happenes at the Nexus swictches. Any input will be appreciated.
    Thanks,

    Do you have fc modules in each nexus? If so, they act much like the MDS 9148. All ports should be default auto speed and auto switchport mode. Insert fc-sfp's and a regular multimode fc cable between them. Default mode is fc switch.
    If that doesn't work, configure the mode on each port as E.
    Once done, the fc switch portion of each nexus will merge.
    Dave

  • Where is the 300 series switch with 48 gigabit ports and PoE?

    Love the 300 series but surprised that Cisco did not put out a 48 port model with gigabit and PoE.  Would love to hear from Cisco on the reasoning behind that and if there are any plans to introduce one?  Given that gigabit and VoIP is the future at many companies it only makes sense.

    The switches use the SFPs to link to each other. The SG500 has ports for 1G or 5G and the SG500X has 10G ports. Whichever port you select will be the speed at which the switches pass traffic and stack control information. These same ports can be 'reclaimed' if you were to set the switch to stand alone mode. I have put a chart below which details the ports you can use and the speed of these ports.
    Header 1
    Header 2
    Header 3
    Header 4
    Header 5
    Units in Stack
    SG500X
    SG500X
    SG500
    SG500
    Stack Port Name
    S1,S2-XG
    S1,S2-5G
    S1,S2
    S3,S4
    Stack Port Speeds
    10G/1G
    1G/5G
    1G
    1G/5G

  • Trying to interconnect Catalyst 3750 with cwdm sfp module

    hi,
    I try to interconnect 2 Catalyst 3750 switch use cwdm sfp fiber module.
    If just plug in, there is no link between 2 switchs.
    What's the procedure to make this?
    Thanks

    you have 2 options with CWDM at the moment. the first option is to use any or all to the 8 wavelenght SFPs: CWDM-SFP-1470= (gray) thru CWDM-SFP-1610= (brown)
    with passive multiplexers (MUX) as described here:
    http://www.cisco.com/en/US/products/hw/modules/ps5455/products_data_sheet09186a00801a557c.html
    or
    In the off chance you have only a single strand of fiber available, you would choose:
    1000BASE-BX10-D AND 1000BASE-BX10-U SFP FOR SINGLE-FIBER BIDIRECTIONAL APPLICATIONS
    as described here:
    http://www.cisco.com/en/US/products/hw/modules/ps5455/products_data_sheet0900aecd8033f885.html
    Overall, CWDM is a cost effective method of building a Metro-Ethernet LAN / SAN by providing a single pair of single mode fiber the ability to support 8 wavelengths. You can mix and match these wavelengths with 1Gb Ethernet or 2Gb FiberChannel as needed.
    rate if helpful
    thanks,

  • SGE2010 problem with 1000baseSX SFP

    Hi guys,
    I need help in using the four gigabit sfp ports in the SGE2010. As i understand it, these ports labeled G1 to G4 are actually shared ports for ports 23-24 and 47-48. I tried inserting a 1000Base-sx (MGBSX1) to one of these SFP ports but it wont GO UP...port's status is always down, eventhough the port's LED lighted up. What could be the problem here? I made sure that all the posts involved are not used, except for the SFP port i need.  I'm trying to connect it to a 3com 4500 switch with 1000Base-sx module also. Their connection uses a  62.5/125 multimode fiber with distance less than 200 meters. I made sure that all vlan configuration are correct on both side.
    Is there a special procedure in managing these SFP ports?
    Thank you in Advanced!
    Zero

    Hi Zero,
    Thanks for participating in the community. My name is Nico Muselle fro Cisco Sofia STAC.
    Have your tried fixing the port speeds on both sides to 1 Gbps and disable auto-negotiation ?
    Best regards,
    Nico Muselle
    Sr. Network Engineer - CCNA

  • Half Duplex/100M problem on 2960 switch with GLC-GE-100FX

    We have a 2960-24TC switch with GLC-GE-100FX SFP interface converter. We connected the switch to another switch through fiber, one end was GLC-GE-100FX and the other end was a 100/FULL ATI media converter. Both switches could talk to each other. The problem was the GLC-GE-100FX interface running at 100M/half duplex status and we couldn't change the port configuration. Is there a way to fix this problem? Your help would be much appreciated.

    Using show interface command. It shows half duplex. It's a new design on Cisco 2960-24TC switches, the Giga uplink ports are dual purposed. When I plugged GLC-GE-100FX SFP interface converter and connected it to a media converter, it showed half duplex. There's no way I could change the speed and duplex under that configuration.

  • Using Catalyst 3550 Switch with Linksys Home Router and Cable Internet

    I've about pulled what little hair I have out of my head on this one, and need some configuration help.
    I have a Cisco Catalyst 3550 switch with five Windows 7 desktops, an Avaya PBX and five Avaya IP phones attached.  All of these devices are on a 192.168.0.0/24 subnet, and are communicating properly.  I will refer to this as network # 1. I also have SEPARATE network, we'll call network # 2, using AT&T ADSL service and a Netgear 4-port/wireless router/ADSL modem combo device, which is functioning properly with a couple of other Windows 7 desktops over its own wired Ethernet network, using DHCP, and also on a 192.168.0.0/24 subnet.  I thought it would be a simple integration, just plugging one of the 3550's ports to one of the DSL router's ports, in order to give the five Windows 7 desktop computers on network # 1 internet access via the DSL modem. Guess I was wrong.  When I connect the two switches together, although I get a good connectivity (green lights on both ports) and am able to ping the DSL router's gateway address (192.168.0.252) from network # 1's computers, the computers on network # 1 cannot access the internet. Also, the working computers on network # 2 lose their internet access as long as the two switches are connected together. I am not a Cisco guru, but there's got to be a way to make this scenario work.  Can someone provide me with a 3550 configuration that will allow me to extend my internet service from network # 2 on the DSL router to my 3550 switch and their computers?  Here's what I am looking for:
    INTERNET ---> ADSL MODEM ---> NETGEAR ROUTER ---> CISCO 3550 SWITCH ---> NETWORK DEVICES WITH INTERNET ACCESS

    The Netgear router is probably what's doing the natting. Is the 3550 configured for routing or is it straight L2? If you have the 3550 configured as L3, then it's going to be easy to do what you want. Just add a static route on the Netgear to point the subnet that it doesn't know about to the 3550. For example, if the Netgear is addressed at 192.168.1.1 and the Cisco 3550 is addressed at 192.168.1.2, but it also knows about the 192.168.0.0/24 (separate vlan), then you would put a static route on your Netgear for 192.168.0.0/24 to go to 192.168.1.2.
    The way that I would do it is to create a separate vlan on the 3550 and assign an address to it. Once you do that, make the port that the other switch connects to an access port of that vlan. (It would need to be on the same subnet as the existing equipment.) All of your devices would use it as a default gateway and then you would do the rest as above. You could also use RIP between the Netgear and Cisco if you can't do static routing.
    HTH,
    John

  • After installing an update I am no longer able to hear sound out of my speakers. A red light comes on where the headphone jack is. I have already attempted to trip to switch with a wooden toothpick in the headphone jack but have not had luck.

    after installing an update I am no longer able to hear sound out of my speakers. A red light comes on where the headphone jack is. I have already attempted to trip to switch with a wooden toothpick in the headphone jack but have not had luck.

    Have you gone into system prefs nad made sure that the headphone port is set to audio out. And not audio in.
    Also make sure that you are selecting built in speakers for your audio output.
    If that does not fix it try doing a Pram reset.
    Shut your mac down.
    Press the startup button.
    Hold down the following keys. Command Option P and R. Wait till you hear the chime 2 times. Then let go. See if that fixes it.

  • Toggle switches with if else

    I am trying to toggle various switches based off of others and am wondering how I can go about this. For example, if switch A is on, B should toggle off. If I toggle B on, A should toggle off. Any help in doing this would be appreciated. Thanks.

    Thank you for an easy question..... 
    There's a mode in the Switch options that allows you to create a single switch with two channels, where only one will be on.
    - cj
    Measurement Computing (MCC) has free technical support. Visit www.mccdaq.com and click on the "Support" tab for all support options, including DASYLab.

  • Change a 3560 Switch with Lifetime Waranty

    A simple question:
    Our client has 3560X Switches with a limited lifetime warranty. The Cisco Partner with whom they had the contract before bought the equipment, and they did not end up on good terms. One of the devices died the other day. My question is - how do we replace it now?
    Thanks

    I wish... here is the answer I got from TAC: "in this case there is nothing we can do to replace it as per Cisco policies and procedures customer has to engage his reseller for support."
    So disappointing... Now I need to call the client and tell them they need to throw the lifetime warranty switch away and buy a new one... 

  • HDMI switching with YV box - help?

    I am now in the unfortunate position of having a TV with only one HDMI input but currently have two boxes (YouView and NowTV) that output HDMI. The one scart input is used by the DVD player and I'm aware of scart-switch problems where YV boxes are concerned too.
    I bought a Duronics HDMI auto-switcher, it has three inputs and one output. I connected it up and the NowTV box displayed its bouncing logo fine. I switched on the YV box and got a pink screen. I tried unplugging the NowTV box from the mains, unplugging the HDMI lead etc. Cycling through the inputs using the manual switch - still the same pink screen, turned box on-off etc.
    Has anyone managed to use a HDMI switcher and if so how or which one and if it does work, does it always work without a problem? 
    For info: I have a BT supplied box (the first one they sent out, Humax ..), power set to the quicker starting one (eco-mode: Low??)

    I use a Thor combined HDMI/Optical switch with the YV box with no problem. Occasionally see a flash of pink when it switches then it settles down.
    Does this happen if you switch first before turning on the YV box (does your auto-switcher let you manually override to do this)?
    Have you re-tried plugging the HDMI lead direct into the TV as it maybe just a co-incidence this started happening when you introduced the switch?
    One other thing I suggest you try is swapping the HDMI leads between the YV box and the Now TV device.

  • Operating a SG200-08 switch with case removed.

    I am going to be putting an SG200-08 (8 port switch) inside a 2U rackmount chassis.
    To enhance cooling I thought I would remove the outer case.
    Are there, or would there be any issues with using the switch with the cover removed?
    Thanks
    Glen

    Hi Glen, the first issue would be, the warranty is void and you're not entitled to any support. The second issue would be static electricity and environmental concerns. The third issue would likely be your property insurance.
    It is highly against recommendation to alter or modify these units.
    -Tom
    Please mark answered for helpful posts

  • Two Switches with same MAC+Priority running STP

    Hi
    what will happen if two switch with same MAC-ADDRESS and same STP priority will run STP , how will elect to the root bridge ???? how the STP process will handle this situation?
    thanx

    Well, first off, no two switches (or switchports) will have the same MAC (if they do, you're buying switches from the wrong, very bad place).
    Every port of the switch will have (at least) one MAC of it's own.
    Given the same priority for all switches/bridges on the LAN, the lowest switch/bridge MAC on the LAN will win as the root.
    VLANS take on the MAC of the administrative interface ("CPU"): i.e., xxxx.xxxx.5000, the first port (i.e., fa0/1) is xxxx.xxxx.5001, the second (fa0/2) is xxx.xxxx.5002, and so on
    If you do a "show interface", the MAC / bia is displayed in the second line.
    Good Luck
    Scott

  • Limit switches with MID-7604

    I am trying to integrate a forward and reverse limit switch with a linear actuator. I need the actuator to find the forward limit, offset from the switch enough the disengage the switch, stop there while another task is occuring, then retract to the reverse limit, and finally offset from the reverse switch enough to disengage the switch.
    I'm able to get this procedure to work one time through when the driver is just turned on, but after it's gone through the procedure more than once, the actuators no longer offset. I'm defining the offset amount in Measurement and Automation Explorer. It appears that the "find reference" VI longer finds the forward and reverse limits after the first time because if I probe the output of the "check reference" VI, the value is false even when the actuator has stopped on the limit switch.
    Is there something I need to clear after each cycle? Any suggestions would be great. 

    Hello,
    Do you have any data acquisition board? You will need one to capture the signal and process in labview.
    If you don´t have one, you can search in NI website. The NI has several models.
    Best regards.

  • Can we have 3 way vertical toggle switch, with unstable position at top, neutral position in center and stable position at bottom. the shape of the switch should be same as that of vertical toggle switch.

    can we have 3 way vertical toggle switch, with unstable position at top, neutral position in center and stable position at bottom. the shape of the switch should be same as that of vertical toggle switch.

    Avon,
    You've asked the same question and received several replies in two recent threads here and here.
    Rather than start a third thread, it would be best to just respond in one of them with details as to your problems with the proposed solutions (e.g. use of picture control).
    =====================================================
    Fading out. " ... J. Arthur Rank on gong."