Synchroniz​ing x-series pxie 6358 and 6363

Hi,
I have 2 pieces of PXIe-6358 at the moment and planning to extend the kit by 3 pieces of PXIe-6363 and to perform HW-timed analog readings on all devices synchronously.
Using all AI channels of the PXIe-6363s, the max. sampling freq. is going to be 31.25 kHz I guess. Thus the sampling freq. of the PXIe-6358s have to be set to 31.25 kHz as well. To enforce the synchronisation with low jitter I think all sample clocks should be tied to a reference clock - OnBoardClock for example. The question is: how can I synchronise these X-series cards to a same reference clock and to the same frequency? Can somebody please suggest how it is done efficiently.
Thanks,
Krivan

Synchronizing DSA, S Series, and X Series Devices With a Single NI-DAQmx Task
NI-STC3 Timing and Synchronization Technology
Synchronization Explained
Christian

Similar Messages

  • How do I restrict access to the RT Series PXI Controller via its FTP server?

    The RT Series PXI Controllers run an FTP server, so I can view files on the controller over the Internet wtih a Web browser. I can also download and upload files with a Web browser. How can I instruct the FTP server to give access only to specified, trustworthy FTP clients?

    It is possible to "Lock" the controller from the Measurement and Automation Explorer program. The password you set when locking the controller (which prevents others from making configuration changes to the controller while running) is the same password that controls access to the FTP server. When the controller is unlocked, anyone who can access the PXI controller's IP can read, write, and delete files on the FTP server. When locked, anyone can read data from the FTP server, but only when logged in with the lock password will you have access to write or delete data.
    For more information on locking your controller, see the user manual, MAX online help, or the following link.
    NI Developer Zone: Controlling Access to LabVIEW Real-Time PXI Targets

  • Separate MIGO Series for 103 and 105 Movement

    Hi Experts,
    Please confirm SPRO Setting to separate MIGO Number Series for 103 and 105 Movement Type.
    Please cofirm, whether it is possible.
    Matter Urgent.
    Ishu

    Hi,
    Material Document is at Client Level, you cannot separate based on the  movment type.
    Regards
    Rewrad Points if useful

  • HELP! I need to be able to remove power from a PXI chassis and replace a card without rebooting the whole system

    I do not have particulars on the controller, but I am sure it's an NI chassis
    and NI regular controller that has a serial cable leading back to the PC.
    I am making this PXI rack into a debug rack for instrument cards,
    so I need to be able to remove power from just the PXI chassis
    and then replace the card with another one
    or the same one and then turn the power back on and restart a
    diagnostic test on the card WITHOUT
    having to reboot the PC.
    Is there a PCIe bridge setup that would allow me to do this?
    Is there software that I need that can accomplish this?

    Yes
    The Chassi is a NI PXI 1045
    and the controller is a NI-PXI-8331
    Let me re-enumerate my requirements:
    Background:
    I have a number of NI cards as well as other manufactured cards in the system.
    One of these cards in the NI system is considered to be a UUT.
    That is, I am using the NI card cage system and other cards in the system to test a CARD
    during a manufacturing test of said UUT CARD.
    The UUT uses a PLX 9030 for it's PCI interfacing.
    This UUT is not designed for hot swap, and I do not bieleve it is plug and play.
    Requirement:
    1. I need to be able to shut off the chassis and remove the UUT when the test finishes, replace the tested UUT
    with a unknown UUT, re-apply power and then test the new UUT WITHOUT having to reboot the PC.
    I have tried several things, such as disabling the PCIe busses in the windows control panel, and then removing power
    replacing the UUT with the next one, re-applying chassis power and then re-enabling the bus and SOMETIMES it works.
    I need a very robust way to do this.
    I also bought a CHROMA PXI-52906-E extender card with bus switches on it, so that I can remove power to the UUT
    without shutting off the chassis. The card is supposedley designed so that when power is re-applied to the UUT, the necessary
    signals to boot the PXI PCI interface is conducted, but I think something else has to be written to the card's PCI registers.
    I am by no means an expert in PCI/PXI, 
    but I seem to have exhausted all of my reserach online in how to meet my requirements.
    Perhaps there is a way for the NI8331 controller to capture PCI configuration data to the card's on system boot,
    and then "replay it" to my UUT after I re-apply power to the UUT?
    Or perhaps PLX makes such a tool?
    Any ideas?

  • How to acquire data through multiple channels in parallel using PXI 6070 E, PXI 4071 and LabVIEW?

    Hi,
    I am using NI LabVIEW, NI PXI 4071, and NI PXI 6070E to measure current through a variable resistance. Now, I am using one channel from SCB-68, but I want to add another channel in parallel so that I can have two resistors instead of one that I cam measure current through them.
    I have attached a Pdf file showing the setup for hardware in use and LabVIEW code also.
    Can anyone look at these files and give me guide lines or ideas that can help me resolving this issue, please.
    Thanks in advance.
    Best Regards,
    Shaheen.
    Solved!
    Go to Solution.
    Attachments:
    IV copy for HS.vi ‏55 KB
    Layout of NI Cards.pdf ‏248 KB

    Your 4071 can only do one measurement at a time. Your DAQ cannot measure resistance either nor has it got any analogue inputs.
    However, you could use a multiplexer and multiplex your 4071 DMM. This wont give you simultaneous measurements but can acquire data one after the other, the speed is obviously dependent on the multiplexer you choose!
    Hope this helps.
    Beginner? Try LabVIEW Basics
    Sharing bits of code? Try Snippets or LAVA Code Capture Tool
    Have you tried Quick Drop?, Visit QD Community.

  • I want to upgrade my storage plan in icloud. Before that i want to know whether synchronization of data in my PC and data in one of the applications of ipad is possible through icloud or not

    I want to upgrade my storage plan in icloud. Before that i want to know whether synchronization of data in my PC and data in one of the applications like "phone drive" of ipad is possible through icloud or not?

    The Photos app doesn't currently support subfolders, it only has the one level of folder/album. You will either need to change your folder structure on your computer to be just one level, see if there is a third-party photo app in the store that copes with subfolders, or just make do. You can try leaving feedback for Apple : http://www.apple.com/feedback/ipad.html

  • Swapping hard drives between PXI-8115 and PXI-8105 won't boot up

    I have a test system running Windows XP on PXI-8105.  I've upgraded the entire test system for another project and need to upgrade my existing systems; the upgrade runs on Windows 7 and PXI-8115.  I have new hard drives with Windows 7 and the new test software which were loaded/configured/tested on a PXI-8115, but I need to retrofit the PXI-8105 with them.  This doesn't work.  Windows begins to boot but fails and tries over and over again.  In an effort to take the PXI-8105 off-line to troubleshoot, I replaced it with one of the PXI-8115 and the old (WinXP) drive.  This didn't boot up, either.
    Here's a summary of my situation:
    An old system has PXI-8105 running WinXP
    A new system has PXI -8115 running Win7
    A hard drive (with Win7) from the PXI-8115 won't boot on the PXI-8105
    A hard drive (with WinXP) from the PXI-8105 won't boot on the PXI-8115
    What is different between the two PXI controllers that keeps me from swapping hard drives?
    Jim
    You're entirely bonkers. But I'll tell you a secret. All the best people are. ~ Alice
    Solved!
    Go to Solution.

    A couple thoughts:
    1. Windows 7 probably works fine on a PXI-8105. Although NI never officially supported or shipped that configuration, I suspect that the default Windows 7 installation contains enough of the driver support needed to boot up.
    2. In general, Windows is not very tolerant of swapping hard drives between completely different systems, especially with Windows XP and prior. Consider whether just installing fresh and copying over what you need is faster than trying to do this, but if you must, I would suspect that Windows 7 would be more tolerant of the swap.
    3. As a debugging step, try pressing 'F8' during the boot process to launch the Windows boot menu and try safe mode or some of the other options.  More information here.
    4. If all else fails, Google is your friend here as there's nothing particularly specific about this being an NI product that you need to know when attempting this operation. Any information you find online about swapping hard drives between PCs should be relevant to your situation. Searching for 'swap hard drive to new computer windows 7' gave some useful hits on the first page. Beyond that, you can also look into using the 'sysprep' utility to try and clean the system and prepare for swapping to a new PC.

  • HT1657 I have just got a iPad yesterday and I'm having a problem  I have just bought a tv series in iTunes and downloaded it on to my iPad but every time I go to watch it it comes up (could not load movie) then takes me back to the episode list ? Can you

    I have just got a iPad yesterday and I'm having a problem
    I have just bought a tv series in iTunes and downloaded it on to my iPad but every time I go to watch it it comes up (could not load movie) then takes me back to the episode list ? Can you tell me how to solve this problem please

    Have a look at the following:
    http://itunes.apple.com/sg/app/quickoffice-pro-hd-edit-office/id376212724?mt=8&l s=1
    http://itunes.apple.com/sg/app/office2-hd/id364361728?mt=8&ls=1
    http://itunes.apple.com/sg/app/documents-to-go-premium-office/id317107309?mt=8&l s=1
    http://itunes.apple.com/sg/app/polaris-office/id513188658?mt=8&ls=1

  • I am having a problem where pdf files on the web (i.e., links in a Word doc) open after an extended time and only as gobbldygook ( a file containing a series of characters and letters that make no sense).  This also happens for another Mac user coworker

    Hi There:  I am having a problem where pdf files on the web (i.e., links in a Word doc) open after an extended time and only as gobbldygook ( a file containing a series of characters and letters that make no sense).  This also happens for another Mac user coworker in my office, while the PCs don't have this problem...  Any help/suggestions for a fix would be most appreciated! 

    Just adding more info - MacBookPro running 10.5.8 and using Safari as the browser.  The problem comes and goes - sometimes the linked Word files will open OK, n others its just a strring of crazy characters... 

  • Does the Modulation Toolkit support digitizers NI-PXI-5124 and NI-PCMCIA-5102?

    I am using a demonstration NI-PXI unit to determine if it will support the application I am trying to develop. I need to demodulate a signal and determine the Quasi-peak value of the demodulated signal. The Modulation Toolkit states that it works with the 100MHz class of digitizers. Does it also support the 20 MHz and the 200 Mhz class of digitizers (NI-PXI-5124 and NI-PCMCIA-5102)?

    Kent,
    The Modulation Toolkit is fairly robust. I believe that it will work fine with the 20 and 200 MS/s boards. However, these obviously have to stay towards the lower frequency end of the spectrum. The Modulation Toolkit is most powerful with NI's RF products and is designed to do so. However, as I said, I believe that since the MT stays mostly on the software side and does not care too much about hardware it will not care about where the signals are coming from and will work for you.

  • Installing the latest update on my iPad - error message saying the iPad couldn't synchronize because of an internal error, and then - error message (OxE8004017) when trying to save, and then (2003) when trying to restore - nothing works anymore

    Installing the latest update on my iPad - error message saying the iPad couldn't synchronize because of an internal error, and then - error message (OxE8004017) when trying to save, and then (2003) when trying to restore - nothing works anymore - On my iPad the only thing I see is a connector cord to iTunes and nothing else.
    What can I do  ???

    Same issue for me, recently I started having issues with apps no longer being able to access my Facebook account. But the iPad Facebook account settings will not accept my password, even though the Facebook app and Safari can access my account fine. The only significant events I recall that have occurred that may have triggered this have been that via my Facebook account I killed off a lot of so called authorised connections and I changed my user name, but still have the same email address and password.
    I have tried just about every solution put forward on the net, short of a factory restore, back to new, on my iPad.
    I have also; deleted my iCloud account, deleted the Facebook app and account, deleted Safari data.
    One would think that after I have deleted my account from the iPad that it would ask for both username/email address and password, but it only asks for password, so the username is still stored somewhere that I am unable to delete.
    I also see that no one seems to have been able to get an answer from Apple. So I'm guessing they have absolutely no idea themselves.
    I am hesitant to put my username on Facebook back to what it was as Facebook only give you a few chances to change your username, then you are locked.
    I have iOS 7.1.1 installed.
    I did have a lot of respect for Apple and their devices as they just worked, but they are becoming tarnished by ignoring what seems to be a growing issue.

  • Hi, i have downloaded peppa pig series using itunes, and have tried to sync them to my Ipad Mini and IPhone 5, however it is not working it states "videos from your Itunes libary can not be copied to 'ipad' because they can not be played on this Ipad.

    I have downloaded Peppa Pig series using Itunes and have tried to sync the tv programme to both my Ipad Mini and IPhone 5.  However neither work saying that 'videos from Itunes Libary can not be copied to 'ipad' because they can not be played on this I Pad.  I have downloaded the HD episodes is this my problem or do i need to download a 'video watching' app?  Please help we are going away next week and the episodes were to help keep my toodler occupied on the plane.  thank you

    The error you received kinda looks like the one in this article: http://support.apple.com/kb/ts4223
    But the iPhone 5 and the iPad mini should support HD videos. 
    What I would try is downloading the movies directly to your iPad mini or your iPhone.  You will want to do this when connected to Wi-Fi, but you can follow these steps in this article: http://support.apple.com/kb/HT2519
    I hope that helps!

  • How can I synchronize 'Notes' on both my iPad and iMac?

    How can I synchronize 'Notes' on both my iPad and iMac? I have checked the boxes for Notes on iCloud and Yahoo.

    Go to Settings > Messages > Receive At. Use the same Apple ID. Make sure the phone numbers/email addresses you want to receive messages at are checked.

  • URGENT: PXI-1033 and DAQmx problem

    I bought new laptop with Express Card slot Dell Inspiron 6400. I have PXI-1033 with integrated MXI bridge, Express Card 8360 and PXI-modules: PXI-6251, 6115, 5114 and 4071. I installed drivers 8.3 and plugged in PXI modules into PXI-1033. I first power up PXI-1033 and than power up laptop (with Express Card in it). Laptop can not start, again can not, blue window, and at last start. In MAX is listed PXI chassis with bridge and all modules, but mx is not listed and I can not use it from LabVIEW. What is the problem?

    Hi,
    To clarify, do the PXI modules show up under DAQmx devices?  What color is the Link LED on the 1033?  Do the cards all show up in Windows Device Manager correctly?  Also, are you able to power on the laptop successfully now every time, or does is have trouble booting each time you try and start it up?
    Have you inspected the MXI cable for bent pins or any visible damage?
    Thanks!
    Adam W
    Applications Engineering
    National Instruments

  • Error -1074118625 with PXI-4071 and PXI-2527

    When using the LabVIEW IVI drivers for PXI-4071 and PXI-2527, I receive an error -1074118625 in TestStand.  The sequence initializes the MUX, init DMM, connects the MUX, waits for debounce, and then upon reading from the DMM, I receive this error.
    Error: niDMM Read Waveform (waveform data).viExplanation could not be found for the requested status code.
    Verify that the requested status code is correct.
    [Error Code: -1074118625, User-defined error code.]
    This sequence of events is successfully used multiple times elsewhere in the TestStand.  This error does not appear in any knowledgebase article nor in any help.  Any explanation would be greatly appreciated.
    Solved!
    Go to Solution.

    I found this with google that seems like it might apply:
    http://digital.ni.com/public.nsf/allkb/A593DEBFD86A69C68625727900748EEC