System delta pull config
Hi,
I get an error when testing my BW system connection that the delta pull might not be configured for my system. where and how do I configure system delta pull in the portal?
Thank you!
Kr,
hilde
Hi Hilde,
I know the delta pull mechanism only from Universal Worklist (see SAP Library section <a href="http://help.sap.com/saphelp_nw04s/helpdata/en/eb/101fa0a53244deb955f6f91929e400/frameset.htm">Enabling Delta Pull Mechanism</a>). There you can specify the period of time after which the UWL should refresh the cached work items retrieved from a certain backend system.
To configure the delta pull settings of a system used by UWL go to:
=> System Administation => System Configuration => Universal Worklist & Workflow => Universal Worklist Administration
Select your system and click the "edit" button to see the current configuration.
Best regards,
Martin
Similar Messages
-
The backend of system SAP_R3_UWL is not configured for optimized delta pull
Hi All,
I used the below to configure the Enabling Delta Pull Mechanism in UWL.
http://help.sap.com/saphelp_nw04s/helpdata/en/eb/101fa0a53244deb955f6f91929e400/frameset.htm
uwl_service user created and assigened role SAP_BC_UWL_SERVICE with the help of Note 873932 - Additional note on authorization of uwl_service user. But still i am having the below error:
The backend of system SAP_R3_UWL is not configured for optimized delta pull
Thanks,
AnumitHi Sean,
I have done everything that is mensioned in the Help.
Thanks,
Anumit -
UWL / Delta Pull Configuration
Hello,
I am trying to configured delta pull in UWL, but when I create a new SYstem in UWL administration, I get the message:
Could not verify if the backend of system WADCLNT200 is configured for optimized delta pull.
I need to implement delta pull because we have a lot of performance problem with UWL.
My portal is 700 SP18 and backend system 6.40
Any idea¿?
Thanks and Regards
NoemíHello Juan
I am facing performance problem with UWL so I am configuring delta pull.
I created rol SAP_BC_UWL_SERVICE and uwl_service in the backend system WAS 640. I also created jobs following instructions in http://help.sap.com/saphelp_nw04s/helpdata/en/eb/101fa0a53244deb955f6f91929e400/frameset.htm.
Also created RFC Destination in Visual Admin of portal
When I amd creating the UWL System WADCLNT200 in the portal, I try to put in field "Delta Pull Channel Refresh Period (in Seconds):" the value 60, but when I saved the system I get the message:
Could not verify if the backend of system WADCLNT200 is configured for optimized delta pull
If I edit again the System WADCLNT200 created, there is not value 60 on Delta Pull Channel Refresh Period (in Seconds).It is empty. I am unable to save the value 60.
My question is if you know how can i solved the message "Could not verify if the backend of system WADCLNT200 is configured for optimized delta pull".
Thanks in advanced for your help.
Kind Regards
Noemní -
Configuration issue on two items for system center 2012 config manager
My first issue was at the beginning of the install trying to extend the AD schema for system center 2012 config manager version 7.5.1561.0. The
path is missing for SMSSetup\Bin\x64\ to execute
Extadsch.exe is not on my disc. There is only a x86 and 64 bit folder with no bin.
Second issue when creating configuration manager connector. Error connecting to the database. So i went to my sqlserver and checked the permissions on the account I did notice that there are no smsdbrole_extract role permissions. Did I miss a step somewhere
along the way? On a side not that this is an instance and not under the default place. Also, i am using sql 2008 R2 version.OK, nothing wrong with that per se, but it has nothing to do with ConfigMgr. Also, ConfigMgr is not a "module", it's a distinct product unto itself with its own unique requirements and dependencies that is also architecturally completely different. So,
there's nothing to uninstall to install ConfigMgr. Also, I hope you're not trying to install these products on the same server. That is OK for a small lab environment, but nothing more. Even then, I wouldn't do it since its never something you'd do in production.
As mentioned, each product has its own unique dependencies with no true overlap.
Jason | http://blog.configmgrftw.com -
Trying to update my apps system is pulling up someone else's account info no mine n I'm logged in
trying to update my apps
system is pulling up someone else's account info
not mine n I'm logged in
mac app storeYou are most welcome. It would be best to delete those apps and re-purchase them (or re-download them if they were free) under you own Apple ID. That way you will be able to continue to update them, and will also be able to access them under your Purchase history if you need to download them again, or download them to another device.
Cheers,
GB -
Hello,
I am wondering if I might have done something incorrectly. I am new to lo cockpit and had to create a custom datastore. I did the steps below and then ran deltas from that point on. Only the first delta pull after my initial load had duplicates in it (about 2000 out of 8749 records for BF datasource). The delta job was scheduled hourly.
Any insight would be greatly appreciated.
Lynda
Steps for Loading Raw Materials from ECC to BW - 3/25/2009
1. ECC/SRM/BW u2013 lock out users u2013 6 pm
2. ECC - delete 03 setup tables u2013 SBIW
3. ECC - insure all delta queues do not contain anything for 2lis_03_BF or 2LIS_03_UM
(rsa7, SMQ1, LBWQ)
4. ECC - Stop V3 jobs for inventory u2013 SM37 u2013 if any exist
5. ECC u2013 fill setup tables u2013 SBIW for material movements and revaluations
(1085, 1101, 1103, 1104, 1200, and 1201 company codes )
6. ECC u2013 SM37 u2013 check for RMCBNEUA (MSEG) pull and RMCBNERP (BSEG pulls)
for successful completion
7. BW - Run Init W/out data transfer u2013 sets delta pointer
8. BW - Run Full Repair for 2lis_03_bf and 2lis_03_um datasources to ZGDMVTIM
9. Run deltas - got 0 records
10. ECC u2013 schedule V3 jobs using LBWE
11. Unlock Users
on 3/27/2009 - first real delta pull occurred . Out of 8749 BF records, 2000 were duplicates. Did it have anything to do with the full repair?closing this question - opened up another similar question.
-
Hi,
Can anyone please help me in creating the Custom Search box with below mentioned functionality
"The search box will allow up to 60 alphanumeric characters.User can input a minimum of 1 character and the system will pull back an exact match on the sequence entered"Hi Pradeep,
Find the complete JQuery AutoComplete function with along with different events in it like focus, select, open and close. You can modify this code as per your requirement.
$("#ddlSearchTextBox").autocomplete({
source: function (request, response) {
var getUrl = "<site URL>";
$.ajax({
url: getUrl,
type: "GET",
contentType: "application/json; charset=utf-8",
dataType: "json",
data: {
featureClass: "P",
style: "full",
maxRows: 10
dataFilter: function (data, type) {
return data.replace(/\\'/g, "'");
success: function (data) {
response($.map(data.d, function (result) {
return {
label: result.Last_Name + ", " + result.First_Name,
value: result.id
focus: function (event, ui) {
$("#ddlSearchTextBox").val(ui.item.label);
return false;
minLength: 1,
select: function (event, ui) {
$("#ddlSearchTextBox").val(ui.item.label);
return false;
open: function () {
$("#ddlSearchTextBox").removeClass("ui-corner-all").addClass("ui-corner-top");
close: function () {
$("#ddlSearchTextBox").removeClass("ui-corner-top").addClass("ui-corner-all");
Let us know if you need any further.
Thanks, Shakir | Please 'propose as answer' if it helped you, also 'vote helpful' if you like this reply. -
After "wadm pull-config" the Admin gui still shows deployment pending
After doing a manual edit of my webserver 7.0u3 instance config files I run wadm with the pull-config subcommand. After the command successfully completes I go into the admin gui and it shows that I have a deployment pending. Why is this? Doesn't this command sync the instance config with the config-store?
pull-config command pulls the configuration from the node to the config-store and then the user is supposed to deploy the configuration using deploy-config command to propagate those changes to the other instances if any.
pull-config information from Web Server CLI reference:
http://docs.sun.com/app/docs/doc/820-4842/pull-config-1?a=view -
Inconsistencies data between ODS and RSA3 in SAP system (delta problem??)
Hi everyone,
I have a problem in my SAP BW production system. There is inconsistencies data between ODS (using tcode LISTCUBE) and Datasource in SAP system (tcode RSA3).
I'm using Datasource: 0FI_GL_10 and ODS: 0FIGL_O10.
In SAP system (using RSA3):
GL Account: 1202012091
Comp Code : 5400
Bus Area: 5401
Fiscal Year :2008
Period: 07
Accum Balance : $0
Credit Total: $350
Debit Total: $350
Sales : $0
And in ODS (using ListCube):
GL Account: 1202012091
Comp Code : 5400
Bus Area: 5401
Fiscal Year :2008
Period: 07
0BALANCE : $350 (it should be $0,shouldn't it? )
0CREDIT: $0 (it should be $350,shouldn't it? )
0DEBIT: $350
0SALES: $350 (it should be $0,shouldn't it?)
I have tried these :
1. Check if there is a start routine / routine or not in transfer or update rules....and...i get nothing
2. Check the data using tcode FBL3N..but the data is ok
And then i tried to trace the process chain and find error on delta infopackage which pull these data
Date
07.30.2008 : 231141 records --> error (ODS activation) --> request has deleted forever
07.31.2008 : 2848 records --> error (ODS activation) --> request has deleted forever
08.01.2008 : 135679 records --> error (ODS activation) --> request has deleted forever
08.02.2008 : 135679 records --> successfull repeat delta action
From 30 July until 1 August there is an error on delta infopackage because
fail to activate ODS (No SID found for value 'RIM' of characteristic 0UNIT). On 2 August someone delete the red requests and repeat the delta and success. Is there any possibilities that this problem arise because of this? If this the cause, how to bring back 2848 and 231141 records which has deleted?
Thank you and Regards,
-Satria-Hi everyone,
I have solved my problem. I executed my infopackage again (selection condition using GL Account which have wrong amount) with update mode 'Full update' and choose Scheduler > Repair Full Request and tick the checkbox.Thank you.
Regards,
-Satria- -
Some client systems not pulling down updates
Hi,
I recently pushed out the all the March Patch Tuesday updates and I've got around 11 systems that are reporting as compliant when I review the status of the deployment, but are systems that haven't actually pulled down or installed the updates from the deployment.
Strangely the systems show up as Active in the SCCM 2012 console and have current (within the last 4 hours or so) active times. So it seems the SCCM client components are working correctly.
The thing all these systems appear to have in common is that in the WindowsUpdate.log I see the following lines:
2015-03-23 04:32:32:148 2216 16d8 COMAPI ---------
2015-03-23 04:32:32:148 2216 16d8 COMAPI -- END -- COMAPI: Search [ClientId = CcmExec]
2015-03-23 04:32:32:148 2216 16d8 COMAPI -------------
2015-03-23 04:32:32:959 2216 a18 COMAPI WARNING: ISusInternal::GetUpdateMetadata2 failed, hr=8007000E
Reviewing the WindowsUpdate.log I can see the CCMExec process talking to my SCCM 2012 server but then I get the error above and no updates appear to get pulled down.
I've tried rebooting the systems to see if that resolves the issue but it doesn't. Also what is strange is that these systems have all been working fine in the past. So something appears to have gotten messed up but I'm not sure what?
Any ideas?
Thanks in advance,
NickJust to update - I followed the steps to resolve the problem that were mentioned in the following thread
https://social.technet.microsoft.com/Forums/en-US/cf8fbe28-714d-49d3-b2ce-5cc5f6f79c63/some-clients-not-updating-reporting-compliant-hr8007000e-error-in-windowsupdatelog?forum=configmanagersecurity
Namely I did:
Clean up WSUS - I had over 18000 expired/unneeded updates in my WSUS server. I used the SQL script from the following post:
http://blog.coretech.dk/kea/house-of-cardsthe-configmgr-software-update-point-and-wsus/
It took over two days to delete all the updates in batches of 2000
I also plan to add a weekly scheduled job with the WSUS Server Cleanup process PowerShell script they provide to keep my WSUS server clean
Index the WSUS database - I used the SQL Script provided in the following post
https://gallery.technet.microsoft.com/ScriptCenter/6f8cde49-5c52-4abd-9820-f1d270ddea61/
I also plan to add a scheduled job to run this weekly
After I made these changes my Windows 7 x86 clients that hadn't pulled down the latest March updates pulled them down.
I also ran the batch file they provided
Net stop wuauserv
Sc config wuauserv type= own
Net start wuauserv
Just in case on these machines.
Thanks for the help on this one. -
Pulling configs off of VPN Concentrator 3020
I am currently trying to set up a site-to-site VPN for a vendor on an ASA. The vendor has an existing connection through our out-dated VPNC3020. After doing some research on the web, I could not find a way to pull the configs off of the 3020 to expedite the process of setting up the VPN on the ASA. Is there a way to view the configuration on the 3020 of is it strictly GUI based?
Nobody with experience who can help me a little bit??
-
BW system open for config for RSA1 display
Hi
Our developers have been told by another company that there is a bug in BW3.5 (fixed in 7) whereby the system needs to be open for config in SCC4 to be able to view certain data.
This is in RSA1 - under InfoProvider they have a Holiday Entitlement - Quote Transactions item which when double clicked brings up a screen showing Update Rules information - Status, Data Fields, Type, Srce Fields. There is also a 'Create Start Routine' button, or, if one is already created, a 'Start Routine' display, and other information they require - more detailed information on the characteristics, Process Chain maintenance and InfoPackage maintenance.
With the system closed - they cannot see any of this. Update Rules and the 'Start Routine' buttons are not present.
We are not comfortable having the Live system open and have asked why they cannot do this in Development, as they insist they are not making any changes - they just need to display this information. They say it is required for debugging, and they have to debug in this system, as the debugging depends on the data - which is different in Prod than it is in Dev.
Does this stand up? Are there other ways they can access this information?
We tried Note 337950 - Queries (and other objects) cannot be edited - but this hasn't helped.
If there is a SAP note that does confirm this is a 'bug' and the system does indeed need to be open then please could someone point me in it's direction??
Many thanks
RossSorry for not replying for so long... this one kinda went off the radar whilst there were some more important issues.
Thanks for the responses... Eric, our SCC4 settings were the same - i.e. system pretty much closed - and they couldn't see anything. Only by changing in SCC4 did they then get the warning message about changing obecjts - which you can bypass - and then you're in and can see everything.
We're on support package 17; BI_CONT is on 12.
The roles the users have been developed by their authorisations team... do you think it could be an auths issue? Surely it wouldn't make any difference though if you opened the system in SCC4?
EmJay - thanks, but this only pops up as per above when the system is open for config. Else you don't get the message at all.
Cheers
Ross -
Hi,
I need to capture data at runtime through CJ20n before saving.
I have used Validation at Network Header level and used the function module 'CO_BO_OPR_OF_ORDER_GET' to get activities.I need to get delta data,
So I check on the field VBKZ.
However if I change one activity, for all the activities
i get VBKZ = 'U'.
I want to capture only those activities that are actually changed.
Any idea?
Thanks & Regards,
VanitaVanita,
It makes sense if SAP marks all activities updated even if you change one activity because activities have relationship among them and change in duration of one activity may change the scheduling of other activities too.
Inside the network header level validation, you could read the activities from database again. You can do it by reading table AFVC against routing number of network and blank SUMNR. It will give you all activities in one select statement. You can move the both data for one particular activity( from datbase and from function module) to two similar structures ( structure almost like AFVC but with out administrative information like last changed on, at, by etc etc). By comparing them, you can identify if aqctivity got changed.
If an activity was previously scheduled and now you change its duration or dates then SAP puts a system status NTUP. if you are just interested in activities with changed dates, you can go by system status change to NTUP.
I hope this helps.
PS - Please award the points if it helps. -
Hi, new to 10. I have a fully functional network using DNS. My sparc Solaris machine has a static address. Inside is fine but I can't get outside. The lan I'm on is behind a firewall and used a proxy for http. I can't seem to get the network config correct. Any pointer would be great. I have set the defaultrouter as my gateway. Also tried adding the proxy to the defaultrouter. Many combinations have been tried.
ThanksThanks for the reply. The network works except for the http proxy. I can ping other machines on the net both from the hosts file and through dns. I'm behind a firewall with an http proxy server. How to I configure my system to be able to use the proxy?
Thanks
again -
Php install: pull-config does not work
getting:
ADMIN3593: Unable to process config files
i have tried both in the command line and in the web gui.Filesystem size used avail capacity Mounted on
/dev/md/dsk/d102 20G 16G 3.1G 85% /
/devices 0K 0K 0K 0% /devices
ctfs 0K 0K 0K 0% /system/contract
proc 0K 0K 0K 0% /proc
mnttab 0K 0K 0K 0% /etc/mnttab
swap 9.2G 1.2M 9.2G 1% /etc/svc/volatile
objfs 0K 0K 0K 0% /system/object
fd 0K 0K 0K 0% /dev/fd
/dev/md/dsk/d302 16G 7.8G 7.8G 50% /var
swap 9.2G 7.0M 9.2G 1% /tmp
swap 9.2G 120K 9.2G 1% /var/run
/dev/md/dsk/d402 20G 6.2G 13G 32% /opt
/dev/dsk/c5t600A0B8000196A10000028AB4343D2D5d0s6
35G 24G 11G 70% /export/home
/platform/sun4u-us3/lib/libc_psr/libc_psr_hwcap1.so.1
20G 16G 3.1G 85% /platform/sun4u-us3/lib/libc_psr.so.1
/platform/sun4u-us3/lib/sparcv9/libc_psr/libc_psr_hwcap1.so.1
20G 16G 3.1G 85% /platform/sun4u-us3/lib/sparcv9/libc_psr.so.1
bash-3.00# swap -l
swapfile dev swaplo blocks free
/dev/md/dsk/d202 85,202 16 16780208 16780208
bash-3.00# prtdiag -v
System Configuration: Sun Microsystems sun4u Sun Fire V240
System clock frequency: 167 MHZ
Memory size: 8GB
==================================== CPUs ====================================
E$ CPU CPU
CPU Freq Size Implementation Mask Status Location
0 1503 MHz 1MB SUNW,UltraSPARC-IIIi 3.4 on-line MB/P0
1 1503 MHz 1MB SUNW,UltraSPARC-IIIi 3.4 on-line MB/P1
================================= IO Devices =================================
Bus Freq Slot + Name +
Type MHz Status Path Model
pci 66 MB pci108e,1648 (network)
okay /pci@1f,700000/network@2
pci 66 MB pci108e,1648 (network)
okay /pci@1f,700000/network
pci 33 MB isa/su (serial)
okay /pci@1e,600000/isa@7/serial@0,3f8
pci 33 MB isa/su (serial)
okay /pci@1e,600000/isa@7/serial
pci 33 MB isa/rmc-comm-rmc_comm (seria+
okay /pci@1e,600000/isa@7/rmc-comm@0,3e8
pci 33 MB pci10b9,5229 (ide)
okay /pci@1e,600000/ide
pci 66 MB scsi-pci1000,21 (scsi-2)
okay /pci@1c,600000/scsi@2
pci 66 MB scsi-pci1000,21 (scsi-2)
okay /pci@1c,600000/scsi
pci 66 MB pci108e,1648 (network)
okay /pci@1d,700000/network
pci 66 MB pci108e,1648 (network)
okay /pci@1d,700000/network
pci 66 PCI0 SUNW,qlc-pci1077,2312 (scsi-+
okay /pci@1d,700000/SUNW,qlc@1
pci 66 PCI0 SUNW,qlc-pci1077,2312 (scsi-+
okay /pci@1d,700000/SUNW,qlc@1,1
============================ Memory Configuration ============================
Segment Table:
Base Address Size Interleave Factor Contains
0x0 4GB 16 BankIDs 0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15
0x1000000000 4GB 16 BankIDs 16,17,18,19,20,21,22,23,24,25,26,27,28,29,30,31
Bank Table:
Physical Location
ID ControllerID GroupID Size Interleave Way
0 0 0 256MB 0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15
1 0 0 256MB
2 0 1 256MB
3 0 1 256MB
4 0 0 256MB
5 0 0 256MB
6 0 1 256MB
7 0 1 256MB
8 0 1 256MB
9 0 1 256MB
10 0 0 256MB
11 0 0 256MB
12 0 1 256MB
13 0 1 256MB
14 0 0 256MB
15 0 0 256MB
16 1 0 256MB 0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15
17 1 0 256MB
18 1 1 256MB
19 1 1 256MB
20 1 0 256MB
21 1 0 256MB
22 1 1 256MB
23 1 1 256MB
24 1 1 256MB
25 1 1 256MB
26 1 0 256MB
27 1 0 256MB
28 1 1 256MB
29 1 1 256MB
30 1 0 256MB
31 1 0 256MB
Memory Module Groups:
ControllerID GroupID Labels Status
0 0 MB/P0/B0/D0
0 0 MB/P0/B0/D1
0 1 MB/P0/B1/D0
0 1 MB/P0/B1/D1
1 0 MB/P1/B0/D0
1 0 MB/P1/B0/D1
1 1 MB/P1/B1/D0
1 1 MB/P1/B1/D1
============================ Environmental Status ============================
Fan Status:
Location Sensor Status
F0 RS okay
F1 RS okay
F2 RS okay
MB/P0/F0 RS okay
MB/P0/F1 RS okay
MB/P1/F0 RS okay
MB/P1/F1 RS okay
PS0 FF_FAN okay
PS1 FF_FAN okay
Temperature sensors:
Location Sensor Status
MB/P0 T_CORE okay
MB/P1 T_CORE okay
MB T_ENC okay
PS0 FF_OT okay
PS1 FF_OT okay
Current sensors:
Location Sensor Status
MB FF_SCSI okay
PS0 FF_OC okay
PS1 FF_OC okay
Voltage sensors:
Location Sensor Status
MB/P0 V_CORE okay
MB/P1 V_CORE okay
MB V_VTT okay
MB V_GBE_+2V5 okay
MB V_GBE_CORE okay
MB V_VCCTM okay
MB V_+2V5 okay
MB V_+1V5 okay
MB/BAT V_BAT okay
PS0 P_PWR okay
PS0 FF_POK okay
PS0 FF_UV okay
PS0 FF_OV okay
PS1 P_PWR okay
PS1 FF_POK okay
PS1 FF_UV okay
PS1 FF_OV okay
Keyswitch:
Location Keyswitch State
MB SYSCTRL NORMAL
Led State:
Location Led State Color
MB ACT on green
MB SERVICE off amber
MB LOCATE off white
PS0 ACT on green
PS0 SERVICE off amber
PS0 OK2RM off blue
PS1 ACT on green
PS1 SERVICE off amber
PS1 OK2RM off blue
HDD0 SERVICE off amber
HDD0 OK2RM off blue
HDD1 SERVICE off amber
HDD1 OK2RM off blue
HDD2 SERVICE off amber
HDD2 OK2RM off blue
HDD3 SERVICE off amber
HDD3 OK2RM off blue
=========================== FRU Operational Status ===========================
Fru Operational Status:
Location Status
MB/SC okay
PS0 okay
HDD0 present
HDD1 present
PS1 okay
================================ HW Revisions ================================
ASIC Revisions:
Path Device Status Revision
/pci@1f,700000 pci108e,a801 okay 4
/pci@1e,600000 pci108e,a801 okay 4
/pci@1c,600000 pci108e,a801 okay 4
/pci@1d,700000 pci108e,a801 okay 4
System PROM revisions:
OBP 4.22.23 2006/11/27 04:43 Sun Fire V210/V240,Netra 210/240
OBDIAG 4.22.23 2006/11/27 05:01
bash-3.00# fmadm faulty
STATE RESOURCE / UUID
-------- ----------------------------------------------------------------------
Maybe you are looking for
-
Error while creating a web proxy service using wsdl
Hi folks, In my use case I should create a web service proxy using the wsdl. While I am creating the web service proxy I am getting some error like the binding method does not have the SOAP extension. I am giving the error below for more clarity Caus
-
BAPI Check in BADI Implementation
Dear All, We have made an enhancement through BADI in ME21N / ME22N transaction like validating certain entries, in that I am checking the t-codes ME21, ME21N, ME22 and ME22N. If it fails then PO wonu2019t create and populate some messages. Now there
-
HT3965 Changing name on ipod touch 2nd gen
The name is grayed out on the ipod touch so I can't change it there. I don't see where to change it on the computer and I can't figure out how to put the new songs I bought onto the ipod. I liked the old itunes store better. This one is too confus
-
VERY URGENT: Msync not synching
Hi, I have a very urgent problem with MSync. I am able to do the initial synchronisation of my db onto the client and can see the table data on the client with MSql. However if I do any changes to data in either the server or the client then they are
-
I have a macbook pro, running OS X Yosemite. I plugged in a valid USB and it does not show in Finder? Is there another way to locate it?