System identifica​tion error 41263

hi...
can somebody please explain why i am getting an error "41263-The System Identification Toolkit cannot retrieve the data in system model because the model type you wire in is incompatible with the system model requirements. " while using model simulation vi to simulate an arx model i created using estimate arx model vi?

Hi ajaleelp,
Sorry for the delayed response on this, but I have a few questions for you.  Are you just receiving this error at run-time? Meaning you have no broken wires or anything, but the VI stopsat the model simulation VI?
Also, have you tried our example for model simulation? You can find it here:
C\program files\national instruments\labview [version]\examples\System Identification\Getting
Started\General.llb 
This actually uses the estimate arx and model simulation VIs. So, you should be able to see if that works, and then compare it to your system.
Hope this helps!
Chris Van Horn
Applications Engineer

Similar Messages

  • System identifica​tion for open loop unstable plant?

    Hello,
    I have been trying to use system identification on labview. My problem is that my plant is open loop unstable and none of the tutorials or examples I have found seem to cover this so I cannot get it to work. Does anyone have any suggestions as to how I should go about it? My plant has an RC servo so it needs a PWM signal to stimulate it.
    Thanks
    Adam

    adamkse wrote:
    I want to control my plant with lead/lag control but I do not know the plant model which makes this very difficult. I cannot theoretically calculate it because the information I need to obtain a numerical transfer function or state space model is unavailable.
    I have it controlled with PID at the moment but this is not ideal.
    I am trying to use the system identification toolkit to obtain a transfer function but I do not know what to do because the examples do not work for open loop unstable plants.
    Adam
    Ok Open loop unstable functions cannot be predictably controlled (hence the terms; open loop and unstable,)  Not being able to model the actions is a bit of a problem too.
    Somehow, someway you need to get some kind of model or some kind of feedback to either provide stability in the plant or close the loop.
    Adding hardware (sensors) is the most likely solution.
    tell me more about the plant, I do this kind of thing for a living, so I could offer some ideas. 
    Jeff

  • System Identifica​tion Assistant Signal Generator

    Hello,
    I am using a GW Instek power source to heat a graphite rod within a vacuum chamber.  I am detecting the temperature with a K type thermocouple connected to a thermocouple input module.  I have written a labview program with a PID and have everything running, yet i force tuned the PID. I would like to use the signal identification tools labview provides to identify the transfer function and model the process.  I have used the system identification assitant in attempting to send a step signal and acquire a response, yet I have been running into difficulties.  The only way I can perform a step function is to manually generate an output of a specified power and then measure the response, as the signal generator within the system identification software is not identifying the GW Instek PSW 30-108 power source. With manual input and importing both input and output data i am able to get a parametric model, yet the transfer function provide me PID values which are 5 orders of magnitude greater then the ones i am currently using. Ideally i would like to use the software to generate the signal and measure the response continuously rather then using data i collect through my program.  If possible, I would also be interested in perhaps directly integrating VI's to perform signal analysis directly into my process program.
    Problems and what I have done:
    I have the drivers for the power source and my process program recognizes the device yet system ident assist cannot find the hardware. I have attempted to creat a task in NI-MAX yet the hardware is also non-identifiable. 
    Port module input works with VISA and this is how my VI is communicating with the power source.
    Goals:
    I would like to use the system ident assist to generate power ouput and collect temperature input, and generate a process model, so that I may tune my PID more accuratly.
    Also, I may be interested in integrating VI's directly into my process program, yet I am new to the LV language...
    I have attached  my Labview program below.  I would like to thank you in advance for your time and look forward to responses.
    Cheers
    Attachments:
    Test1_RT.vi ‏186 KB

    Double post, for further Information see http://forums.ni.com/t5/LabVIEW/System-Identificat​ion-Assistant-w-o-NI-Signal-Generator/m-p/3014731#​...

  • RLS for system identifica​tion: problem in creating a signal + noise input.

    i have successfully implemented the RLS algorithm in labview, but i am having alot of trouble generating an input. at first i used a ptbypt sine input and wired it to my FIR Filter (win coeff ptbypt) and to my data queue (ptbypt) to generate U(n). When i plot the adjusted weights they give a perfect Sinc Function. 
    So, after this i add in a gaussian White noise VI (ptbypt) and add it's output with the output of the sine wave VI (ptbypt) and like before wire the output of the summation to the FIR Filter and the data queue point by point. The problem that is occurring is that my tap weights after becoming constant do not change. they are the same for when i enter the sine wave alone and when i enter the sine wave with the gaussina white noise, tap weights are same. they only change when i change the low cutoff of the FIR FIlter.
    its would be very much appreciated if someone may help me solve this problem i am having. I made the RLS (for system identification) as Final Year Engineering Project.

    the input is a sine wave , the sine wave passes through a system which incorporates a noise in it (we say the noise incorporated by the system is the Gaussian white noise) the corrupted input enters the system , the filter weights are adjusted by the algo, and a sine waveform is extracted filtering the noise.
    what kind of LTI system. Can you please elaborate? and i cant switch to LMS my project is RLS.

  • System identifica​tion miso models

    Hi,
       I want to know is it possible to identify the MISO and MIMO models using system identification toolkit?
       I m using fieldpoint 2010. The program is running very slow inside the fieldpoint. so is it possible to divide the program in such a way that few compuations(which are less critical)  run inside the  computer and few inside the fieldpoint?
    Regards,
    Sai

    Hi Ruser,
     LabVIEW System Identification toolkit provides SI Convert to Models of CDT VI to convert a model you created in the LabVIEW System Identification Toolkit into a transfer function, zero-pole-gain, or state-space model that you can use with the LabVIEW Control Design and Simulation Module.

  • Nonlinear system identifica​tion using neural network (black box model)

     Hello, my thesis work is based on "suface EMG- angular acceleration modeling using different system identification techniques"......can anyone help me in doing nonlinear system identification using neural network...

    Well, look at that.  I actually had this problem before--and SOLVED it before!  [facepalm]  I'd forgotten all about it....
    https://bbs.archlinux.org/viewtopic.php?id=140151
    I just added "vmalloc=256" to my linux line, and X started right up!
    [edit] Well, mythtv had the solution, as well:  http://www.mythtv.org/wiki/Common_Probl … _too_small
    Last edited by wilberfan (2012-11-05 19:38:06)

  • System identifica​tion for power converter

    Dear All,
                i am working on system identification  for the buck converter . for this i generated variable duty cycle with 20KHz switching frequency on analog output AO1 of usb 6221, now i want to introduce perturbation PRBS in steady state. now my problem is to add perturbation on analog output. please suggest me how to do this on analog output.
    thanks
    with regards
    gurpreet singh

    Do you want to mix some signal to your PWM signals? You can use normal add function to add your AO PWM signals with the PBRS perturbation signal.

  • ARX Model Simulation - Error -41263

    Hello
    I'm trying to simulate an ARX model using System Identification pallete. I don't like to write too much about my problems when one VI can explain everything - so there it is, in attachment "Model Simulation.vi" works well, while "Model Simulation PtByPt.vi" gives me error -41263 (System Identification Toolset:  The System Identification Toolkit cannot retrieve the data in system model because the model type you wire in is incompatible with the system model requirements).
    Can anybody tell me what am I doing wrong?
    Just for reference: there was once similar topic, but unfortunately it didn't provide any answers at all: http://forums.ni.com/t5/LabVIEW/system-identification-error-41263/td-p/886077 .
    Solved!
    Go to Solution.
    Attachments:
    ARX.vi ‏23 KB

    That is correct, it accepts only State-Space model. It would be good if I could read this in documentation, not by asking here or by clicking inside the actual VI...

  • ITunes no longer works on my Windows VISTA system.  Get error msg saying C runtime library incorrectly... Error 7, Windows error 1114..

    iTunes no longer works on my Windows VISTA system.  Get error msg saying an application is attempting to access C runtime library incorrectly... Error 7, Windows error 1114.  Same msg, or one that says unable to install, when trying to update or reinstall iTunes.  iTunes worked well up until about a month ago when this error msg starting appearing.

    Go to Control Panel > Add or Remove Programs (Win XP) or Programs and Features (later)
    Remove all of these items in the following order:
    iTunes
    Apple Software Update
    Apple Mobile Device Support (if this won't uninstall move on to the next item)
    Bonjour
    Apple Application Support
    Reboot, download iTunes, then reinstall, either using an account with administrative rights, or right-clicking the downloaded installer and selecting Run as Administrator.
    The uninstall and reinstall process will preserve your iTunes library and settings, but ideally you would back up the library and your other important personal documents and data on a regular basis. See this user tip for a suggested technique.
    Please note:
    Some users may need to follow all the steps in whichever of the following support documents applies to their system. These include some additional manual file and folder deletions not mentioned above.
    HT1925: Removing and Reinstalling iTunes for Windows XP
    HT1923: Removing and reinstalling iTunes for Windows Vista, Windows 7, or Windows 8
    tt2

  • SAP System Message: Syntx error or generation error in a screen

    dear sap basis gurus,
    i am currently having problems signing on to our DEV server. i get this error message:
    <SID>: SAP System Message
    Syntx error or generation error in a screen.
    it won't let me log on.
    there were no changes made on the server (i.e., profile parameters) lately. it was working really fine after our support package level upgrade about 5 months ago.
    have you encountered this problem before? please help me as there we have two imminent go-lives.
    thank you very much in advance.
    best regards,
    albert

    hello nick, ashok,
    thank you very much for your responses.
    i have already resolved this issue by just freeing up some space from our disks. not one of them was full though.
    i hope i would no longer encounter the error message.
    again, thank you.
    best regards,
    albert

  • System Copy(homogenous) Error -Database load phase

    Hello All,
    I am doing System Copy thorugh Export - Import meothed of SAP R/3 4.7 110 on Windows2003-SQL 2000 SP3. Making Copy of Production server with different SID.After taking Export Successfully from Production Server I am Importing it to Target System
    but i am facing error at Database Load Phase getting the same error on almost every process like SAPSSEXE,SAPCLUST,SAPAPPL0,SAPAPPL1 etc. the error is below :
    E:\usr\sap\PRT\SYS\exe\run/R3load.exe: START OF LOG: 20090808202046
    E:\usr\sap\PRT\SYS\exe\run/R3load.exe: sccsid @(#) $Id: //bas/620/src/R3ld/R3load/R3ldmain.c#6 $ SAP
    E:\usr\sap\PRT\SYS\exe\run/R3load.exe: version R6.20/V1.2
    E:\usr\sap\PRT\SYS\exe\run/R3load.exe -ctf I C:\EXPORT/DATA/SAPAPPL1.STR C:\EXPORT/DB/DDLMSS.TPL C:\SAPinst MSSQL SAPINST3/SAPAPPL1.TSK MSS -l C:\SAPinst MSSQL SAPINST3/SAPAPPL1.log
    E:\usr\sap\PRT\SYS\exe\run/R3load.exe: job completed
    E:\usr\sap\PRT\SYS\exe\run/R3load.exe: END OF LOG: 20090808202047
    E:\usr\sap\PRT\SYS\exe\run/R3load.exe: START OF LOG: 20090808202053
    E:\usr\sap\PRT\SYS\exe\run/R3load.exe: sccsid @(#) $Id: //bas/620/src/R3ld/R3load/R3ldmain.c#6 $ SAP
    E:\usr\sap\PRT\SYS\exe\run/R3load.exe: version R6.20/V1.2
    E:\usr\sap\PRT\SYS\exe\run/R3load.exe -dbcodepage 1100 -i C:\SAPinst MSSQL SAPINST3/SAPAPPL1.cmd -l C:\SAPinst MSSQL SAPINST3/SAPAPPL1.log -loadprocedure fast
    DbSl Trace: SQLOLEDB Provider Release:08.10.3959
    DbSl Trace: Shared cache sizes: header 52 bytes, 10000 names (13360000 bytes), 1000 dynamic statements (5436000 bytes), total 18796052 bytes
    DbSl Trace: Initializing private procedure name cache.
    DbSl Trace: procedure cache created/attached
    DbSl Trace: Thank You for using the SLOLEDB-interface
    DbSl Trace: Connected to db server : [prdt], dbname: PRT, dbuser: prt
    DbSl Trace: Using dynamic link library 'E:\usr\sap\PRT\SYS\exe\run\dbmssslib.dll'
    DbSl Trace: dbmssslib.dll patch info
    DbSl Trace:   patchlevel   0
    DbSl Trace:   patchno      524
    DbSl Trace:   patchcomment DBDYNPSOURCE/DBDYNPSOURCE~, SHADOW_IMPORT_ALL (578789)
    DbSl Trace: The IRow interface is supported by this OLEDB provider
    DbSl Trace: ParamStmtExec: line 23573. hr: 0x80040e37 Invalid object name 'SVERS'.
    DbSl Trace: HandleOledbError [ParamStmtExec,line 23573]: Error/Message: (err 208, sev 16), Invalid object name 'SVERS'.
    DbSl Trace: ParamStmtExec failed.  HR 80040e37 DBSL retcode 103. stmt: [SELECT VERSION AS c FROM SVERS ]
    DbSl Trace: Conn_i:1 selection:1 singleton:1 flag_fupd:0 use_cursor:0 chksum:12157
    DbSl Trace: DbSlRead - Error 103 (dbcode 208) on open
    DbSl Trace: DbSlRead - <##Y2PRDTprt00000035720000000001202054>
    DbSl Trace: DbSlRead - Error 103 (dbcode 208) on fetch
    DbSl Trace: DbSlRead - <##Y2PRDTprt00000035720000000001202054>
    Sat Aug 08 20:20:54 2009
    **LOG BZA=> table SVERS      does not exist on database [dblink#1 @ 1292] [dblink  1292 ]
    (DB) INFO: connected to DB
    (GSI) INFO: dbname   = "PRTprdt                                                                                "
    (GSI) INFO: vname    = "MSSQL                           "
    (GSI) INFO: hostname = "PRDT                                                            "
    (GSI) INFO: sysname  = "Windows NT"
    (GSI) INFO: nodename = "PRDT"
    (GSI) INFO: release  = "5.2"
    (GSI) INFO: version  = "3790 Service Pack 2"
    (GSI) INFO: machine  = "2x Intel 80686 (Mod 15 Step 2)"
    DbSl Trace: ParamStmtExec: line 23573. hr: 0x80040e37 Invalid object name 'SVERS'.
    DbSl Trace: HandleOledbError [ParamStmtExec,line 23573]: Error/Message: (err 208, sev 16), Invalid object name 'SVERS'.
    DbSl Trace: ParamStmtExec failed.  HR 80040e37 DBSL retcode 103. stmt: [SELECT VERSION AS c FROM SVERS ]
    DbSl Trace: Conn_i:1 selection:1 singleton:1 flag_fupd:0 use_cursor:0 chksum:12157
    DbSl Trace: DbSlRead - Error 103 (dbcode 208) on open
    DbSl Trace: DbSlRead - <##Y2PRDTprt00000035720000000002202054>
    DbSl Trace: DbSlRead - Error 103 (dbcode 208) on fetch
    DbSl Trace: DbSlRead - <##Y2PRDTprt00000035720000000002202054>
    Interface access functions from dynamic library dbmssslib.dll loaded.(IMP) INFO: import of /1DF/__GI000 completed (0 rows)
    (IMP) INFO: import of /BDL/BADHOST completed (0 rows)
    (IMP) INFO: import of /BDL/CUSTSES completed (0 rows)
    (IMP) INFO: import of /BDL/INTSESS completed (0 rows)
    (IMP) INFO: import of /BDL/MSGLOG completed (0 rows)
    (IMP) INFO: import of /BDL/NOHOSTS completed (0 rows)
    (IMP) INFO: import of /BDL/SESDEST completed (0 rows)
    (IMP) INFO: import of /BDL/SESS completed (0 rows)
    (IMP) INFO: import of /BDL/STATUS completed (0 rows)
    (IMP) INFO: import of /BDL/TESTSES completed (0 rows)
    (IMP) INFO: import of /BDL/TRHOSTS completed (0 rows)
    (IMP) INFO: import of /SAPDMC/LSOFIL completed (56 rows)
    (IMP) INFO: import of /SAPDMC/LSOFIW completed (0 rows)
    (IMP) INFO: import of /SAPDMC/LSOPRT completed (0 rows)
    (IMP) INFO: import of /SAPSLL/BWHSTR3 completed (0 rows)
    (IMP) INFO: import of /SAPSLL/CUWLAR3 completed (0 rows)
    (IMP) INFO: import of /SAPSLL/KMATWLR3 completed (0 rows)
    (IMP) INFO: import of /SAPSLL/OBJIDX completed (0 rows)
    (IMP) INFO: import of /SAPSLL/OBJSSF completed (0 rows)
    (IMP) INFO: import of /SAPSLL/OBJSYNC completed (0 rows)
    (IMP) INFO: import of /SAPSMOSS/UPDATE completed (0 rows)
    (IMP) INFO: import of /SAPTRX/AOTREF completed (0 rows)
    (IMP) INFO: import of /SAPTRX/APPTALOG completed (0 rows)
    (IMP) INFO: import of /SAPTRX/ASITEMID completed (0 rows)
    (IMP) INFO: import of /SAPTRX/MTOBJLOG completed (0 rows)
    (IMP) INFO: import of /SCMB/DF_DEL_TAB completed (0 rows)
    (IMP) INFO: import of /SCMB/DF_DNET completed (0 rows)
    (IMP) INFO: import of /SCMB/DF_DOC completed (0 rows)
    (IMP) INFO: InitFastLoad failed with <3: (null)>(IMP) INFO: DBSL will be used(IMP) INFO: import of /SCMB/DF_DOC_VAL
    completed (0 rows)
    (IMP) INFO: import of /SCMB/DF_DQTY completed (0 rows)
    (IMP) INFO: import of /SCMB/DF_DVALUE completed (0 rows)
    (IMP) INFO: InitFastLoad failed with <3: (null)>(IMP) INFO: DBSL will be used(IMP) INFO: import of /SCMB/TREEVIEW2 completed
    (0 rows)
    (IMP) INFO: import of /SDF/INDX completed (0 rows)
    (IMP) INFO: import of /SDF/SDBAH completed (0 rows)
    (IMP) INFO: import of /SOMO/JOSCHEDL completed (0 rows)
    (IMP) INFO: import of /SOMO/JOSCHEDLT completed (0 rows)
    (IMP) INFO: import of /SSF/DHEAD completed (1 rows)
    (IMP) INFO: InitFastLoad failed with <3: (null)>(IMP) INFO: DBSL will be used(IMP) INFO: import of /SSF/DTAB completed (18
    rows)
    (IMP) INFO: InitFastLoad failed with <3: (null)>(IMP) INFO: DBSL will be used(IMP) INFO: import of /SSF/PTAB completed (7520 rows)
    (IMP) INFO: import of A055 completed (0 rows)
    (IMP) INFO: import of A056 completed (0 rows)
    (IMP) INFO: import of A064 completed (0 rows)
    (IMP) INFO: import of A065 completed (0 rows)
    (IMP) INFO: import of ABDBG_BPS completed (0 rows)
    (IMP) INFO: import of ABDBG_INFO completed (0 rows)
    (IMP) INFO: import of ACCRPOST completed (0 rows)
    (IMP) INFO: import of ACCTCR completed (7346418 rows)
    (IMP) INFO: import of ACCTHD completed (624272 rows)
    (IMP) INFO: import of ACCTIT completed (3673209 rows)
    (IMP) INFO: import of ACEPSOH completed (0 rows)
    (IMP) INFO: import of ACEPSOI completed (0 rows)
    (IMP) INFO: import of ACEPSOIT completed (0 rows)
    (IMP) INFO: import of ACL_ACE completed (0 rows)
    (IMP) INFO: import of ACL_ACTGR completed (0 rows)
    (IMP) INFO: import of ACL_ACTGRE completed (0 rows)
    (IMP) INFO: import of ACL_ACTGRT completed (0 rows)
    (IMP) INFO: import of ACL_ACTVT completed (0 rows)
    (IMP) INFO: import of ACL_ACTVTT completed (0 rows)
    (IMP) INFO: import of ACL_CACHE completed (0 rows)
    (IMP) INFO: import of ACL_MAIN completed (0 rows)
    (IMP) INFO: import of ACL_OBJTP completed (0 rows)
    (IMP) INFO: import of ACL_OBJTPA completed (0 rows)
    (IMP) INFO: import of ACL_OBJTPG completed (0 rows)
    (IMP) INFO: import of ACL_OBJTPT completed (0 rows)
    (IMP) INFO: import of ACL_OWNER completed (0 rows)
    (IMP) INFO: import of ACRELATION completed (76954 rows)
    (IMP) INFO: import of ACTFLI completed (0 rows)
    (IMP) INFO: import of AD01DLI completed (0 rows)
    (IMP) INFO: import of AD01DLIEF completed (0 rows)
    (IMP) INFO: import of AD01DLISF completed (0 rows)
    (IMP) INFO: import of AD01FILTVAR completed (0 rows)
    (IMP) INFO: import of AD01STRUCTVAR completed (0 rows)
    (IMP) INFO: import of AD01VARMASTER completed (0 rows)
    (IMP) INFO: import of ADATABSIZE completed (0 rows)
    (IMP) INFO: import of ADJT_TRANSACTION completed (0 rows)
    (IMP) INFO: import of ADMI_BUFFC completed (0 rows)
    (IMP) INFO: import of ADMI_BUFFI completed (0 rows)
    (IMP) INFO: import of ADMI_FILES completed (0 rows)
    (IMP) INFO: import of ADMI_JOBS completed (0 rows)
    (IMP) INFO: import of ADMI_RJOBS completed (0 rows)
    (IMP) INFO: import of ADMI_RUN completed (0 rows)
    (IMP) INFO: import of ADMI_SKIP completed (0 rows)
    (IMP) INFO: import of ADMI_STATS completed (0 rows)
    (IMP) INFO: import of ADMI_VARIA completed (0 rows)
    (IMP) INFO: import of ADMI_XDOCS completed (0 rows)
    (IMP) INFO: import of ADMI_XRUN completed (0 rows)
    (IMP) INFO: import of AFAB completed (0 rows)
    (IMP) INFO: import of AFBP completed (0 rows)
    (IMP) INFO: import of AFFH completed (0 rows)
    (IMP) INFO: import of AFFL completed (366118 rows)
    (IMP) INFO: import of AFFT completed (0 rows)
    (IMP) INFO: import of AFFV completed (0 rows)
    (IMP) INFO: import of AFFW completed (7 rows)
    (IMP) INFO: import of AFFWPRO completed (0 rows)
    (IMP) INFO: import of AFIH completed (113 rows)
    The above error are also present in the other Process log files.
    But when i saw the installation logs of the Source system the same errors are also there(but it was still Sucessfull Standard installation).
    there is one difference as well I am SQL SP3 (8.00.780) but existing Production server is SQL SP3(8.00.929).
    My installation is stoppoing here with error While executing Script.
    I've done Homogenous copy on WiN-ORACLE many times but on WIN-SQL i am doing very first time.
    While installation database phase it asked me for EXPORT CD twice first time for standard(which usually we got with SAP Software) and Second time for Migration EXPORT. that is different from ECC5.0 i think.
    Any suggestions?
    Regards,
    Vinay
    Edited by: Vinay Paul on Aug 8, 2009 11:01 PM

    Dear Markus,
    Thanks for the Reply.
    As you Said i am upgrading my kernal (making it same as current kernel using bysource system that is 175).
    Hope this will solve my problem ....Do i have to restart my complete installation now?
    My recent last error was :
    SAPSSRC.LOG
    E:\usr\sap\PRT\SYS\exe\run/R3load.exe: START OF LOG: 20090808202048
    E:\usr\sap\PRT\SYS\exe\run/R3load.exe: sccsid @(#) $Id: //bas/620/src/R3ld/R3load/R3ldmain.c#6 $ SAP
    E:\usr\sap\PRT\SYS\exe\run/R3load.exe: version R6.20/V1.2
    E:\usr\sap\PRT\SYS\exe\run/R3load.exe -ctf I C:\EXPORT/DATA/SAPSSRC.STR C:\EXPORT/DB/DDLMSS.TPL C:\SAPinst MSSQL SAPINST3/SAPSSRC.TSK MSS -l C:\SAPinst MSSQL SAPINST3/SAPSSRC.log
    E:\usr\sap\PRT\SYS\exe\run/R3load.exe: job completed
    E:\usr\sap\PRT\SYS\exe\run/R3load.exe: END OF LOG: 20090808202048
    E:\usr\sap\PRT\SYS\exe\run/R3load.exe: START OF LOG: 20090808221527
    E:\usr\sap\PRT\SYS\exe\run/R3load.exe: sccsid @(#) $Id: //bas/620/src/R3ld/R3load/R3ldmain.c#6 $ SAP
    E:\usr\sap\PRT\SYS\exe\run/R3load.exe: version R6.20/V1.2
    E:\usr\sap\PRT\SYS\exe\run/R3load.exe -dbcodepage 1100 -i C:\SAPinst MSSQL SAPINST3/SAPSSRC.cmd -l C:\SAPinst MSSQL SAPINST3/SAPSSRC.log -loadprocedure fast
    DbSl Trace: SQLOLEDB Provider Release:08.10.3959
    DbSl Trace: Shared cache sizes: header 52 bytes, 10000 names (13360000 bytes), 1000 dynamic statements (5436000 bytes), total 18796052 bytes
    DbSl Trace: Initializing private procedure name cache.
    DbSl Trace: procedure cache created/attached
    DbSl Trace: Thank You for using the SLOLEDB-interface
    DbSl Trace: Connected to db server : [prdt], dbname: PRT, dbuser: prt
    DbSl Trace: Using dynamic link library 'E:\usr\sap\PRT\SYS\exe\run\dbmssslib.dll'
    DbSl Trace: dbmssslib.dll patch info
    DbSl Trace:   patchlevel   0
    DbSl Trace:   patchno      524
    DbSl Trace:   patchcomment DBDYNPSOURCE/DBDYNPSOURCE~, SHADOW_IMPORT_ALL (578789)
    DbSl Trace: The IRow interface is supported by this OLEDB provider
    (DB) INFO: connected to DB
    (GSI) INFO: dbname   = "PRTprdt                                                                                "
    (GSI) INFO: vname    = "MSSQL                           "
    (GSI) INFO: hostname = "PRDT                                                            "
    (GSI) INFO: sysname  = "Windows NT"
    (GSI) INFO: nodename = "PRDT"
    (GSI) INFO: release  = "5.2"
    (GSI) INFO: version  = "3790 Service Pack 2"
    (GSI) INFO: machine  = "2x Intel 80686 (Mod 15 Step 2)"
    Interface access functions from dynamic library dbmssslib.dll loaded.(IMP) INFO: import of ABTREE completed (39 rows)
    (IMP) INFO: import of AKB_CHKCONF completed (0 rows)
    (IMP) INFO: import of AKB_INDX completed (0 rows)
    (IMP) INFO: import of APTREE completed (1531 rows)
    (IMP) INFO: import of APTREET completed (75 rows)
    (IMP) INFO: import of CAPTREE completed (0 rows)
    (IMP) INFO: import of CAPTREET completed (0 rows)
    (IMP) INFO: import of CCCEXIT completed (44 rows)
    (IMP) INFO: import of CCCINFO completed (15 rows)
    (IMP) INFO: import of CLMCUS completed (0 rows)
    (IMP) INFO: import of CONTCOMP completed (2 rows)
    (IMP) INFO: import of CONTCOMPT completed (4 rows)
    (IMP) INFO: import of CONTCOMPX completed (2 rows)
    (IMP) INFO: import of CONTCOMPXT completed (3 rows)
    (IMP) INFO: import of CROSS completed (1399548 rows)
    (IMP) INFO: import of CUSTDIR completed (0 rows)
    (IMP) INFO: import of CWBMODILOG completed (0 rows)
    (IMP) INFO: import of DBDATA completed (0 rows)
    (IMP) INFO: import of DIRTREE completed (21 rows)
    (IMP) INFO: import of DVSEQDIR completed (0 rows)
    (IMP) INFO: import of DWTREE completed (522 rows)
    (IMP) INFO: import of EUDIAL completed (0 rows)
    (IMP) INFO: import of EUF4VALUES completed (34 rows)
    (IMP) INFO: import of EUFUNC completed (76 rows)
    (IMP) INFO: import of EUIMPORT completed (47 rows)
    (IMP) INFO: import of EUINFO completed (2772 rows)
    (IMP) INFO: import of EUINFOLI completed (0 rows)
    (IMP) INFO: import of FUSEQDIR completed (0 rows)
    (IMP) INFO: import of GUIDIR completed (0 rows)
    (IMP) INFO: import of GUIDIRT completed (3 rows)
    (IMP) INFO: import of GUINODE completed (0 rows)
    (IMP) INFO: import of GUINODT completed (0 rows)
    (IMP) INFO: import of ICON completed (982 rows)
    (IMP) INFO: import of ICONP completed (149 rows)
    (IMP) INFO: import of ICONT completed (3361 rows)
    (IMP) INFO: import of ICO_P completed (0 rows)
    (IMP) INFO: import of LDBS completed (0 rows)
    (IMP) INFO: import of MAPPARAREF completed (0 rows)
    (IMP) INFO: import of MODACT completed (0 rows)
    (IMP) INFO: import of MODATTR completed (0 rows)
    (IMP) INFO: import of MODIDIR completed (0 rows)
    (IMP) INFO: import of MODSAPA completed (2049 rows)
    (IMP) INFO: import of MODSAPT completed (3991 rows)
    (IMP) INFO: import of MODTEXT completed (0 rows)
    (IMP) INFO: import of O2APPL completed (164 rows)
    (IMP) INFO: import of O2APPLT completed (305 rows)
    (IMP) INFO: import of O2PAGCON completed (4120 rows)
    (IMP) INFO: import of O2THEMEREL completed (0 rows)
    (IMP) INFO: import of O2THEMES completed (1 rows)
    (IMP) INFO: import of O2THEMEST completed (0 rows)
    (IMP) INFO: import of O2XMLDESC completed (89 rows)
    (IMP) INFO: import of O2XSLTDESC completed (163 rows)
    (IMP) INFO: import of O2XSLTOTR completed (0 rows)
    (IMP) INFO: import of O2XSLTTEXT completed (385 rows)
    (IMP) INFO: import of OBJ_DIFF completed (0 rows)
    (IMP) INFO: import of OXT_PICTURE completed (146 rows)
    (IMP) INFO: import of PACKCHECK_EXCEPT completed (131 rows)
    (IMP) INFO: import of PRICAT_FIELD completed (172 rows)
    (IMP) INFO: import of PRICAT_FIELDT completed (343 rows)
    (IMP) INFO: import of PROP_ELTYP completed (27 rows)
    (IMP) INFO: import of RLB_DB_LB completed (2 rows)
    (IMP) INFO: import of RLB_DB_LBT completed (4 rows)
    (IMP) INFO: import of RLB_DB_PR completed (31 rows)
    (IMP) INFO: import of RLB_DB_PRT completed (62 rows)
    (IMP) INFO: import of RLIB_CONT completed (0 rows)
    (IMP) INFO: import of RLIB_OBJS completed (1160 rows)
    (IMP) INFO: import of RLIB_TREES completed (5 rows)
    (IMP) INFO: import of RSEUINC completed (588382 rows)
    (IMP) INFO: import of RSEUMOD completed (49 rows)
    (IMP) INFO: import of RSEUTAB completed (0 rows)
    (IMP) INFO: import of RSMPCHECK completed (31 rows)
    (IMP) INFO: import of RSMPCHECKT completed (62 rows)
    (IMP) INFO: import of RSMPTEXTSI completed (0 rows)
    (IMP) INFO: import of RSNORMTXT completed (246 rows)
    (IMP) INFO: import of SDBUSRSET completed (0 rows)
    (IMP) INFO: import of SMODILOG completed (125 rows)
    (IMP) INFO: import of SMODILOGI completed (0 rows)
    (IMP) INFO: import of SMODIPROJ completed (0 rows)
    (IMP) INFO: import of SMODISRC completed (492 rows)
    (IMP) INFO: import of SMODISRCI completed (0 rows)
    (IMP) INFO: import of SMODITRAN completed (0 rows)
    (IMP) INFO: import of SMODIUSER completed (0 rows)
    (IMP) INFO: InitFastLoad failed with <3: (null)>(IMP) INFO: DBSL will be used(IMP) ERROR: DbSlExeModify/DbSlLobPutPiece failed
      rc = 22, table "SPROXDAT"
    (IMP) INFO: InitFastLoad failed with <3: (null)>(IMP) INFO: DBSL will be usedDbSl Trace: invalid sign in BCD number: 1
    DbSl Trace: Error converting decimal:  000000000200303.0 HEX: 0000000002003031 input variable# 12, proc: ## No proc
    DbSl Trace: invalid sign in BCD number: 1
    DbSl Trace: Error converting decimal:  000000000200303.0 HEX: 0000000002003031 input variable# 14, proc: ## No proc
    DbSl Trace: internal error in decimal conversion.
    (IMP) ERROR: DbSlExeModify/DbSlLobPutPiece failed
      rc = 8, table "SPROXHDR"
    (IMP) INFO: import of SPROXINDX completed (0 rows)
    (IMP) INFO: import of SPROXKEY completed (0 rows)
    (IMP) INFO: import of SPROXREG completed (9 rows)
    (IMP) INFO: import of SPROXSET completed (0 rows)
    (IMP) INFO: InitFastLoad failed with <3: (null)>(IMP) INFO: DBSL will be used(IMP) INFO: import of SPROXTST completed (0 rows)
    (IMP) INFO: import of SRESETLOG completed (0 rows)
    (IMP) INFO: import of SRESETLOG2 completed (0 rows)
    (IMP) INFO: import of SXC_ATTR completed (1045 rows)
    (IMP) INFO: import of SXC_ATTRT completed (1855 rows)
    (IMP) INFO: import of SXC_CLASS completed (1045 rows)
    (IMP) INFO: import of SXC_COCO completed (0 rows)
    (IMP) INFO: import of SXC_EXIT completed (1449 rows)
    (IMP) INFO: import of SXC_FCODE completed (11 rows)
    (IMP) INFO: import of SXC_FCODET completed (23 rows)
    (IMP) INFO: import of SXC_IMPSWH completed (2551 rows)
    (IMP) INFO: import of SXC_SCRN completed (47 rows)
    (IMP) INFO: import of SXC_TABLE completed (0 rows)
    (IMP) INFO: import of SXC_TABLET completed (0 rows)
    (IMP) INFO: import of SXS_ATTR completed (2093 rows)
    (IMP) INFO: import of SXS_ATTRT completed (4020 rows)
    (IMP) INFO: import of SXS_COCO completed (0 rows)
    (IMP) INFO: import of SXS_FCODE completed (64 rows)
    (IMP) INFO: import of SXS_FCODET completed (128 rows)
    (IMP) INFO: import of SXS_INTER completed (2093 rows)
    (IMP) INFO: import of SXS_MLCO completed (616 rows)
    (IMP) INFO: import of SXS_SCRN completed (80 rows)
    (IMP) INFO: import of SXS_SCRNT completed (141 rows)
    (IMP) INFO: import of SXS_TABLE completed (1 rows)
    (IMP) INFO: import of SXS_TABLET completed (2 rows)
    (IMP) INFO: import of SYS_COMP completed (0 rows)
    (IMP) INFO: import of TBPROGREF completed (251 rows)
    (IMP) INFO: import of TBVIEWER completed (0 rows)
    (IMP) INFO: import of TCG01 completed (9 rows)
    (IMP) INFO: import of TCP11 completed (1 rows)
    (IMP) INFO: import of TCP13 completed (0 rows)
    (IMP) INFO: import of TCP17 completed (0 rows)
    (IMP) INFO: import of TGLIF completed (534 rows)
    (IMP) INFO: import of THELPI completed (0 rows)
    (IMP) INFO: import of TMCRT completed (303 rows)
    (IMP) INFO: import of TMEMO completed (0 rows)
    (IMP) INFO: import of TRANSFDESC completed (0 rows)
    (IMP) INFO: import of TRANSFTEXT completed (0 rows)
    (IMP) INFO: import of TRDIRE completed (32350 rows)
    (IMP) INFO: import of TREELOG completed (15990 rows)
    (IMP) INFO: import of W3HTMLT completed (1138 rows)
    (IMP) INFO: import of W3HTRCT completed (162 rows)
    (IMP) INFO: import of W3JSCRT completed (0 rows)
    (IMP) INFO: import of W3MIMET completed (361 rows)
    (IMP) INFO: import of W3OBJLOINF completed (0 rows)
    (IMP) INFO: import of W3PUBDIR completed (0 rows)
    (IMP) INFO: import of W3SERINTP completed (44 rows)
    (IMP) INFO: import of W3SERINTPT completed (63 rows)
    (IMP) INFO: import of W3SERVICET completed (156 rows)
    (IMP) INFO: import of WBCROSSGT completed (126383 rows)
    (IMP) INFO: import of WBCROSSI completed (5654 rows)
    (DB) INFO: disconnected from DB
    E:\usr\sap\PRT\SYS\exe\run/R3load.exe: job finished with 2 error(s)
    E:\usr\sap\PRT\SYS\exe\run/R3load.exe: END OF LOG: 20090808221726
    Regards,
    Vinay

  • An error has occurred. Please try again, and if the problem persists, contact your help desk or system administrator. (Error 3000)

    Hi,
    When i open my Password Reset portal then provide Username credentials in text box and click on next then asked the Securites Question Answers to me,i provide the correct Answers to the securites Question after this password reset portal asked
    me New Password and Confirm Password then click on next for resetting the password then gives below Error only for 2 Users. and all other users are working fine.
    An error has occurred. Please try again, and if the problem persists, contact your help desk or system administrator. (Error 3000:)
    Regards
    Anil Kumar

    Anything in the event log?

  • Request xy in system xy: internal error 0000000040/ in spooler ()

    Hi SAP community,
    when I am running a customized COPA report in background I got the following error message when I am trying to access the spool (job itself finished successfully):
    <b>Request xy in system xy: internal error 0000000040/ in spooler ()
    Message no. SP01R 042
    Diagnosis
    An unexpected error occurred in the spooler.
    Procedure
    Write down the exact message text and notify your system administrator.
    A message of this type contains three variables:
    Internal error x/y in spooler: z
    x is the SY-SUBRC of the CALL module.
    y is the error number of the C library of the spooler. See also "RSPOE..." in "rspo.h".
    z is a more detailed description of the error and may contain information about what the user can do (for example: try again later, end session, and so on).</b>
    Thanks in advance for your support.
    Best regards,
    Chris

    Hi SAP community,
    It appears that certain spool requests can not be displayed because of format restrictions. 
    OSS note 186603

  • Getting an error while configuring VMM for System Center 2012. error - An internal error has occurred trying to contact an agent on the WIN-NTJU8CNU server: : . Ensure the agent is installed and running.

    Hi,
    I am trying to install "System Center 2012 - Virtual Machine Manager by Using a Pre-Configured VHD".
    I downloaded install guide & the binaries from http://www.microsoft.com/en-us/download/details.aspx?displaylang=en&id=10712
    I have followed the installation document & getting an error while configuring VMM for System Center 2012.
    error details from log file given below:
    01:12:24:VMMPostinstallProcessor threw an exception: Threw Exception.Type: Microsoft.Carmine.WSManWrappers.WSManProviderException, Exception.Message: An internal error has occurred trying to contact an agent on the WIN-NTJTNEJ1UCN.mydomain.com server: : .
    Ensure the agent is installed and running. Ensure the WS-Management service is installed and running, then restart the agent.
    01:12:24:StackTrace:   at Microsoft.Carmine.WSManWrappers.ErrorContextParameterHelper.ThrowTranslatedCarmineException(WsmanSoapFault fault, COMException ce)
       at Microsoft.Carmine.WSManWrappers.WsmanAPIWrapper.RetrieveUnderlyingWMIErrorAndThrow(SessionCacheElement sessionElement, COMException ce)
       at Microsoft.Carmine.WSManWrappers.WsmanAPIWrapper.Invoke(String actionUri, WSManUri targetUri, Hashtable parameters, Type returnType, Boolean isCarmineMethod, Boolean forceResponseCast)
       at Microsoft.Carmine.WSManWrappers.AgentManagement.AssociateLibrary(WsmanAPIWrapper wsmanObject, String CertificateSubjectName, String& ExportedCertificate, ErrorInfo& ErrorInfo)
       at Microsoft.VirtualManager.Setup.VirtualMachineManagerHelpers.AssociateAgentServer(String fullyQualifiedServerName)
       at Microsoft.VirtualManager.Setup.VirtualMachineManagerHelpers.AssociateDefaultLibraryServer()
       at Microsoft.VirtualManager.Setup.VirtualMachineManagerHelpers.SetupLibraryShare()
       at Microsoft.VirtualManager.Setup.InstallItemCustomDelegates.PangaeaServerPostinstallProcessor()
    01:12:24:InnerException.Type: System.Runtime.InteropServices.COMException, InnerException.Message: There is a time and/or date difference between the client and server.
    01:12:24:InnerException.StackTrace:   at WSManAutomation.IWSManSession.Invoke(String actionUri, Object resourceUri, String parameters, Int32 flags)
       at Microsoft.Carmine.WSManWrappers.MyIWSManSession.Invoke(String actionUri, Object resourceUri, String parameters, Int32 flags)
       at Microsoft.Carmine.WSManWrappers.WsmanAPIWrapper.Invoke(String actionUri, WSManUri targetUri, Hashtable parameters, Type returnType, Boolean isCarmineMethod, Boolean forceResponseCast)
    01:12:24:ProcessInstalls: Running the PostProcessDelegate returned false.
    01:12:24:ProcessInstalls: Running the PostProcessDelegate for PangaeaServer failed.... This is a fatal item.  Setting rollback.
    01:12:24:SetProgressScreen: FinishMinorStep.
    01:12:24:ProcessInstalls: Rollback is set and we are not doing an uninstall so we will stop processing installs
    I have completed MSSQL server configuration and while configuring VMM the below error displayed in the wizard:
    An internal error has occurred trying to contact an agent on the WIN-NTJTNEJ1UCN.mydomain.com server: : .
    Ensure the agent is installed and running. Ensure the WS-Management service is installed and running, then restart the agent.
    I have checked that the following services are running:
    1) Verified WS-Management srvice 2) MSSQL server + MSSQL (agent)  3)SC VM Manager Agent  4)  Windows management instrumentation .
    I have joined the VM (on which installing SC VMM) in a domain(as per install guide) and installing VMM using domain account & it is in local Administrators group.
    Also I would like know if there is any stand alone SC VMM installer. If yes then please let me know the installer location & install guide.
    thanks.
    ====

    Have you installed AppController on the same machine with VMM?

  • System.Exception: An error occurred during the Microsoft VSTO Tools 4.0 install (exit code was -2146762485).

    I have been trying to install a piece of software on 2 Windows 7 PCS called Rightfax...during installing I get the error below;
           System.Exception: An error occurred during the Microsoft VSTO Tools 4.0 install (exit code was -2146762485).
    It then gives me an error log of ;
    2015-04-23 14:43:03Z: Error: Unexpected problem occurred in task worker
           System.Exception: An error occurred during the Microsoft VSTO Tools 4.0 install (exit code was -2146762485).
              at CommonInstall.Tasks.InstallTask.LaunchInstall(String friendlyName, String exe, String args, Int32[] exitCodesToIgnore)
              at CommonInstall.Tasks.InstallVSTO.OnRun(ITaskFeedback feedback)
              at TaskWizard.Task.Run(ITaskFeedback feedback, Boolean recurse)
              at TaskWizard.TaskWorker.RunTasks()
              at TaskWizard.TaskWorker.OnDoWork(DoWorkEventArgs e)
    2015-04-23 14:43:03Z: Error: Problem in sequence or one of its pages
           System.Exception: An error occurred during the Microsoft VSTO Tools 4.0 install (exit code was -2146762485).
              at CommonInstall.Tasks.InstallTask.LaunchInstall(String friendlyName, String exe, String args, Int32[] exitCodesToIgnore)
              at CommonInstall.Tasks.InstallVSTO.OnRun(ITaskFeedback feedback)
              at TaskWizard.Task.Run(ITaskFeedback feedback, Boolean recurse)
              at TaskWizard.TaskWorker.RunTasks()
              at TaskWizard.TaskWorker.OnDoWork(DoWorkEventArgs e)
              at CommonInstall.PreparationWorker.OnDoWork(DoWorkEventArgs e)
              at System.ComponentModel.BackgroundWorker.WorkerThreadStart(Object argument)
    2015-04-23 14:43:03Z: Error: Problem in sequence or one of its pages
           System.Exception: An error occurred during the Microsoft VSTO Tools 4.0 install (exit code was -2146762485).
              at CommonInstall.Tasks.InstallTask.LaunchInstall(String friendlyName, String exe, String args, Int32[] exitCodesToIgnore)
              at CommonInstall.Tasks.InstallVSTO.OnRun(ITaskFeedback feedback)
              at TaskWizard.Task.Run(ITaskFeedback feedback, Boolean recurse)
              at TaskWizard.TaskWorker.RunTasks()
              at TaskWizard.TaskWorker.OnDoWork(DoWorkEventArgs e)
              at CommonInstall.PreparationWorker.OnDoWork(DoWorkEventArgs e)
              at System.ComponentModel.BackgroundWorker.WorkerThreadStart(Object argument)
    2015-04-23 14:43:03Z: Info: Page changed from 'WizardWorkerPage' to 'ResultPage' driven by result 'Next' and exception 'none'
    2015-04-23 14:44:06Z: Info: Page changed from 'ResultPage' to 'none' driven by result 'Next' and exception 'none'
    2015-04-23 14:44:06Z: Info: Work has not been completed; install state will not be saved.
    2015-04-23 14:44:06Z: Info: Reboot status = NotRequired
    2015-04-23 14:44:06Z: Info: Exitcode = 0
    2015-04-23 14:44:06Z: Info: Logging ended.
    I have installed this software succesfully on other machines previously.....

    Hi RyanWelsh78,
    This forum is discussing about Visual Stuido Tools for Office developing, your issue is related with the installing Rightfax add-in which is a third party product. As the reply from Eugene, you could contact Rightfax add-in developers for help.
    Thanks for your understanding.
    Best Regards,
    Edward
    We are trying to better understand customer views on social support experience, so your participation in this interview project would be greatly appreciated if you have time. Thanks for helping make community forums a great place.
    Click
    HERE to participate the survey.

Maybe you are looking for

  • No longer possible to download exe files (say Cancel in the download window

    no longer possible to download exe files (say Cancel in the download window == This happened == Every time Firefox opened == some months

  • More than100 Items on a Page

    When there are more than 100 Items on a page a message appears below the list of items "Item count of X exceeds maximum of 100". What happens when you exceed the maximum number of items?

  • Field AWKEY in BKPF not working due to case sensitive

    Hi, I have reference key as cpv8852MLTD2013, but when i enter this in AWKEY field in BKPF it gets converted to upper case as "CPV8852MLTD2013". Due to this it is not working, and data is not executing.. Please help.. Durga

  • Why can't I save my GIF in Photoshop CS5?

    When I click 'Save for Web and Devices' the window pops up and it starts to load. But then the image goes red. If I click save it says I don't have enough memory to save the image or Photoshop just forces closed. Please help me fix this! What is goin

  • Column Total in RTF

    Hello, Here is a sample of my report. Project Name | Task Name | Current | Bill | Apply P1 | T | 300 | 0 | 300 (sum of T1 and T2) | T1 | 200 | 0 | 200 | T2 | 100 | 0 | 100 P2 | T | 400 | 0 | 400 Grand Total P | T | 700 | 0 | 700 (Total P1 + Total P2)