System Measurement with MII
Hi all,
has anyone ever did a System Measurement with a MII system? I know this procedure only with SAP systems with ABAP stack, not NetWeaver systems that only run with a Java stack.
At the moment I only see a way of collecting a list the defined users with some measurement related data and send it to the measurement people.
Michael
Hi,
we have received an answer from SAP Global Licence Auditing Services.
NetWeaver Systems with UME User management that only have a Java stack implemented (like our system with MII) officially do not need to take part in the SAP system measurement. The functionality of system measurement for portals and duet systems is implemented but currently in a test phase.
Michael
Similar Messages
-
System Measurement - Error while exporting to LAW file
Hi all,
We have the SAP ERP 6.0. We started the system measurement on our ECC landscape with the aim to consolidate the results with LAW in Solution Manager. We performed the measurement in our production server and we select System Measurement - Export to Law File and execute, we are having the following error:
Last measurement was not successfully performed (see USMM)
We are having the error despite doing the measurement afresh
Grateful if you could suggest what to do.
regdsHi all
thanks for all your comments.
We have tested in other system with Basis 14 and it works there. So we are presuming that the error is due to Basis being level 13.
Still, we have informed SAP about the error.
thanks all. -
Personal recruitment How to do new measure with function call Update IT4000
Hi out there and happy new year to forum,
i want to update to implement a recruitment measure (Transaction PB40). I did it already with batch input, but i guess it's much more comfortable to do with funtion module, bapi or calsses.
After choosing the measure, the infogroup will be processed. So i guess, i just have to use the corresponding function modules to update the infotypes in a given sequence. is this suggestion right?
What are these function modules? How to update f.e. IT4000? Does anyone has a coding snippet?
Is it HR_INFOTYPE_OPERATION?
In our Infogroup there are also customer specific infotypes f.e. 9***. Can I use the sap standard function modules for "own implemented" infotypes?
I also appreciate an abap oo pattern or any similar....
Best regards,
TAndy Goris wrote:
But I don't think that it's possible to hire an application completly with function modules (there is no PERNR in the beginning so I would keep the BIM).
The applicants already exists in system, i just want to implement a measure with exact one click!
Otherwise there is a BAPI for applicant_create.
I'm not very expierienced focussing the implementation in pa-recruiting. I'm really looking for a good documentation or anything like that f.e. sap press.
Andy Goris wrote:
... but why would you use the old recruiting database? This is hardly used anymore.
What are the alternatives to it. (I'm not looking forward to upgrade releases or using wd4a or webgui). we are on ecc 6.0 There is already a lot of z-coding in recruitment. We are also using an self implemented e-recruiting approach
Edited by: Timo Ehl on Jan 3, 2012 2:30 PM -
Error "CONVT_NO_NUMBER" while performing user measurement with USMM
Hi,
While running user measurement with USMM I am getting following run
time error.
To be specific - After preselections in USMM->system measurement->while
checking Green Check mark this error is screaming up.
Ae per Note - 1230640 :- You call transaction USMM and want to cancel
the user measurement using the cancel button (red 'X') on the dialog
box of the user measurement. However, the measurement continues and is
completed as if you had chosen the ok button (green check mark).
Above note is applied if the problem comes if we check red button
rather than green check mark.
Please suggest us the best way to procees.
ST22 details:-
Runtime Errors CONVT_NO_NUMBER
Exception CX_SY_CONVERSION_NO_NUMBER
Date and Time 09/16/2008 07:42:32
Short text
Unable to interpret " 1,410 " as a number.
What happened?
Error in the ABAP Application Program
The current ABAP program "RSUVM001" had to be terminated because
it has
come across a statement that unfortunately cannot be executed.
What can you do?
Note down which actions and inputs caused the error.
To process the problem further, contact you SAP system
administrator.
Using Transaction ST22 for ABAP Dump Analysis, you can look
at and manage termination messages, and you can also
keep them for a long time.
Error analysis
An exception occurred that is explained in detail below.
The exception, which is assigned to
class 'CX_SY_CONVERSION_NO_NUMBER', was not
caught and
therefore caused a runtime error.
How to correct the error
Whole numbers are represented in ABAP as a sequence of numbers,
possibly
with an algebraic sign.
The following are the possibilities for the representation of
floating
point numbers:
[mantissa]E[algebraic sign][exponent]
[whole number part].[fraction part]
For example, -12E+34, +12E-34, 12E34, 12.34
If the error occurred in your own ABAP program or in an SAP
program you modified, try to remove the error.
If the error occures in a non-modified SAP program, you may be able
to
find an interim solution in an SAP Note.
If you have access to SAP Notes, carry out a search with the
following
keywords:
"CONVT_NO_NUMBER" "CX_SY_CONVERSION_NO_NUMBER"
"RSUVM001" or "RSUVM001"
"START-OF-SELECTION"
If you cannot solve the problem yourself and want to send an error
notification to SAP, include the following information:
1. The description of the current problem (short dump)
Information on where terminated
Termination occurred in the ABAP program "RSUVM001" - in "START-OF-
SELECTION".
The main program was "RSUVM001 ".
In the source code you have the termination point in line 96
of the (Include) program "RSUVM001".
85 * Analyze the user records.
86 CALL FUNCTION 'SAPGUI_PROGRESS_INDICATOR'
87 EXPORTING
88 text = 'Die Benutzerstammsätze werden analysiert.'(002).
89 * PERFORM analyze_user_records.
90
91 CALL FUNCTION 'SLIM_USER_MEASUREMENET'
92 CHANGING
93 SLIM_TUREP = LT_TUREP.
94 .
95 LOOP AT LT_TUREP INTO LS_TUREP .
>>>>> MOVE-CORRESPONDING LS_TUREP TO ITUREP.
97 APPEND ITUREP.
98 ENDLOOP.
99
100 * Submit Application measurements as batch jobs.
101 * Save additional data about this analysis in the DB.
102 * we need meas-no ,v-date at the batch
any ideas?Hi Srikanth,
The below Notes helps you to solve the issue.
Please review the below Notes.
Note 1117010 - Runtime error CONVT_NO_NUMBER in RSUVM001
Note 1115924 - USMM composite SAP Note: Problems after importimg new SPs
Thanks & Regards,
Pradeep Srigiri -
Hello Guys,
I am performing System Measurement USMM in our Development System.
I have 4 clients in the system, but we are using only one client out of it. So selected that particular client only for measurement.
I got the result as below:
Results by User Type
UserType ID Surcharges Number
Test 91 21
SAP Application Developer CA 1
Distribution of Technical User Types
Dialog 1
System 3
Communications Data 3
Reference (Logon not possible) 13
Service 15
We have purchased only 1 Developer License.
Please help me understanf following questions:
1. Based on above output, hw much licenses will SAP consider in the Development system?
2. Will SAP consider Service users also for licensing? The Service users are accounts like ADS_AGENT, Service users from R3 to Poratl connectivity.
3. Since I have 3 more clients (excluded from Measurement), will the users from those clients also be considered for SAP Licenses? There are about 1000 test users from other 3 clients.
Thanks
SagarSagar,
Subject to your agreement with them, it would normally only be the number of users in the Production system that SAP would want to know about. The number of users in DEV is usually not an issue. The only thing they might query is if you have several developers in the DEV or TEST systems, but not in Production.
They don't count Service users or Communication users.
Tony -
PCo integration with MII and MES
Hi,
How is PCo placed in MII and ME Achitecture. Can PCo directly connects to Shopl floor systems? and how it is connected to MES system. IS this something like Shop floor>PCo->MII->ME->ERP?
Can someone please make me understand?
Thanks,
RaveenHi,
as per my knowledge MII helps to interface between MES (if it is installed) and ERP.
if we consider levels then
all the PLCs are in level 1.
all the scada,Historian are in level 2,
MES and database in level 3,
and ERP in level 4.
MII is between level 3 and level 4,
it helps to interface this two level.
as I know PCO can configured with MII. PCO help to create that connectivity between the tag value coming from the scada historian system and MII.
regards,
Suman -
while running transaction usmm for system measurement i noticed i get
results regrading 3 kinds of users - professional,limited pro,employee.
according to which principle the clasification to user types is made? -
in other words can i move user from one clasification to another
(professional to limited pro for example) or is it related to
rolesgiven to each user?.Hello Moshe,
I don't get you. What's your problem?
User types are for pricing.
So every user type stands for a different fee you have to pay to SAP.
An user who only want to see data is cheaper than an user who want to change data.
When you do a system measurement and send the data to SAP, then they can evaluate the users with a certain user type and compute the fee for your user licenses.
Regards, Michael
p.S.: I never mentioned a test user type -
System measurement using USMM transaction
Hi Guys,
Does any one have experience in using the USMM transaction for system measurement?
Pls throw some light on this Transaction and also about the purpose of using USMM t-code. If any body has any document related to this T-code pls share the link.
regards,
Vinodh.Hi,
This is used to generate Statics, measurement of SAP systems to know the no: users, license, Installed components,List of clients,Users with SSCR key,
Goto tcode USMM and press the System Measurement button and it runs approximately 8 jobs in background.After completion of jobs in background go to USMM and get the <SID>fax.txt by executing the button Report and
<SID>stat.txt by executing the button Measurement statistics.Goto SE38 and execute the report YSLIR101 by giving variant.
Regards
Umesh K -
Hello,
I have a NI-DAC-9172 housing with the module NI9263 connected to an programmable power supply (for voltage input and current limitation) and the NI9205 "analogue in" that receives the signal back from the power supply.
Info: Power supply as a small digital display where is possible to see the voltage and current at the system
Problem:Voltage measurement with noise => Max measured voltage match with the output voltage supplyCurrent measurement with noise => difficult to see... (at the files you have the current value showed by power supply Additional info:The voltage output from the power supply to the NI cDAC is stable => measured with multimeterThe only difference between channels is the factor I am using => Voltage (factor 2) to Current (factor 13)Power supply input/output 0-10V (for programmable use) /// Power supply operational output range 0-20V / 0-130A Script:Voltage and Current command over Diadem => Status workingVoltage and Current writing in diadem => Status "noise" Question: Do you have any guess how can I solve this problem? Thanks Pedro
Attachments:
visual.zip 716 KBHi Pedro,
Is this really a DIAdem question? Are you wanting to remove the noise from signals you've stored from DAQ to a data file (TDMS?), or are you instead asking about how to configure the DAQ aquisition? If the latter is the case, you're barking up the wrong forum...
Brad Turpin
DIAdem Product Support Engineer
National Instruments -
Sound Power Measurement with 4472
Is onboard DSP a must for any Sound Power Measurement?
I know that NI-Sound Power Plus works only with 455x.
Is it simply because NI has not yet written a software for Sound Power Measurement using 4472 or is it technically NOT possibly to do Sound Power Measurment using 4472?
Gurdas Singh
PhD. Candidate | Civil Engineering | NCSU.edu1. The 6036E is a "sweet" card for high-speed, high-accuracy DAQ on the PCMCIA bus. Even at 10-times oversampling you can achieve 15-20 kHz of response with nice line resolution in the FFT. My experience with the PCMCIA bus has shown a wild variation in DAQ bandwidth (IBM/Compaq...the PITS -- Dell...the best ; and , no I do not work for Dell). For signal conditioning, I use SCXI (so I can not comment on the use of the other components). If you can live with interchannel skew, the set up looks quite promising. Our DAQ requirements demand the use of simultaneous sample-and-hold (SCXI 1140) for either two-channel hot-film measurements or multiple sound pressure measurements with precise cross-correlation (to eliminate wave reflections and e
chos within the test article). Our microphones were developed by NASA for use in VERY HIGH temperature environments, so our signal conditioning ahead of the 1140 is made from custom devices.
2. It is important to note that any toolkit add-on to LabVIEW "could" be written by the end user using the very same subVIs distributed with the Full Development System. Sound power is merely a term used to describe a particular mathematical method involved in transforming the acquired sound data from the real domain to the frequency domain. The mathematical methods have been used for many decades. I use my own custom code originally developed in FORTRAN, converted to C++, and now embedded in a code interface node (CIN). The issue to resolve comes down to a) do you have the in-house capability to write and support detailed code development, or, b) do you purchase the toolkits and thereby achieve the capability very quickly. Although the toolkits are expensive, the burdened cost of, say, 1
additional highly-skilled employee could cost 20 times as much. -
USMM: System Measurement
Hi,
System: ECC Development
When we run the Transaction USMM to check the System measurement, the log is not displaying the Enfine details for PO, Sale Order, Contracts, WM.
Howvever, we get all the user level details like Users with SCCR key, different user types, the clients in the system, the installed components.
Its just that Engine measurements for FSCM, WM, PO, SO, Contracts are not displayed.
My question is:
Are the Engine measurements done even for Development environment or is it displayed only for Production environment? FYI, We are not yet live.
Cheers,
AkashHi,
usmm in ECC 6.0 displays all the data, the order is below. If you can't see the data, check the background jobs related to it are completed.
SAP Version info contails application release and SP levels
In System measurement: Statistics
Status of background jobs
List of clients
Measurement results by client (user details)
User with SSCR key by client
Automatically Excluded SAP Technical Users
0100 mySAP Human Resources
5000 Procurement Orders
5100 Sales Orders
5200 Service Orders
Employee/EHR Users Statistics
Regards,
Gowrinadh -
Need help for trying to unfreeze a message on my ical. I was trying to copy and paste some appointment info from one day to another on my ical and a message popped up saying the system responded with an error. All of my info was below the message. I can't get that message to go away or work on the ical now at all. I try to force quit ical and have shut down the computer and it still comes up. Any suggestions?
K,
Try removing the com.apple.iCal.plist file from your Macintosh HD/Users/yourusername/Library/Preferences Folder. To find that Library folder, if you are using Lion, use Finder>Go Menu>Depress the "Option" key>Library. Drag the .plist file to your desktop, and log out/in or restart.
Next, make sure that you are not connected to the internet. Then to to your Macintosh HD/Users/yourusername/Library/Calendars Folder and remove any files with "Cache" as a part of the file name. Use the same method as listed above to get to the correct Library Folder. Log out/in, or restart and check iCal for functionality. -
How to use external timebase for Two Edge Separation measurement with PCIe 6351
Hi
I am working with PCIe 6351 x series DAQ card.
counter measurements.
Here i need to measure the time/no edges between two edges. Falling to Raising of two signals.
I got the measurement with internal time base.
here i need to synchronize the measurements with external clock from the external setup.
so i need to use that external clock,timebase for the counters.
Any solution please..
Regards,
HariFirst, the VI you mention is NOT for STC timer/counters. Therefore, it won't work.
If you want to get the time interval between two edges, you want to use the Functions -> Data Acquisition -> Counter -> Count Events or Time VI. This will do the function you are looking for.
Mark -
I am about to buy a new computer and have noticed that the system comes with Windows 8. I have Photoshop CS6 for windows 7.
I would like to know if this can be loaded on the new system? and what steps I need to take to ensure it functions correctly.Windows 8 meets Photoshop CS6 system requirements, see the link below
System requirements | Photoshop -
Unit of measure with language Key
Hello Guruz,
WHile creationd of purchase order, there is a check kept which compares the vendor communication language which gets updated in the Po header - Communucation tab with Db table T006A which holds the Unit of measurements with Language Key and pops up an error message.
It cheks the order unit in the PO, and the T006A whether the unit is maintained in the Language key as in the PO header - Communiction tab.
But while creating a unit of measurement in CUNI, we dont have the option to maintain the language key for the UOM.
In CUNI, it defaults the language key as EN in table T006A.
I need a prompt support from you guys on this issue. Please suggest how to go about with this?
Best Regards
Greg.Hello,
When i am trying to go for the language key in CUNI, it says that the said language is 'not available in server'. I guess it is checking whether the language patch is updated in the server.
But it doesn't sound logical to maintain all the unit of measurements in all the vendor languages. Suppose if we are having vendors with 75 communication languages and we are having 50 units os measurements, so does that mean that we have to maintain units of measurements 75 X 50 times ?
Kindly provide your inputs on the issue. We are facing lots of issues with this control kept in PO header checking for the T006A with the vendor communication language.
Regards
Greg
Maybe you are looking for
-
HOW TO EXPORT FOR MAX DVD LENGTH?
Here's my issue: I'm used to exporting my timeline from FCP using standard DV/NTSC QT conversion to then burn DVDs using DVD Studio Pro. But I can only seem to fit about an hour and 15 minutes max onto the DVD. I recently taped several long meetings
-
Saving formula results in structures
Hi, i built a structure to input values of a "profit and loss"-statement. The turnover, for example, is shown as a sum of three accounts: account description 10000 Turnover 1 11000 Turnover 2 12000 Turnover 3 13000
-
Hi all, I have a Spry.Utils.submitForm in my JS it will submit the form and then in my callback I have it clear the form element using document.formelement.reset(); The problem is, it seems that my form is getting reset before the form is submitted.
-
Customer Purchase Order Number in line item and F.27
Hi Experts. I was just wondering if its possible to populate customer purchase order number (entered in sales order) in line item, so that I can use in customer statement in F.27. The requirement is to populate customer purchase order number in custo
-
Hi there, Well, it is mysterious - not to say frightning ! When I first start my tomcat I get an Exception like:; Could not load com.sun.xml.messaging.saaj.soap.Envelope The second time it runs well. No Exception about classloading. And the app is ni