Table property node.

Dear,
I am a beginner in using a table.
My attachment and image explain my problem.
By clicking the left mouse key, the cell background color can be changed.
This color is used as three states contoller.
A string in each cell represent the state of the color. (1:1 corresponding with color).
My problems are
1. I didn't write to modify the cell position. But some cells are moving horizontally(by 2 or 3 column) in one row.
One of attachement explained the snapshot of the problem.
2. In real time, I want to update the state string in active cell. the property node result, "Set cell value", is strange.
    Of course, I tried to update whole table by using shift registered array.
   But, only deactivating the cell by moving the activation to other cell, the string was updated.
3. I want to use the table as a indicator: I want NOT to write some string in any cells of the table.
As I mentioned, some mouse clicking is preferred. How can I do?
Attachement: 1: LV8.0 code, 2: snapshot image
메시지가 04-14-2007 02:17 AM에 labmaster에 의해 편집되었음
Attachments:
bbb.PNG ‏35 KB
table.vi ‏53 KB

Hi Labmaster,
This is an interesting issue, and something that I am going to investigate further. It appears to have something to do with using the invoke node to change cell values within an event structure that is not working. I tried putting a one button dialog box inside that event case to let the user know that the event had fired, and interestingly enough the value changes then. This is likely a LabVIEW bug of some kind.
By the way, you have some funky effects going on in that table!
Best regards,
-Sam F, DAQ Marketing Manager
Learn about measuring temperature
Learn how to take voltage measurements
Learn how to measure current

Similar Messages

  • Question(s​) about the Active Cell:Posit​ion property node for a table control

    Hello,
       What determines the Active Cell Position property node for a table control? I have this in my code and I am displaying its value to a front panel indicator. The value displayed is always set to 0,0. The help for the property node say that it is "read -only" so what sets the value of Active Cell Position  for a Table Control?
    Regards,
    Kaspar
    Solved!
    Go to Solution.

    You set the active cell with a property node.  Once you select an active cell, you can do specific things to that cell and that cell alone, things like set the background color.
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines

  • Using a property node of a menu ring to generate a secondary address does not work in a subvi unless the subvi has been or is opened. Why?

    I am writing drivers for third party equipment using LabView 6.1. I am using the property node, digdisp.text, to get the item number of menu ring. This number is being used as the GPIB secondary address for the equipment. This vi is one many subVIs like it in a main vi.
    The only way the main vi works consistently is if I open all the subVIs, otherwise the secondary address isn't picked up and I get a EARG and ENOL error in NISpy and a GPIB write error in the Error Out cluster.
    I have attached an example of a NIspy capture of a failed attempt.
    Attachments:
    Capture.spy ‏9 KB

    Hi,
    EARG (4)
    Error Condition: Invalid argument to a function call.
    Description: EARG results when an invalid argument is passed to a function call.
    Possible Cause: The following are some examples: you call ibtmo with a value not in the range 0 through 17 (possible timeout values correspond to a table of values ranging from 0 to 17, where the default is 13, which represents a 10 second timeout); you call ibeos with meaningless bits set in the high byte of the second parameter; or you call ibpad (or ibsad) with invalid addresses.
    The reason you are getting the error is because not only is your secondary address invalid, but your primary address is also invalid. Lines 14 and 16 of your attached NI-SPY capture set
    the primary address (ibpad) and secondary address (ibsad) respectively. You need to make sure that you are passing the addresses properly to the subVIs using a connector. It seems like your programming when sending and receiving data (like the addresses) from your subVIs is not correct. You have to be sure to pass the data back and forth in the proper method using connectors.
    A.S.
    Anu Saha
    Academic Product Marketing Engineer
    National Instruments

  • Can we change the property of each element of an array using property node or by other methods?

    Hello all,
    Can we change the property of the elements of an array. For example:
    I have an array of combo-boxes. Can i have such a scenario that different combo-boxes of the array will have different items to select an item.
    I am able to set the different "values" in different combo-boxes bu using "to be more specific class" property node.
    But i could not set the different item list in different combo-boxes.
    Please give me the solution.

    Thanks a million dave!!!!!
    I have learnt a very new and innovative thing...
    I just wanna ask you one more question in the above context.
    Can i have listbox or combo-box in a table just like in an excel sheet where we can have listbox by using "data validation" property for different cells having different list.Can i have this in labview. Because for this i have to super-impose the combo-boxes on the table and treat them separately.
    We have to take those combo-box values and put in table and then store it.I have attached one VI to show the scenario.
    And this is the alternative solution of the array problem which u have already given. So please suggest me between the two or any alternative solution.
    Thanks,
    Ankit Madaan
    Attachments:
    Recording _Table.vi ‏19 KB

  • Working with "property nodes" in pda module

    Hi,
    i already know that it is not possible to work with property node in pda module.
    I have found something that allows to replace the visible property node
    (LabVIEW_PDA_Module_Property_Additions), but i need other property
    nodes.
    I need the following property nodes:
    disabled
    caption.text
    numrows (for a table control)
    numcols (for a table control)
    colhdrs[] (for a table control)
    Can anyone give me a help with this?
    Thanks,
    Pedro

    I think the only one you can do something about is the caption, which you can try to replace with a string indicator.
    Try to take over the world!

  • I get error 1055 "Object Reference Is Invalid" when I try to write to a property node

    Hi, I'm trying to get these results to be displayed in two tables now, where I originally had them being displayed in just one. Outside of the attached vi, I can just copy the value property from one table to the other after this vi has run, and the table values appear properly. The problem with that is, that any table property I assign (changing background colours to be exact), is not considered part of the value property, and thus isn't copied when I copy the value from one to the other.
    The thing I can't understand is that the second set of property nodes (at the bottom), give me the "Object Reference Is Invalid" when I added them. I've tried everything I can think of, but can see no logical reason why I get that error for those two, while I don't get the error for the top two (not wired to constants).
    Any help on this would be much appreciated. Thanks
    Geoff
    Attachments:
    Table Display Testing.vi ‏396 KB

    The logical reason that you're getting that error is that you are not passing in a reference to Table In Two. The control is not wired to the connector pane so you are not getting a reference from the calling VI.

  • Ni aplication ni property node

    Tengo el labview 5 y no se que le pasa o si es que no esta completo pero ni
    tiene el aplication builder ni tienen lo de las property node. Así que no se
    ni como hacerlo ejecutable ni poner las barras de desplazamiento arriba
    cuando se abre la ventana.
    ¿tengo que actualizarlo?
    ¿donde?
    ¿gratis?
    ¿y luego que?
    Se que pregunto mucho pero es que no tengo muchos conocimientos de labview y
    me han mandado un super proyecto y por ese os pido ayuda.
    Ante nada muchas gracias por ayudarme.
    Un saludo.

    Enrique wrote:
    > Well, if somebody ask in russian, I'll expect you to answer that
    > question.
    >
    > Have confidence in others. I read your answers. If somebody ask a
    > question in other language and you answer it, I have the confidence
    > that you are doing your best, because you already prove it. Also,
    > chances are there will be another person who also knows and will
    > assist.
    >
    > I don't think language should be a reason to not give a good advise.
    > We live in a diverse world, there are people who don't know english
    > but use LabVIEW. Most times is not convenience, is a real necessity.
    Enrique,
    Great, I'm doing so, but you have never seen russian language in the
    group, isn't it?
    I'm not a technical support, just an engineer.
    I'
    m using this group not for these reasons, but searching for good ideas
    and unsolved troubles worth to be solved by myself (selfish way). I'm
    trying to be absolutely confident this way, but want to understand
    everything people speaking about, sitting around the same table. This is
    the reason I'm trying not to speak russian here. Doing it outside.
    I want to close this many-times-rised issue. Sorry for bothering you all
    with my poor english. Please, arrange foreign language questions with
    language remarks for me to skip them initially. Hope, that this will be
    suitable compromise.
    Sergey Krasnishov
    Automated Control Systems
    National Instruments Alliance Member
    Moscow, Russia
    [email protected]
    http://acs.levsha.ru

  • What is difference between local variable and property node ?

    What is difference between local variable and property node ?
    " 一天到晚游泳的鱼"
    [email protected]
    我的个人网站:LabVIEW——北方客栈 http://www.labview365.com
    欢迎加入《LabVIEW编程思想》组——http://decibel.ni.com/content/groups/thinking-in-labview

    To make things clear, here are two small examples that show how nasty locals and value properties can be to the naive programmer.
    - Open the diagram of the race condition.vi before running it and try to predict what will be the values of the two counters after the third run.
    - Use the Compare Locals Properties and Wires.vi to find out how slow locals and value properties can be (times 1000+).
    This being demonstrated, I must add that I use globals and value properties quite often, because they are often very convenient
    Chilly Charly    (aka CC)
             E-List Master - Kudos glutton - Press the yellow button on the left...        
    Attachments:
    Race condition.vi ‏9 KB
    Compare Locals Properties and Wires.vi ‏18 KB

  • Is there a way to reference the property node value of a control in another VI?

    Let's say that I have a situation like the one shown in the attached image.
    I have an interlock system which is basically a bunch of booleans
    If for example the "RF Enable" button in the "interlock VI" is true, then I should be able to flick the ON switch in my other VI (in the back), but if the value is FALSE, then it shouldn't allow it.
    In other words, how do I check the value of a control across 2 separate VIs (running simultaneously)?
    Thanks!!
    Attachments:
    sample.jpg ‏295 KB

    Is one VI launched by the other, or are they launched independently? If it's the former then you just need to pass the control reference to the subVI via terminal node. If it's the latter there are a variety of ways to handle this:
    Use a global variable - somewhat "sloppy" as it requires a global variable, and can lead to race conditions. In the "Interlock" VI you just set the value of the global variable when you change the value of the Boolean. In the other you're just reading it.
    Action Engine - Ben wrote a Community Nugget a while back. Similar concept to a global variable.
    Queue - The "Interlock" VI simply pops an element onto the queue with the value. The other VI just monitors the queue for a new element. It just needs to have something like a shift register to keep track of the last state.
    Use the VI Server to access the controls of the "Interlock" VI. You can do this by accessing the "Interlock" VI's pane and get the control references. With the control reference you just need to get the value with a property node.
    ... (I'll let others chime in)

  • Is it better to use Invoke nodes or property nodes to set/get control values?

    I have a series of VI's that run in parallel, each to manage different functions- pumping, sensing, a fluid flow model, an experiment generator/runner.
    These need to exchange data, which I am currently doing using invoke nodes (that are all in subVIs), using methods "Set control value" and "Get control value". I find that every now and then (perhaps 1% of the time) the data isn't exchanged correctly and therefore the system doesn't work. I can imagine how "set" could go wrong if they happen simultaneously, and can devise ways of preventing this. However, the "Get" method suffers from the same problem. This is a major problem, because I want to leave it running for several hours.
    I could in
    principle achieve the same thing using property nodes and find myself wondering if this might be more reliable. But I don't want to change over only to find it makes no difference!
    Can anyone advise?

    You can use some kind of syncronization such as queues, occurances, or notifiers but I think the easiest way would be to create and action engine. This was only one action can execute at a time avoiding a "race condition". Possibly a write action and a read action might help. You also can add queues or notifiers into this concept. hope this helps.
    BJD1613
    Lead Test Tools Development Engineer
    Philips Respironics
    Certified LV Architect / Instructor

  • Just checking on another odd feature: Typedef enum Property Node "Value" not reflecting changes in the Typedef?

    Just encountered this odd behavior in LV 2011 which I reduced to the following example:
    - create a new VI and drop an enum control on te FP.
    - make this control a typedef and open the corresponding typedef
    - create a "case 1" item and a "case 2" item
    - save the typedef (I used the name Typedef Control 1) and CLOSE it (this is to allow updating of the original control).
    - drop a case structure on the diagram and connect the enum to it:
    So far so good. Now create a "Value" Property node for the enum and use it instead of the terminal:
    If I now go back to the typedef and add a "case 3" item, save the typedef and close it, the control is updated, but the Property node is not.
    How do I know that? For one, the Case Structure contextual menu does not offer to create a case for every value. Also, if I add a "case 3" case manually, it turns red.
    Luckily, the magic Ctrl-R key stroke actually does solve this problem.
    Tested in LV 2011.

    By Ctrl-R trick do you simply mean running the VI?  That is one way to force a recompile, but if you hold down Ctrl while pressing the run button you can recompile without running.  This should not be "dangerous" in any situation.
    As you have drawn your example, I see no reason not to use a local in that situation (ok, maybe for vanity).  Still, I view the behavior you describe as a bug, and it should certainly be fixed for the benefit of local haters out there.  You have to be a little careful where you draw the line between what gets handled in real time and what gets handled only at compile time.

  • NI 845x USB: Error -301713 occurred at Property Node (arg 2) in General I2C Read.vi

    Hello,
    I am currently working  with digital accelerometer LIS35DE from ST Microelectronics. I want to start with tests of this device. For that purpose I used NI 845x USB to connect with accelerometer via I2C. Unfortunately, when I made electrical connections and set up parameters of communication and run the program (I found it in examples) the following error occured:
    Error -301713 occurred at Property Node (arg 2) in General I2C Read.vi
    Possible reason(s):
    NI-845x:  An input parameter, or combination of parameters, is invalid. An example of this error may be setting an invalid baud rate or enabling I2C ACK polling while using 10-bit addressing.
    The code can be found in attachements. I couldn't find any extended description of this problem. What could be a problem: incorrect device address, register address, configuration parameters?
    Any help is appreciated!
    Best regards,
    Michael
    Attachments:
    General I2C Read.vi ‏24 KB

    Hi MicMac89!
    First of all could you please post which version of LabView are you using?
    Could you please tell me which version of 845X hw are you using? (8451 or 8452)
    I opened the example you attached. As you wrote the error occurs at the second argument of the property node. (I guess this is the first property node where the error occurs.)
    This argument of the property node enables the onboard pull-up resistors. But not all NI-845x hardware support pull-up resistors. (Because of this is important to know which hw version are you using.)
    Did you try the example with disabling the pull-up resistors?
    I suggest you to go through the Manual of this product, (if you did this not yet) This could make it clear where and when to use what kind of pull-up resistors.
    For example: If you are using 8452, you must enable pull-up resistors, for Vref ≤ 1.8 V for the FPGA to properly detect a low-to-high transition
    Manual: http://www.ni.com/pdf/manuals/371746d.pdf
    HW specification: http://www.ni.com/pdf/manuals/290598a.pdf
    Please post if my suggestions helped. Of course if you have any questions, don't hesitate to post them.
    Best regards, 
    Balazs Nagy

  • Error 1073807202 occurred at Property Node (arg 1) in VISA Configure

    I am working with the 30-day evaluation version of LabVIEW
    (Version 9.0 32-bit).  I am attempting to perform the serial loopback test
    described in NI's Developer Zone Tutorial, executing Basic Serial Read and
    Write.vi.  When I click the Run arrow a dialog box appears with the
    following legend:
    "Error 1073807202 occurred at Property Node (arg 1) in VISA Configure
    Serial Port (Instr).vi>Basic Serial Read and Write.vi.  LabVIEW: VISA or
    code library could not be located.  ...required drive not installed..."
    I can find the "smplserl.vi" driver in the /examples folder on my PC.
    What's wrong?

    Did you do a search for that error? Install NI-VISA.

  • Error 1055 occurred at Property node

    Generating the error:
    "Error 1055 occurred at Property Node in ...   Possible reason(s):  LabVIEW object reference is invalid."
    when I try to wire the IMAGE OUT output from the IMAQdx Snap vi to the value property of an externally referenced image display control.
    To describe in more detail, I have a parent vi with an image display control and a child vi which has a control refnum linked to the parent vi display. In the child vi I create a value property for the refnum and try to write images to it, essentially to drive the parent display from the child vi.
    The technique works elsewhere, though I can't think of what I could have done differently to generate this error?

    Hi Mike - looks like I may not need to. I've been working away at this and have found the original cause and something else a bit weird...
    I deleted the objects from the sub-VI that was giving me errors, then cut and pasted the objects (image display refnum and value property) from a VI that was working and this solved the problem. So you might think that the issue was just some obscure configuration item, or I'd used the wrong type in my reference or something.
    I found the display reference in the parent VI was not even wired to the sub VI - duh! Error between keyboard and chair. So at least the original error message made sense, but I have no idea why it actually worked after pasting in the new objects. Are these references using some sort of auto-magic? Who knows. Safer to wire up my sub-VI's properly methinks.
    Sorry for wasting forum time on this one.

  • How to show/hide sliders on a slider control using property nodes?

    If I have a slider with multiple sliders on it how do I change which sliders are visible using property nodes? The only property I have found is making the entire control to be visible or not.  This is a possible solution to have two different controls, one slider with only one slider and another slider with two sliders overlapped, but not desirable.
    I found on a thread in the forum that it is possible but the user did not provide any specifics about which property it was. (http://forums.ni.com/ni/board/message?board.id=170&message.id=181279&query.id=34404#M181279)
    I would appreciate an example VI if possible (Preferred version is 8.5 but versios 8.2, 8.0, and 8.6 are available to me).
    Thank you in advance for the help,
    Aaron

    Just make them transparent! Here's a quick draft.
    LabVIEW Champion . Do more with less code and in less time .
    Attachments:
    HideSliders.vi ‏20 KB

Maybe you are looking for

  • Warning  6226: Ignoring value requested for first connection attribute 'TempSize'

    Hi Was trying to load, here is what I see. Appreciate your help. con1: Command> load cache group g_sdata_awt commit every 1000 rows; 5056: The cache operation fails: error_type=<TimesTen Error>, error_code=<3407>, error_message: [TimesTen]TT3407: Can

  • CS Live Services Update Failed

    I'm trying to update my CS5 CS Live Services Update, but everytime I try it gets 2 seconds in and gives me an error. I've tried to read other discussions, but I'm not that tech savvy and I don't know what to look for to solve the problem. InDesign cr

  • Copy and Paste Variable Speed Ramp Curves?

    Is there any way to copy and paste variable speed ramp curves from one shot to another. I've got a rough cut with lots of speed ramps, and now I have to conform renders that came back from Color (pre-prepped with out ramps) to the offline with the sa

  • Can't Preview error

    I'm getting a "Can't Preview" error. The preview bar gets halfway through then up comes the error. The weird thing is there's nothing exciting in the book - a single chapter witha  few sections, and some images.  No interactives, no widgets No explan

  • Ipod ... no response at all