Tables While Creating Info Object

Hi Experts,
What are the tables created when we create and activate an Info Object. I Came to know that it will create 11 tables when we activate an Info Object what are they It was my Intv Question. are these 11 tables created automatically or with the user specifications?
Elaborated Answer will be awarded with points.
Krish

Hi
         The number of tables depends on the charecteristics of the infoobject selected. if it has time dependent attributes or hierarchy
suppose an infoobject is product then we could have the following tables
•     Product hierarchy table: /BIC/HProduct
•      Product hierarchy SID table: /BIC/KProduct
•      Product SID-structure hierarchy table: /BIC/IProduct
•     Product master table for non-time dependent attributes (table name: /BIC/PProduct)
•     Product master table for time dependent attributes (table name: /BIC/QProduct)
•     Product SID table (table name: /BIC/SProduct)
•     Product non-time dependent attribute SID table (table name: /BIC/XProduct)
•     Product time dependent attribute SID table (table name: /BIC/YProduct)
Thanks

Similar Messages

  • Error while creating info object

    error while creating info object a character
    Info object may be a maximum of  000060 digits...... what would be the error?
    Thanks ALL

    Hi,
    The maximum length supported by one CHAR type infoobject is 60. Check whether you have assigned more.
    If you have to load more length ( more than 60) split the total thing into different infoobjects. Create different infoobjects and split the total thing into them - like 1st 60 char in 1st infoobject, char 61-120 in 2nd infoobject and so on. Then you can again concatenate them.
    Thanks,
    Indrashis

  • Error while creating Info Object in Info object catelog

    Hi experts,
    I'm making few info object in info object catelog but while activating system giving error mesage as "Error when generating master data routines"
    can any one tell what's the problem and what needs to be done.
    Sumantra

    Hi
    let me know weather r u using any reference object which contain the routinee.
    regards,
    chandra.

  • Version error while creating info package of data source 0fi_gl_10

    Dear Friends,
    I have replicated the data source 0fi_gl_10 into sap bw but while creating info package i am getting error " The DataSource 0FI_GL_10(E01CLNT200) does not exist in object version A". IS the manual activation always should be done for that ?
    Regards
    Nilesh

    Hi,
    Please check if the veriosn of DataSource is A or not. Sometimes it shows as active but if you open the datasource then it might be in modified version only. Do activate it manually, it will serve your purpose to create a infopackge.
    Regards,
    Anjum.

  • Error while creating Info Spoke....

    Hi,
    I am facing one problem while creating Info Spoke.I have 4 DSO which included in one Infoset & that infoset incluede in one Multiprovider. I want to creat info spoke on this Multiprovider.But when i changed the tab or at time of save & activate it gaves me error as "InfoObject ZCGNCRM2___F100 is not available in version A". I checked this info-obj.its already in active version. I reactivate it.I reactivate infoset & multiprovider also.But still exist this error.
    Please suggest me any solutuion.

    Hi Sandeep,
    Check this info object is included in any of your DSO or Info set and Multi provider.If yes check all are active or not.
    activate the info object once again using program RSDG_IOBJ_ACTIVATE and activate your Info spoke
    Check below article
    http://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/f0d48577-9542-2e10-05a1-d6c1e07ea641?quicklink=index&overridelayout=true
    Regards,
    Venkatesh

  • What are the naming conventions we should follow while creating an object

    hi
    what are the naming conventions we should follow while creating an object in ABAP dictionary, i.e while creating zee table.

    Hi,
    Namespaces and Naming Conventions
    SAP has reserved name ranges for customer objects and SAP objects. Use these customer name ranges to make sure that your objects are not overwritten by SAP objects during the import of corrections or an upgrade.
    This documentation lists the customer name ranges for the different system objects.
    Only use the customer name ranges. If you do not keep to the name ranges for customer objects you may lose your development objects.
    SAP delivers a few system objects with names that fall within the customer name range. These objects already existed when the customer name range was extended from YY/ZZ to Y/Z. These objects are listed in table TDKZ.
    Regards

  • Linker Error while creating shared object.

    While creating shared object we got "file processing error".
    Below is our compilation line and the error out put.
    ==================
    /net/icom3/opt//SUNWspro/SC5.0/bin/CC -o fn_ctx_onc_fn_files.so.1 -G -h fn_ctx_onc_fn_files.so.1 -z text -z defs -z combreloc -norunpath -nolib -Qo
    ption ld -R/usr/lib/fn pics/FNSP_filesOrgContext_default.o pics/FNSP_filesFlatContext_default.o pics/fnsp_internal_common.o pics/FNSP_nisAddress.o
    pics/FNSP_nisOrgContext_default.o pics/FNSP_nisFlatContext_default.o pics/FNSP_hash_function.o pics/FNSP_filesHierContext.o pics/FNSP_filesDotC
    ontext.o pics/FNSP_filesFlatContext.o pics/FNSP_filesHUContext.o pics/FNSP_filesWeakSlashContext.o pics/FNSP_filesPrinternameContext.o pics/FNSP_
    filesPrinterObject.o pics/FNSP_filesOrgContext.o pics/FNSP_filesImpl.o pics/fnsp_files_internal.o pics/onc_fn_files.o -lnsl -lc -L/user/vts/X
    FN_CHECK/jnk/usr/lib/fn -lxfn -lfn_spf -lfnsp -lfn_p
    ld: fatal: File processing errors. No output written to fn_ctx_onc_fn_files.so.1
    ==================================
    Thanks in advance.
    -Lokesh MS

    Hi,
    The maximum length supported by one CHAR type infoobject is 60. Check whether you have assigned more.
    If you have to load more length ( more than 60) split the total thing into different infoobjects. Create different infoobjects and split the total thing into them - like 1st 60 char in 1st infoobject, char 61-120 in 2nd infoobject and so on. Then you can again concatenate them.
    Thanks,
    Indrashis

  • Error while creating Temse Object (W2 form in PU19)

    Team,
    When i try to create the w2 in PU19, i am getting the error statingthat ERROR WHILE CREATING TEMSE OBJECT HRLUS01A100900109026.Please advise me in this.(We are maintaining the HRSP-42).It is veryurgent,Expecting your valuable Guidance.Points sure for the answers.
    Regards
    Priya.K

    Hi
    let me know weather r u using any reference object which contain the routinee.
    regards,
    chandra.

  • Error while creating PDF object

    We are using Adobe Interactive Forms with Guided Procedures.  Netweaver 7.0 SP14 (Dual stack Java & Abap).  All was working well it appears until we configured SSL for ADS - don't know for sure if this caused the problem but it is the only change we can identify around the time that our problems began.
    When we attempt to Create an Impersonalized Form we receive the following error -
    Cannot retrieve template structure: Execution ended in an unrecognized state
    When we attempt to test a callable object associated with an interactive form we receive -
    Error while creating PDF object: PDF object could not be created; object returned from ADS is null.
    In both cases the entries in the default trace log are the same -
    Service XMLFormService: Native process (PID=0) /usr/sap/UFD/DVEBMGS02/j2ee/os_libs/adssap/XMLFormService/bin/XMLForm.exe terminated abnormally with error code 134
    PDF object could not be created; object returned from ADS is null
    com.sap.caf.eu.gp.base.exception.EngineException: PDF object could not be created; object returned from ADS is null
    at com.sap.caf.eu.gp.model.iforms.adapter.pdf.AdobePDFAdapter.createInstanceDocument(AdobePDFAdapter.java:542)
    at com.sap.caf.eu.gp.model.iforms.preproc.FormPreprocessor.execute(FormPreprocessor.java:507)
    Like I mentioned earlier this functionality was working successfully in our environment at one time.
    Any guidance in this matter would be greatly appreciated.
    Thanks,
    Joe

    Joe,
    If you originally configured ADS without SSL, I would recommend going back through the ADS Configuration Guide for your NetWeaver stack and make sure all the necessary changes for SSL were made.  I've seen another case where a step was missed in SSL configuration for ADS which caused a form to error.
    If everything looks good based on your SSL configuration, I would recommend creating an OSS Note.
    -Matt

  • How to create an ods after creating info objects?

    Hi,
    Please Explain me How to create an ods after creating info objects with all screenshots in BW 7.0?
    Thanks,
    Jini

    Hi Jini,
    In the create screen u will find some settings related information which u need to check and then there are key fields and data fields option.
    In Key field u need to include those objects which should make ur ODS Key fields. and then rest of the fields in the data fields.
    For setting related information u can search in help.sap.com or even on SDN threads.
    Thanks,
    Nagesh.

  • Create Info objects after extracting ds from ecc

    Hi All,
    I have replicated ds from ecc to bi and executed the infopackage. Now the data is upto psa level. How to create info objects after loading data to psa level to load the info objects to data targets like infocubes and dso. I have done to sucessfully to a flat file.
    Thank you.

    Hi Sudhir,
    You can go into 2 directions: use as much as possible Business Content InfoObjects or use custom InfoObjects. A combination is also possible.
    Especially in conjunction with SAP ECC extractions the Business Content InfoObjects are a safe choice. However, please consider the advantages it can have to use custom InfoObjects.
    If you would like to go into the direction of custom InfoObjects, then I suggest reading the following blogs:
    Generating Data Warehouse InfoObjects - Part 1: Introduction;
    Generating Reporting InfoObjects based on Business Content - Part 1: Introduction.
    Best regards,
    Sander

  • Updating the VETVG table while creating the purchase order

    hi all,
       I have one requirement to calculated the delivery creation date while creating the Purchase Order. It is calculated based on the delivery date of PO. I have calculated that one but how to update it after calculation. Can any body give a user exit or BADI with implementation which will update the VETVG table while creating the PO.
    Thanks
    rajkumar

    hi sanjay,
    thanks for reply, I am using same BADI(ME_PROCESS_PO_CUST) and implementation(FIELDSELECTION_ITEM_REFKEYS). In this implementation i am setting the shipping data with SET_SHIPPINGDATA method . but after that the values are not updating the EKPV and VETVG tables but it is only showing in the screen. Can you give a idea where to pass these values so it will update the tables.
    thanks
    rajkumar

  • Hi All, which is better while creating an object

    Hi All, which is better while creating an object,
    for ex:
    public class Joe {
    public void disp() {
    System.out.println("Joe.disp");
    (1) Joe j = new Joe();
    j.disp();
    (2) new Joe().disp();
    of course, both are equal, which is better in performance perspective

    I suggest you just write code and when the assignment is done, AND you have a performance issue, only then try to improve things. The question you're asking now is likely of no relevance to the performance of you application.
    You can run your application through a profiler to see what specific part of it is consuming (too) much memory.

  • Update mode options while creating info package

    Hi all .
        while creating info package in update tab  we have different radio buttons as
       FULL UPDATE,DELTA UPDATE,INTIALIZE DELTA PROCESS. could you pls explain this optons.
    Thanks in advance.
    Cheers,
    sami.

    Hi Sami,
    We have two update modes 1)Full update 2)Init Load(to enable delta)
    Full Load --->Master data Load
    Init Load----->Transaction data Load.
    Full Update-To load Historical Data.
    Init-This is done to enable the Delta Upload.
    Delta will be done only if the Init has happened.
    For deltas they are Data source specific which are delta enabled.
    1. Full Load (Extracts whole data available in source)
    2. Initialization (without data transfer): Enables only delta and no data.
    3. Initialization with data: Extracts whole data from source and enables delta.
    4. Delta: Extracts only modified or new data.
    Above modes works for Master as well as Transaction also.
    For further information check this link:
    http://help.sap.com/saphelp_nw2004s/helpdata/en/80/1a65dce07211d2acb80000e829fbfe/frameset.htm
    Cheers,
    Tanish.

  • Transfer rules are mandatry While creating Info source

    Hello BI Guru's
    Is transfer rules are  mandatry while creating Info Source in BI.
    Please currect me if i am wrong.
    I have created one genric extracter and want to create info source for that in BI and planning to create Transfermation btween Datasources and infosource and from info source loading data target through transfermation.
    Please advise me which way is best way to follow the desing?

    hi,
    in BI 7.0 transfer rules and update rules are not mandantory,
    DataSource -> Transformation -> (DTP)-->Data Target
    instead of TR/UR-- transformation is there
    if helpful asign points
    regards
    harikrishna.N

Maybe you are looking for

  • HT202157 my apple tv is wont start how can fix it

    hello my apple tv is not working and the light is off i tried to appdate it but it says on my computer that it has an error

  • Error code=12052

    im trying to update my Nokia N8-00 mobile, i cannot install the (BELLE SW) according to error code= 12052. what to do ...

  • Status 29 in ALe Idocs

    Hi All, Recently I've come across a problem in ALE Idoc. The status of the idoc is 29 Error in ALE service. This kind of error is encountered when there is a configuration problem in either Partner profiles or Port definitions. The Partner profile is

  • What happened to Photoshop CS 5.1 trial download?

    Sunday evening I went to the Adobe site to download the trial version of Photoshop CS 5.1. In three tries I got the message that the disk image could not be opened because of an invalid checksum. This morning I went back and again clicked the link to

  • Migrate database 10g 32bit to database 10g 64bit itanium (windows 2003)

    Hi How i can migrete 10g(32bit) to 10g(64bit itanium) ? I have cold backup and hot backup. How i can do this? Thanks for advance