Good Day,
I need your advices about this problem in TDMS Postprocessing:
At last i finished the "Phase data transfer" and i continued to the next phase, on execution of the activity "Res
Internal Header Tables After the Transfer" i get this error:
Phase 'Postprocessing' of activity_id 'Reset Internal Header Tables After the Transfer' differs from active phase 'Data Transfer' in package 90002
How to set manual the parameter or how to make this work =) ?
with best regards,
Anatolii

Hello,
I think there is some confusion. "Define mass transfer ID", "Run Database analysis", "Define conversion object" and "Generate conversion object" are the activities belong to the System Analysis phase but not Data transfer phase.
Are these activities successfully executed in the system analysis phase ?
what about the define mass transfer id ? is any exeuction completed successfully ?
Can you check again. Just verify that all the activities under system analysis and data transfer should have completed successfully. If its fine then you can change the phase as
guided by Rui above.
Best Regards
Niraj

Similar Messages

  • Access files (ascii and TDMS) by blocks, step by step

    Whener I perform a data acquisition and save the data I save to files (either ascii or TDMS, depending on acquisiton length, sampling rate, etc).
    Afterwards, when I want to access the data, the only way I have managed to is by reading it all at a time. And so, I have to turn to other softwares such as MatLab for postprocessing. And also, if files are bige enough, I sometimes have memory related troubles when reading complete files.
    I would like to know how to, because I am sure it can be done, how to do a loop for reading files by blocks, step by step; conrolling file position, block length, etc.
    Regards,
    usuario

    You may want to read Managing Large Data Sets in LabVIEW.  It walks through many of the issues you are facing here, although it is a bit dated.  After you read that, also read the LabVIEW help on the In Place Element Structure and the Data Value Reference.  Approach both with caution, since both break data flow (i.e. can be a potential race condition), but they help when dealing with copies of large data.
    Text files can be read incrementally by either line or character.  Since the ideal block read size for a Windows file system is about 65,000 bytes, I like to read in my text files 65,000 bytes at a time and doing any parsing from the memory buffer.  When the buffer runs out, I get another 65,000 bytes until the file is done.  <shamelessAdvertising>This method will be the subject of my next post on object-oriented file I/O, which will, unfortunately, be about two to three weeks from now, due to my "real job" getting in the way .</shamelessAdvertising>.  If you are in a hurry and enjoy complex code, the Read From Measurement File Express VI in LVM mode also uses this method.  If you open the front panel of one and dive into the code, you can see it in action.
    Good luck!  Let us know if you need more help.
    This account is no longer active. Contact ShadesOfGray for current posts and information.

  • Can't boot up in TDM mode

    My G4 will not boot up in Target Disk Mode. I've restarted it with the T key pressed three times and it just ignores it and boots up as normal. I'm running 10.3.9 on a G4 at 350 mhz.
    I'm puzzled.

    Hi-
    Are you using an Apple wired keyboard? If not, could be the problem.
    Try setting Startup Disk preferences to Firewire TDM, and restart from there.

  • TDMS: is it possible to use sender and receiver client within the same SID

    Hi all
    I have a general question about TDMS: i always read that it is possible to refresh data from a productive system/client to a test system/client, e.g. PRD100 => DEV100. But is it also possible to refresh data from one sender-client to the receiver-client inside the same system using TDMS, e.g. DEV100 => DEV200.
    i'm asking because if i start to build up a new client using tdms the first step is to build up the client using package "ERP Initial Package for Master Data & Customizing". This includes under point "data transfer" the step "lock the system" with teh following description:
    Lock System
    Activities
    During data deletion in the receiver client, the tables are dropped. All clients in the system are affected by this procedure. Consequently, all users in all clients in the receiver system must be temporarily locked while the data deletion takes place.
    The function for this activity locks only the current client. If the receiver system is a single client system, it is sufficient to execute the function. If, however, the receiver system is a multi-client system, the user in the other clients must be locked using standard means.
    Anyone has any experience with this scenario inside the same system?
    Regards
    Adrian

    You can run TDMS package on the same system and between different clients. However SAP don't recommend to run TDMS package on the same system.
    There are 2 ways to delete data in receiver system: Array delete and drop insert.
    You have to use Array Insert only which is usually very slow as it first select all the relevant entries from the tables in the target client and then drop it. So, it is slow.
    Drop insert is much optimized and fast but the same can not be used in this use case.
    That is the reason SAP don't recommend to have TDMS run in same system.

  • USB 6009 and TDMS write

    Dear all!
    I'm using USB-6009 device to adquire data from a physical channel. In the following vi, the number of samples to be adquired is set to 1000, with a 100Hz rate. Therefore, as I understand, the number of samples that should be read inside the while loop where DAQmx read is placed should be 10 for each iteration. However, I've tried to store this information in a TDMS file and I'm getting less number of samples as expected. I wouldn't like to lose any data.
    I've read overthere that the USB-6009 is a software-timed device, so, can this be the reason of this anomaly? Moreover, if I analyze the adquired samples using DIAdem software, I see some samples are being repeated. In this case, am I overwriting some data and reading past values?
    If I need to replace my data adquisition device with a hardware-timed one, which one should I get?
    Thank you very much in advance,
    Miren  
    Attachments:
    USB6009_TDMS.vi ‏25 KB

    When you run the sample clock in  "Continuous Samples" mode, the # of samples only determines the buffer size.  This is outlined in the help for that function.
    As a result, you have nothing pacing the internal loop: If there are samples available when it reaches the DAQmx Read, it passes out as many as are available in the buffer.  You might get 1, 2, 100; it depends on how long the other operations in the loop take.
    In general, DAQmx loops like this can be paced either by time or by # of samples.  Looks like you want sample pacing: wire the number of samples you want to collect to the "# of samples per channel" input of the DAQmx read.  Then the loop will wait at the daqmx read until that many samples are ready, and then it will proceed.
    -Barrett
    CLD

  • Error reading TDMS file with inconsiste​nd dt

    Hello all,
    I would like to ask your help to understand how to read a TDMS file which I am opening and closing based on a user input.  As a result the data in the TDMS file does not have a consistent time step, which may be causing my problem, but I really don't know.  I keep getting the error 2501, that I have an invalid reference. 
    Or, if I continue and bypass the error, the extract portion VI gives me an error stating that I need to define an integer multiple of dt.
    I am not sure how to solve the first point as I have the reference wired directly to the read TDMS vi.
    I have attached a screen shot of the error and the portion of the VI with the offending error (it is the code connected to the read TDMS read vi).
    My goad is to extract a portion of the data to do calculations on and display a result to the user.
    thanks for any comments.
    A. Lopez
    Attachments:
    error-2501.JPG ‏198 KB

    I think you open multiple times the same TDMS file, you should open it before the while loop. And I don't see a close tdms function...
    Also check for errors on the open TDMS function.
    Ton
    Message Edited by TonP on 02-14-2007 07:45 AM
    Free Code Capture Tool! Version 2.1.3 with comments, web-upload, back-save and snippets!
    Nederlandse LabVIEW user groep www.lvug.nl
    My LabVIEW Ideas
    LabVIEW, programming like it should be!

  • TS3775 Hi I am trying to connect my mba mid 2011 with an imac 27" 2011 with target display mode tdm. When I am using a thunderbolt cable nothing will work. When I use a minidisplay cable, both screens turn blue but eventually nothing happens. What is the

    Hi I am trying to connect my mba mid 2011 with an imac 27" 2011 with target display mode tdm. When I am using a thunderbolt cable nothing will work. When I use a minidisplay cable, both screens turn blue but eventually nothing happens. What is the problem

    Your answer is likely in Target Display Mode: Frequently Asked Questions (FAQ) - Apple Support If you are familiar with this document, please re-read it and I suspect you may find something you either missed or are doing incorrectly.

  • How can I open a tdms file and replace a subset of data then save that change without re-writing the entire file again?

    Hi all,
    Is it possible to open a tdms file and make a small change an an array subset then save the file without having to save the whole dataset as a different file with a new name? That is to say, is there something similar to "Save" in MS Word rather than "Save As"... I only want to change a 1D array of four data points in a file of 7M data points.
    I am not sure if this make sense? Any help is apreciated.
    Thanks,
    Jack

    You can use either one, but for your application, I would use the synchronous.  It requires far less setup.  When you open the file, set both enable asynchronous and disable buffering to FALSE to enable you to use synchronous with arbitrary data sizes.
    Attached code is LabVIEW 2011.
    This account is no longer active. Contact ShadesOfGray for current posts and information.
    Attachments:
    UpdateTDMS.zip ‏20 KB

  • How to get the last data point from a TDM file in LabVIEW?

    Hello,
    I am using LabVIEW to analyze some rather large TDM files, and I need a way to get only the last data point.  So far, the only way I have been able to accomplish this is by reading the entire file.  Is there a property in the TDM file or a function in LabVIEW that will allow me to get the index of the last item in a channel?  
    Thanks!
    Christina

    Do you want to avoid reading whole file and want to be able to reach or get the index of last value of channel? is there any specific reason? I am not sure you could do it without loading the whole file. But the easiest way would be just to use array functions "array size" would give you the index of last element. 
    -Nilesh
    Kudos are (always) welcome for the good post. :-)

  • Sales orders in TDMS company/time based reduction  are outside the scope

    Guys,
    I have had some issues with TDMS wheras it didn't handle company codes without plants very well. That was fixed by SAP. But I have another problem now. If I do a company code and time based reduction, It doesn't seem to affect my sales orders in VBAK/VBUK as I would have expected. I was hoping it would only copy sales orders across that have a plant which is assigned to a company code that was specified in the company code based reduction scenario. That doesn't seem to be the case.
    VBAK is now about one third of the size of the original table (number of records). But I see no logic behind the reduction. I can clearly see plenty of sales documents that have a time stamp way back from what I specified in my copy procedure and I can see others that have plant entries that should have been excluded from the copy as they do belong to different company codes than the ones I specified.
    I was under the impression that TDMS would sort out the correct sales orders for me but somehow that doesn't seem to be happening. I have to investigate further as to what exactly it did bring across but just by looking at what's in the target system I can see plenty of "wrong" entries in there either with a date outside the scope or with a plant outside the scope.
    I can also see that at least the first 10'000 entries in VBAK in the target system have a valid from and to date of 00.00.0000 which could explain why the time based reduction didn't work?
    Did you have similar experiences with your copies? Do I have to do a more detailed reduction such as specifying tables/fields and values?
    Thanks for any suggestions
    Stefan
    Edited by: Stefan Sinzig on Oct 3, 2011 4:57 AM

    The reduction itself is not based on the date when the order was created but the logic enhances it to invoices and offers, basically the complete update process.
    If you see data that definitely shouldn't be there I'd open an OSS call and let the support check what's wrong.
    Markus

  • Error 6 occurred at TDMS Open in TDMS

    Hi,
    I have a application that is using the TDMS VI's to generate a Logfile. 
    The application ran correctly for 12 days. (Each errors, and some parameters - every hours - was correctly written to my TDMS file).
    Then, the following error occured : 
    Error 6 occurred at TDMS Open in TDMS - Write data SubVI V1.2.vi->D2XX MultiTester V1.5.vi
    Possible reason(s):
    LabVIEW:  Generic file I/O error.
    =========================
    NI-488:  I/O operation aborted.
    I join my VI that manage the TDMS file. 
    The error seems to come from the VI "TDMS OPEN". The corresponding TDMS file is effectively at the specified path, and its content is OK (all expected infos are present). The file is called LogFile_0_1.TDMS. 
    Depending on the TDMS file size, the application automatically creates a new file. I tried to force that to get a new TDMS file (assuming that the active file was corrupted or blocked). A new TDMS file was created (LogFile_0_2.TDMS.) but only the first tab (root) was created. Then the same "Error 6 " was still present, exactly like before. 
    Do you think this problem can come from Windows?
    Or does it come from my application? What is not optimal, is that this "TDMS - Write data SubVI V1.2.vi" is called about every second, and the "TDMS OPEN" function is called unconditionally (even if no modification on the TDMS file are needed).
    How can we explain that this bug appears after about 12 days only? 
    I also join you the LogFile_0_1.TDMS that I converted to an Excel file, and the LogFile_0_2.TDMS that was not correctly created.
    Thank you in advance for your support.
    Michael 
    Solved!
    Go to Solution.
    Attachments:
    LogFile_0_1.xlsx ‏560 KB

    MarcoMauri wrote:
    My guess is that you forgot to close the TDMS file and each time your VI is called a reference is created.
    It could be that after a week the maximum possible number of references was reached, and you got the error.
    Regards,
    Marco
    Marco,
    That's not just a guess, that is a very real possibility.  And lets not forget the memory leaks from not closing references.
    ALWAYS close ANY references you create.  If you open a reference to a file, make sure you close it.
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines

  • Newly written tdm/tdms file not found

    Hi,
    I am trying to save some simple thermocouple data to a tdm/tdms file.  I run my vi and it seems to work just fine. I am using the NI 9213 getting started example as a basis and have added tdms open, tdms set properties, tdms write, and tdms close.  I can see the data streaming on the waveform chart but when I hit stop and go look for the saved file I can't seem to find it.  What am I doing wrong?
    Thank you
    Solved!
    Go to Solution.

    SRamirez wrote:
    I set it to create.  When I run it once for a new folder it runs just fine but if I try again I get error 6.
    You are specifying a folder?  You should be giving a full file path (like c:\temp\blah.tdms).  What you might want to do is build a file name based on the data/time.  This way you won't have to worry about overwriting files and what not.
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines
    Attachments:
    Build File Name.png ‏9 KB

  • How to compare signals from two different .tdms files?

    i'm developing a lie detection system in labview.so inorder for that i need to compare the threshold physiological signals from the .tdms file with the signals i acquire continuelsy from the subject for each question asked.i use respiration monitor and heart beat monitor together with the sensorDAQ to acuire the physiological signals.so which are the function i should make use of?i have the following toolkits
    1. advanced signal processing toolkit
    2. adaptive filter toolkit
    3. digital filter design toolkit
    4. biomedical toolkit
    please give me advise on this.
    thank you.
    Solved!
    Go to Solution.

    Lie detector systems (polygraphs) generally work by looking at the physiological responses to the own subjects baseline, and do this in real-time.  You could use a file that represents the stored "baseline" for the subject, but the overall environment, circumstances, general state of the subject, etc. may not be similar enough to easily see subtle changes.
    From the stored file, you might determine a set of parameters or thresholds that indicate "normal, relaxed" for each signal.  You could read the file into your LabVIEW program, process each channel, and save these parameters.  Then when you have the new data, you can read the new data file in and process it in a similar way and then determine whether the parameters are outside the limits that you established for a "lie".
    You may get more responses to this question if posted in the Biomedical User Group
    Visit the NI Biomedical User Group at:
    www.ni.com/biomedusers

  • How do I select more then one channel to view in tdms file viewer graph panel

    I have a TDMS file that I can view with the labview 2013 TDMS file viewer and I can select one signal out of 15 signals to view on the graph panel. however I would like be able to look at 2 or 3 signals
    on the same graph but can't seem to be able to select more then one signal at a time. Is there a way to select more then one to view?  

    I've modified the TDMS viewer in the past to allow selecting multple channels.  It's a little bit of a pain because the tree control in the viewer only allows you to select one item.  You have to edit the tree to allow multiple items.  Now your selection is an array instead of a scalar.  This means the rest of the code has to be updated, and the references to the tree in subVIs need to be updated.  Not impossible but it takes some time.  Alternativly open it in Excel with the free add-in then you can select the two columns you want and insert a graph.  Not as simple for the user but using Excel, which users should be familiar with might mean users need less training on data files.
    Unofficial Forum Rules and Guidelines - Hooovahh - LabVIEW Overlord
    If 10 out of 10 experts in any field say something is bad, you should probably take their opinion seriously.

  • How does DIADEM import TDMS files? How gets every channel his number and groupindex? How can I determine which channel has which groupindex and number?

    I store different channels in a TDMS file.
    I like to have a time channel at the first position with group index 1 and number 1.
    When I read the TDMS file with DIADEM the time channel (Float64) is on a differernt position, and the channels are not sorted alphabetically.
    Here are my questions:
    How does DIADEM import TDMS files?
    How gets every channel his number and groupindex?
    How can I determine which channel has which groupindex and number?
    Best regards
    Joerg

    Hi Jörg,
    i suppose that you´re programme whose create the *.tdms file is writing on false position. Try to create datas with timechannel on first indes in diadem, then save it and then open it again. you see that all is correct. So please tell me what programm in what version do you use and please attache it here.
    Did you use the library for creating *.tdms files like in the link ?
    http://zone.ni.com/devzone/cda/tut/p/id/6471
    Here you find the gtdms_8.x.zip - when you extract it and opened the *.llb you find vi´s for all functions e.g. writing 2d array of strings to *.tdms file
    when you open the subvi´s then you see how created and writing datas/structure to *.tdms files. Because *.tdms is binary you can´t see structure with open it in editor.
    When you don´t have Labview you can use the 30 days test of current version 8.5 under following link
    german version download link
    https://lumen.ni.com/nicif/d/lveval/content.xhtml
    english version download link
    https://lumen.ni.com/nicif/us/lveval/content.xhtml
    Hope it helps
    Best Regards

Maybe you are looking for

  • Filtering report data based on user login and Parameter fields

    Post Author: mronquillo CA Forum: General Hi,I am running a report that filters data based on the user login. To do this, I created a formula called @user that compares the login name (using the CurrentCEUserName field) and returns the user's name. I

  • A/P invoices without Purchase Order

    Hi, I am trying to avoid accounting dptm to enter A/P invoices that do not com from a copied PO without an authorisation, but can't find out how to do it. I have tried through the auth process, but I can't write a propper query. It would also be grea

  • Project 2013 with Shared Resources(resource pool) stored in O365 SharePoint

    I am trying to use both a resource pool and storing all projects files in Office 365 document library. I have 3 project files, one with resources only and 2 for project scheduling. If I store the files on the local machine, when I open both resource

  • BAPI in MM

    Hi MM Gurus Could any one share the BAPI's  in MM specific to Business Processes which was required by the client and it had been fulfilled and implemented successfully. Appreciate if you can elaborate on what was the requirement and steps to accompl

  • Pairing problem with Docs to Go and Windows 7

    First, I'm not sure this is the correct forum. I've setup a new Windows 7 laptop and installed Docuemnts to Go (latest version downloaded, no updates needed). An was able to pair with both my iPhone and my iPad. iTunes syncs fine (but that's using a