Telechargement impossible probleme de communication avec le serveur de licence E_STREAM_ERROR  : ce message pour ordinateur Window 7 en téléchargeant un e-book.

Que faire ? merci

Do I need the Recocery CD ?
Do I need to save all my files on a External HardDrive ?
How will be the process ?
Yours
YH

Similar Messages

  • Erreur lors de l'obtention de la licence. Problème de communication avec le serveur de licences : E_ACT_NOT_READY ?

    Erreur lors de l'obtention de la licence. Problème de communication avec le serveur de licences :
    E_ACT_NOT_READY

    Bonjour,
    comment avez vous réglé le pblm ?

  • Telechargement impossible

    Impossible de telecharger un ebook j'ai le message suivant:Telechargement impossible. Erreur lors de l'obtention de la licence. Problème de communication avec le serveur de licences: E_LIC_LICENSE_SIGN_ERROR.

    Avez-vous correctement enregistré votre copie de ADE ( Digital Editions ) avec votre ID Adobe ?
    Meny / Library / Autoriser l'ordinateur ( Bibliothèque / Autoriser l'ordinateur à plus v1.7.2 plus fiable )
    Si oui , peut-être l'autorisation est en quelque sorte corrompu . Voir ci-dessous .
    ~ ~ ~ ~ ~
    Parfois ADE obtient son enregistrement / activation confus et dans un état semi - autorisé .
    La désinstallation et la réinstallation n'aide pas .
    Malheureusement , il donne souvent alors des messages trompeurs d'erreur sur ce qui est mal .
    Un message incorrect commune vous informe que l'ID est déjà utilisé sur un autre ordinateur et ne peut pas être réutilisé .
    Cela peut souvent être résolu en enlevant complètement toute autorisation à l'aide Ctrl-Shift- D à l'écran Bibliothèque ADE ( cmd -shift- D si sur Mac ) .
    Redémarrez ADE , puis autoriser à nouveau avec votre ( ancien) Adobe ID .
    Dans les cas extrêmes sur le mac , l'étape supplémentaire suivante a aidé certaines personnes . Accédez à / Users / / Library / Application Support / Adobe / Digital Editions et faites glisser le fichier activation.dat à la poubelle. Si vous utilisez 10.7, voir les fichiers de bibliothèque d'accès de l'utilisateur caché | Mac OS 10.7 Lion . http://forums.adobe.com/thread/1265248?tstart=0
    Have you correctly registered your copy of ADE (Digital Editions) with your Adobe ID?
    meny/Library/Authorize Computer (Library/Authorize Computer in older more reliable v1.7.2)
    If so, maybe the authorization is somehow corrupt.  See below.
    ~~~~~
    Sometimes ADE gets its registration/activation confused and in a semi-authorized state.
    Uninstalling and reinstalling does not help.
    Unfortunately, it often then gives misleading error messages about what is wrong.
    A common incorrect message informs you that the ID is already in use on another computer and cannot be reused.
    This can often be resolved by completely removing any authorization using ctrl-shift-D to the Library screen on ADE (cmd-shift-D if on Mac).
    Restart ADE, and then reauthorize with your (old) Adobe ID.
    In extreme cases on the mac, the following extra step has helped some people.  Navigate to /Users//Library/Application Support/Adobe/Digital Editions and drag the activation.dat file to the trash. If you are using 10.7, see Access hidden user library files | Mac OS 10.7 Lion. http://forums.adobe.com/thread/1265248?tstart=0

  • HT204053 Connexion impossible en raison d'un problème de communication avec iCloud.

    Connexion impossible en raison d’un problème de communication avec iCloud.
    yep
    i got this message before install osx update form lion lion 10.7.4
    on idée ?

    Bonjour,
    Je pense que tu as un problème de configuration de la communication.
    Déjà, tu as les drivers, tu as essayé le panneau de test de MAX donc c'est pas mal.
    Je te conseil de regarder la doc de ton instruments, si je me suis pas trompé, c'est celle-ci : http://cp.literature.agilent.com/litweb/pdf/34401-90419.pdf
    page 91, il est expliqué comment configuré la communication RS-232. Il faut que tu vérifie que tu as bien la même configuration sur l'instruments et pour le port COM dans MAX.
    Essaye de faire correspondre les configurations et essaye avec le panneau de test de MAX. SI tu n'y arrive depuis la, ce n'est pas la peine d'essayer avec les vi du drivers.
    Si ca ne fonctionne toujours aps, regarde également la configuration du port com dans le gestionnaire de périphériques, des fois, il faut la changer à la main dedans éaglement pour que ca fonctionne.
    Cordialement.
    .mesLeft{float:left} .mesInfo{border-left:solid 1px #989898;font-size:x-small;color:#989898} .mesLogo{float:right;opacity:0.18} .mesLogo:hover{opacity:0.9}
    Maxime R.  
      CLD - Certified LabVIEW Developer / Développeur LabVIEW Certifié  
      CLAD - Certified LabVIEW Associate Developer   

  • ITunes me dit qu'une nouvelle version pour mon iPhone est disponible. (5.1. au lieu de 5.0.1) mais quand j'exécute cela , j'ai le message "prise de contact avec le serveur des mises a jour du logiciel de l'iPhone en cours" et puis plus rien ne se passe

    Bonjour,
    Quand je veux installer une nouvelle version (5.1) sur mon iPone, apparait le message "Prise de contact avec le serveur des mises á jour du logiciel de l'iPhone en cours" le message tourne mais rien ne se passe.
    Quelqu'un peut-il m'aider ? Merci beaucoup.
    Eric

    Hi Subarutuning,
    If you are receiving an error when attempting to update your iPhone, use the steps in this article to troubleshoot -
    Resolve iOS update and restore errors - Apple Support
    Error (1) is associated with a hardware issue, but use these steps -
    These errors mean that your device or computer may have a hardware issue that's preventing the update or restore from completing.
    Check that your security software and settings aren't preventing your device from communicating with the Apple update server.
    Then try to restore your iOS device two more times while connected with a cable, computer, and network you know are good.
    Confirm that your security software and settings are allowing communication between your device and update servers.
    If you still see the error message when you update or restore, contact Apple support.
    Thanks for using Apple Support Communities.
    Best,
    Brett L 

  • Probleme de communication cRIO -63043

    Bonjour à tous,
    jusqu'à présent tous allait bien sur la communication avec le cRIO, mais d'un coup ça ne marche plus... Je lance le programme FPGA qui tourne bien tous seul mais des que je lance le programme RT la communication se coupe et ce message apparait :
    Quelqu'un aurait une idée de comment régler ce probleme ?
    Cordialement
    Nathan
    Résolu !
    Accéder à la solution.

    Bonjour,
    Une première piste à tenter afin de résoudre votre problématique est de suivre la procédure suivante :
    http://digital.ni.com/public.nsf/allkb/B746EA10EA65BE894825733D006BEA8F?OpenDocument
    Cordialement
    Guillaume D

  • Design problem: RS232 communication

    Hi,
    I have a design problem for communication with a device via RS232. Since I'm normally a C++ programmer I might just look at the problem from a wrong angle and hope for some hints how to do it in LabVIEW.
    The scenario:
    A device is communicating with the PC via RS232. The device permanently sends data packets. At the same time, commands can be sent to the device and it returns replies. Data packets and reply packets are arbitrarily mixed, i.e. after sending a command there could be a couple of date packets before the reply comes back but the packets can be distinguished by an identifier.
    At least one, ideally several VIs should communicate with the device. Commands should be sent by pressing buttons and the incoming data should be parsed (the packets contain mutliple data streams) and shown on graphs or saved to files.
    My initial idea:
    Coming from C++ I wanted to build a class for the communication that permanently reads the incoming data and splits it to reply and data packets. This class would then have a function to send out a command and would return the reply or a timeout and it would be possible to register and unregister listeners (I wanted to use queues for this) for the various data streams.
    The problems I ran into:
    There were a couple but the two most pressing problems were: how could I communicate with the constantly running sample VI (e.g. to stop sampling) and how could I propagate changes to the class to it (e.g. new listeners). Since it is not returning I don't see a good way to implement it as in instance funcion (i.e. pass it the object). I could probably not let the sample function run continously but call it periodically from outside. However I planned to implement the class as a singleton, so it could be used parallely from different VIs.
    Is there a best practice for a case like this?
    I'm glad about any hints or ideas.
    Thanks,
    Tobias

    tfritz wrote:
    Hi,
    thanks. Since almost the same thing was suggested to me in a German forum I guess this is really common practice (using one VI with different methods controlled by a queue). It still seems a little "unnatural" for me but my biggest concern (bad interface description) was shattered by the suggestion in the link you sent me to wrap these functions with wrapper VIs, thus caller VIs won't have to deal with the call-by-queue-mechanism. This might also be easier to port to a different implementation later. However I still see the danger that the continously running VI could easily become bloated. 
    It also requires me to change the way I have looked at VIs until now. In our course they told us that VIs are basically functions. Using this design patterns, the VI becomes more of a module, really (Like a C module implemented in a C-Source file). But I will try it. It sounds as if it could work.
    I will still look into the OOP solutions a little more, though. Do I understand you correctly that you wouldn't recommend using LVOOP because it's still buggy? What about dqGOOP for example? This sounds like it could do what I need (however it doesn't seem to implement things like polymorphism, late binding and inheritance so I don't quite see what's so OOP about it. It seems more like programming with structures in C.)
    I don't know if LVOOP is buggy or not.  I think early on it was buggy and things have improved in recent versions. I have read that it doesn't have all the features that you would have in OOP like C.  I wouldn't recommend it only because I'm not familiar with it at all.  I can't recommend something that I'm not comfortable with.  If you go that route, plan on spending time in these forums and in LAVA to reading up on what others have done.  I haven't hard of dqGOOP.
    But back to your suggestion. I still have a couple of questions:
    - How do you return values from the module? Would you use a queue for that as well?
    - Where would the parameter queue be held (created and passed to the VI)
     I would store all of these in a functional global variable.  This is the VI that stores data in shift registers.  Ben's action engine nugget is an advancement on that.  This allows for both the calling VI and the parallel running subVI to get and set the data as needed.  It runs quickly so neither process should be forced to wait while the other  VI is doing its thing.
    - My VI has to be constantly sampling and this shouldn't be interrupted too long by other functions as adding a listener. However both functionalities have to access the same kind of data. Is there an easy way to parallelize this? Would the sampling be a case in the case diagram that's always used if no command was sent to the VI or would it somehow run parallely?   Yes.  There are a couple of ways of doing this.  One would be for the dequeue to have a timeout function.  In the event the dequeue times out, you run the code that is doing the acquisition.  I think a better method is that the code that does the acquisition enqueues its own command again to the end of the queue.  Let's say that is command A.  So when case A finishes, it enqueues A, which seeds itself to run again.  So if nothing else comes into the queue, it just executes A , A, A, A.  But let's say another section of code needs to do something such as command B.  It will slip B into the queue while A is executing.  So you would A, B, then A again, because A would get slipped back into the queue when the first A finishes, but B has already been put in while the first A was running.
    - Would it be possible to make the VI reentrant and in this way use it simultaneously on different COM ports (using different parameter queues as well)? I'm not sure if I will need this but it would be neat if it could work.
    I think you could do this.  It may be a case where the VI is saved as a template  (.vit) and you initiate it multiple times.  I haven't needed to do this before, so I'm afraid I can't provide any details or useful tips. 
    Well, I will fool around some more. Thanks so much for your help. This is kind of exciting since the concepts are quite new for me. Btw, is there something like an academic theory (computer science) for LabVIEW? I came across functional languages in university but data flow languages are still a new concept for me.
    Tobias
    tfritz wrote:
    Another question about the "dynamically starting" of the VI:
    How is the path handled? Is it guaranteed that it always takes the VI from the project or does it just search for the first VI by that name it finds in the file structure? Does this still work when building an .exe from the project? What happens if the VI is already running? Can you test for this?
    While I'm at it: is there a way to stop LabVIEW from searching for subVIs it can't find when openin a VI? This resulted in very unexpected behaviour sometimes where it would find the VI somewhere else (with the same name but maybe an older version).
    In my case, I just had the path hardcoded.  It is my only instance, I'm not planning on moving the VI's.  If you don't have the path, it will take a VI by that name if it's in memory.  If it isn't in memory, it starts searching relative to the calling VI's path.  One thing I know, if you are dealing with relative paths, a subVI has a different relative path in an .exe as opposed to the development environment.  The name of the .exe becomes a folder.  So in development, if your sub VI is mySubVI.vi.  In an executable, its path is MyExe.exe\MySubVI.vi
    For all of this, I recommend searching the forums to get more details.
    If it is searching for a VI, you can hit ignore.  But of course you'd have to do it before it finds it.  When you are dealing with versioning issues, I recommend making a backup copy of the entire directory structure elsewhere.  Some location where it shouldn't stumble across it.

  • Problem of communication with compactrio

    Hello,
    I am working with a compactrio 9014 and labview 8.5
    I have a problem of communication with my compactrio. I acquire sound with NI 9215 and transmit points from the fpga VI to the VI on the real time target at a rate of 10Khz. On the VI on the RT I have two loops, one determinisic running at a speed of 10Khz (0.1ms) (in this loop I will do my signal processing) and one non-deterministic running much slower (20ms) to communicate data to my computer. To communicate data to my PC, I used shared variable.
    The problem is that if I run the VI_RT, I loose immidiately the connection. I think that is because the VI is taking up all of the execution time of the
    processor and is starving out the communication loop that is used to
    send data back to my PC.
    Because of this problem, I try to configure my compactrio to automatically run on startup of my cRIO. So I follow the steps I have read in another message in the forum posted by MattP
    To make your application (RT host VI and FPGA VI) run automatically on startup of your cRIO, you will need to do the following:
    1.  Download the FPGA VI to the flash memory on your cRIO.  If
    using LabVIEW 8, right-click on the VI in the Project Explorer Window
    and select Download VI or Attributes to Flash Memory...
    2.  Build an executable out of the RT VI.  Under your RT target 
    in the Project Explorer, right-click on Build Specifications and select
    New>>Real-Time Application.  Select the source files necessary
    for your application and any support files to be included.  Click Build.
    3.. After building the RT Application, you will find its entry
    under the Build Specifications folder in your project.  Right-click on
    the application and choose Set as startup.  Right-click again and
    choose Deploy, which will download the application to your cRIO.
    With  this procedure, I thougt that I can  run my  loop faster  because I  don't have the RT VI open on my desktop  (PC), so the PC don't have to synchronise the VI. But when I startup my compactrio, I loose connection with the target...
    So, what is wrong with my project?  Is it possible to run a loop at 10kHz on the real time processor and communicate in the same time (but every 20ms) data to my PC. Can someone explain me the right procedure to do that at this frequencies?
    I have attached my project and hope that someone can help me.
    Attachments:
    Communication.zip ‏658 KB

    Hello,
    The method you use in your application to transfer the data from the FPGA to
    the RT Host use the Front Panel Interactive Communication that write/read the
    control/indicators of the FPGA VI. This method provides also risk of Race
    Condition and use uP resources.
    To avoid errors in data caused by race conditions and use less processor resources, 
    I suggest you to rewrite this part of your application with the method 
    DMA transfer from FPGA to Host.
    You will find some good tutorial at the following address.
    What
    is the Best Method For Synchronizing a LabVIEW FPGA and a Host Interface VI?
    Best Regards,
    Nick_CH

  • Problem in Communication channel monitoring..

    Dear friends,
    I am facing a problem in Communication channel monitoring.
    Problem:
    I have designed several communication channels in the Integration directory.
    To check the status of channel i will go to RWB->Component Monitoring->Adapter Engine->Communication channel monitoring, then we have a selection screen to filter out the channel, adapter,etc..
    Here i am NOT seen any channels to filter out. I.e. Channels in the Integration directory are not reflecting here.
    Can you please help out on this?

    HI,
    Do the CPACache refresh .
    ALso check this SAP Note- 937382
    Regards,
    Moorthy

  • Communication avec un objet externe type Iphone avec le bluetooth

    Bonjour;
    Actuellement au Lycéen, dans le cadre des PPE, je me pose quelques questions sur le produit Labview.
    Toutes mes questions porteront sur ce module : USB-6002 16bits 50 ks/s Multifuntion I/O and NI-DAQmx, ayant pour référence: 782606-01.
    Partie communication module vers un appareil intelligent.
    Est-il possible de faire communiquer le module en bluetooth avec un smartphone(iPhone) ?
    Comment cela se passe au niveau de la programation pour le faire communiquer en bluetooth ?
    Est-ce qu'il y a une application sur Apple Store ou autre, déjà préprogrammer pour programmer la communication avec le module Labview plus rapidement? ou faut-il utiliser XCODE(logiciel de programmation Apple) ?
    Peut-on faire apparaitre des jauges et autres à l'écran de l'iPhone ?
    Peut-on sortir un .exe, d'après une interface faite sur le logiciel Labview ?
    Est-ce que ce logiciel(.exe) peut communiquer avec le bluetooth de l'ordinateur et le bluetooth de l'iPhone ? Afin d'afficher des jauges etc…
    Partie communication appareil externe vers module.
    Est-il possible de renvoyer les informations d'une ceinture cardiaque ou autre vers le module puis de les renvoyer en bluetooth vers un PC ou smartphone ?
    Cordialement
    Sébastien

    Bonjour,
    pour le module, vous trouverez vous réponse sur ce lien: http://www.ni.com/pdf/manuals/374259a.pdf
    Labview permet de communiquer en bluetooth.
    la création de l'exécutable nécessite l'option builder donc si vous n'avez pas cette option, vous ne pourrez pas faire d'exécutable.
    concernant les questions pour des smartphone, il faut regarder le logiciel data dashboard fait spécialement pour ces produits. vous pourrez faire les graph que vous voulez.
    Cordialement
    L.MICOU

  • Communication avec capteur MicaZ

    Bonjour,
    J'ai flashé un capteur MicaZ avec un serveur web embarqué  smews 
    maintenant je n'arrive pas à tester l'application web embarqué.
    le capteur ne répond pas.
    j'ai utilisé ces deux commandes pour configurer l'interface serie
    $slattach -s 115200 -p slip /dev/ttyUSB0 -L &
    $ifconfig sl0 192.168.1.5 pointopoint 192.168.1.8 mtu 1500 
    j'ai testé sous xp en créant une nouvelle connexion mais c'est le même problème.
    avez vous une idée pour résoudre ce problème?  

    Duplicate Post

  • Problem with communicating with server https.

    I am in Los Cabos and experiencing problem to add account on my iPad. I use my existing apple ID and password but I receive this message: Verification Error. There is a problem in communicating with the server HTTPS. Can some help me please?

    Did you find anything on this? I'm facing the same issue... Thank you

  • I have problems in communication between my notebook and Epson printer. It goes offline everytime I unplug it from the notebook and there is no way how to switch it on. Although the printer is recognized and scanning is not a problem. Any solution?

    I have problems in communication between my notebook and Epson printer. It goes offline everytime I unplug it from the notebook and there is no way how to switch it on. Although the printer is recognized and scanning is not a problem. Any solution?

    this is exactly the kind of response i expected, almost begged support to please not do this to me and yet there it is another meaningless, non helpful, standard template response to restart my apple tv.
    this does NOT work which is why i am contacting you. i have tried all suggestions about unplugging and restarting and nothing works.
    i live in an apartment and logon to the provided wifi wireless. so i do not have access to a router. however, management says they have talked with their provider and have been assured that the required ports are available.
    remember all the jokes about how bad windows was because the solution was always to re boot. funny huh? how is apple any different.
    i have been to the local apple care store and they are clueless, too.
    should we just end it here and you admit that i will not be getting any support from apple on this one? i got the ipad because my kids were such big fans. it is difficult for me to share their enthusiasm.
    at this point i am just curious about how you say you cannot support your own product so i can complete my file on this contact.
    thanks...sorry it was you who got this problem..

  • Probleme de droits avec les prefs d'INDESIGN

    Impossible de lancer l'appli, elle me demande d'obtenir les droits pour le dossier préference.
    Je suis sur Maverick et je ne trouve pas où ouvrir les droits à ce dossier.
    Merci pour votre aide
    Cyril

    http://support.apple.com/kb/PH13799
    http://helpx.adobe.com/indesign/kb/indesign-preferences-support-file-locations.html

  • Has Apple acknowledged the problem yet with itunes aborting preview of songs after about 10 seconds on windows 7 and if so is there an answer other than ipconfig?

    Has Apple acknowledged the problem yet with itunes aborting preview of songs after about 10 seconds on windows 7 and if so is there an answer other than ipconfig?  IPConfig /flushdns doesn't help at all.  Until they fix it I will be previewing and buying my songs thru Amazon.

    Doublechecking ... do you still get that if you update to iTunes 10.6.3.25 (just released today)?
    http://www.apple.com/itunes/download/

Maybe you are looking for

  • Registered Server Program not being registered?

    Hi, first of all, I'm an ABAPer, not a Basis guy, so i apologize if i'm not giving all the info required to solve this issue. We have a program that's scheduled to run every morning at 4am. This program calls an RFC to XI and sends data to an externa

  • Abandoned calls in IVR Campaign

    IVR Outbound Camnapign. Settings: "Cisco Config Manager" --> "Outbound Option Campaign" --> "Abandoned call waiting time" =10 sec. To the person the call arrives (from IVR Campaign), the person hears the first IVR prompt, further in 5 seconds the abo

  • Can't access 'print settings' in Photoshop...

    Hi: In Photoshop, I am not able to see 'print settings' when I go through the print menu.  Does anyone know how I can access them, or a way I can specify the paper type (plain, ultra premium, etc.)?   When I look for the print settings in the other s

  • How to put MBA in 'Safe Sleep' mode.

    How do you put MBA in Deep Sleep 'Safe Sleep' mode? I have been reading many postings here and on the internet and am not getting a definitive answer. The whole topic seems to be rather confusing. Does someone have a simple answer in achieving hibern

  • Camera RAW and iPhoto integration

    >I want to edit a JPG or TIF image in iPhoto in ACR, but I seem to be unable to do that. >The panel with the pop-up menu to set Camera RAW when opening a JPG or TIF file from an ordinary Finder Folder I appears to be completely bypassed, when when co