Terminal Configurat​ion Q: Differenta​l or Single-End​ed for reading IC pin I/O's
I'm trying to simultaneously monitor the I/O's on each of the pins of a 14-pin differential amplifier IC chip. This chip is part of an operating circuit so I've got a chip-clip with breakout wires going to a cDAQ 9172 and NI-9205 module.
My question is about terminal configuration with this particular module and an embedded IC chip contained within an "live" operating circuit.
Right now I have pins 1-14 of the chip-clip breakout wires plugged into the module from ACH0-ACH7, then from ACH16-ACH21 (basically straight down the LH side of the module's terminals). I have a standalone ground wire going from the PCB's negative rail to COM on the 9205. Using Signal Express I have the terminal configuration set to RSE.
Is this the proper terminal configuration for this application?
What I'm trying to do is record the amplitudes of the IC chip's I/O's while the circuit is operating. I will swap out different IC chips and compare the outputs of each one.
SCXI- 1000 Chassis w/ 1346 adapter
PCI 6281 DAQ card
SCXI- 1520 Bridge Board w/ 1314 Terminal Block (x2)
SCXI- 1180 Feedthrough Panel w/ 1302 Block
Signal Express 2014.
Win7 Enterprise
Jason,
I've read both documents in full which is where I got the information for terminal configuration. My concern is whether the readings are accurate based on the terminal configuration I've selected. I'm getting "data" when I log the voltages from the chip but it's hard to tell if the data is truly accurate to each pin or if there is crosstalk or ghosting going on.
Again, this is a 14-pin op amp I'm trying to measure voltages from. The chip is on a battery powered circuit so I have each leg of the pin tied to a single Analog IN channel on the 9205 and the ground lead from the chip tied to COM, measuring RSE.
Below is a quick schematic of the terminal config.
I think it's right but again if I'm looking at inaccurate voltages I wouldn't know either...
SCXI- 1000 Chassis w/ 1346 adapter
PCI 6281 DAQ card
SCXI- 1520 Bridge Board w/ 1314 Terminal Block (x2)
SCXI- 1180 Feedthrough Panel w/ 1302 Block
Signal Express 2014.
Win7 Enterprise
Attachments:
Capture.JPG 122 KB
Similar Messages
-
Differenti​al using single ended mode
Hi I am using the multifunction DAS Card which is set to single end mode as I need to use it to acquire all input signals, using single end channels. Now I have got the corrected measured inputs in RMS voltage and I would like to get the differential value from the acquired inputs, using Labview functions. So How do I go about it?
Cheers,
ClementIf all you need is the difference between one channel and another, the subtract function usually works. If it's more complicated, could explain with more details?
-
Single app subscription for Photoshop CS6 vs Photoshop CC
What is the difference between a single app subscription for Photoshp CS6 and Photoshop CC?
Hi Jeff2014,
The difference lies in between the version.
Initially the Creative Cloud was released with the then running current version which was CS6, Creative Cloud comes with a feature of self upgrade at no extra cost.
Photoshop CC is the upgraded version of Photosho CS6, in future the upgrades will be done autmatically.
This will help a user to have the upgraded automatically as long as the user has an active subscription.
Regards,
Rajshree -
How to display time difference in a single cell separately.
Hi All,
I have an issue where you have to calculate the Start time and End Time , Start Date and End Date for a particular Work item number
For eg ;
WI_ID WI_CD WI_CT
000001312610 02/09/2009 09:48:4 02/09/2009 09:48:9
000001312610 02/09/2009 09:54:4 02/09/2009 09:54:9
000001312610 02/09/2009 09:54:5 02/09/2009 09:54:9
000001312610 02/09/2009 10:07:0 02/09/2009 10:07:9
000001312610 02/09/2009 10:07:0 02/09/2009 10:07:9
000001312610 02/09/2009 10:16:5 02/09/2009 10:16:9
000001312610 02/09/2009 10:16:7 02/09/2009 10:16:9
Similarly I get the Endtime and ENd dayfrom other table for same work item.so my output should have the result as ,So my requirement here is
in the it should show the display in a single cell .as, 5secs, 5 secs,4 secs,9secs,4 secs,2 secs
for each work item.
Can any body help me on this issue.
Any pionters for this are much helpful forme.
Thanks
RohiniHi Kewin,
Its not the question of concatenation, that can be handled later.
But my issue is how to calculate time difference for each single step -
Difference between select single * & select upto 1 rows
difference between select single * & select upto 1 rows
Hi,
According to SAP Performance course the SELECT UP TO 1 ROWS is faster than SELECT SINGLE because you are not using all the primary key fields.
Select single is a construct designed to read database records with primary key. In the absence of the primary key, it might end up doing a sequential search, whereas the select up to 1 rows may assume that there is no primary key supplied and will try to find most suitable index.
The best way to find out is through sql trace or runtime analysis.
Use "select up to 1 rows" only if you are sure that all the records returned will have the same value for the field(s) you are interested in. If not, you will be reading only the first record which matches the criteria, but may be the second or the third record has the value you are looking for.
The System test result showed that the variant Single * takes less time than Up to 1 rows as there is an additional level for COUNT STOP KEY for SELECT ENDSELECT UP TO 1 ROWS.
The 'SELECT SINGLE' statement selects the first row in the database that it finds that fulfils the 'WHERE' clause If this results in multiple records then only the first one will be returned and therefore may not be unique.
Mainly: to read data from
The 'SELECT .... UP TO 1 ROWS' statement is subtly different. The database selects all of the relevant records that are defined by the WHERE clause, applies any aggregate, ordering or grouping functions to them and then returns the first record of the result set.
Mainly: to check if entries exist.
Select Single
You need to mention all the key fields of the table.
No END SELECT required.
More performance compared to upto 1 row.
Where as UP to 1 row.
YOu can use if you do not have all the primiary key fields available.
END SELECT requeired.
Since all keys are not passing, possiblities of have other rows which satisfies the condition.
Select Statement with EndSelect is a loop, which in a single run retrieves a single Record. This Record has to be stored in a Work Area and then appended into an Internal Table.
Select Statements without EndSelect is not a loop and it retrieves the whole Record set matching the Criteria in a single shot and has to be Stored in an Internal Table Directly.
The most important thing to remember about the SELECT SINGLE is
There are several things to remember:
1) It retrieves only one row
2) It does not need an ENDSELECT statement
3) THE FULL KEY OF THE TABLE MUST BE INCLUDED IN
THE WHERE CLAUSE OF THE SELECT STATEMENT
Regards -
Difference between select single & select upto 1 row
Hi,
what is the Difference between select single & select upto 1 row?
Whose performance is better?
Regards,
MayankHi
According to SAP Performance course the SELECT UP TO 1 ROWS is faster than SELECT SINGLE because you are not using all the primary key fields.
The 'SELECT SINGLE' statement selects the first row in the database that it finds that fulfils the 'WHERE' clause If this results in multiple records then only the first one will be returned and therefore may not be unique.
Mainly: to read data from
The 'SELECT .... UP TO 1 ROWS' statement is subtly different. The database selects all of the relevant records that are defined by the WHERE clause, applies any aggregate, ordering or grouping functions to them and then returns the first record of the result set. -
Difference bt select single & select up 1 record
What is the exact difference between select single and select up to 1 record
Hi
Difference Between Select Single and Select UpTo One Rows
According to SAP Performance course the SELECT UP TO 1 ROWS is faster than SELECT SINGLE because you are not using all the primary key fields.
select single is a construct designed to read database records with primary key. In the absence of the primary key, it might end up doing a sequential search, whereas the select up to 1 rows may assume that there is no primary key supplied and will try to find most suitable index.
The best way to find out is through sql trace or runtime analysis.
Use "select up to 1 rows" only if you are sure that all the records returned will have the same value for the field(s) you are interested in. If not, you will be reading only the first record which matches the criteria, but may be the second or the third record has the value you are looking for.
The System test result showed that the variant Single * takes less time than Up to 1 rows as there is an additional level for COUNT STOP KEY for SELECT ENDSELECT UP TO 1 ROWS.
The 'SELECT SINGLE' statement selects the first row in the database that it finds that fulfils the 'WHERE' clause If this results in multiple records then only the first one will be returned and therefore may not be unique.
Mainly: to read data from
The 'SELECT .... UP TO 1 ROWS' statement is subtly different. The database selects all of the relevant records that are defined by the WHERE clause, applies any aggregate, ordering or grouping functions to them and then returns the first record of the result set.
Mainly: to check if entries exist.
<b>Reward points for useful Answers</b>
Regards
Anji -
Difference between Release call, End and Termination node in ICM
Hi all,
Can anyone let me know the clear difference between Release call, End and Termination node in ICM and in which situations we should use these nodes.
Thanks.
Regards
DeepakCheck this, hope will be helpful.
http://www.cisco.com/en/US/docs/voice_ip_comm/cust_contact/contact_center/ipcc_enterprise/ipccenterprise7_0/user/guide/ipce70sg.pdf
Sent from Cisco Technical Support iPhone App -
Single Transaction code for ALE Configuration
Hi All,
I want to Know is there any Single Transaction code for the ALE Configuration instead of going through SALE, WEDI t-code or with defining logical systems assigning them to clients, creating RFC and Distribution Model, generate partner function and..so on.
Please let me know if there is any t-code through which i can do the ALE configuration in a single T-code.
Thanking you in advance,
Bhanuhi ars
i got a task saying that message type is DESADV01 ,but u told that DESADV01
is basic type,can i know the difference.
regards
sagar -
How to connect single ended connection​s?
I am new in this field. I am trying to accquire single ended data on
single channel using the following configuration(see fig A and fig B in the
attached figure) . It works all right when i take input from signal
generator. please notice specially the power/signal connections. I have
chosen NRSE settings.
For my application I have to to test the same settings when the input
signal is taken from 4* 1.5 V pencil cells ( see figure B). In this setting
however it does not work at all. I have again chosen NRSE settings. What is
the problem? What is NRSE and RSE? What is the difference?What should I
choose in this case?
Can anybody help?
[Attachment diagram.doc, see below]
[See first answer for additio
nal information][Attachment(s) for question]
Attachments:
diagram.doc 73 KB -
Dear all,
i wrote a program in VC++ which acquires some analog voltage channels using NIDAQmx. By means of the "DAQmxCreateAIVoltageChan()" function it works properly, but I've faced a question:
When I measure a sine wave as a input channel whith diffrential terminals (pins) on NI-Device, there is no problem but if I connect the input signal in single ended form (connect input signal to each single terminal and connect GND of NI-Device and Signal generator together), there is a irrigular and alternative offset (DC value) in aqcuiered data that shows there is an error in connection of GND's. (I'm sure about function generators)
Is there any specific function to assign exactly that input data should be measured in differential or single ended form? I mean, should I write seperate codes in C++, if I want to measure input signal in both forms of differential and single ended or does the mentioned function satisfy both needs (when the answer is positive wherefrom does this fault emerge)?
Thanks a lot for your helpfully replies in advance,
sincerely yours,
Mohammad HaratiHi Harati,
I'm not sure what your question is, but I have some questions too:
1) Which device are you using?
2) Did you connect the AI GND pin (in single ended)?
3) As you called DAQmxCreateAIVoltageChan(), what parameter did you set for terminalConfig in eiter cases?
Here is the documentation for DAQmxCreateAIVoltageChan()
http://zone.ni.com/reference/en-XX/help/370471W-01/daqmxcfunc/daqmxcreateaivoltagechan/
This whitepaper may also help you:
http://www.ni.com/white-paper/7113/en/
Kind regards
Heinz -
Single Window Mode for Windows version?
Hey there,
as some might know, there's a "hack" to get Single Window Mode for Safari on Mac. Normally. links with "target=_blank" will open in a new window instead of a new tab. In order to get Single Window Mode, the following code needs to be typed into Terminal:
defaults write com.apple.Safari TargetedClicksCreateTabs -bool true
Unfortunately, this won't work on Windows, so I would like to know if there's another way to have Single Window Mode.No, there isn't. That feature is not implemented in the Windows version The only way to open targeted links in a new Tab is to Control-click or Right-click on the link and select Open in New Tab from the contextual menu.
Mulder -
Can't get graphs to show single-ended input
Using mx Base, I've created an Analog continuous input task. I've configured the task on the configuration utility as single ended, but on my VI graph, the data shows up as what it would be if it were differential. Is there some kind of disconnect between the configuration utility and my task on my VI? when i use the NI datalogger that's included with the mx Base driver and I choose RSE as the terminal configuration, i get the correct readings (same readings as i see in the oscilloscope).
Please help!Hello Greenepece. Thank you for contacting National Instruments. Your best bet is to use the dynamic examples that come with DAQmx Base. These examples can be found at C:\Program Files\National Instruments\LabVIEW 7.1\examples\daqmxbase\Dynamic\ai. In these examples there is a VI called DAQmx Base Create Channel.vi that has an input called input terminal configuration. Create a constant for this and select RSE. This should give you the same results as the Data Logger. Please let me know if you have any questions. Have a great day!
Marni S.
National Instruments -
Can i use a single ended encoder with a 7344 controller?
Can i use a single ended encoder with a 7344 controller?
The encoder inputs of the 7344 are ground referenced. So the answer is yes, you can use a single ended encoder with a 7344 controller. Signal connection should be straight forward.
If you are using a UMI-7764 for signal connections please refer to the "Encoder Terminal Block" section (page 15) of the UMI User Guide. There are drawings for the signal connections for single ended and differential encoders.
For the case that you don't have the user guide of the UMI-7764 please download it from this link:
http://digital.ni.com/manuals.nsf/websearch/AC6FAA69218C9624862567BD0061DDAC?OpenDocument&node=132100_US
Best regards,
Jochen Klier
Applications Engineering Group Leader
National Instruments Germany GmbH -
Keyword re-directs in a single endeca instance for different application
Hi all,
We are maintaining a single endeca application for 2 different web-sites.Now,we have a requirement to set up keyword -re-directs for both the applications but the re-directs set up in 1 application should not clash with the other.Actually,I tried setting up in 2 differnt groups using dev studio,but I am not seeing any difference in JSP ref application.Ex: I set up a re-direct for word "Shampoo" in both sites but at any time,only 1 re-direct is seen.
Please advise.
Regards
ShreyasHi Shreyas,
Keyword redirects are global to an index.
You can try following work arounds,
Option 1 :- I guess you are using experience manager, in that case, you can create a custom cartridge for the keyword redirects and play around with triggers to makes it application aware. This option is good if you have number of keyword redirects are lesser.
Option 2 :- With the existing keyword redirects you can do something like below, which is a dirty workaround. see if you can include site name in the user search term . For example say you have site1 and site2 as two sites. So if you are to add a term as google for site1 and not not for site2, then you will add it as "site1 google" with match all or match phrase. from the front end you will have to query twice first time with "google" as search term and second time with "site1 google" as a search term. you should get just keyword redirects from the second query. Additional search query here may not be good for the production environments. Thisld option should not be used if you have large volume of data or large volumes of the traffic.
Hope that makes sense!
Maybe you are looking for
-
Mini DVI to Video converter, red tinge
I recently bought a macbook, and so far I'm very satisfied with it (aside from the heat problems, which aren't that bad imo.) A few days ago, I recieved a Mini-DVI to Video converter in the mail to use with my six-year old television. Previously, I h
-
Access a java card via two logical channels
Dear all; I was wondering if someone managed to do following setup(because it doesn't work for me): I have an android phone with a sd-card slot in which I've inserted a java card. I can open a logical channel from my android phone to the java card. S
-
Using a source file to test behaviors
I am developing some special mail handling features, based on the message content and some library information that I have. I don't want to go to the trouble of setting up a POP3 server since I have the test data in flat files. Has anyone developed a
-
SWAP space usage??
When I am monitoring my system using TOP, all of my java process is running well over 350M. The Size field is showing 470M and the RES field is showing 350M. But my Xms and Xmx is set to 256M. Is this mean the applications are using SWAP space?
-
I am looking for a fast gigabit router
I am looking for a fast gigabit router that has mac supported software. I see lots of vendors selling mac routers, but not fully supporting them. Not that I ever use any of the boxed software, but I would like a company that is mac savvy. thanks, sle