Hi,
we develop a software in C# which uses the TestStand API.
we note that TestStand API allocates memory at the first execution of a TestStand sequence
All the memory of this first execution is not deallocate at the end.
why ?
Is it a problem with Active X technology ?
Is it a conserved memory for the next execution ?
Is it possible to not have this comportment ?
For information, we have deactivated the generation of the TestStand report.
Thanks for the answers
Best regards

There is memory allocated when an execution is run for many different reasons. Please be more specific as to which memory you are referring. Choose one of the following (or add your own if I have forgotten one).
1) Memory used by result collection (to store results under Locals.ResultList while an execution is running). These are typically freed once the process model is done processing them typically for report generation or database logging. By default the process model processes them between runs of the mainsequence on the UUT. These results are also freed when the execution completes (i.e. stops running). If you are not using a process model or do not need results for specific steps or sequences you can disable result collection on a per-step, per-sequence, or global basis.
2) Memory used to keep the sequences and executions themselves in memory. These datastructures stay in memory as long as you have a reference to them. One additional twist with .NET is that you might not think you have a reference to them, but you really still do because .NET hasn't gotten around to garbage collecting the references yet. You can force garbage collection as follows with the following code:
        public static void DoSynchronousGCForCOMObjectDestruction()
            // To make sure activex refs are synchronously released
            // we need to call GC.Collect() and GC.WaitForPendingFinalizers()
            // at least twice, according to the following document:
            // http://msdn.microsoft.com/en-us/library/aa679807%28v=office.11%29.aspx
            // The reason we have to do it twice is that the the first call
            // might just sweep the objects into generation 2 rather than collecting
            // them immediately.
            GC.Collect();
            GC.WaitForPendingFinalizers();
            GC.Collect();
            GC.WaitForPendingFinalizers();
3) Memory used by code modules being loaded. This memory is freed when the step settings on your code modules say to unload your modules, but the behavior is somewhat different depending on the adapter. Some adapters can unload code modules on a per-code module basis, but the .NET adapter can only unload code modules when all code modules and .NET objects created by the .NET adapter are no longer supposed to be loaded or referenced. That is because in .NET the only way to unload code modules is to unload the appdomain containing them. TestStand uses a single appdomain for the .NET adapter and unload that appdomain when all .NET code modules referenced by the adapter are unloaded and all .NET references gotten from those code modules into TestStand are no longer in scope.
Hope this helps explain things.
-Doug

Similar Messages

  • Activating locks using TestStand API

    Hello,
    I have a question... how do I lock and unlock a lock, created in TestStand, in Visual Basic (by using the teststand API)?
    Greetz Jan Toebes

    Hello,
    To understand you correctly you are trying to perform a lock or unlock through Visual Basic. For this you have to use the synchronization server, which has a different API for itself. You can get more information about this under "TestStand Supplemental Reference Help" section in the TestStand Help.
    For simplicity sake, lets assume that you have a lock step created in teststand and you want to perform an unlock using Visual Basic.
    To perform this task, you need the SyncManager. This is the main class for all Synchronization objects. This class helps manage the creation and sharing of the different Synchronization objects between threads. You must create all Synchronization objects using this class.
    To get the appropriate instance of the TestStand Synchronization Manager call the Engine.GetSyncManager TestStand API method. The Engine.GetSyncManager method returns the TestStand Synchronization Manager for the appropriate process based on the name of the Synchronization object. So the call would be
    SyncManager = Engine.GetSyncManager(* Name_of_the_lock_Step)
    where the Name_of_the_Step is the actual name of the lock step that we created in TestStand. The "*" before that indicates that this lock step was created in a separate thread and is being shared.
    Now Mutex is the class that implements the Lock synchronization and is used to implement the Lock step type in TestStand. So using the SynCManager will get an instance of this Mutex class by using:
    Mutex = SyncManager.GetMutex(* Mame_of_the_lock_step)
    Now using Mutex you can perform an unlock by using:
    Mutex.EarlyUnlockMutex ( threadId)
    Please refer to the help for more information regarding these functions. I hope this helps.
    SijinK
    National Instruments

  • Visual Studio TestStand API runtime enable/disable XML reporting file creation

    I am looking for a Visual Studio C# solution to selectively disable creation of the report generation XML file using the TestStand API.
    These XML files are useful for active troubleshooting for technicians, but wind up cluttering important directories with useless information most of the time.
    I am aware that the XML file creation can be disabled through the TestStand Sequence Editor menu item Configure | Result Processing | Output Name Report | Enabled unchecked option.
    This is helpful, but:
    1. I have not found a way to check-uncheck this feature at runtime.
    2. I do not believe that this would be an effective solution for my instal-less Base Deployment Paradigm.
    Any help or ideas would be appreciated!
    Solved!
    Go to Solution.

    Thank you for the quick and concise response James_Grey!
    This is useful, complete, and implementable but not exactly what I was hoping for.
    I was hoping to be able to enable/disable the XML file creation for the currently executing instance of the engine prior to sequence start.
    I would rather not disable reporting through a configuration file that would effectively disable it for all uses of TestStand until it was re-enabled again.
    Are my expectations unrealistic?
    Does anyone have any idea how creation of the XML file can be enabled/disabled for an active instance of the engine prior to sequence start through the API without altering the file based configuration of TestStand?
    I have seen some postings around 2008 that indicate this can be done, but I was unsuccessful implementing those solutions in TestStand 2013.

  • TestStand API: Set relative path

    Dear NI community!
    Could someone help, please, with the following - is there is some option to set file path to code modules, inside test sequence, to have relative, but not absolute path? I add programmatically code modules to sequence steps, but currently they have absolute path. Is it possible to change it to relative with TestStand API?
    Thanks in advance.
    Solved!
    Go to Solution.

    I was wrong. It's possible to manually cut path to file (according to Search Directories of TestStand). Then code modules will be added with relative pathes. But one should be careful - path should be cut correctly.
    For example, I have full path
    E:\Development\source code\supplementary\TestVIs\Code Modules\Service\Print.vi
    My Search Directory is 
    E:\Development\source code\supplementary\TestVIs\
    So, I need to cut like this:
    Code Modules\Service\Print.vi
    and without slash at the beginning!
    Then it will be OK.

  • TestStand API terminate all notification

    I've developed a LabWindows based user interface using the TestStand UI controls and the TestStand API. I have a sequence file that has several cleanup steps, some of which take a while to finish. One function of the user interface is an Emergency Stop button. When this is pressed, an Engine.TerminateAll is issued via the API. The test fixture has 8 sockets which are using the Batch Model TestUUts entry point. Is there any easy way via callback or other means of knowing when all the terminations have completed. I would like to display a popup telling the operator to wait while the cleanup steps are being carried out. I also want to disable the START button and reenable it when the terminations are complete.
    I am launching the execution with TS_EngineNewExecution and I can get the id. I tried to wait until I saw this execution end with the ApplicationMgr  EndExecution event or the Execution VIew Manager EndExecution event but I saw a bunch of exection id's except the one that I was looking for. It may be my fault but I wanted to ask and see what is the best approach for what I am trying to accomplish.
    John

    Hey John,
    Your method will work, and your assumptions are partially
    correct.  If you look in the Batch Process Model, inside of the
    Cleanup Step Group of Test UUTs there are steps that tell all
    TestSocket executions to stop.  There is also a wait step that
    forces the Process Model execution to wait until all of the TestSocket
    executions have terminated. There are going to be multiple EndExecution
    events because it is going to occur for each execution that finishes
    whether it is the Process Model execution or one of the TestSocket
    executions. However, the Process Model will always be after all of the
    TestSocket executions have completed. 
    Another thing to keep in mind is that this is only happening because it
    is built into the process model.  Normally if you spawn off a new
    execution it is separate from your original execution, and the new
    execution would not terminate by calling the terminate method on your
    original execution.  You would have to either do a terminate on
    each execution or use the terminate all method of the application
    manager. Hope this helps to clear things up a little.
    Pat P.
    Software Engineer
    National Instruments

  • Teststand api Creating/deleting Users

    Hi,
    I am using Teststand API with Labwindows and i have a problem with creating/deleting Users.
    In fact, to explain easily my problem when you use the full-featured Teststand  with the "CreateDeleteUsers.seq" sequence and create a user, then close the full-featured Teststand, you loose your new users in the previous opening.
    Whereas, with the Teststand 4.0, with the same "CreateDeleteUsers.seq", when you close, it propose to save the changed file "UserManagement" (Users.ini) and everything's fine...
    And as i am using a Labwindows project to login/logout to teststand, i am using TS_... functions i can't find a way to save or to have this save popup to keep my users.
    I hope that i am clear, and that someone will be able to help me ! 

    Hello,
    As you could see in the following KB: How Can I Edit and Save Changes for the Current User? you have to get the users file as a PropertyObjectFile as it's done in the CreateDeleteUsers sequence, and then use two methods, IncChangeCount() wich is also already done in the example sequence, and the SaveFileIfModified().
    See attached file below for the example sequence changed with the file saving.
    Regards,
    Olivier L. | Certified LabVIEW Developer
    Attachments:
    CreateDeleteUsersAndSave.seq ‏11 KB

  • Load a VI (including TestStand API) in TestStand

    He,
    I'd like to load a VI in TestStand without LabVIEW.
    LabVIEW Version 8.5
    TestStand Version 4.0
    The PC with TestStand just have LabVIEW Runtime Engine 8.5, and the VI is used to import data in station globals; Also, This VI calls TestStand API and TestStand Engine.
    On a PC with LabVIEW and TestStand, all is OK.
    But, on a PC with Runtime only, even if I configure Adapters in TestStand and Select LabVIEW Run time 8.5, an error message is displayed (unable to load VI ... )
    I have tested with a simple VI (dialog box), all is ok;
    But with VIs thaht called API TestSTand, error is displayed
    Do you have an idea ?
    Thank you for your responses
    Solved!
    Go to Solution.

    Yes, I understand that you use TestStand in development system and the VIs are in an llb there. What I ASKED was where you placed the TestStand VIs on the runtime only pc. It sounds like you did not place them anywhere. If you didn't, how do you think the top level VI is going to work? You don't think that these VIs are included in the runtime engine do you? They are not. Only the LabVIEW primatives are in the runtime engine.
    You should really consider using the deployment tool.

  • LabVIEW V'sI containing TestStand API saved on different Windows versions

    Hi.
    I have a question regarding saving and loading of LabVIEW VI's that contains calls to the TestStand API in different versions of Windows:
    Can it be true that if I create such a VI in e.g. 64 bit Windows 7 and then load it in 32 bit Windows 7 or XP with the exact same versions of LabVIEW and TestStand, the VI will need to be recompiled?
    I am currently using LabVIEW 2012 SP1 f9 and TestStand 2012 SP1 f1.
    Best regards
    Jens Christian Andersen.
    Best regards
    Jens Christian Andersen.
    CLA, CTA

    Hi,
    If the labview version is same then it need not be re compiled.
    It will work with different versions of Windows (for both bitness 64\32 OS)
    Ravi

  • Do You Use the TestStand API Reference Poster?

    The TestStand R&D Team would like to know how you use the TestStand API Reference Poster that ships with TestStand.  How often do you use it?  Is it hanging up near your computer?  What tasks do you use it for?
    Allen P.
    NI

    Hi,
    I dont use the hard copy. I unfolded the it the first time it appeared in version 3.0. Refolded it, put it back in the box and have never bothered with it since.
    I have used the electronic version now again, when I haven't got access to the programmer help doc which you find in the teststand\bin folder.
    I find its use limited, as it only really gives you the relationship between classes and a list of the properties and methods. This you can obtain for the help document.
    Regards
    Ray Farmer
    Regards
    Ray Farmer

  • How do you get a handle to a TestStand API SequenceCallModule Object?

    I am trying to programatically specify the SequenceName for a sub sequence, created using the TestStand API called from LabView.  SequenceName is a property of the SequenceCallModule object but I cant see how to get the object handle.
    Can anyone help?
    Regards
    Steve
    There are 10 types of people in the world that understand binary, those that do and those that don't.

    Hi,
      you can actually do this. I was speaking to Steve yesterday on this :
    starting with the handle to the appropriate step (I've done it in the attached sequence file in TS, but should translate nicely to LV)
    so I use the sequence to get the step by name
    I can then get the step.module
    then using the TESTAND ADAPTER API (and not the Teststand API)
    I can use the module returned above with the SequenceCallModule class from the TestStand AdapterAPI then. (you have to know ahead of time what the appropriate module / adapter type is otherwise it will have problems)
    Hope that helps
    Sacha Emery
    National Instruments (UK)
    // it takes almost no time to rate an answer
    Attachments:
    3_0 using adapter specific sequencecallmodule.seq ‏39 KB

  • Teststand API in LABVIEW

    Hello Friends,
    In the sequence editor , i am able to get the TestStand API  RunState.Step.Module.AsLabVIEWModule.RemoteHost = ""
    But i am not able to get the same Teststand API properties in Labview with sequence Context. Herewith in attached the image for your ref.
    Anyone knows how i can get the above teststand API in LABVIEW.
    Thanks
    Prithivi
    Attachments:
    Labview Teststand API properites1.JPG ‏51 KB

    Hi Prithivi,
    you have to cast the Module Reference to LabVIEWModule Type before you can use it. Following document will be useful to you:
    How Can I Programmatically Access Information about a Code Module that a Step Executes (e.g. Name, Path)?
    http://digital.ni.com/public.nsf/allkb/ADC6909C20E27D4886256E94005424E3?OpenDocument
    Regards
    MY
    Attachments:
    LVModule.JPG ‏17 KB

  • How to build a TestStand 2012 workspace ( insert a project / insert a folder) programmat​ically using LabVIEW 2012 and the TestStand API.

    Hi everybody!
    I am just trying to find out how to create a TestStand workspace … in LabVIEW using the TestStand API.
    To create a new workspace was quite easy. Unfortunately I am not successful to insert a new or existing project to the workspace.
    Furthermore I have to insert a folder from disk to the new or existing project in the way that I can use an absolute path for the directory …  
    Maybe someone had already solved this problem, in any case  I am thankful for any hint.
    Greetings from Germany,
    Norbert

    Have you find out how to add a folder to a project? I'm looking for this to... I tried WorkspaceObject.NewFolder[Name]whitout success...
    For creating Workspace and project see the newer resolved thread I created.
    Martin

  • TestStand API External Component Modified Since Last VI Save

    I'm using TestStand 3.5 with LabVIEW, and deploying my code across multiple stations.  The code is managed by Perforce (source code control).  I'm keeping the stations identical by installing NI software from the same CDs (which I'll refer to as an "Original Station"), but it seems that over time the TestStand API will somehow be externally modified ("Modified Station"), which causes LabVIEW to recompile the VI.  The Explain Changes dialog box states "VI recompiled.  External component modified since last VI Save."  If I save the recompiled changes on a Modified Station and submit the changes, an Original Station opening the VI will then recompile VI, stating that an external component has been modified since the last VI save.  If I resave the VI on an Original Station, then the next time I open it on a Modified Station the recompile will occur.
    This is problematic, because there will be a performance hit if LabVIEW has to recompile when opening VIs.  In addition, it makes debugging difficult, because LabVIEW will prompt to save changes on all the VIs if they were saved on a different station state.  Not to mention the unnecessary copies made in the source code control to maintain the history of the recompiling.
    My current solution is to reinstall TestStand on all the Modified Stations.  I set any TestStand strict typedefs that I use to non-strict typdefs, mass compile the TestStand addon folder in vi.lib, and then the station becomes an Original Station again.  Overtime, it will modify itself and turn into a Modified Station.  Since these stations are at multiple sites, it is very inconvenient to manage.
    My questions are the following:
    1. What is causing this external modification?  Is there anyway to prevent it, so that the installation and code will not get modified so that all will remain Original Stations?
    2. If it is not preventable, how can I force all stations to become a Modified Station, so at least they are all the same?
    I've attached LabVIEW 8.5 VIs that demonstrate the VI differences.  I've observed this behavior in LabVIEW 7.1 and 8.2 previously.  If anyone also experience this behavior or has a work around, please post to this thread.  If NI has insight on what is causing this behavior and how to prevent it, it will help me out greatly.
    Thanks!
    Attachments:
    test_recompile_original_lv85.vi ‏7 KB
    test_recompile_modified_lv85.vi ‏7 KB

     Wilbur,
    Do you have more than one version of TestStand or LabVIEW on the stations?   Switching the active version of TestStand changes the registered version of the TestStand API which I believe is the external change that forces a recompile.  If version switching is the cause of the problem you could prevent these changes by not sharing any TestStand VIs between different versions of TestStand.  If each version of TestStand has its own VIs then a VI is compiled against one and only one engine version.
    -Rick Francis

  • Attaching User ComboBox to TestStand API

    I am using a custom interface that gives my application an Office 2003 look incliding the dockable panels and toolbars, I would like to use the ComboBox controls that I normally use rather than the NI ComboBox that comes with TestStand, How do I connect those custom Combo boxes to the TestStand API?

    There is no simply way to connect non-TestStand UI control to a manager control such that it behaves the same way as a connected TestStand UI control. Instead, you must implement the desired behavior in the usual way you program your controls.
    This means you have to use the methods and events that your combo box offers to add and remove items and to respond to user selections.
    To obtain the data to populate the combobox or to perform an action in response to a user selection, you might need to call the TestStand API. Which methods you call would of course depend on what you are showing in the combo box.

  • Using the Teststand API to create a .tpj file

    Hello,
    I'm looking for an example on how to create a teststand project file with the API. I cannot find a methode or property to create it, and add the project file(s) to a workspace. I've tried with PropertyObjectFile (Classe) without success.
    Let me know if you can help.
    Thx
    Martin.
    Teststand 2010 SP1.
    Solved!
    Go to Solution.

    Thx for your answer, i use Labview 8.6 to interact with the API, So i don't know if I interpreted rightly your code...
    I've managed to create an empty project file (.tpj)  with "Engine.NewPropertyObjectFile (6)"
    With the "rootworkspaceObject.NewFile(filePath),0" A pop-up appear to select the file (so it must be created before like above).
    What i've done is:
    - Creating the file as a project file  "Engine.NewPropertyObjectFile (6),(Path)."
    - I write the new file to disk "PropertyObjectFile.WriteFile(format)" and "PropertyObjectFile.SaveIfModified"
    - Then i try to associate The existing .TPJ file to the RootWorkspaceObject "WorkspaceObject.NewFile(Path)" and "WorkspaceObject.InsertObject(Index)"
    -At last I save modification of the association "WorkspaceFile.SaveWorkspaceAndProjectFiles(option)"
    There is no error and when i open the workspace in teststand, there is no .pjt in the workspace tree...What i'm missing...
    So this does not work for me..
    Cheers
    Martin