Third-party not defined in the case of vendor with plant assignment ?

We use a Third-Party Vendor to direct-ship some products directly to our Customers.
When transfers third party order form's PR STO PO, prompts the following information
Third-party not defined in the case of vendor with plant assignment
Message no. 06769
Diagnosis
You are entering a purchase transaction involving a vendor to whom a plant has been assigned. Normally, this will involve the transfer of materials from one plant to another.
This process necessitates a delivery and a billing document in the SD system. The PO appears directly in the delivery due list of the issuing plant (vendor) and therefore does not need to be transmitted.
However, an item with the procurement form "third-party" (triangular business deal) cannot appear in the delivery due list.
Procedure
An item with the procurement form "third-party" can only be ordered from vendors without a plant assignment.
how should solve?
Many thanks,  Adny.
Edited by: Andy Yao on Feb 8, 2010 3:58 AM

Hi Andy
Why u doing stock transfer order,in third party sales there is no stock transfer
Follow below procees for third party sales( Vendor ship materials directly to customer)
Create Sales order(Use item category TAS) >>> Purachase requisition(Automatically from order) >>> Purchase order >>> Vendor Invoice Verification >>> Invoice to customer
Kapil

Similar Messages

  • PR: Procurement w/o material from vendor with plant assignment not defined

    Hi,
    Getting the error message:  06806 - Procurement w/o material from vendor with plant assignment not defined
    while creating the PR with account assingment (P- project) & without material no. instead entering the short text in the PR.
    this issue (Error message) is getting to only one user.
    question-1:  Is it possible to set the Error messages to the user specific. Because other users are able to create the PR with the above inputs, but the one user is not able to create instead getting the above E- Msg.
    question-2: Is it possible to set the messages to Plant specific instead quesiton -1 or both
    Or else, please let me know how to deactivate the above E-msg to the specific user.
    Please do the needful asap.
    Regards,
    Sapsrin

    Hi,
    As you noticed, note 856962 has changed the system behaviour
    when you are working with procurement w/o material from vendor with
    plant assignment.
    Items without a material master record can only be ordered from vendors
    without a plant assignment.
    This note will stop your users from creating service purchase orders
    for a vendor who has a Plant assigned in the vendor master, issuing
    the error message 06 806.
    you can check the below code:-
    LMEPOF23
      IF ekpo-ematn IS INITIAL AND
          (  aktyp EQ hin OR ekko-reswk NE oekko-reswk  OR      "856962
         (  aktyp EQ hin OR NOT ekko-reswk IS INITIAL OR        "856962
            ekko-bsakz NE oekko-bsakz OR
            gf_extended_check NE space ).
        PERFORM enaco_2(sapfmmex) USING '06' '806'.
    regards,
    Lalita

  • Procurement w/o material from vendor with plant assignment not defined

    While creating  standard Framework Order (FO)   asset  PO  I am getting the below error
    "procurement w/o material from vendor with plant assignment not defined"
    Plz Help
    Regards

    Dear INDRANIL BHATTA ,
         Thanks for your reply and your soluation ,
    Finally , I found Vendor Master assignment to plant so it can't create FO PO .
    ->  XK02 -> selecting "purchasing data" >Extras>Add.Purchasing data.

  • Third party system user click the url iam getting error?in sap crm IC

    Hi Team,
    I have given URL to Thrid Party systems.user clicks the link,then he enter the password and username then its getting error like as below..Please help here what settings we need to do.
    Third party system user clicks the URL link ,after entering username password Iam getting error ?
    Thanks
    Kalpana

    HI  Team,
    I have added the parameter crm-ext-integration=true , or we need to any settings for this..Could you please help here..
    Error: TO help protect the security of information you enter into this website,the publisher of this
    content does not allow it to be displayed in a frame
    Thanks
    Kalpana

  • RV13B is not defined in the ABAP dictionary

    Hi Experts,
    Iu2019ve a requirement to create a smartform,and then save it as a pdf and email. I have all of this done except for one part. At present my email address (for testing purposes) is hard coded as the email address. However I want to automatically pick up the email address to which my form is to be sent.
    The email address is found in transaction mn22. The pdf will be emailed to RV13B-PARNR (Partner) based on KOMB-LGORT (storage location). Each storage location is unique.
    Iu2019ve put in the following code:
    SELECT PARNR FROM RV13B INTO CORRESPONDING FIELDS OF TABLE it_vemail[]
    WHERE stor_loc EQ KOMB-LGORT.
    However Iu2019m getting the error RV13B is not defined in the ABAP dictionary as a table, projection view or database view.
    Could anyone give me some help?
    Thanks,
    Mike.

    Mike,
    F1 Technical help will not give you the table name in some cases.Instead of the table it will refer to the structure.In such a case you need to get the corresponding table for that field either from SQL trace or searching the possible tables with such field using SE84 which requires a bit of analysis in zeroing on the correct table where you can get the appropriate data related to that field.
    SE84>>ABAP Dictionary>>Fields>>table fields.
    Give PARNR and get the list of the possible tables containing PARNR as a field.If one is aware of the functionality then it will be easier to zero in on the field and the corresponding table from that list.
    SQL trace can help you in tracing out the possible tables used by a transaction code.ie if you do a SQL trace on VA01 you will come to know all the possible tables of VA01.
    Thanks,
    K.Kiran.

  • Get mapl gives ' mapl not defined in the current logical database'.

    Hello,
    i am going through the report RCPDRK00, i found a statement get plkod , get mapl .
    When i try to run this statement in my test program it says ' not defined in the curent logical database' .
    How to link with  logical database.
    regards,
    kevin.

    GET statements will provide your program with database records based on the code for the logical database. The program in this case is SAPDBPNM.
    Each GET will be supplied with data by the corresponding PUT subroutine.
    Read the help about the logical databases. This is considered obsolete technology, but still, they can be very useful.
    http://help.sap.com/saphelp_nw70ehp2/helpdata/en/9f/db9b5e35c111d1829f0000e829fbfe/frameset.htm

  • After upgrading to OS Mavericks, I realized that the Partition for Windows is gone. I have really important data on this drive without a back up. Is there any way I can get this data before reformatting. Is there any third party software for receiving the

    After upgrading to OS Mavericks, I realized that the Partition for Windows is gone. I have really important data on this drive without a back up. Is there any way I can get this data before reformatting. Is there any third party software for receiving the data or any possible way? Money is not a limitation to this fix. Please help!!!

    sure pretty simple.  make a backup of your current settings
    http://support.apple.com/kb/HT1766?viewlocale=en_US
    then restore device from old backup you need pics off of
    then import pics to computer
    http://support.apple.com/kb/HT4083
    you may need to save pics to camera roll first
    then restore the new backup and sync pics back to phone via itunes
    Peace, Clyde

  • SFLIGHT is NOT defined for the current logical database.

    I have just started learning ABAP and bought an ABAP Objects book by Horst Keller. I have installed 4.6d mini sap and SAP GUI 6.4 on win XP Prof. I executed S_FLIGHT_MODEL_DATA_GENERATOR to load DB tables.
    (1). When I tried to check a sample program, I get an error message SFLIGHT is not defined for the current logical database.
    Here is the partial code:
    REPORT zbcb01f1 .
    TABLES: sflight, sbook.
    DATA: BEGIN OF sr OCCURS 100,
          carrid LIKE sbook-carrid,
          connid LIKE sbook-connid,
          fldate LIKE sbook-fldate,
          bookid LIKE sbook-bookid,
          order_date LIKE sbook-order_date,
          loccuram LIKE sbook-loccuram,
          END OF sr.
    GET sflight.   <---- Error is pointed here
    (2). I am also not getting Graphical Screen Painter when selecting Layout for a screen. Instead, I am getting alphanumeric editor.
    Someone please help me.  
    Raizak.

    Hi Raizak,
    the easiest way is to go to service.sap.com/notes and enter the note number. For this time I've copied the 2 notes below.
    Best regards,
    Christian
    Symptom
    The Graphical Layout Editor of the Screen Painter either does not start or terminates.Error message 37527 is displayed in the session in which the call was made (Graphical Layout Editor not available.
    Additional key words
    () EUNOTE, EUSCREENPAINTER, 37 527
    Cause and prerequisites
    This note comprises all the common causes for error message 37527 and provides you with information on how to systematically trouble shoot the problem.
    1. Windows32 or UNIX/motif?
    As of Release 4.6B there is only the program version for 32bit Windows (NT, 95, 98, 2000 ff.).Up to Release 4.6A there was also a version for UNIX/Motif.All of the more current notes (with the exception of Note 45490) refer only to the Windows version.
    2. Termination at the start or during use?
    The following diagnostic steps refer to the causes of the errors which prevent the Graphical Layout Editor from starting. However, there are also known error causes, which result in the program terminating when the application is being used and which also produce the 37527 error message. This affects -
    Rel.4.6C/D: Termination when attempting to read texts in the logon language -> Note 375494
    Crash after transferring program and dictionary fields. Termination after transferring program and dictionary fields -> Note 189245
    Release 3.1I: Termination after inputting field text -> Note 113318
    3. Is the SAPGUI installation correct?
    The Graphical Layout Editor is automatically installed during the standard installation of the SAPGUI.If you chose a non-standard installation, then you should have explicitely selected its installation (component "Development Tools - Graphical Screen Painter").
    The program executable is called gneux.exe.During the SAPGUI installation it is placed in the same directory as the SAPGUI programms (for example, front.exe) (usually C:\Program Files\SAPpc\sapgui). The following belong to the program:
    - An additonal executable gnetx.exe (RFC starter program)
    - the DLL eumfcdll.dll
    - various eusp* data files (that is, the names all begin with eusp.)
    You can check the completeness of the program installation by starting the program gneux.exe locally in the SAPGUI directory (for example, by double-clicking on the program name in the Explorer window).The Layout Editor is displayed with German texts and an empty drawing area for the pseudo screen EUSPDYND 0000.
    If the installation is not complete, an error dialog box provides information regarding the cause of the error, for example, sometimes the DLL eumfcdll.dll is missing after reinstalling the SAPGUI. For example, the eumfcdll.dll DLL was sometimes missing after the SAPGUI was reinstalled.
    4. System link defined and okay?
    The Graphical Layout Editor is a separate program which is started by the Screen Painter Transaction (SE51) on the Frontend machine.
    Up to Release 3.0F, the programs communicated with each other via the graphics log of the SAPGUIs (gmux).The definition of the environment variable SAPGRAPH may be the cause for the program not being being found where it is.
    As of Release 3.1 G, the programs use a separate RFC link which is set up in addition to the SAPGUI's RFC link.Missing or incorrect definitions of the RFC destination EU_SCRP_WN32 or problems with the creation of the RFC link are the most frequent causes for error message 37527 being displayed.Below you can find the correct settings for the RFC destination EU_SCRP_WN32 (under "Solution").Note 101971 lists all the possible causes for problems with the RFC link set-up. Attention:The Graphical Layout Editor may not be operated through a firewall (for example between the SAP and the customer system) because this does not allow an additional RFC connection in addition to the SAPGUI.
    Solution
    ad 1 UNIX/Motif
    Note 45490 describes possible errors resulting from an incorrect program installation under UNIX/Motif (up to Release 4.6A).
    ad 2 Termination when using
    The above-mentioned notes may contain options for solving individual problems.However, you usually have to replace the program with an corrected version.You can do this either by downloading a patch from sapservX or by installing a more current SAPGUI.The patch is mentioned in the respective note.
    ad 3 Installation
    You either need to reinstall the SAPGUI or manually copy the missing file into the SAPGUI directory.In both cases you should make sure beforehand that a Graphical Layout Editor is no longer running.To do this you can either remove all processes gneux.exe from the process list by using a tool such as Task Manager (on WindowsNT) or exit the Graphical Layout Editor from the Screen Painter Transaction menu via Edit -> Cancel Graphical Screen Painter). Attention:For each session or system an individial Layout Editor process may exist so that, if need be, several processes should be cancelled.
    ad 4 System link
    Up to Release 3.0F:you can either delete the environment variable SAPGRAPH or copy all the files of the Graphical Layout Editor into the directory which is specified by SAPGRAPH.
    As of Release 3.1G:you can use Transaction SM59 to check the RFC destination EU_SCRP_WN32 (expand the TCP/IP connections, select destination EU_SCRP_WN32).If the destination is missing, then you should create it with the following settings:
    - Connection type "T" (start of an external program via ...)
    - Activation type "Start"
    - Start on "Front-end workstation"
    - Front-end workstation program "gnetx.exe" (caution! NOT gneux.exe)
    - Description (optional) "Graph. Screen Painter (Windows32)
      Start Program gneux.exe using the gnetx.exe starter program."
    If you want to start the program from a different directory than the SAPGUI standard directory, then replace the default value under Frontend work station by the complete path name for program gnetx.exe.Transaction SM59 also allows you to check the RFC connection via the pushbutton "Test connection").In this case the system attempts to localize and start the program gnetx.exe.If there are errors, a message is displayed regarding the possible causes (for example, gateway problem, timeout problem or the like).Note 101971 provides a detailed explanation of the problems involved with an RFC connection set-up.As the Graphical Screen Painter requires a functional RFC connection as of Release 3.1G, contact the System Administrator or create an message on the topic Middleware (BC-MID-RFC) if you encounter RFC problems.
    If the program gnetx.exe can be found and started, the banner dialog box with logo, release data and version number is displayed briefly.As the Layout Editor itself is not started, the error cause must be in the installation of the Layout Editor program gneux.exe if the connection test was successful.
    Release 4.5A to 4.6B: Use with Releases <3.1G>.
    The Graphical Layout Editor is downward-compatible as regards the system connection, that is, an RFC-based Layout Editor for example from Release 4.6C can also be used on a non-RFC-based Screen Painter, for example of Release 3.0F.However, the releases mentioned above have a program error which causes a crash due to memory violation in the start phase of the program.Note 197328 describes the solution by installation of the corrected program version.
    Important: Trace file dev_euspNNN!
    If none of the diagnosis steps leads to the cause of the error and to the solution of the problem via the corresponding note, then you should add the contents of the trace files dev_euspNNN (NNN = process number) to the message for SAP, if possible.You can find this file in the current directory of the SAP System, for example under Windows NT in C:\Winnt\Profiles\<user>\SAPworkdir.If several such trace files can be found there, make sure that you use the file which matches the termination time with respect to date and time of creation.In most cases the ERROR message in the last lines of this trace file provides an important note on the cause of the error.
    Source code corrections
    Symptom
    The graphic layout editor of the Screen Painter cannot be started (RFC version).
    Other terms
    () EUNOTE, EUSCREENPAINTER
    Reason and Prerequisites
    This is generally caused by the fact that the RFC connection between the frontend graphics layout editor and the calling screen painter program at the backend cannot be set up.
    Possibility 1: Route permission denied
    In the trace file dev_eusp<Process Id> of the graphics layout editor you find the entry "ERROR in RFCMgr_accept: not accepted", and in the RFC trace file dev_rfc.trc you have an entry of the form "ERROR route permission denied (<Front-Id> to <BackId>,<Service>)".
    If there is a firewall between frontend computer and application
    server, you need to decide whether the port for the RFC of the graphical layout editor can be released here (see Solution 1 below).
    In case no firewall exists between the frontend computer and the application server, in its route permission table, the SAProuter contains either no entry for the frontend computer, on which the graphics layout editor is started, or the entry says that the link is saved by a password.Since the connection is denied, the graphics editor processes exits again, and the screen painter switches to the alphanumeric layout editor.
    Possibility 2: Service 'sapgw<ServiceId>' unknown
    In the trace file dev_eusp<ProzessId> of the graphics layout editor you have the entry "ERROR in RFCMgr_accept: not accepted", and in the RFC trace file dev_rfc.trc you have an entry of the form "ERROR service 'sapgw<ServiceId>' unknown".
    The service sapgw<ServiceId> (for example, sapgw00) is not known on one of the computers participating in the RFC communication because the corresponding entry is missing in its service file. The affected computer can be the frontend computer or the gateway computer.
    Possibility 3: The system parameter gw/cpic_timeout value is too low
    This system parameter determines how many seconds the gateway is waiting for the RFC connection to be set up.In case of a high network load, the default value of 20 seconds is too small with the result that the connection cannot be created on time.Here the graphics layout editor process also exits with the trace file entry "ERROR in RFCMgr_accept: not accepted".
    Possibility 4: System parameter abap/no_sapgui_rfc set
    The profile parameter abap/no_sapgui_rfc of the system is set (that is, it has a value not equal to space or 0).This prevents the program of the graphics layout editor from being started with RFC at the frontend.
    Possibility 5: Unnecessary authorization check
    The error message "No RFC authorization for user xxxxxx" is generated although the check of the RFC authorization was deactivated by profile parameter auth/rfc_authority_check (value = space or 0). The problem is caused by a program error, that ignores the value of the profile parameter let during the call of the RFC authorization check (see Note 93254). This error can occur as of Release 4.5.
    Solution
    ad 1) If a Firewall is installed between frontend computer and the application server, you need to decide whether the port for the RFC link of the graphical layout editor shall be released in the firewall. This is port 33nn, where nn is the 2-digit system number of the SAP application server. As of Release 3.1G, the graphical layout editor needs an RFC link for communication with the application server in addition to the already existing linkof the SAP GUIs. Such a second link is not allowed by the firewall in general because it would contradict the security concept (password protection, logging of the connection).
    If no firewall exists, you should check whether the frontend computer can be added to the route permission table or whether the password option can be removed from out of the available entry.
    For details refer to chapter 4.4 of the attached Note 30289.
    ad 2) Include service sapgw<ServiceId> in the service file.
    Refer to Note 52959 for details.
    ad 3) Increase value for system parameter gw/cpic_timeout. 60 seconds should be sufficent as a timeout limit.
    ad 4) Set the system parameter abap/no_sapgui_rfc to space or 0
    Start the application server so that the new parameter value comes into effect.
    ad 5) Import the Support Package specified in the attachment for the release in question or implement the advance correction in the source code as described in the attached correction instructions.
    As a workaround, assign RFC authorizations as described in Note 93254.

  • UWL displaying workflow NOT defined in the XML

    Can someone tell me why/how some workflows are displaying in UWL even though the workflows are not defined in the XML file?

    Hi Daniel,
    This is the case for many "legacy" workflows launching SAP(Web)GUI transactions or BSPs.
    It works like this: if the UWL cannot find a corresponding task type for an arriving work item from Business Workflow in its XML configuration, it assigns the task type "uwl.webflow.default". In the standard uwl xml file you can see that tasks of this type are launched using the SAPTransactionLauncher (not specifying the TransactionCode parameter).
    As you can see in the documentation (https://help.sap.com/javadocs/NW04S/SPS09/uw/com/sap/netweaver/bc/uwl/config/doc-files/ActionHandlers.html), if the TransactionCode is empty, the action handler defaults to the Business Workflow transaction "SWK1". This transaction (the UWL is now out of the picture) just redirects to the target transactions defined in the workflow itself.
    Any matching entry in the UWL XML configuration will however override this default behavior.
    Good question though. Hope this clarifies it to some extend...
    Best,
    Matthias

  • SHIP TO PARTY NOT DEFINED FOR CERTAIN SALES AREA

    Hi ...
    I am creating a specific type of sales order in va01 by reffering a billing document . But soon after entering billing document no it is showing " SHIP TO PARTY NOT DEFINED FOR CERTAIN SALES AREA..." The sales area --- which it's showing in error it is quite different ....it's not that one what we used for it in that ref billing document .
    Note : We are maintaining ship to party  , sold to party ..... in CRM only
    Their also I checked it is assigned properly .Relatioship with sold to party is also OK .
    But in R/3 I have checked that ship party is created in VD01 Where as sold to party is created in XD01 .
    PLS ADVC

    Dear Sundar,
    Please check in these areas
    1.Check the sales area which you are trying to create sales order and copying invoice sales area is same or not.
    2.Why you haven't created ship to party in XD01 transaction.
    You go to XD01 transaction exetend the customer master then try.
    3.Check the customer master(Ship to party) is available under which sales area.
    I hope it will help you,
    Regards,
    Murali.

  • Ship-to party not defined for sales area

    Hi all,
    I am really confused while creating a sales order, I need your help.
    My sales org. - 1083, distribution channel - CY, Division - CW.
    When I enter va01, in the initial screen I enter the above details. Then it goes to the create sales order screen where I enter my customer details.
    After that, I enter my material number and quantity, it is giving me an error ship-to-party not defined for sales area 1084 CY and ZO ( other division) instead of 1084 CY and CW.
    Where did I mess up ?
    Thanks,
    -Chandru

    Hi,
    Go to SPRO - SD - BASIC FUNCTIONS - PARTNER DETERMINATION Just check whther your partner function (SH) is assigned to your account group and also exists in the partner determination procedure.
    Just try and maintain it there against your account group and against your sales document type in VOV8.
    Also open your customer master for which you are trying to create this sales order. Just check whther in the partners tab , SH is shown? You can either use transaction BP or XD03.
    Let me know, reward points if helpful.
    Regards
    Ravi

  • Compatability of LabView RT with Third Party( NOT N.I ) PXI chassis

    I want to use NI LabView and LabView RT, some PXI chassis of N.I and
    some PXI chassis of Third Party( not N.I ) for diversity, How I will Install
    Pharlap ETS ( LabView RT ) on those third party PXI's.
    More simply
    Third party PXI chassis and controllers support LabView RT or not?
    Note: Mark Andre Hary [email protected] of Sensing Systems LLC answer to this question as:
    "You can't.  I think NI bought Pharlap, and they do not offer board support packages (BSPs) for non-NI PXI controllers.  There is no way to get LabVIEW-RT running on a controller not purchased from NI.  You will have to use a standard RTOS like Linux,VxWorks, or QNX.
    Regards

    Hello,
    You can install LabVIEW RT ETS on a third party PXI controller just as if it were a PC.  Check the requirements that a PC needs to have in order to run LabVIEW RT ETS.
    Check the following link:
    http://digital.ni.com/public.nsf/3efedde4322fef19862567740067f3cc/cb3434da94466dd286256e9e006bb775?O...
    Ricardo S.
    National Instruments

  • Data Source Z*** is not defined in the source system

    Hello All,
    I am facing a well known problem extracting data from R3 to the BI side. On both sides I've got SAP ALL.
    I created data source on R3 DEV side, tested it and it extracts data. I've replicated metadata on BI side and activated the data source. The problem starts once I create the info package as no data is availble in PSA.
    I went to extractor checker and tried to start the extraction and I could see the message: data source Z**** not defined in the source system.
    I tried to locate the data source through RSA5 and I cannot see that it is availble there.
    Can you please help and advise where the problem is?

    Hi Neb,
    It can be related to many issues, one of them can be RFC connection issue. Please check the link below :-
    Datasource xxx is not defined in the source system
    It might give you some of ideas. Also if possible can you tell what Datasource are you having problem with.
    Regards
    Sunny

  • Namespace not defined in the SWCV error

    Hi Experts ,
    I am new to PI.
    I am executing one IDOC to IDOC scenario for MATMAS05.
    I have done all the source side, integartion server and destination side server configuration.
    Source:SAP R/3 server
    Int server:PI
    Destination : SAP ECC 5.0
    I have imported the MATMAS05 IDOC.
    Created one name space under my predefined SWCV.
    Then i copied that IDOC to both the source and destination in message mapping.And map all the red mark required filed of the target with source.
    While activating the message mapping I am getting one error.
    Namespace http://piidcoctoidoc is not defined in the software component version MANISHASC2 , 1.1 of manisha.co
    and
      Mapping not sufficiently defined
    Can anybody help me how to resolve this?
    Thanks
    Manisha

    hi Manisha
    while activating the objects which you have created , you must be  getting this error\
    so while activeting the object select your Software component also and activate both then you will not be getting the error
    becuase every time you generate a namespace in any software component then you need to activate the software compnent along with the object
    if you left SWC and activating only the object then you must be getting this error.
    for activating any objevt your software component must be activated first
    what you must be doing ,,,,,, you are activating only the object  and not your software component
    so activete both first your software component and then your object
    Thanks
    sandeep
    If helpful reward points
    Edited by: sandeep sharma on May 16, 2008 1:04 PM

  • The tax code entered is not defined in the company code country.

    Dear sap guru's
    I am facing a problem while doing invoice or while cancelling the invoice or even during Subsequent Credit/Debit
    Tax code V0 in procedure  is invalid
       Message no. FF704
    Diagnosis
       The tax code entered is not defined in the company code country.
    System Response
    Procedure
       Check and, if necessary, correct the entry.
    Procedure for System Administration
       If it is not an input error, check and possibly change the system
       settings.
       To do this, choose Maintain entries (F5).
       1.  Check whether the required tax procedure has been allocated to the
           company code country. The Procedure field is on the detailed screen.
       2.  If you need a new tax code, you can create one yourself.
    For this i have checked the assignment of company code and tax code V0 in Tcode (OBCL)
    In FTXP the tax code is created in country IN, for the same tax procedure and the tax is a input tax.
    please suggest what could be the exact problem
    Regards
    Sujit

    Hi Sujit,
    1.Go to FTXP and create tax code V0 for country IN and procedure ZAXINN.
    2.In Txn: FV11, For the condition type- XXXX (You will get this in Txn: FTXP, against the tax type, you get the condition type OR in the PO-Item details- Invoice tab, next to field: Tax code, see the Tab-Taxes, click on it and will get the condition type) , maintain the country-IN, Tax code-V0 and the rate.
    3.Also things to be checked
    1> assign country to company code
    2> assign company code to tax code
    3> create tax code for country IN
    4.Under the following menu path, pls check if you have assigned your tax code to Company Code
    IMG>Logistics (General)>Tax on Goods Movement>India>Basic Settings>Determination of Excise Duty>Condition Based Excise Determination>Assign Tax Codes to Company Code
    Hope it clears,
    Rahul.

Maybe you are looking for

  • Is there a way to make book covers larger on the shelf in iBooks?

    Hello.  I use my iPad for business.  I have all of my catalogs on my iPad in iBooks.  Part of the problem is that when my clients and I are looking at the catalogs the covers are very small on the book shelf so sometimes we overlook some of them.  Is

  • Closing a PO

    Hi Can anyone explain me what are the different ways in which we can close a PO?. If the POs is closed, how to know that this PO is closed?. Is there any report to see the closed POs and Open POs seperately? Thanks in advance

  • Creation of condition records in FV11

    Hi,      When we using transaction FV11 and giving condtion type say for example JMIP, it populates the following key combination to select from: Plant/Vendor/Material Country/Plant/Ctrl code/Material Country/Plant/Ctrl code Country/NBM-NCM Code Plan

  • Hey guys how to fetch data from db table using subroutine

    hi guys,                I am fetching data from db table "mcha". now in the follwing code i get it in "HSDAT1_DATE."                now when i read out_tab with key "HSDAT1". it wont come in out_tab-value.plz tell me what is wrong whether some key co

  • PC Error

    Hello, i am trying to run this sap provided process chain which has an abap program variant in it but keep getting this error "Start program RSTCC_START_DELTA_PC with program variant RSTCC_QRUNTIMEStart program RSTCC_START_DELTA_PC with program varia