Time Constraint assignement to Subtypes of an infotype.

Hello All,
Where do we maintain Time constraint assignment to subtypes of an infotype. I am looking to subtypes of IT 0210 ( Tax With holding ) " where do we create the subtypes and their characteristics for this infotype in IMG? I tried in view V_T591A but there is no entry for this 0210 infotype but I can find the time constraint assignment for the rest of the infotypes in this view.
Thanks,
Chakri.

try the following
SPRO>Personnel Management> Payroll>Payroll:USA>Payroll Results Adjustment-->Define Time Constraints for adjustments
select infotype 0210 & maintain
~Suresh

Similar Messages

  • IT2006 Time Constraint with Multiple Subtypes

    My client is utilizing 2 different subtypes in IT2006 for a particular personnel area.  The 2 subtypes are vacation (98) and floating holiday (50).  Since each employee will have 2 IT2006 for the year - one for subtype 50 and one for subtype 98, their configuration was set up to issue a warning message when the second record is entered with the same date parameters.  The problem arises when more than one IT2006 with the same subtype is entered for the same time period - SAP allows you to do this. 
    Is there any way to set up the time constraint on the subtype so that not more than one can be entered for the same time period?  They can change the program to check for the existence of a record for the year, but if there's a way to control this via configuration, please let me know!
    Thank you!

    That is actually set up correctly.  There are 2 types of qabsence quotas, one for vacation and one for holiday.  The reaction cannot be an "E" because then an employee could only have one or the other quota, not both.  Every employee needs to have both.  So the reaction has to stay at a "W" (could also be a "N").  And the subtype constraint needs to stay at a "Z" and not a "T" because checks need to be made with other time infotypes so someone doesnt' try to input 8 hours vacation along with actual working hours.
    It's sounding to me like there are no other configuration areas that will remedy this issue and they'll have to check for the existence of a record in the program.
    Thanks.

  • Time Constraint assignement to PD infotypes based on Subtypes.

    Hello All,
    Is there a  way to assign Time contraint to PD infotype like 1005 based on Subtypes? If so how can we do this? I tried in table T591A but I guess this table is only for PA infotypes.
    Thanks,
    Chakri.

    Hi,
    Goto to sm30 and give T777I.  There choose your infotype and click the time constraint. You can give the subtype and time constraint.
    Balaji

  • Time constraint of Subtype

    Hi
    For the Infotype's Time constraint we can use the table T582A,
    But how to get the Subtype's Time Constraint?
    Thanks & regards
    Manjari

    HI,
    Refer to the link.
    Time Constraint assignement to Subtypes of an infotype.
    Regards
    Sumit Agarwal

  • Time Constraint for Subtype

    Dear All,
    I have created Customer Infotype 9909 having Five Subtype. Now I have to give Time Constraint to each separate subtype. please guide for the same.
    Regards
    Mangesh

    Dear All,
    My created Infotype 9909 having Five Subtype like 1,2,3,4,5 and I have give Time Constraint i.e. 1,2,3 to each separate Subtype. Like same example you will find for Infotype 0006 of Address. For Infotype 0006 the Time Constraint is "T" but there is separate Time Constraint for each subtype of 0006. You will find it in Table T591A. I am sending the following values of Infotype 0006 with its Subtypes having Filed "ZEITB" which shows different Time Constraint for its Subtypes. So like that I want to maintain separate Time Constraint for each Subtype of created Infotype 9909.
    MANDT     INFTY     SUBTY     ZEITB     OBJRQ     STEXT
    800     6     1     1          Permanent residence
    800     6     2     3          Temporary residence
    800     6     3     2          Home address
    800     6     4     2          Emergency address
    800     6     5     2          Mailing address
    800     6     6     2          Nursing address
    So please let me know the solution.
    Reagrds
    Mangesh

  • Time constraint of infotype based on subtype

    Hi,
         I have created a master data infotype with different subtypes 0001,0002,0003,0004, etc. I want a time constraint 1 for subtype 0001 and 3 for all other subtypes.
         I would like to know the steps required for configuring the infotypes time constraints based on sub types.
         Kindly help.
    Regards,
    Satish

    Hi Sayantan,
        Thanks.
    Regards,
    Satish

  • Infotype 0185 Personal IDs and time constraint

    Hi people,
    Can you help me... is it possible to set different time constraint for different subtypes in infotype 0185 Personal ID's and where?
    Thank you,
    Romano

    Hi guys,
    thank you for your asnwer, I can see that in table V_T582A we can change time constraint for the whole infotype, but unfortunatelly I can't set different time constraint for different subtype in infotype 0185.
    I want to manage that for subtype 01 i have time constraint 2 and for subtype 02 time constraint 03.
    It is possible for example for infotype adress (0006) but i don't see where is it possible for infotype 0185.
    Thank you.
    Romano

  • Time Constraint Class

    What is the number (0 to 7) stands for time constraint class in absence for the screen number 2001. I have a leave type CL (causual leave). What time constraint class shall i assign to it.
    Regards,
    Chinmay

    for ur info alreadt raghu has given the answer any way check this tooo
    A: Only one record may ever exist for the infotype (from 01/01/1800 - to 31/12/9999). Infotypes with time constraint A may not be deleted.
    B: Only one record may ever exist for the infotype (from 01/01/1800 - to 31/12/9999). Infotypes with time constraint B may be deleted.
    T: Time constraint varies depending on subtype.
    Z : Refers to time management infotypes.Time constraint for these ITs depend on time constraint class in table V_T554S_I. Collision checks : V_T554Y
    Apart from 1, 2, 3 there are some other types of Time Constraints: A, B, T, Z.
    The Infotypes with TC type A must exist, must have only one record in its lifetime, and these ITs cannot be deleted.
    Example: IT0003 (Payroll Status)
    The Infotypes with TC type B must have only one record in its lifetime.
    Example: IT0031 (Reference Personnel numbers)
    The Infotypes with TC type T will have subtypes, and the TC is based on the subtype.
    Example: IT0009 (Bank Details)
    The Time Mnagegement Infotypes will have TC type Z .
    Example: IT2001 (Absences)
    rule that determines whether collisions in time data are allowed, and if so, specifies how the system reacts to such collisions.
    Time contraints comprise the following:
    Time constraint classes that determine which collisions in time data records are allowed
    Time constraint table that contains the time-based collisions allowed in the time data records
    Time constraint indicator that displays whether a new data record that collides with an existing time data record can be transferred to the system or whether the transfer is prohibited
    When you update an infotype, old data is not lost but archived for historical evaluation. The system records a specific period of validity for each infotype, This enables the system to store more than one infotype record at the same time, even if their validity periods overlap. This means that the time relationships between infotype records must be defined. The concept of time constraints enables you to do this.
    HR master data uses the following three time constraints:
    Time Constraint 1
    For the entire time that the employee works at the enterprise, exactly one valid infotype record must exist. The validity periods of the individual records must not overlap. If a new record is created, the system automatically uses the start date of the new record as the delimitation date of the old record. Gaps are only allowed between the employeeu2019s entry date and the start date of the first record.
    Time constraint 1 must be used for all of the infotypes containing information that must be available at all times. This is particularly true of personal and organizational assignment data.
    If a record is delimited because of time constraint 1, the system displays an appropriate message.
    Time Constraint 2
    No more than one valid record can exist at any one time. Records with constraint 2 must not overlap. Their existence is not obligatory. If a new record is created, the system automatically delimits the previous record, if one exists.
    If a record is delimited because of time constraint 2, the system displays an appropriate message.
    Time Constraint 3
    Any number of valid records can exist at any one time. The individual records do not conflict with each other.
    Time Constraints:
    When an info type is updated, the old data is not lost. Instead, it remains in the system so that you can perform historical evaluations. Each info type is stored with a specific validity period. This means that the system can contain more than one record of the same info type at the sometime, even if their validity periods coincide.
    If you enter and save new information in an info type, the system checks whether the record already exists for this info type. If this is the case, the system reacts based on rules or TIME CONSTRAINTS set up for that particular info type or subtype.
    Time Constraint 1: This is mandatory information that must be uniquely available, gaps are not allowed
    Time Constraint 2: This is optional information that, if available, must be unique, gaps allowed.
    Time Constraint 3: This is optional information that, if available, can exist more than once.

  • Time Constraint Classes.

    Hi All,
    Pls let me know the concepts for Time Constraints classes.
    Regards
    Rajesh

    A time constraint indicates whether more than one infotype record may be
    available at one time. The following time constraint indicators are
    permissible:
         -   1: An infotype record must be available at all times. This
             record may have no time gaps. You may not delete the record last
             stored on the database because all records of this infotype
             would otherwise be deleted.
         -   2: Only one record may be available at one time, but time gaps
             are permitted.
         -   3: Any number of records may be valid at one time, and time gaps
             are permitted.
    Other possible time constraint indicators are as follows:
         -   A: Only one record may ever exist for this infotype. It is valid
             from 01/01/1800 to 12/31/9999. Splitting is not permissible.
             View V_T582B Infotypes Which are Created Automically controls
             whether the system automatically creates the infotype record for
             an employee hiring or an applicant data entry action.
             Infotypes with time constraint A may not be deleted.
         -   B: Only one record may ever exist for this infotype. It is valid
             from 01/01/1800 to 12/31/9999. Splitting is not permissible.
             Infotypes with time constraint B may be deleted.
         -   T: The time constraint varies depending on the subtype.
         -   Z: Refers to time management infotypes. The time constraint for
             these infotypes depends on the time constraint class defined in
             view V_T554S_I Absence: General Control. Collision checks are
             defined in view V_T554Y  Time Constraint Reaction.
    Regards
    ...Sadhu

  • Time constraints and Dialog module

    1.What is the difference between the time constraints A(IT exists just once from 01 Jan 1800 to 12 Dec 9999) and B(IT exists for maximum of once from 01 Jan 1800 to 12 Dec 9999)?
    2.What is the necessity of dialog module for a Infotype?

    Time Constraint A and B
    Infotypes with time constraint A & B must have no more than one record. The system automatically assigns the record a validity period from January 01, 1800 through December 31, 9999. This validity period cannot be subdivided.
    Infotype records with time constraint A CANNOT be deleted.
    Infotype records with time constraint B CAN be deleted.
    The difference is check the BOLD TEXT.
    As for ur second question, Function modules/dialog modules helps calling infotypes when called from any custom program ,and allows you to perform similar actions/tasks that you would perform on them from direct maintainance. ex: create,change, delete etc. also performing the same on multiple infotypes in a single go using a them is easier than writing a code to manipulate each single infotype.
    SAP exposed these functions to be exploited as there will come many situations in business scenarios where you require to work with them by writing custom code.
    hope its helpful

  • Calendar time constraints

    I started another thread about this but have had no replies. I know this means no one has a fix, but it would help a lot to know the answer to this question:
    Is anyone currently syncing calendars - iCal or Entourage - to an external device, particularly a Nokia phone, where the iSync time constraints - "Don't sync events older than:..." and "Don't sync events after:... - are actually working?
    I've established that I'm not the only person for whom they no longer work, but if I can find someone for whom they do actually work, then I'll keep debugging my system, instead of looking for a workaround and hoping it's fixed in the next update.
    Thanks in advance,
    Steve = : ^ )

    A time constraint indicates whether more than one infotype record may be available at one time. The following time constraint indicators are permissible:
    1 = An infotype record must be available at all times. This record may have notime gaps. You may not delete the record last stored on the database because all records of this infotype would otherwise be deleted.
    2 = Only one record may be available at one time, but time gaps are permitted.
    3 = Any number of records may be valid at one time, and time gaps are permitted.
    Other possible time constraint indicators are as follows:
    A = Only one record may ever exist for this infotype. It is valid from 01/01/1800 to 12/31/9999. Splitting is not permissible.
    View V_T582B Infotypes Which are Created Automically controls whether the system automatically creates the infotype record for an employee hiring or an applicant data entry action.
    Infotypes with time constraintA may not be deleted.
    B = Only one record may ever exist for this infotype. It is valid from 01/01/1800 to 12/31/9999. Splitting is not permissible.
    Infotypes with time constraint B may be deleted.
    T = The time constraint varies depending on the subtype.
    Z: Refers to time management infotypes. The time constraint for these infotypes depends on the time constraint class defined in view V_T554S_I Absence: General Control. Collision checks are defined in view V_T554Y TimeConstraint Reaction.

  • Address IT 0006 and time constraints

    Hi all,
    I am trying to understand the concept of address IT 0006 with relation to time constraints. Can you please provide your valueable inputs along with some examples. I understand the concept of time constraints but trying to get this concept in relation to IT 0006.
    Thanks
    Priyanka

    As Sikander mentioned, you should have lots of threads on this already, but to your question what time constraint means to address really is identifying different address subtypes and how they exist within the lifetime of the employee.
    For example, Subtype Permananet Address should exist only once for an employee from start to end. If any changes are made, the previous record should be end dated and a new record should begin with changes.
    Same is the case with Mailing Address.
    However there can be several Emergency Addresses for the employee at the same time.
    So different time constraints for different subtypes control this behavior
    Check Table: v_T582A for IT6, Time Costraint is T, which means u need to look at the V_T591A table

  • Change time constraint of Infotype 0006 subtype 1 and subtype 2

    Hi
    Can anyone tell me how to change the TC of infotype 0006 subtype 1 and subtype 2.
    Currently I tried to change the TC in table V_T582A but its giving me an error : "Text maintenance not permitted as infotype part of Data Sharing (T582G)  "
    Can anyone please advise.
    Currently the TC is T
    I want to change it to 2.

    hi ,
    you can use SE38 to create a report like :
    to change the time constraint for IT0006 +subty 1 + 2
    REPORT  ZTEST.
    tables: t591a.
    data: wt_tc type table of t591a.
    select * from t591a into table wt_tc where infty = '0006' AND
                                                 ( subty = '1' OR
                                                  subty = '2').
    if sy-subrc = 0.
    loop at wt_tc into t591a.
    t591a-zeitb = 'x'. "new TC that you need
    modify table t591a from t591a.
    endloop.
    endif.
    regards

  • How to make a custom infotype field the time constraint 1?????

    Hello everyone I have this challenging question for gurus to answer it.
    In custom created infotype for OM Ii have that field called ZZJOBID. When infotype was created I assigned the time constraint 1 for that infotype. That time constraint was base on OBJID not on ZZJOBID. Now the problem I am encountering is when I assign the 2nd ZZJOBID  with time span 01011800-12319999 it overwrite the 1st assign ZZJOBID.
    for the requirement reason I have to use PO10( not po03). If I change the time constraint to 3 which let me have the multiple records but I am losing the delimit and other functionality which comes with time constraint 1.

    Suresh,
             you are wright when you say that ' Time Constraint is for the Infotype/Subtype record and cannot be based off a field.' The OM infotype runs on bases of Object such as Organizational Unit, Job, etc... The point I was trying to draw is I am looking for a way that allow me to work via TC PO10 which run on Organizational Unit along with different ZZJOBID (with same begda and endda, if needed).

  • Time constraint 'T' for custom infotype

    HI experts,
    Im creating a custom infotype and i want to assign time constraint 'T' for that infotype. But while assigning the time constraint in Infotype characteristcs in PM01, it throws the below error message.
    "TIme constraint T is not allowed for 9021 infotype".
    Pls tell me what is the pbm here and how to solve the problem?

    Hi,
    Try this.
    If a subtype needs to be maintained for the Infotype then some additional steps also needs to be performed
    before providing Infotype characteristics
    1. Select the Technical attributes from the initial screen of PM01 transaction .You will see a list of RP_XXXX where XXXX is infotype.
    2. Select the change button on application tool bar. The dialog module in the above screen then becomes
    editable.
    3. Select the Infotype 9021 and select the details button. Make sure you are in change mode.
    4. Provide the Subtype field of the Infotype, Subtype table as T591A and Subty.text table as T591S.
    5. Save and go back to the initial PM01 screen.
    6. The subtypes for an Infotype can be entered via the maintenance view V_T591A.
    Now try maintaining time constraint T with view V_T582A through SM31.
    cheers
    Ajay

Maybe you are looking for

  • What customers can expect from BT customer support...

    (In reply to the email at the bottom of this post. I am happy to discuss this with other members but please familarise yourself with the post first. I know its a long one, but I tried to make it as detailed as possible) Hi Samia, I don't want to give

  • Locked out of mail have to unlock every time I try to access it.

    I have been using my mac (mini) for a couple years and have always had macs, so I;m not an idiot (meh)-Just recently I have been locked out of my mail every time I try to use it, with either "disabled for security reasons" or "unable to connect to iC

  • Photo Order in iCloud Sharing

    How can I keep my photos in the same order as they are in the album, once I upload to iCloud Photo Sharing?

  • Movie Playback on the iPod

    I've converted the movies to play on the iPod. When I select a movie to play on the iPod, I only get a small picture of the first frame in the upper left side and the cursor on the bottom moves like it is playing. How can I view the movies full scree

  • Driver alias changes during installation of Solaris

    I have a HP LP1000r Netserver. It's a little 1u box with a hardware pci raid controller that is giving me some grief. The card is a HP NetRaid-1M. This card is bascially an OEM version of the AMI MegaRaid 475(Express 500). AMI's raid cards were bough