Time stamp in S&OP system
Guys,
Our S&OP servers are running in EST timezone but out Data Integration shows UTC timezone...I remember reading some thing about UTC timestamp in Data integration HANA procedures but I can't recollect now.
I have few questions and any insights appreciated.
1) Are there are any app or user level settings for timezone (I did check global parameters and didn't find any clues) in S&OP.
2) How to determine what time stamp being used by WEB UI or Excel UI?
Thanks,
Krishna
SAP released a OSS Note for On-premise customers...Note number 2114605 and SAP will add this to next patch..
Thank you SAP for release fix for this...
Thanks,
krishna
Similar Messages
-
Hi All,
I am using Labview8.5 and Windows XP OS.
My Problem is my Labview TimeStamp cannot display current system date and time.
Please see my attachment for the screentshot.
The TimeStamp or ever Format Date/Time String display "YYYY-MM-DD" instead of "2014-08-02".
I tried other computer machine and it works. There are some computer machine has this problem.
How can I resolve this issue? Please advice. Thanks.
Best Thanks,
Jessie
Attachments:
Time Stamp error.JPG 68 KBBill,
reviewing the thread Dennis linked (thanks for that) reveals that it is the same account which opened this thread here three month later.
What bothers me is the fact, that the past thread is marked "solved" even though it obviously isn't. Or the OP is trolling us.....
Nevertheless, it seems like systematic error. Connected to specific machines.
What makes the machines where the time stamp issue occurs "unique"? If there are several, is that source really "unique"?
Most obvious reasons would be:
- Language settings (possibly the infamous "dot-comma-issue")
- Time zone settings (e.g. what happens if you switch Ulaanbaatar to Perth or maybe even some US time zone?)
- Missing hotfixes for Win and LV
- Is the system running as virtual machine vs. "native"?
Not so obvious differences:
- Specific CPU type
- Motherboard/BIOS
- LV ini settings
There are tons of other possible reasons (e.g. corrupt LV installation), but these are the ones i came up with within a couple of minutes....
Norbert
CEO: What exactly is stopping us from doing this?
Expert: Geometry
Marketing Manager: Just ignore it. -
Time stamp control dialog kills System Exec.vi !
Hello!
I just experiance a really strange behaviour in my application. I managed to reduce it to a much smaller VI, please do not look at the framework but at the actual problem, this test MAIN vi looks like this since it is a skeleton of a bigger application (i had to remove many non-relevant and confidential parts).
So. I have a USB watchdog relay from a 3rd party company, which I can use perfectly in my application via a supplied EXE. I call this exe from LabVIEW using the System Exec.vi , and it works perfectly and the Watchdog functions as it should. However I see a strange bug (?): if I launch a Time stamp control dialog browser window, it "pauses" somehow the System Exec.vi. So my watchdog command setting stops, relay opens, problem!
I zipped my test application and I can reproduce this same problem even if I just call a command line PAUSE win command. Note that, in my real application, the Time stamp control is located in a separate, dynamically callled (call and forget method) VI, but I get the same bug!!!
Steps to reproduce the bug:
start my application
observe as the bottom loop iterates
Click on the Time Stamp control's browser to pop-up the dialog window.
You can see the iteration of the bottom loop stopped (DAQ loop iterations)
if you close the dialog window, the bottom loop continues execution
What the heck is this???
How is this possible, why there is "interference" between a totally separated control and a bottom loop System Exec.vi ???
Thanks for any suggestion!
In my real app, as a workaround, I just hide the browser element of the Time stamp control...
Solved!
Go to Solution.
Attachments:
HYDE_loop_software.zip 348 KBThanks! Yep, I can do a workaround, like create my own time stamp dialog window to pop-up if i wanna be "fancy".
But this is important to keep in mind, if we use the SystemExec vi!
If someone can explane this issue/feature deeper, I will be happy, but I mark this above post as solution, thanks! -
How to get system time format in time stamp
Hello All,
I have one problem regarding Time stamp. I want system time stamp format in Time control. If my system date/time format change then automatically my time stamp format should also change.If my system Time stamp format is hh:mm:ss AM/PM dd/mm/yy so in my LabVIEW time stamp format should also same. If System time stamp format hh:mm:ss AM/PM mm/dd/yyyy so in my LabVIEW time stamp format should also same.
So Please help me its a very important for my automation application.
Thank You.
Vinal Gandhi
Kudos are always Welcome.... :-)
Vinal Gandhi, CLD
Software EngineerHi Vinal,
have you tried the FormatDateTimeString function with a standard string indicator and the "%c" formatcode as described in the help instead of the generic timestamp indicator?
Best regards,
GerdW
CLAD, using 2009SP1 + LV2011SP1 + LV2014SP1 on WinXP+Win7+cRIO
Kudos are welcome -
Hello,
I got mistake in ODS manage like this:
The time stamp in the source system is 24.09.2007
The time stamp in the BW is 23.05.2009.
I have problem to load data in ODS.
What should I do ?? Replicate the data source ? But then it's possible to get double data. What to do ??
THXI replicated data source, source system and loaded data one more time and I have got the same mistake.
this:
Error message from the source system
Diagnosis
An error occurred in the source system.
System response
An error occurred in Service API .
Check the error message.
Procedure
The procedure for removing errors takes place depending on
the error message:
Note
If the source system is a Client Workstation, then it is possible that the file that was to be loaded was being edited at the time of the data request. Make sure that the file is in the specified directory and is not being edited, and restart the request.
AND ALSO mistake WITH TIME STAMP -
SAP PI - Windows OS Generated Time Stamp
Hi Experts,
PI should pick the Files from FTP location based on the File create time (This is not a time stamp on file name but a windows(OS) generated one). Is it possible in SAP PI?
Regards,
AniruddhaHi,
This is possible in NFS protocal Processing Sequenc By Date
● Processing Sequence (for transport protocol File System (NFS))
If you used placeholders when specifying the file name, define the processing sequence of the files:
○ By Name: Files are processed alphabetically by file name.
○ By Date: Files are processed according to their time stamp in the file system, starting with the oldest file
(http://help.sap.com/saphelp_nw04/helpdata/en/e3/94007075cae04f930cc4c034e411e1/content.htm)
Regards,
Naveen. -
DataSource has to be replicated (time stamp, see long text)
Hi Experts,
in Production i am getting an error like below
DataSource has to be replicated (time stamp, see long text)
@5C@ Errors in source system @35@
Message no. R3016
Diagnosis
DataSource 8ZCRFAC03 does not have the same status as the source system in the Business Information Warehouse.
The time stamp in the source system is 19.04.2011 12:56:44.
The time stamp in the BW system is 19.04.2011 12:29:02.
System Response
The load process has been terminated.
Procedure
Copy the DataSource again and then activate the transfer rules that belong to it. You have to activate the transfer rules in every case, even if they are still active after the DataSource has been copied.
i replicated data source and activated transfer rules giving source system and infosource but still it is failing with same message
what went wrong not able to understand
Please help,
Thanks in Advance
NityaSeems to be an incorrect transport sequence:
1. First transport you DS from source system R/3 QA to R/3 Prd
2. Once it is successfully transported to R/3 PRD, Replicate DS in BI PRD
4. Now try to collect your infosource, DS, TR in transport request & try to transport it from BI QA to BI PRD.
5. Once it is successfully replicated in Production try Running the loads
It should work.
Regards
Raj -
What logs are effected by "Ignore Time Stamp in Client Messages " rule?
Hello,
We're considering whether we can set "Ignore Time Stamp in Client Messages" system rule to false.
Now we're implementing 2 functionality and use them at the same time.
One is to change equipment status immediately and log the record to RESOURCE_TIME_LOG table.
The other is to log equipment status change reason code. That's recorded into PRODUCTION_COMMENT table.
We already find "Ignore Time Stamp in Client Messages" system rule. It's explained in HELP site like following and plan to set it to false.
=====
true: Ignores time stamps from the client during validations for starts, completes, nonconformances, and parametric data. Use this rule in cases such as when the client clock does not match the rest of the system (the client clock is "out of synch").
false (default): Uses time stamps during validations
Can override at: site, resource
=======
However, we're a little confused becasue above help says the default value is false and the default value in our customer's ME is true. When we try with the rule as true, these time stamps are sometimes different. (I guess the reason, these tables can't handle smaller time than 1 second.)
Which ME tables will be effected if we set "Ignore Time Stamp in Client Messages" to false?
As I mentioned, we'd like to set equal time stamp into There're RESOURCE_TIME_LOG and PRODUCTION_COMMENT.
In the other hand, we concern the rule may make bad effect with other functionality and/or tables (e.g. PRODUCTION_LOG, ACTIVITY_LOG , and so on).
Best Regards,
Takahiro UesugiTakahiro,
From the beginning the system rule was introduced with default value of Fasle which was described in the online help. However, later the customers started using XML Production Interface more intensively which caused the problem of data inconsistency due to abuse of timestamp fields and sending messages with delays and not in chronological order. The solution in that case was to switch the rule on. And sicne that time the default value has been changed to True.
So, the system rule should control timestamp fields of XML Production requests where the actual time of activity execution is specified
Regards,
Sergiy. -
DataSource 8ABCD_K01 has to be replicated (time stamp, see long text)
Hi,
We copied SCM production system to SCM quality system and after that I tried to run forecast process chain.
I got the following error message when process chain tried to extract sales history and failed:
DataSource 8ABCD_K01 has to be replicated (time stamp, see long text)
Message no. R3016
Diagnosis
DataSource 8ABCD_K01 does not have the same status as the source system in the Business Information Warehouse.
The time stamp in the source system is 19.12.2008 23:55:19.
The time stamp in the BW system is 01.07.2008 01:51:43.
System Response
The load process has been terminated.
Procedure
Copy the DataSource again and then activate the transfer rules that belong to it. You have to activate the transfer rules in every case, even if they are still active after the DataSource has been copied.
Errors in source system
Message no. RSM340
I never did this activity (data source replication)before.I'll appreciate if somebody can help me and provide step by step process to how to do it?
Thanks
KumarThanks for prompt respons Julien.
STEP1:
In SCM quality system, I went in RSA1-- > Infoprovider-> Data source->Right click there --->replicate metadata
got popup message :
Message no. TK730
Diagnosis
In this logon client, any changes to the Repository and to cross-client Customizing objects are prohibited.
System Response
The function terminates
Procedure
If you still want to make the changes, contact the system administrator, who can allocate you a user in a client where you can make the changes.
STEP2:
When I ran the program RS_TRANSTRU_ACTIVATE_ALL ,
entered source system : BW....CLNT...
Infosource : 8ABCD_K01
got following log :
No Transfer Structure Selected
Message no. RSAR051
Do I need to do run data source replication process in SCM developement and then trasport to quality? Is there any pre/post requisite or step i missed.
Thanks -
Hi Experts,
I have a process chain which extracts the master data and it failed yesterday mentioning the below mentioned bug
DataSource 0PERSON_ATTR does not have the same status as the source system in the Business Information Warehouse.
The time stamp in the source system is 28.06.2011 07:01:14.
The time stamp in the BW system is 21.09.2010 13:24:08.
System Response
The load process has been terminated.
Procedure
Copy the DataSource again and then activate the transfer rules that belong to it. You have to activate the transfer rules in every case, even if they are still active after the DataSource has been copied.
I replicated the Data source but i cannot activate the transfer rules as i am in production.
please let me know the procedure i can do to fix this bug
regards
Krishna Mohan.Hi Mr.Aravin,
Thanks for your valuable help.
it solved my problem instantly.
i did the following
Went to SE38
used the program RS_TRANSTRU_ACTIVATE_ALL
executed the same
and in the next screen
i typed in the source system name in the source system coloumn
and in the infosource coloumn i typed in the name of the infoobject
and executed the same
and it did the task what i needed.
thanks once again and full marks awarded.
regards
Krishna Mohan -
Can I enter a different time stamp in Citadel?
While logging data in a citadel database is it possible to log time stamp other than the system time ?
- Memory Tags will get the timestamp from the local acting DSC Engine's computer.
- I/O Tags get the timestamp from the I/O server when the timestamp is provided. This could be for example a VI-based Server that provides special timestamp for certain items.
- OPC server: Normally the OPC server provides the timestamp and LabVIEW DSC's OPC client just passes through the timestamp to be logged into Citadel.
Conclusion: If you just use regular tags, you cannot provide a timestamp with the value to be logged. You have to write your own (VI-based) server with its timestamps.
LabVIEW DSC comes with some VI-based server examples and a .pdf manual for VI-based Server development. That's maybe a good starting point.
Hope this helps
Roland -
System Time Stamp Indicator?
I'm trying to use the "System" theme for my front panel, and my controls and simple numeric indicators converted over (from "Modern"). However, I noticed that there is no simple "Time Stamp Indicator" apparent on the System > Numeric (or elsewhere).
Is there one that I just can't find? Or will I have to hard-code it in so that it displays using the system theme?
Thanks
Solved!
Go to Solution.The most trivial one would be to just use a double floating point control and set its format to absolute timestamp. Then convert the timestamp type to DBL with the according conversion function.
If you really want to go the route of a true system type control you will have to go into the control editor, which is a somewhat irky and tedious editor that shows its age from early LabVIEW days. There you would start with a classic timestamp control and replace the cosmetics with ones from a system string or similar control. It takes quite a bit of time to get to know the control editor and work around its murky behaviour sometimes.
Rolf Kalbermatter
CIT Engineering Netherlands
a division of Test & Measurement Solutions
Attachments:
System Timestamp.ctl 5 KB -
Bizzare system time vs. time stamp behavior after world travel ---HELP!
This is totally annoying.
I travel. When I am in other countries on business I change the time zone on my PowerBook in the System Preferences utility. When I got home from Singapore this last trip, I changed the clock back to the Los Angeles time zone. The clock in the upper right hand portion of my desktop reads the correct Los Angeles time, as does the time zone in System Preferences.
Now, when I create or modify a file on my computer, the time stamp APPEARS in the OS X GUI to be in Singapore time. However, I discovered tonight that when I create a file in the Unix terminal that the time stamp in the terminal is the correct Los Angeles time.
You can see for yourself:
http://math.ucr.edu/~legolas/clock.jpg
What the heck gives? This is exceedingly annoying.
Please Advise,
Bryce
PowerBook 12" Mac OS X (10.3.9)Hi Bryce,
maybe this is just another example of the Finder being a bit "slow". Your terminal output shows the right time stamp and that I would trust. Maybe restarting the Finder will force it to refresh. If that does not work try to restart the machine.
-Petra -
When I send emails w/Firefox (AOL) they are time stamped i hour earlier than my PC's system clock. My system is set to Eastern Time Zone
The cache is mentioned several times in the report.
Go to ~/Library/Caches/com.apple.systempreferences
Move the Cache.db file from the com.apple.systempreferences folder to the Trash.
Restar your Mac.
~ (Tilde) character represents the Home folder.
For Lion: To find the Home folder in OS X Lion, open the Finder, hold the Option key, and choose Go > Library -
Hi all,
i am working on a scenario...
it is file based..no mapping and bpm can be used.
I need to pick up file through xi and append it and put in the target with time stamp to it.
we can achieve this if mapping or bpm is allowed.....
But,in file processing we can use only one option at a time.....
I found a way:
scenario one: files will be appened and kept in a temparory folder
using another scenario we will pick up the appeneded file and add time stamp and keep in target structure...
but i dont think this is advisable...
please suggest me any other ways to achieve this...(can run operating system command be helpfull??)
thanks in advance..
Regards,
Kiran.HI,
Yes you are right, Appending and adding Time Stamp will not be possible simultaneously.
Refer - this could help you
Dynamic Filename with TimeStamp
Dynamic Filename with TimeStamp
/people/william.li/blog/2006/04/18/dynamic-configuration-of-some-communication-channel-parameters-using-message-mapping
But some how you have to use mapping for it. Then if its allowed to use the mapping then as you have suggested, should have to go for two scenarios. No alternative,
Probably also you can try with Customized Adapter Module for this.
Thanks
swarup
Maybe you are looking for
-
I had updated Firefox after it kept popping up to do so, but in the process my Skype extension is now disabled and it says that Firefox can't find one that is compatible and I need to have my Skpe on here. Is there a way I can go back to the older ve
-
Query in Insert statement with JDBC Rx adapter
Hi, This is a FILE to JDBC scenario. My target datatype is like this with sample payload values statement_s statement_s action='INSERT" access A=1234 B=1002 key A=1234 B ="10%" compareOperation= LIKE A(1..1) is primary key in
-
Can't create new user, Permission Errors in Console
I just purchased a new 2013 iMac with a 3TB Fusion Drive. I'm trying to dig and fing out why I'm currently unable to create and log in to another user account. I haven't manually changed any permissions in the terminal, and I've booted into recovery
-
Use a keywords list as a source for an autocomplete list?
Is this possible? I have a large keyword list that has been developed over a long period of time. I want to be able to autocomplete when I start typing, based on the keywords list. The list has become very difficult to quickly navigate in the keyword
-
Hi, Has anyone come accross this before. I've transfered some music files onto my phone, When i try to play certain tracks, it won't play them & will skip to the next track it can play even though the file is successfully transmitted to the handset.