Tpi Net compatible with LabVIEW 7.0 ?

Hi,
I designed drivers with LabVIEW 7.1 FDS for a remote instrument using the TpiNet library and the .NET Framework v1.1.
The operation was quite good.
After translating the same VI's to LabVIEW 7.0 PDS in order to provide executable applications to my customer, I couldn't run any of my programs.
After connection to the instrument, Labview 7.0 PDS sends the following error message :
"Error 1055 ... Invalid object reference"
the class which obviously fails under Labview 7.0 PDS is Connect in Tektronix.LogicAnalyser.TpiNet.ITlaSystem ;
Could anybody confirm this incompatibility between TpiNet and LabVIEW 7.0 ?
or propose any solution ?
thanks ;-)

I advise you to contact tektronix to know the compatibility with Labview 7.0.
Regards

Similar Messages

  • In need of a KEITHLEY 2001 single read .vi that is compatible with LabVIEW 7

    I am updating from LabVIEW 5.1.1 to 7. The KEITHLEY 2001 Single Read .vi has coercion errors, and does not function. Where can I get updated KEITHLEY 2001 .vi's that are compatible with LabVIEW 7?

    You can visit http://ni.com/idnet/, click the "Search Drivers" button
    and select "Keithley" as the manufacturer and hit the "Go" button.
    Look down the list, and you'll find the LabVIEW Certified Plug and
    Play driver for this multimeter scanner.
    I hope this helps.
    Brian

  • Are USB-6008 drivers available that make it compatible with LabVIEW 6.1?

    I'm using a USB-6008 Multifunction DAQ, but it is not compatable with teh version of LabVIEW I'm using, 6.1. I may be able to upgrade to LabVIEW 7.1 to solve the problem, but I wanted to know what alternatives I have. Are there any available drivers or patches that allow the USB-6008 to be recognized by LabVIEW 6.1?

    Unfortunately, no. The driver for the USB-6008, DAQmx Base 1.5 is only compatible with LabVIEW 7.0 or newer.
    -Alan A.

  • Is the Keithley 2612A compatible with Labview 7.1?

    Hi,
    I've got a shiny new Keithley 2612A dual channel sourcemeter and would like to start using it our lab's system.  We are currently using LabView 7.1.
    I found a driver for the 2612A, but it says it's only compatible with LabView 8 or higher:
    http://www.keithley.com/base_download?dassetid=51950
    Does anyone know of another driver, or other method that I might get this thing working in LabView 7.1?
    Many thanks,
    John
    Solved!
    Go to Solution.

    Download it and post it to the Downconvert thread.
    edit - It's a project style driver which was introduced with LabVIEW 8. It might take a little longer.

  • I need a step motor and controller compatible with LabView Can you recommend any

    I need a step motor compatible with LabView and I thought i would check with you before i moved forward in my experiment

    Dear chapbs,
    I've attached a sample cart below to show you the components for a possible setup of your system. Keep in mind that whatever stepper drive you purchased would power your motor. If you go ahead with the purchase of a controller & drive, I would highly recommend contacting NI to insure that you purchased the correct accessory components and cables to connect & power the components. I hope the  sample cart is helpful. I created it  by browsing ni.com, adding items to my cart, and then saving the cart to an excel file. Please post back if you have additional questions.
    Best Regards,
    ~NH
    Attachments:
    SampleCart.pdf ‏145 KB

  • Does MATLAB rel.13 compatible with LabView v.6.1

    I've met a problem with MATLAB script calling after upgrading to from MATLAB rel.12 to rel.13. Does MATLAB rel.13 compatible with LabView v.6.1?

    Thanks a lot!
    It helps.
    "Matt K." wrote in message
    news:[email protected]..
    > Check out this post:
    >
    http://exchange.ni.com/servlet/ProcessRequest?RHIVEID=101&RPAGEID=135&HOID=5
    06500000008000000EB5E0000&UCATEGORY_0=_49_%24_6_&UCATEGORY_S=0

  • Is IMAQ 2.6 fully compatible with Labview 6i?

    Hello...does anybody knows if NI IMAQ is fully compatible with ALbview 6i?
    What i´m trying to do is to convert a bmp or jpg image to a 2d array..i can do this with the vi ColorImageToArray but how can i get an array for each color plane without using IMAQ Vision module?
    Is there a way to convert the 2D 32 bits array that gives the ColorImageToArray into three different color planes or arrays?..is it possible to do this without Vision?
    thanks
    thanks

    Hello,
    NI-IMAQ version 2.6 is fully compatible with LabVIEW 6.x. NI-IMAQ driver is an image acquisition driver and it has all the functionality required for acquiring images from an external video source through National Instruments frame grabbers.
    In order to do image processing, such as performing operations on saved images from the hard drive, you will need IMAQ Vision image processing libraries.
    Hope this helps!
    Best regards,
    Yusuf C.
    Applications Engineering
    National Instruments

  • When IMAQ vision that is compatible with labview 8.0 is going to be released?

    Hi, i got labview 8.0 but it is not compatible with imaq vision 7.x series. I am wondering when the new version of IMAQ vision that will be compatible with labview 8.0 is going to be released.
    Thank you,
    Christos

    Hey Matt,
    There is also a great knowledgebase document called How do I install my IMAQ software/drivers with LabVIEW 8?, which has an update on it that takes care of moving everything that you need to move in order to get Vision 7.x.x to work with LabVIEW 8.0. Of course nothing extra has to be done with the IMAQ Vision 8.0 software to work with LabVIEW 8.0. One more thing, similarily to LabVIEW 8.0, you can now download the Vision Development Module Version 8.0 software from NI's website in case you wanted to try out (30-day trial) the Vision 8.0 software before upgrading.
    I hope this helps. Have a great day.
    Regards,
    DJ L.

  • Is Max 4.1 compatible with Labview 7.0?

    I see that Max 4.1 comes with daqmx 8.3 which is NOT listed as Labview 7.0 compatible.  I also see that installing the last daqmx for labview 7.0 (ie daqmx 8.1) would install max 4.0.3.  Therefore, if i have max 4.1 installed with labview 7.0/daqmx8.1 am I expected to have issues?

    degenste,
    Just to clarify a bit, Measurement and Automation Explorer (MAX) displays a list of NI devices and software on your computer, but it does not install support for those devices.  The DAQmx driver is responsible for installing support for our Data Acquisition products.  Support for USB M-Series devices was not added until version 8.3 of DAQmx.  This knowledge base article describes why the USB M-Series product line has to be used with DAQmx 8.3.   
    You are correct when saying that DAQmx 8.3 is not compatible with LabVIEW 7.0 as stated in this document.  With this set up, your only options would be to upgrade your LabVIEW version or choose a different form factor such as PCI for your device.
    Regards,
    Ryan N
    National Instruments
    Application Engineer
    Ryan N
    National Instruments
    Application Engineer
    ni.com/support

  • Is cRIO-9073 compatible with LabVIEW 8.5.1?

    I just received a cRIO-9073 and a cRIO-9074.
    When I configure them, both of them appear properly in MAX.
    When I add them to a LabVIEW project, the cRIO-9073 does not show its FPGA target. The cRIO-9074 does show it.
    I am using LabVIEW 8.5.1, is it compatible with the cRIO-9073?
    Thanks for any help.
    Michel
    Solved!
    Go to Solution.

    Hi Oswald,
    Thank you very much for the very prompt response. This should solve my problem.
    Also, after I read you message, I finally found the link to the software revision/compatibility file in the CompactRIO cRIO-9072/3/4 Operating Instructions and Specifications on page 3:
     "Notes Visit ni.com/info and enter the info code rdsoftwareversion to determine which software you need to use the cRIO-9072/3/4."
    Thanks again for your help
    Michel Lanthier

  • Is the Intel I340-T4 Ethernet card compatible with LabView 8.6?

    We are currently looking in to having our LabView program process the output of two Allied Vision cameras, run through a PCI GigE card.
    On our old machine (32-bit Vista), we have a PRO/1000 PT Quad working just fine with the LabView interface - and we want to upgrade to a better PC with 64-bit Win 7.
    We are under the impression that PRO/1000 PT is not compatible with Win 7, and were looking into either I340 quad-port adapters:
    http://ark.intel.com/products/49186/Intel-Ethernet-Server-Adapter-I340-T4
    Does anyone have any insight as to the compatibilities of the Intel 82580 controllers with LabView 8.6? 

    Hi Civa,
    Scott here from AVT technical support.   You are correct re. that PT card not being Win7 compatible.  Here's a link to our current recommendations for NICs and switches.
    http://www.alliedvisiontec.com/fileadmin/content/PDF/Support/Application_Notes/Hardware_Selection_fo...
    If it's NOT in that list, it doesn't mean it won't work, merely that we haven't tested it and do not know.  We do not attempt to test every 3rd party product on the market.
    And our testing is typical with AVT SDKs not with Labview, though there are thousands of joint AVT / NI customers, and we'd have heard by now if there were any conflicts, I am confident.
    Regards,
    Scott

  • Is the cRIO 9067 compatible with LabVIEW 2013?

    I just purchased 2 cRIO 9067s and I'm trying to configure one of them to use.  I got the IP address set and booted it into safe mode.  The status light blinks twice, then pauses.  The documention says this means I need to download software.  NI MAX only suggests using versions 14.?, which I'm assuming is LabVIEW 2014, but that option is grayed out.  And if I  try to do a custom install, everything in the list produces a concfict and wont download.  Is the 9067 only compatible with LV 2014?  Or am I missing a step?  the version of LV that I am using is 2013.  I'm installing 2014 to test this theory, but I'm no thopeful.  Thanks for the help people.  
    Solved!
    Go to Solution.

    The cRIO-9067 does require LabVIEW and NI-RIO 2014. You can use http://download.ni.com/pub/gdc/tut/crio_software_versions.htm to look up the minimum software support for cRIO products.
    I don't see how I can link directly to the result, but if you select "CompactRIO Chassis and Controllers" from the drop down and then "cRIO-9067" you should see this table.
    NI cRIO-9067
    Minimum Software Support
    Software
    CompactRIO (FPGA Interface)
    CompactRIO (Scan Interface)
    ✔ Supported
    ✔ Supported
    LabVIEW
    2014
    2014
    LabVIEW FPGA Module
    2014
    LabVIEW Real-Time Module
    2014
    2014
    Device Driver Software
    NI-RIO Device Drivers August 2014
    NI-RIO Device Drivers August 2014
    NI-DAQmx
    Other Minimum Software

  • Is NI-DAQ 7.1 compatible with LabVIEW 6.0?

    Hi, I'm trying to come up with a way to control relay switch in SCXI-1161 using NI-Switch function with LabVIEW 6.0. NI-Switch doesn't come with LabVIEW 6.0, so I have to download NI-DAQ 7.1 (which includes NI-SWITCH) to run with LabVIEW, but I heard that it could mess up the program because NI-SWITCH is built for higher versions of LabVIEW. First of all, are LabVIEW 6.0 and NI-Switch compatible? Also, is there an easier way to control SCXI-1161 relay modules with a simpler .vi that I can just download? Thank you.

    1) If you have LV 6.0 and if you have NI-DAQ (any version) you should have an example in \Program Files\National Instruments\LabVIEW 6\examples\daq\scxi\scxi1161.llb called SCXI-1161 digital Output.vi. This example controls the SCXI-1161 like a digital output module.
    2) If you want to use NI-SWITCH you can download NI-SWTICH 1.6 from: http://digital.ni.com/softlib.nsf/webcategories/85256410006C055586256BBB002C0C92?opendocument&node=132070_US
    YOu will get examples that shows you how to control relays on any NI switch modules using relay names or channle names.
    NI-SWITCH 2.0 or 2.1 comes with NIDAQ 7.0 or 7.1 but will not install any support files for LV 6.0 it only supports LV 6.1 and later.
    If you want to use LV 6.0 you will need to use NI-SWITCH 1.6 API or
    NI-DAQ API as stated in 1)

  • Is NI-DAQ 6.9.3 compatible with Labview 7.0

    I have an old lab-pc+ daq board that I want to use. So I downloaded ni-daq 6.9.3 driver because ni-daq 7.0 does not support the lab-pc+. I had previously downloaded labview 7.0. I was wondering whether I have to download labview 6.1 instead to be compatible with ni-daq 6.9.3 ( as it came with an additional file to make it run on Labview 6.1) or whether Labview 7.0 will be ok.
    Thanks,

    Alesya,
    You can use NI-DAQ 6.9.3 with LabVIEW 7.0. You will need to download the NI-DAQ 6.9.3 support for LabVIEW 6.1. During the installation of NI-DAQ 6.9.3, you should include support for LabVIEW 6.1 and change the installation location of this support to the LabVIEW 7.0 folder on your computer. If you follow this procedure, you should be able to use your Lab-PC+ with LabVIEW 7.0.
    Good luck with your application.
    Spencer S.

  • Are there any PCIE CAN Cards Compatible with Labview RT?

    Hi,
    I am looking for a mini PCIE CAN card or PCIE 1X CAN card that will run under Labview RT.  Are any of you using a PCIEC AN card with Labview RT?
    Thanks,
    Phillip

    Hello Phillip,
    I do not believe that we have any PCIe CAN cards. Here is a link to the PCI CAN cards that will work on LabVIEW Real Time(http://sine.ni.com/np/app/main/p/bot/no/ap/icomm/lang/en/pg/1/sn/n24CI,n21:17,n17:icomm,n19:Real%20T...). Please let me know if you have anymore questions. Have a great day!
    Best Regards,
    Adam G 
    National Instruments
    Applications Engineer

Maybe you are looking for

  • Add attachment to services for object

    Hi All, What is the meaning of Add Attachment to services for object, is it the only providing the services like Private note, send object with note, Display relation ship, work flow, My objects etc. can any one suggest me on this. Thanks&regds, Srin

  • Rounding a decimal value to 3 digits

    I have opened a UDF and copied the value of Total (LC) column in that field. I want to round off the copied value to 2 digits. Below is the query written to copy the value. SELECT ($[$38.21.NUMBER] * $[$38.U_GST.1.11]) / 100 Below is the query writte

  • Help needed to understand JLS �15.14

    Can someone please help me to understand JLS �15.14 (http://java.sun.com/docs/books/jls/third_edition/html/expressions.html#15.14), it says: Postfix expressions include uses of the postfix ++ and -- operators. Also, as discussed in �15.8, names are n

  • Shade every 10 rows in a table

    Im using DW CS3. Basically I have a large table of 300+ rows. Because the rows contain  data with a row number in each row (ranking, first column), the table  would be easier to read if every 10 rows were shaded. 1-10, 21-30,  41-50, and so on. Id li

  • PreferenceSyncClient eating RAM and taking minutes to run

    Every hour on the hour, PreferenceSyncClient proceeds to take up 1+ GB of RAM (out of 4) while bringing my machine to a near standstill. I must force quit it in order to get in work done in the next 10 minutes. I am not a .Mac subscriber. I've looked