Hello PM experts
I came across the SAP note 336644;
Scenario: When you include a general maintenance task list  ,you want to transfer  the work centre from the header of a maintenance order to the operations.However the system uses the work centre from the operations of the general tak list as  a default. The fix is only applicable up to 4.6c and we are running ECC6 ehp5. Does anyone know if this function was implemented with the later versions of SAP.

Andrew,
Try the IWO1_TL_INTEGRATION2 BADI option.
PeteA

Similar Messages

  • PM Order - Change "Work Center" on operations to "Main Work Center"

    Hi Experts,
    We have prepared a tool for client, which create Maintenance Plan and order in the background.
    The order created is having "Main Work Center" defined at header and "Work Center" at the operations level. In the current scenario the "Main Work Center" and "Work Center" are different say 'ABC' & u2018XYZu2019.
    Client has the requirement that work center maintained at operations should be same as the main work center.
    We need to implement the solution to take care of work center to be same as main work center while creation of the order in the background.
    Has anyone worked on the similar requirement before?
    I checked for existing USER EXITS for IW31/32/33 and found only one IWO10012. This doesnu2019t seem to be much useful.
    Please suggest any possible solution.
    Thanks,
    Ankur Sharma

    Hi Tilak,
    Thanks for the response. The current situation is that we are creating the order in background using the Z-program. The scenario is creating order with operation entries having work center not equal to the main work center.
    I am not functional, so just talking in terms of technical terms.
    Is there a way the work center at operation level can be changed to main work center in background?
    Thanks,
    Ankur Sharma

  • Tables for Basic end date and work center for operation

    Hi!
    I need table name to fetch the basic end date of a maintenance order and maintenance work centers with respect to each operation in maintenance order.
    Regards,
    VM
    Edited by: V M on Jul 20, 2010 7:22 AM
    Edited by: V M on Jul 20, 2010 7:35 AM

    Hi VM,
    Input is Order Number (AUFNR).
    You can find the Basic End date of Order in Table AFKO, filed is GLTRP.
    For work center in Operations, you can use the Table AUFPL from AFKO.
    Pass this AUFPL in AFVC and get the ARBID.
    Then pass this ARBID to CRHD Table as OBJID, and get the work Center (ARBPL)
    Regards,
    MLN Prasad

  • Work center wise operation consumable

    my requirement is  operation consumables issuing from storage loction to the work center
    i want  report what are consumables isued to the work center

    Hi,
    In standard SAP,
    a. we have the transfer posting from the Storage location to the Storage location only
    b. Issues ( Stock reductoin or consumption ) can be done to order/Cost center etc only.
    c. Material cannot be issued to the workcenter.
    Note: Generally operation consumables if ther are bulk and less value you can directly issue to the cost centre
    Reg
    Dsk

  • Add Work center to operation's network

    Hi,
    I need to add a WORK CENTER KEY to a operation (inside a network).
    I have to prove with FM: CO2O_ACTIVITY_MAINTAIN, but... nothing
    can anyone help me, please??
    best regards!

    The reason for turning off WEP was to confirm it is a WEP issue, you should turn it back on.
    One of the problems with WEP is that the actual standard relies on a 10 character HEX key for 40bit WEP and a 26 character HEX key for 128bit WEP.
    In order to make things easier for people, vendors use certain algorithms to convert simple alphanumeric passwords (or passphrases) into HEX keys, thus enabling people to use simple memorable WEP password rather than lengthy HEX keys.
    The problem is that different vendors use different algorithms to generate the HEX key and therefore a ASCII password on an AEBS will be hashed differently on a Netgear client and vice versa.
    One thing is a 13 character 128 bit WEP password will be hashed by all vendors in the same way (if you use 40bit WEP then a 5 character password is required).
    Having said that, this will only work if they use an algorithm, some don't and in these cases you must use the HEX key regardless of the length of the plain text password.
    AirPort: Joining an encrypted wireless network
    http://docs.info.apple.com/article.html?artnum=106424
    Choosing a password for networks that use Wired Equivalent Privacy (WEP)
    http://docs.info.apple.com/article.html?artnum=108058
    Accessing a Airport Network with a Windows XP PC or laptop (with XP SP2)
    http://www.ifelix.co.uk/tech/1011.html
    Accessing a Airport Network with a Windows XP PC or laptop (with XP SP1)
    http://www.ifelix.co.uk/tech/1010.html
    Also confirm that you are not using MAC Address access control.

  • Operations Executed at a Particular Work Center for a Sales Order

    Hi All,
    We are using a MTO scenario. I have to get a report in which I have to list work center wise operations (and the corresponding material) which are carried out for a particular sales order.
    User will create a sales order, and then do Sales Order based MRP in MD50. System will do a BOM explosion for the header material and will generate planned orders for the production relevant materials. User will then convert all these sales order specific planned orders to production orders. For a particular sales order these would be many operations (at different BOM levels may be ) that would be carried out at a particular work center. I need to get a logic for generating this report. Is there any FM etc or table table-field fetchig logic....
    Regards

    hi,
    maintain initial screen entry as sale order.
    Pass values to AFPO table. Identify all AFPO-AUFNR values which satisfies AFPO-DAUTY = 10
    Transfer AUFNR values to AFKO and check AUFPL (Routing number of operations in the order)
    Transfer AUFPL  to AFVC and check the value of AFVC-ARBID (Object ID of the resource)
    Transfer ARBID to CRHD and check value of ARBPL (Work Center)
    Regards,
    Pavan

  • Work center's description copy automatically in operation Routing

    Hi all,
    Could anyboy tell me where point of spro is to customize that work center's description is copied automatically in the operation Routing's description?
    I try to search for it but I don't find it still.
    Thanks in advance

    Hi,
    A suggestion:
    In CA10, create a key say Z1 & give the description same as work center's description.
    Now go to CR02 & for the work center in default values tab, assign the key to the field Standard Text key.
    Now when you create a routing which uses this work center, the operation description will contain the work center description.
    Regards,
    Vivek

  • How to change the main work center and  work center of each operation when generating work order by maintenance plan

    Dear experts,
    I face a problem that system get main work center from equipment master data as a default main work center in maintenance plan when creating maintenance plan. however, if main work center in equipment is changed later, the change will not synchronize to related maintenance plan. if work order is generated from maintenance plan, main work order in order is defaulted from maintenance plan instead of updated work center in equipment.
    another problem is that, for those orders generated by maintenance plan, the work centers in  operations is defaulted from task list in maintenance plan. in most case, work center in task list is dummy. Actually the work is done by work center in equipment master data.
    My expectation is how to auto replace the main work center and work center of operations in work order with the one in equipment master data if order is generated by maintenance plan? is there any standard configuration or enhancement/BADi that can help with this requirement?
    thanks!
    Wesley

    Wesley,
    Sorry - development is the only way.
    Another option is to create a batch program that runs before your IP30 run(s) and updates any maintenance items and task lists with the correct work centres.
    PeteA

  • Work Center Analysis Monthwise

    Hi,
    In COOIS when we take list as operations it displays the various details like work center,PO, operation qty, yield, Standard time and confirmed avitity,actual finish date etc. We can take a report about all these details for which orders are confirmed.I have requirement where for each work center, monthwise report is required to display only the partial /confirmed production orders during that particular month. Is there any possibility to get report monthwise??.
    Thanks
    Ramagiri

    Rama,
    did u try with COOIS, itself.
    put work center ,system status( at operaion / order level), basic/ production dates( select one month span), and it will display only that work cneter specif prod orders with addtional selection criterial you applied.
    i am not sure if final output has all the information columns you need to see in work cneter monthly report.
    if something is missing in output columns, try enhancing the COOIS.

  • How to Assign Person (Personnel Number) without work Center

    Dear All,
    How to setup personnel number in order not using general and internal work center in operation service order area?
    if i use work center, it make HRD site and payroll will be damage
    please help me if you have any solution?
    Thanks
    Rendra Rizki

    dear all,
    When i tried to use co11n , the earning appearence :
    You want to confirm a network/order of the order type FEN1. However, this order type is allocated to an order category whose confirmation is not intended in this transaction.
    You try to confirm a network using a transaction intended for confirming production orders. Since networks and production orders are assigned to different order categories, the system issues an error message.
    so i still can't use this tcode, do you have any?
    Thx

  • PM Order - Change operations Work Center to Main Work Center

    Hi Experts,
    We have prepared a tool for client, which create Maintenance Plan and order in the background.
    The order created is having "Main Work Center" defined at header and "Work Center" at the operations level. In the current scenario the "Main Work Center" and "Work Center" are different say 'ABC' & u2018XYZu2019.
    Client has the requirement that work center maintained at operations should be same as the main work center.
    We need to implement the solution to take care of work center to be same as main work center while creation of the order in the background.
    Has anyone worked on the similar requirement before?
    I checked for existing USER EXITS for IW31/32/33 and found only one IWO10012. This doesnu2019t seem to be much useful.
    Please suggest any possible solution.
    Thanks,
    Ankur Sharma

    Hi,
         The work Center entered by default comes in operation work center, u can do validations while saving the Order :-using user exit : IWO10009 PM Order: Customer Check for 'Save' Event.
    regards
    pushpa

  • IW31,IW32 Exit / BAdI to update Oprtn's Work center based on Header WrkCtr

    SAP 46C
    I am looking for a way to ensure that the first operation on a Maintenance Order has the same work center as the Header of the Operation. I am not seeing a BAdI that has the export parameters that allows update of information. Infact I did not see one in ECC6 either.
    Thanks
    Hari

    Hi Dude,
    Code to find out the BADI or exit..
    REPORT  ZBADI_FINDING.
    TABLES : TSTC,
    TADIR,
    MODSAPT,
    MODACT,
    TRDIR,
    TFDIR,
    ENLFDIR,
    SXS_ATTRT ,
    TSTCT.
    DATA : JTAB LIKE TADIR OCCURS 0 WITH HEADER LINE.
    DATA : FIELD1(30).
    DATA : V_DEVCLASS LIKE TADIR-DEVCLASS.
    PARAMETERS : P_TCODE LIKE TSTC-TCODE,
    P_PGMNA LIKE TSTC-PGMNA .
    DATA WA_TADIR TYPE TADIR.
    START-OF-SELECTION.
    IF NOT P_TCODE IS INITIAL.
    SELECT SINGLE * FROM TSTC WHERE TCODE EQ P_TCODE.
    ELSEIF NOT P_PGMNA IS INITIAL.
    TSTC-PGMNA = P_PGMNA.
    ENDIF.
    IF SY-SUBRC EQ 0.
    SELECT SINGLE * FROM TADIR
    WHERE PGMID = 'R3TR'
    AND OBJECT = 'PROG'
    AND OBJ_NAME = TSTC-PGMNA.
    MOVE : TADIR-DEVCLASS TO V_DEVCLASS.
    IF SY-SUBRC NE 0.
    SELECT SINGLE * FROM TRDIR
    WHERE NAME = TSTC-PGMNA.
    IF TRDIR-SUBC EQ 'F'.
    SELECT SINGLE * FROM TFDIR
    WHERE PNAME = TSTC-PGMNA.
    SELECT SINGLE * FROM ENLFDIR
    WHERE FUNCNAME = TFDIR-FUNCNAME.
    SELECT SINGLE * FROM TADIR
    WHERE PGMID = 'R3TR'
    AND OBJECT = 'FUGR'
    AND OBJ_NAME EQ ENLFDIR-AREA.
    MOVE : TADIR-DEVCLASS TO V_DEVCLASS.
    ENDIF.
    ENDIF.
    SELECT * FROM TADIR INTO TABLE JTAB
    WHERE PGMID = 'R3TR'
    AND OBJECT IN ('SMOD', 'SXSD')
    AND DEVCLASS = V_DEVCLASS.
    SELECT SINGLE * FROM TSTCT
    WHERE SPRSL EQ SY-LANGU
    AND TCODE EQ P_TCODE.
    FORMAT COLOR COL_POSITIVE INTENSIFIED OFF.
    WRITE:/(19) 'Transaction Code - ',
    20(20) P_TCODE,
    45(50) TSTCT-TTEXT.
    SKIP.
    IF NOT JTAB[] IS INITIAL.
    WRITE:/(105) SY-ULINE.
    FORMAT COLOR COL_HEADING INTENSIFIED ON.
    *Sorting the internal Table
    SORT JTAB BY OBJECT.
    DATA : WF_TXT(60) TYPE C,
    WF_SMOD TYPE I ,
    WF_BADI TYPE I ,
    WF_OBJECT2(30) TYPE C.
    CLEAR : WF_SMOD, WF_BADI , WF_OBJECT2.
    *Get the total SMOD.
    LOOP AT JTAB INTO WA_TADIR.
    AT FIRST.
    FORMAT COLOR COL_HEADING INTENSIFIED ON.
    WRITE:/1 SY-VLINE,
    2 'Enhancement/ Business Add-in',
    41 SY-VLINE ,
    42 'Description',
    105 SY-VLINE.
    WRITE:/(105) SY-ULINE.
    ENDAT.
    CLEAR WF_TXT.
    AT NEW OBJECT.
    IF WA_TADIR-OBJECT = 'SMOD'.
    WF_OBJECT2 = 'Enhancement' .
    ELSEIF WA_TADIR-OBJECT = 'SXSD'.
    WF_OBJECT2 = ' Business Add-in'.
    ENDIF.
    FORMAT COLOR COL_GROUP INTENSIFIED ON.
    WRITE:/1 SY-VLINE,
    2 WF_OBJECT2,
    105 SY-VLINE.
    ENDAT.
    CASE WA_TADIR-OBJECT.
    WHEN 'SMOD'.
    WF_SMOD = WF_SMOD + 1.
    SELECT SINGLE MODTEXT INTO WF_TXT
    FROM MODSAPT
    WHERE SPRSL = SY-LANGU
    AND NAME = WA_TADIR-OBJ_NAME.
    FORMAT COLOR COL_NORMAL INTENSIFIED OFF.
    WHEN 'SXSD'.
    *For BADis
    WF_BADI = WF_BADI + 1 .
    SELECT SINGLE TEXT INTO WF_TXT
    FROM SXS_ATTRT
    WHERE SPRSL = SY-LANGU
    AND EXIT_NAME = WA_TADIR-OBJ_NAME.
    FORMAT COLOR COL_NORMAL INTENSIFIED ON.
    ENDCASE.
    WRITE:/1 SY-VLINE,
    2 WA_TADIR-OBJ_NAME HOTSPOT ON,
    41 SY-VLINE ,
    42 WF_TXT,
    105 SY-VLINE.
    AT END OF OBJECT.
    WRITE : /(105) SY-ULINE.
    ENDAT.
    ENDLOOP.
    WRITE:/(105) SY-ULINE.
    SKIP.
    FORMAT COLOR COL_TOTAL INTENSIFIED ON.
    WRITE:/ 'No.of Exits:' , WF_SMOD.
    WRITE:/ 'No.of BADis:' , WF_BADI.
    ELSE.
    FORMAT COLOR COL_NEGATIVE INTENSIFIED ON.
    WRITE:/(105) 'No userexits or BADis exist'.
    ENDIF.
    ELSE.
    FORMAT COLOR COL_NEGATIVE INTENSIFIED ON.
    WRITE:/(105) 'Transaction does not exist'.
    ENDIF.
    AT LINE-SELECTION.
    DATA : WF_OBJECT TYPE TADIR-OBJECT.
    CLEAR WF_OBJECT.
    GET CURSOR FIELD FIELD1.
    CHECK FIELD1(8) EQ 'WA_TADIR'.
    READ TABLE JTAB WITH KEY OBJ_NAME = SY-LISEL+1(20).
    MOVE JTAB-OBJECT TO WF_OBJECT.
    CASE WF_OBJECT.
    WHEN 'SMOD'.
    SET PARAMETER ID 'MON' FIELD SY-LISEL+1(10).
    CALL TRANSACTION 'SMOD' AND SKIP FIRST SCREEN.
    WHEN 'SXSD'.
    SET PARAMETER ID 'EXN' FIELD SY-LISEL+1(20).
    CALL TRANSACTION 'SE18' AND SKIP FIRST SCREEN.
    ENDCASE.
    DO 2 TIMES.
    ENDDO. 

  • Operation number and work center

    I'm looking for the link between inspection plan/recipe header and operation at table lavel.
    Reason: I have two inspection plan number with same group number but both has different counter and each has 4 operation and each operation has different work center.
    Now I can get header info in PLKO and operation level info in PLPO table. From PLKO I can pass PLNTY and PLNNR in PLPO table but this gives me 8 entry in PLPO table (4 for 1st group counter and 4 for 2nd counter).
    So my question is how to differentiate 4 operation of each inspection plan header. Even same issue facing at recipe level.
    I can't find any table. Do we have any BAPI?

    Detailing the above reply through SQVI.
    The Join.
    Selection Screen
    The output
    If you need you may have Header table (PLKO) also in the join to have more details.
    Jogeswara Rao K

  • More than one work center for one operation

    Hi Experts,
    Is it posssible to assign more than one work center to one operation,in a maintenance order?
    for example if head fitter and helper has executed maint.activity,how we can do this
    Thanks in advance
    Regards
    Prashil

    Dear,
    You cannot assign more then one workcenter to a one operation.
    But you can assign to a sub operation,i.e to operation one workcenter and to suboperation anotherworkcenter.
    For Sub-operation:
    Go to task list change >>> Operation tab.
    Let say your first operation number is 0010. Then below it for next operation change operation number to 0010 and next to it there is field for sub-operation give there number 0001 or 0010 as per your requirement. Select suitable control key and work center, give description and press enter. your sub operation 0001 will be created for operation 0010.
    I hope it will solve your query,
    Thanks,
    Mohit

  • What will happen if a maitain both standard available capacity and grouping key ( shift definition and shift sequence) in the capacity header of a work center?

    Hi all,
    Im little confused with the capacity header in work center. In the capacity header there is one place to give start time, end time, length of break and number of individual capacity. And in grouping key i can define the shift and shift sequence. So if im maintaining both of these ( standard avilable capacity and grouping key), which will be considered to calaculate avilable capacity?

    Hi
    If you are running three shifts ,please maintain the data as given belwo
    start :00:00:00
    End:23:59:59
    Break :03:00:00 ( 1 Hour per shift so 3 hrs for 3 shifts)
    No.of individual capacity :1
    System will understand that it is round the clock operation with total three hour brak and you will get 21 hour per capacity
    Hope this helps
    regards
    Prakash

Maybe you are looking for

  • EbXML Quality of Service Configuration

    Hi, Where can I find some good practice on the reliable messaging configuration for ebXML messages. I am looking for some recommanded values for Retry Count, Retry delay when OnceAndOnlyOnce QOS is configured. Thanks for any support. Regards, Hatim

  • How could i reset my password on my ipad 2 if it is not the same computer

    i cant remember my password and i'm not home where my computer is

  • Setup Central System Administratin and Setup System Monitoring grayed out

    When trying to setup Central Sytem Administration and System Monitoring via SOLUTION_MANAGER.>Operations Setup->Solution Monitoring->Setup Central System Administration (or Setup System Monitoring).  The link does not work.  However, Setup Earlywatch

  • Quality of still images imported from i-Photo

    I've recently got a new Mac, with updated version of i-Movie. Struggling to come to terms with it, but one major problem is quality of still images. Whatever I do, they look rubbish in i-Movie. I've tried all sorts of settings, Ken Burns etc, still n

  • Repeat delta - thanks

    Hello thanks for the threads,it really helped me a alot,and also thanks for SRS,but i was left with small confusion after after reading all, 1.is there any difeerence for repeat delta for Master data,transactional data and time stamps. 2.if there is