Transfer structure Transport ?

Hello Experts,
Transport from System1 to System2.
Transfer structure, data source, transfer rules, infosource are already present in the target system system2.
I made modifications to the transfer structure in system1 and added just the transfer structure to the transport request to system2. It failed with these messages. Highly appreciate your suggestions.
Error: "There is no Datasource with these attributes"
Warning: "Reference to transfer structure ABC_AB not available. No activation possible".
Wondering if I have to include the datasources in the transport request along with the modified transfer structure. 
Thanks,
Sweatha.

Hello Sweatha,
If you have made changes in the Transfer Structure and the transfer rules, I would advice you to transport the entire infosource to system2.
Hope it helps.
Ravin

Similar Messages

  • Transfer Structure - Transport Problem

    Hi Experts,
    I am transporting infosource from BW DEV to BW QA ( Datasource is transported and it is replicated) but when the request is imported in QA it gives me error saying " Transfer structure does not exist " . This Infosource is used for Remote Cube .
    Could anyone help me in this as in QA I see Infosource in Deactivated state even though remote cube( based on this Infosource) is active .
    Regards,
    Vijay.

    hi Vijay,
    seems transfer structure not collected, maybe source system not choose/assigned. try in bw dev, with infosource selected for transport, choose grouping 'in dataflow before' and collection mode 'manual', click 'source system assignment' and make sure your source system is marked. then execute to collect objects. after finished, expand the infosource, and make sure there is transfer structure and marked. then create transport request, stms and transport again. hope this helps.

  • Error in Transporting the Transfer structure

    Hi can any body tell me . Iam getting this error  while transporting from BW System the transfer structure for 0HR_PY_1_CE.
      1. Transfer structure 0HR_PY_1_CE_LA does not exist.
      2. Error RSAR 440 during after import handling of objects with type(s) ISTS
      3. Errors occurred during post-handling RS_AFTER_IMPORT for ISCS L
    I have  activated the transfer structure  through this programme - program RS_TRANSTRU_ACTIVATE_ALL.

    Check the below notes:
    Note 1009638 - RSAR 440 when you activate transfer rules    applicable for BI7.0 Less than SP12.
    Note 736668 - RSAR 440: Transfer structure & does not exist   Applicable for 3.x system.
    Please check the above Notes and based on your system patch level and issue you need to choose the right one. Second one deals with the Hierarchy.
    Hope this helps..
    Murali

  • Copy transfer structure transfer rules from one client to other client

    Hi
    Our R3 client 100 is mapped to BW client 100.
    R3 client 100 is source system in BW.
    As the master data is created by users in R3 client 200 we want to get the data from client 200 to BW. We dont want to replicate each datasource and do all stuff form scratch for client 200.
    Now the question is as we need to create transfer rules, transfer structure for all master data objects for client 200 in BW.
    1. Going to create R3 200 client in BW.--this is possible.
    2.Like create a transport connection in BW for client 200 for all master data infoobjects transfer rules transfer structure,process chain, infopackages..etc
    3.Do the source system mapping for new client 200.
    4.and then execute the process chain..
    What are the best ways to achieve this.
    creating all transfer structure and transfer rules only for those we are loading daily ..rather than all active ones.. How can I get the list of that master data that is loading daily.. and how easily can I create transfer structure..etc dependent objects in one go than manually.
    Any help or thoughts are appreciated..
    can anyone throw some light please....

    Hi,
    BW is not client dependent!!! When you sign on to BW, you have the client required. However, this field does not appear in any table (master data, ODS, cubes, whatever).
    This means that a same BW server with a single client can have multiple R/3 connections (for multiple R/3 clients).
    The database do not care about the client in BW. The data will be consolidated.
    So, you do not need any new client in BW, just two R/3 connections for your two clients.
    Regards,

  • Transfer structure copied into another structure ?

    Hello ,
    Iam trying to transport an transfer structure and iam getting an error and when i looked into the SE09 log i noticed somethng strange .
    I am not understanding why a transfer structure is copied into another structure as shown below in Bold  while transporting ??? is this somethng normal or somehtng happening strangely in my system ?
    "   Start of the after-import method RS_ISTS_AFTER_IMPORT for object type(s) ISTS (Activation Mode)
      <b>Transfer structure 80MATERIALM_CB activated under the name 80MATERIALM_CA</b>
      It is not necessary to copy dependent objects for transfer structure 80MATERIALM_CA
      <b>Object 80MATERIALM object version   not found in table</b>
      Activating Transfer Rules 80MATERIALM_CA ...
      3 Transfer Rule(s) of the transfer structure 80MATERIALM_CA removed from control table
      3 InfoObject(s) of the transfer structure 80MATERIALM_CA removed from control table
      Formulas have been saved
      Saving Structure /BIC/CACA80MATERIALM ...
      Activating Structure /BIC/CACA80MATERIALM ...
      Saving Structure /BIC/CCCA80MATERIALM ...
      Activating Structure /BIC/CCCA80MATERIALM ...
      Saving Structure /BIC/B0000015000 ...
      Activating Structure /BIC/B0000015000 ...
    <b> Object 80MATERIALM object version   not found in table</b>
      Start of the after-import method RS_ISTS_AFTER_IMPORT for object type(s) ISTS (Delete Mode)
      Start of the after-import method RS_ISMP_AFTER_IMPORT for object type(s) ISMP (Delete Mode)
      Start of the after-import method RS_ISFS_AFTER_IMPORT for object type(s) ISFS (Delete Mode)
      Start of the after-import method RS_ROUT_AFTER_IMPORT for object type(s) ROUT (Delete Mode)
      Errors occurred during post-handling RS_AFTER_IMPORT for ISFS L
      The errors affect the following components:
         BW-WHM (Warehouse Management)
      Post-import methods of change/transport request CD3K900107 completed
           Start of subsequent processing ... 20060821140054
           End of subsequent processing... 20060821140146"
    Your inputs are highly appreciated !!

    Gimmo,
    Do u mean i need to install and transport 0material to test system ??? coz currently i didnt install 0material in dev also thnking i dont need coz its an export datasource .
    Regards
    Deenu

  • Transfer structure  0BUS_AREA_TEXT_HA does not exist

    We are transporting InfoCube - 0FIGL_C10. which we had collected in a transport request with grouping as in Data Flow Before. This request ended with return code 12 with error message "Transfer structure 0BUS_AREA_TEXT_HA does not exist, Error RSAR 440 when handling objects with type R3TR ISTS"
    After this I collected the transfer rules of 0BUS_AREA_Text with grouping as dataflow before and after. the transport of this request also failed with return code 12 with the same error message "Transfer structure 0BUS_AREA_TEXT_HA does not exist, Error RSAR 440 when handling objects with type R3TR ISTS"
    has any one faced this error, please suggest the corrective action to be taken,

    hi all,
    I'm now getting the same error when I try to activate a created "transfer rules" for any type of DataSource of my cProject.
    "Transfer structure 0DPR_***********_DA does not exist
    Message no. RSAR440"
    please show me on step by step because I'm a new guy of this SAP.
    Thanks,
    Chuong Hoang
    R&D engineer of global cybersoft - vn

  • Transfer Structure 2LIS_03_BX_QB does not exist

    Hi all,
    I got the following error message when transporting infosource 2LIS_03_BX.
    "Transfer Structure 2LIS_03_BX_QB does not exist"
    Maybe somebody can help me.
    Thanks and appreciate that,
    -Martin-

    hi Martin,
    try in dev rsa1->transport connection with infosource 2lis_03_bx as starting point, collection mode 'manual', grouping 'in dataflow before', and click 'source system assignment' (yellow box with x) and make sure r/3 source system is marked. then click execute. it will collect objects, after finish, make sure transfer rules, transf structure and datasource are marked following the infosource. create request and transport.

  • Transfer Structure activation

    Hi all
    I need to execute a specific Infopackage in the Quality System . However , When i try to open the infopackage it gives a message saying " transfer structure not yet active " . When I go to the Transfer structure and try to activate it , i get a message saying " Cross Client customising not allowed " .
    Can anyone please help me resolve this issue . I am pretty new to BIW .
    Thanks & Regards ,

    hi,
    you have to transport the transfer structure/rule from Dev system. your QA is set to not allowed changes.
    to transport, logon to Dev system, transaction rsa1 >> transport connection >> choose 'object types' in left frame then find 'infosource' in middle frame and expand, click 'select object' and entry your infosource where the trasnfer structure belongs to. make sure the source system is marked in 'source system assignment' (click yellow box with X), choose 'in dataflow before' for grouping and collection mode 'manual'. expand the infosource, make sure the transfer structure is there and marked. create request and transport.
    hope this helps.

  • Error while creating table 'EDISEGMENT' entry for Transfer Structures

    Hi Guyz...
    I've been facing a few issues regarding activation of transfer structures.
    I'll explain the whole process...so it makes sense to you guys.
    I've initially activated the Transfer Structures in BI Content for Master Data. Later on we faced some issues in the DEV server. So we had to transport all the objects and store them locally on a temporary location. When the BI DEV sever, was up and running, we transported all the objects back to the server.
    Now while moving the objects back to the sever. We had an errors in the Master Data Request (Log- Method Execution). After going into the log...this is what I found.
    Error while creating table 'EDISEGMENT' entry '/BIC/CIIA0DIVISION_TEXT'
    Error while creating table 'EDISEGMENT' entry '/BIC/CIIA0DISTR_CHAN_TEXT'
    Error while creating table 'EDISEGMENT' entry '/BIC/CIIA0MATL_TYPE_TEXT'
    Error while creating table 'EDISEGMENT' entry '/BIC/CIIA0SALESORG_TEXT'
    Error while creating table 'EDISEGMENT' entry '/BIC/CIIA0SALES_GRP_TEXT'
    I hope, I am clear here.
    Any suggestions, guys...
    Thanks,
    Regards,
    G

    Hi,
    Please check this link:
    Error while creating table EDISEGMENT entry
    Hope it helps.
    Thanks and Regards,
    MuraliManohar.

  • Error while activating Transfer Structure

    Hi Expert,
    we have upgraded BW3.1 to BI 7.0, we are getting error while activating transfer structure for 0mat_sales_attr and 0mat_sales_text.
    Error is Error while creating table 'EDISEGMENT' entry '/BIC/CIOD0MAT_SALES_TEXT'
    Message no. EA201
    Diagnosis
    An attempt was made to create the entry '/BIC/CIOD0MAT_SALES_ATTR' in table 'EDISEGMENT'. The attempt failed.
    System Response
    The operation was canceled.
    Procedure
    Please check whether the relevant entry already exists
    I have tried report RS_TRANSTRU_ACTIVATE_ALL also, but no success.
    I have checked table and entry is there. i have checked we31 for segment there also segment is existing.
    Regards,

    Hi Dubey,
    I am facing the same issue when i transport the datasource from DEV to QA.i applied the OSS Note 493422 ,But could not resolve the issue.Pls let me know the solution to fix  this.
    Thanks,
    Renu

  • Unable to activate Transfer Structure for Generated Datasource in BW3.5

    HI Experts,
    We have a scenario where the data needs to moved from DSO A to Cube B
    we have clicked the Export datasource and created 8(ODS A)
    when created IP for this it gave us all selection in selection screen but we required only 3 Characters
    <br> so we maintained the export datasource and saved it when we again tried to generate datasource it went to short dump       
    <br> with following messages:
    <br>  Short text of error message:                                               
    <br>  Serious internal error:              <br>   
    <br><h4> Transfer structure got deactivated and we are unable to activate it again even by RS_TRANSTRU_ACTIVATE_ALL <br>
    </h2>
    <br>                                                                               
    <br>Technical information about the message:                                   
    <br>  Diagnosis                                                                 
    <br>     A serious internal error occurred. It could not be corrected.         
    <br>  Procedure                                                                 
    <br>      The following information is available on this error:                 
    <br>      1.                                                                    
    <br>       2.                                                                    
    <br>      3.                                                                    
      <br>     4.   OSS note                                                         
       <br>    Check the OSS for corresponding notes and create a new problem        
    <br>      message if necessary.                                                 
    <br>  Message classe...... "RSAR"                                                
    <br>  Number.............. 001                                                   
    <br>  Variable 1.......... " "                                                   
    <br>  Variable 2.......... " "                                                                               
    <br>Source Code Extract                                                                               
    <br>Line  SourceCde                                                                               
    <br> 514         IF g_subrc NE 0.                                                 
    <br>  515           MESSAGE x001.                                                  
    <br>  516         ENDIF.                                                           
    <br>  517 *       Check new version neccessary                                     
    <br>  518         l_curr_version = c_s_is_admin-odsversion.                        
    <br> 519                                                                          
    <br>  520         IF l_new_version EQ rs_c_true.                                   
    <br>  521           IF i_without_versioning EQ rs_c_true.                          
    <br>  522             MESSAGE e023 WITH c_s_is_admin-odsname_tech                  
    <br>  523                               c_s_is_admin-isource                       
    <br>  524                     RAISING no_psa_version_allowed.                      
    <br>  525 *         ELSEIF i_without_versioning EQ 'C' AND                         
    <br>  526 *                i_without_transport  EQ rs_c_true.                      
    <br>  527 *--         special handling for migration.                              
    <br>  528 *-          current system is target system no transport request         
    <br>  529 *-          necessary if a new version is needed                         
    <br>  530           ELSEIF i_without_versioning EQ 'C'        AND                  
    <br>  531                  i_without_transport  EQ rs_c_false.                     
    <br>  532             RAISE inconsistency.                                         
    <br>  533           ENDIF.                   .                                     
    <br> 534                                                                          
    <br>  535           IF i_objtype = rsa_c_istype-data.                              
    <br>  536 *           check type of InfoSource first                               
    <br>  537             SELECT SINGLE issrctype FROM rsis                            
    <br>  538                            INTO l_isrctype                               
    <br>  539                           WHERE isource = c_s_is_admin-isource           
    <br>  540                             AND objvers = rs_c_objvers-active.           
    <br> 541             IF sy-subrc <> 0 OR l_isrctype = rsarc_c_issrctype-ods.          
    <br> 542 *             if generated ODS InfoSource,                                   
    <br> 543 *             no PSA versioning possible                                     
    <br>>>>>               MESSAGE x001.                                                  
    <br> 545             ENDIF.                                                           
    <br> 546           ENDIF.                                                             
    <br> 547           l_next_version = l_curr_version + 1.                               
    <br>548           c_s_is_admin-odsversion = l_next_version.                          
    <br> 549           l_transtru_odsname+13(3) = l_next_version.                         
    <br> 550 *         Don't use old progname but create new one                          
    <br> 551           CLEAR l_progname_ods.                                              
    <br> 552         ELSE.                                                                
    <br> 553           l_next_version = l_curr_version.                                   
    <br>554         ENDIF.                                                               
    <br>555                                                                               
    <br> 556       ENDIF.                                                                 
    <br> 557 *     set transtru_names for IDoc                                            
    <br> 558       c_s_is_admin-odsname       = i_transtru_name.                          
    <br>559       c_s_is_admin-odsname_tech  = l_transtru_odsname.                       
    <br>560     WHEN OTHERS.                                                             
    <br> 561   ENDCASE.                                                                   
    <br> 562
    Edited by: Sachin Shankarrao Dehey on Oct 20, 2010 8:59 AM
    Edited by: Sachin Shankarrao Dehey on Oct 20, 2010 9:03 AM

    Hi,
    Delete all the DS and try creating from starting, to export DS, with correct selections, and then Activate the Transfer Structure..
    Hope Helps,
    Regards,
    Laj

  • No Transfer Rule(s) available for the transfer structure 0FI_AR_4_DB in the

    Hi friends
      when i have trying to transport infocube 0fiar_c03 with infosource 0fi_ar_4 from development client.the following message has shown as error "No Transfer Rule(s) available for the transfer structure 0FI_AR_4_DB in the control table".pl let me know the possible cause of error.
    Rgds
    Tukuna

    dear Tukuna,
    it seems the transfer rules not transport.
    try in dev, change transfer rules,
    and from menu extras (beside go to) -> object directory entry -> transfer rules -> in next screen, check if package/development class is $TMP, click pencil icon, and choose your package/dev class, system will prompt request, create new request and transport.
    <b>if package/dev class isn't $TMP</b>, try following,
    rsa1->transport connection->left panel choose 'object type' and middle panel 'infosource' and 'select objects', and choose '0fi_ar_4' and 'transfer', then you will see 0fi_ar_4 in right panel, we will use this infosource to collect transfer rules.
    you may need to specify the source system assignment in transport connection when collecting objects, click 'source system assignment' and make sure your r/3 source system is marked.
    choose collection mode 'manual' and grouping 'in dataflow before', and 'execute', after objects collection finished, expand the infosource and make sure your transfer rules and datasources are there and marked. click transport (truck icon).
    also make sure you maintain the source system mapping in TARGET system (QAS), rsa1->tools->source system mapping (tcode rslgmp), fill 'orgsrcsys' with r/3 dev and 'trgsrcsys' with r/3 QAS, do the same for BW Prod with r/3 qas for 'orgsrcsys' and r/3 prod for 'trgsrcsys'.
    hope this helps.

  • PA Transfer Structure Issue while posting an accrual

    Hi
    I have an issue with accrual postings.
    I am trying to post an accrual (reversing journal) but an error is coming up with PA Transfer structure has not mainted in COPA, but i have maintained inKEI1 and OKB9 also.
    I really do not know as i have done this somany times previously.
    Any help will be apprecaited highly.
    cheers
    kris

    Hi Ashok
    Thanks for your prompt reply.
    I have checked and it is perfectly alright and i have just come to know that one of my team has transported a request wrongly that has messed up the system.
    Anyway thanks for your time.
    cheers
    kris

  • Transfer structure

    Hi All
    i have to create a transfer structure.
    in dso and cube i have 27 fields.
    but in tranfer structure it is showing 50 fields.
    i have to select the 27 fields out of 50 or i have to activate 50 fields in transfer structure.
    Thanks & Regards
    krishna

    Hi,
    Basically when creating the transfer structure you need to map the transfer structure fields with the ODS/Cube fields that are present in the communication structure.
    You just need to Transfer the fields, that you have identified in Data source to the transfer structure and map the relevant fields in the Transfer structure.
    Once the mapping is done. Just activate the Transfer structure.
    Most importatnt would be to decide on the mapping between data source and Communication structure fields.
    Hope it helps!!!
    Regards,

  • Transfer Structure 'USES' Box

    Hello Friends
    I have a quick question for you.What is the 'USES' checkbox for in the Transfer Structure on the far left side, right next to the CONVE box.What does teh 'Uses' box signify and what does a green check present or absent there mean.
    Thanks.

    Hi Krish,
    The column 'USES' identify whether the field is used in the communication structure or not.
    To give you an example, lets say you have two fields KTOPL and HKONT in your extract structure of the data source and you have transferred these fields to the transfer structure, however you have mapped only KTOPL to an info-object where as HKONT is not mapped (in assign info-object section of transfer rules tab). That means KTOPL will only appear in the communication structure. If you check the USES column, you can see that it will be checked (a tick mark) for KTOPL where as "blank" for HKONT.
    Hope it clarifes.
    Thanks
    Soumya

Maybe you are looking for

  • Stopped toll out of windows phone 7.8

    Hi...., I have seen on Nokia support site that there was a never firmware version available for all the previous generation of lumia ..... Now I heard that Microsoft has stopped rollout of 7.8 update ... But why ....please tell us ????? On the Nokia

  • Crystal reports has encountered a problem and needs to close

    Hi all. We have a dev machine XP sp3 with all critical updates applied.  It has Crystal reports 11 and visual studio 2008 on it (both have all updates applied).  We seem to have this problem consistently in crystal reports.  If we open a new blank re

  • Invalid field format (screen error) on Table Control

    Hello, When selecting a line or multiple lines on a screen made by me(using a Table Control), I get Invalid field format (screen error). Debugging the code it sends the message when looping the internal table on PAI to check if there were values chan

  • HT1386 the ituns can't start syncing my iPhone

    The ITunes can not start Syncing my iPhone  it was working well Recently I installed Picasa and Photoshop CS 6

  • Changing the Tax Percentage with an effective rate

    Hi, We are going to have new tax percentage w.e.f. 01Jan2008. And we are having a few conditions to be maintained basing on that future tax rate. Can somebody help me in changing the tax rates effective from a future date. Thanks & Regards, Raghava