What will be the steps to transport master data in BI 7? I have transported relevant R/3 data source and then replicated data source in BW. Then I start collecting BW info objects for the master data. When collecting BW info objects for transport, do I need include data source, transfer rule and info pacakges? If so, why do I need to collect data source again in BW system as it has already been replicated from the source system?

hi,
Dont transport master data differently.
If you are transporting standard cubes...Pls see the following steps....
1.Source system assignment.
2.Conversion(Source system ....Target system)
3.Grouping data flow BEFORE
4.Collection mode AUTOMATICALLY
5.display LIST
6.Drag and drop your Infoprovider.(Check infocube objects are selected properly or not...by default it will check
all the related objects)
7.Click on package...
Note:Check all infoobjects.....by default it will check some objects only....
hope it will solve your problem.

Similar Messages

  • Master Data is in Revised Version while transporting a request to add an attribute in existing master data infoobject

    Hi Experts,
    I am facing short dump when trying to send a request to add an attribute in Master Data Infoobject from DEV to QA.
    Although the attribute is getting added to main Master data Info object but main master Info object is in Revised Version.
    I have been searching the solution in SCN from couple of days and tried every single solution but none of them works for us.
    When I check in se09 I am getting the following message
    Program terminated (job: RDDEXECL, no.: 09445401)
       Execution of programs after import (XPRA)
    End date and time : 20150420094559
    Ended with return code: ===> 12 <===
    When checking in ST22 IN QA I am getting the following message
    The exception 'CX_RS_PROGRAM_ERROR' was raised, but it was not caught anywhere
      along
    the call hierarchy.
    Since exceptions represent error situations and this error was not
    adequately responded to, the running ABAP program
    'CL_RSDD_DS====================CP' has to be
    terminated.
    When I checked in ST22 in QA I am getting following dump
       31         RAISE EXCEPTION TYPE cx_rs_program_error
       32           EXPORTING
       33             text = 'Invalid DSO subtype'.                   "#EC NOTEXT
       34     ENDCASE.
       35
       36 *   get table name from DDIC
       37     CALL METHOD cl_rsd_odso=>get_tablnm
       38       EXPORTING
       39         i_odsobject = n_infoprov
       40         i_tabt      = l_tab
       41       IMPORTING
       42         e_tablnm    = l_tablnm
       43       EXCEPTIONS
       44         OTHERS      = 1.
       45
       46     IF sy-subrc <> 0.
       47       RAISE EXCEPTION TYPE cx_rs_program_error
       48         EXPORTING
       49           text = 'Error in CL_RSD_ODSO=>get_Tablnm'. "#EC NOTEXT
       50     ENDIF.
       51
       52     CALL FUNCTION 'DDIF_NAMETAB_GET'
       53       EXPORTING
       54         tabname   = l_tablnm
       55       TABLES
       56         dfies_tab = l_t_comp
       57       EXCEPTIONS
       58         not_found = 1
       59         OTHERS    = 2.
       60     IF sy-subrc <> 0.
    >>>>> RAISE EXCEPTION TYPE cx_rs_program_error
       62         EXPORTING
       63           text = 'Error in DDIF_NAMETAB_GET'.        "#EC NOTEXT
       64     ENDIF.
    I have attached the short dump
    Thanks In Advance
    Rashid

    Hi Tom
    Thanks for your reply.
    I am not sure what do you mean by Manually activated in Dev or QA . If you mean Dev then i did and also maintain the infoobject related tables using transaction SE14 but still same error.
    But if you mean in QA then QA is lock for manual activation but i tried though program RSDG_IOBJ_ACTIVATE but again failed. I also maintain the infoobject related tables using transaction SE14 but still same error.
    Regards
    Rashid

  • Overwrite data of master data infoobject

    Hi all,
    We have one master data infoobject ZASRYHMA. This infoobject does not have any attrbiutes but it has two compounding fields ZSITE and 0DISTR_CHAN.
    Now customer has a requirement in which value of ZASRYHMA can change for a particular site and distribution channel. Generally if this value changes then system creates a new entry in tables /bic/pzasryhma and /bic/szasryhma.
    What they want is to overwrite the existing entry.
    Is it possible to achieve?  It's a master data infoobject.
    Please provide your kind help.
    Regards,
    Nilima Rodrigues

    Hi,
    You have three fields as key field in table as shown below along with values,
    ZASRYHMA     ZSITE         0DISTR_CHAN
    A-1                     B-1            C-1
    A-2                     B-2            C-2
    now if you want to change the value of say second row to
    A-3                    B-2             C-2
    right?
    This is not possible just by overwritting in the info-object master data. Because these are key-fields system will treat A-3 as new value and create new entry, on top of this your A-2 master data values must have been used in transactional data.
    Only way I can think of is to delete the transactional data where ever A-2 is used and then delete ZASRYHMA master data and then upload master data for ZASRYHMA with new values. And then transacional data.

  • Data load stuck from DSO to Master data Infoobject

    Hello Experts,
    We have this issue where data load is stuck between a DSO and master data infoobject
    Data uploads from DSO( std) to master data infoobject.
    This Infoobject has display and nav attributes in it which are mapped from DSO to Infoobject.
    Now we have added a new infoobject as attribute to the master data infoobject and made it as NAV attri.
    Now when we are doing full load via DTP the load is stuck and is not processing.
    Earlier it took only 5 mns of time to complete the full load.
    Please advise what could be the reason and cause behind this.
    Regards,
    santhosh.

    Hello guys,
    Thanks for the quick response.
    But its nothing proceeding further.
    The request is still running.
    earlier this same data is loaded in 5 mns.
    Please find the screen shot.
    master data for the infoobjects are loaded as well.
    I can see in SM50 the process at P table of the infoobject the process is.
    Please advise.
    Please find the detials
    Updating attributes for InfoObject YCVGUID
    Start of Master Data Update
    Check Duplicate Key Values
    Check Data Values
    Process time dependent attributes- green.
    No Message: Process Time-Dependent Attributes- yellow
    No Message: Generates Navigation Data- yellow
    No Message: Update Master Data Attributes - yellow
    No Message: End of Master Data Update - yellow
    and nothing is going further in Sm37
    Thanks,
    Santhosh.

  • Data not uploading in Time dependent Master data Infoobject

    Hello All,
    I have a master data infoobject for HR entity and have to load data from PSA to that info object.
    The HR entity infoobject already have sone data like below:
    HR Entity
    Version
    Date from
    Date To
    x
    A
    01.07.2013
    31.12.9999
    x
    A
    19.04.2013
    30.06.2013
    x
    A
    01.09.2012
    18.04.2013
    x
    A
    01.01.2012
    31.08.2012
    x
    A
    01.01.1000
    31.12.2011
    Now the data in PSA is as follows:
    HR Entity
    Start Date
    End Date
    X
    01.01.2012
    18.12.2013
    Once I loaded this data to the infoobject, i can not see this value which is the latest value of this HR entity.
    Can somebody please explain how the data gets loaded in the time dependent master data infoobject and why this entry is not getting loaded in the info object.
    Regards
    RK

    Hi,
    did you activate master data after your load?
    You can check also version 'M' records and see if your record is there.
    The load went green?
    The problem is, that your entry overlaps all exisitng time intervals, which can't be deleted or merged as there may be dependent transactional data. You have first to delete the transactional data for this entity.
    Then you can delete the time-dependent data and reoload it from your PSA.
    BW will build then correct time intervals.
    The easiest is to change the time interval in PSA, see example below:
    At the moment the time interval is not accepted. But you can add time intervalls before 31.12.2011 and after 01.07.2013, Then system will create remaiing time intervals, e.g. your new record is:
    HR Entity
    Start Date
    End Date
    X
    01.08.2013
    18.12.2013
    Result will be:
    HR Entity
    Version
    Date from
    Date To
    x
    A
    19.12.2013
    31.12.9999
    x
    A
    01.08.2013
    18.12.2013
    x
    A
    01.07.2013
    31.07.2013
    Regards, Jürgen

  • Error while loading to master data infoobject hierarchy (0RPM_PORT_ITEM_HIERARCHY)

    Hi All,
    I have an issue while loading the data from psa to master data infoobject.
    DTP Error:
    When we had extracted the data from ECC to PSA, the values for field "IOBJNM" are not populated for 0RPM_PORT_ITEM_HIERARCHY
    Thus it is throwing an error while populating this data to the target.
    From where this field will fetch the values?
    Why these values are not being populated from ECC?
    Will there be any issue from BI side? can anyone help me on this.

    Hi Raman,
    yes I had extracted data in RSA3
    There are no values for the field "object".
    Do you have any idea why these values are missing?

  • Creation of Master Data InfoObject

    Hi All,
    I need to modify 0COMP_CODE Master data Infoobject, with adding some fields as attributes.
    I need to add few fields to 0COMP_ CODE, based on tables.
    And 0COMP_CODE should pull data from source tables while used at reporting.
    Can you please help me on this.

    Hello Sri,
    You can add the required inobjects in the Attribute tab of 0COMP_ CODE masterdata object.
    Also mark them as Navigational if you want them to be used in reports for drill  down, navigation etc.
    Now either you can enhance the masteradata datacource for 0COMP_ CODE in source system or create your own custom datasource.  If you are modifying the already existing DS them you would have to write ABAP code in CMOD for those fields you are adding to 0COMP_ CODE.
    Replicate it to BW. Activate the datasource. Create transformations(modify transformation in case you haev modified the already existing DS)  to update these new fields to 0COMP_ CODE masterdata attribute.
    Now rest of  the things are same, like create DTP or IPs etc.
    Now as you would have marked these new objects as Navigational in 0COMP_ CODE masteradat attributes tab, you will be able to use them in query design.
    Hope it helps...
    Regards,
    Pratap Sone

  • Steps to create customized Master  data infoobjects in BI 7

    Hi all,
    Can anyone please send the detailed steps to create customized master data infoobject in BI7,and also the data is to be extracted from two different datasources from two different source systems.
    Regards,
    G.Monica Roja Flora.

    Some data modelling tips while creating master data infoobject and extracting data from different source systems -
    If there are identical characteristic values describing different objects for the same characteristic in various source systems, you have to convert the values in such a way in SAP BW so as to make them unique.
    For example, the same customer number may describe different customers in different source systems.
    You can carry out conversion in the transfer rules for this source system or in the transfer routine for the characteristic.
    If work involved in conversion is too great, you can compound the characteristic to the InfoObject Source System ID (0SOURSYSTEM). This means it is automatically filled with master data. The Source System ID is a 2-character identifier for a source system or a group of source systems in BW. The source system ID is updated with the ID of the source systems that provides the data. Assigning the same ID to more than one source system creates a group of source systems. The master data is unique within each group of source systems.
    http://help.sap.com/saphelp_nw2004s/helpdata/en/80/1a6399e07211d2acb80000e829fbfe/content.htm
    Hope it Helps
    Chetan
    @CP..

  • Duplicate records in master data infoobject...how to delete it...pls help

    hi all,
    how to delete duplicate records in master data infoobject which has no requests because it is a direct update?

    Hi,
    Right click on the info object and
    select Maintain
    in that you will get the Master data table
    from that select the Record and delete it.
    hope this solves your query.
    reward points if useful
    regards,
    ANJI

  • Request deletion from Manage-Master data infoobjects

    Hi All,
    I have a master data infoobject, for which i have created a process chain for deleting the data. I am deleting the P and S table in a program.
    When i run this chain data is getting deleted from the tables, but i see the request (green/red/yellow) in the manage section of the infoobject. I want to delete those entries as well from the manage section.
    Any inputs ?
    Regards,
    Sandeep

    Hi,
    to delete those entries you will have to delete the entries from standard SAP tables...all the tables begining with RSREQ stores the information about the requests...but you may not have authorization for that...
    did you tried RSDMD_DEL_BACKGROUND or RSDMD_DEL_MASTER_DATA_TEXTS function modules....you can use in the program and use at as a ABAP variant in the process chain.
    Thanks
    Ajeet

  • Transporting master data

    Hi All,
    I have heard the we should not transport master data.Can somebody pls tell me what are repurcassions if i do so?Can you give me the list of some SAP notes where SAP doesnt recommend to transport master data?
    Archit

    Hi,
    When u create master data system will not create any transport request. The transport will be done only when the request is created. So master data is client specific, thats why we have to create the master data for every client separately.
    This clarification may clarify ur doubts.
    Ramesh

  • Master data infoobject can't handle duplicate records after SP10

    Hi
    I am trying to load master data which happened to contain duplicate records from the source system.  In the DTP of the master data infoobject, I have ticked the 'Handle Duplicate Record Keys' checkbox.  After executing this DTP, the duplicate master data records were trapped in the Error Stack.  I am expecting overwriting of the duplicate master data to take place instead.  I understand that this error was fixed in Note 954661 - Updating master data texts when error in data package which is from SP9.  After applying Support Pack 10, the master data infoobject just can't handle records with duplicate keys.
    Please let me know if you manage to fix this problem.
    Many thanks,
    Anthony

    Found a fix for this problem.  Just applied this OSS note  Note 986196 - Error during duplicate record handling of master data texts.

  • Adjusting the SID table for master data infoobject

    Hai
    Im trying to activate one master data infoobject. But it says the error like below
    <b>The SID Table /BI0/SBBP_DELREF must be converted incompatibly with an activation of characteristic 0BBP_DELREF (changes to the key in the table). Table /BI0/SBBP_DELREF contains data. Parts of this data were lost in the conversion</b>.
    or
    <b>Undo the changes that led to the incompatible conversion (the changes in the key) or delete all data from table /BI0/SBBP_DELREF.</b>
    So how can i adjust the SID table for this .
    pls tell me
    kumar

    Hi,
    you'll have to delete ALL the master data for this IObj. Therfore you'll have to
    delete all data in ALL the IObjs using 0BBP_DELREF (ODS, CUbes and characteristics).
    Then activate your IObj. You will go through some step which I explained in the
    following thread
    Re: Urgent...Company Code lenght has been changed
    Extract:
    1. Delete 0COMP_CODE master data.
    - get objects list using 0COMP_CODE with loaded data: I suggest to delete
    master data via AWB (right click the characteristic). If it can't be deleted because
    it is used display the deletion log (via AWB or tx SLG1 / RSDMD, MD_DEL).
    - delete loaded data for the list above.
    This should not be too much since you are in DEV.
    2. change 0COMP_CODE length
    - change the length to 4;
    *- Activate your IObj. You'll get a popup log, validate. Activate despite warning and
    errors. You will get An error message, validate.
    You should get an horizontal pane with the activation log. Read it for your personal culture but if you don't have time then don't...
    - Next the system will prompt to convert the tables: answer YES. The system will ask to schedule the table conv. in the background, go4it.
    - next is the SE14 screen for the P table: Hit Activate and adjust (Direct
    execution, or in the back as you wish). Answer yes to the mass processing
    question and yes (again) for request adjust online. Your table should be converted successfully.
    - go back twice from this screen (leaving SE14 tx and return to RSD1). reread the update log if you wish.
    - repeat from the *- above... it will perform the very same for all other P tables of IObj using 0COMP_CODE and the 0COMP_CODE S table.
    Your IObj is reactivated again. So should your ODS/DSO objects (check activate for example). Cube didn't need to convert tables since the MDID is note posted in any table of a cube.
    Please note that once your IObj is in revised version you can perform the same via the menu extras / database table / convert all (see my previous post).
    Now you have to evaluate the task. Of course that is a work to fix the mistake.
    Depending on when it has be changed it may be worth to restore your DEV sys with a backup (loose work performed from the backup until now).
    hope this helps... otherwise, revert.
    Olivier.

  • Updating the Master data Infoobjects attributes from the Portal

    Dear All,
    There is a requirement where through portal i want to  retrive the master data infoobject ( based on the value seleceted for that infoobject by the user ) and its attributes in the portal , edit them and save them back so that the updated values goes back to BW master data infoobject data base tables and updates the value.
    Eg . I have Natural Account master data infoobject in the BW with attributes fucntional area and expense center.Based on the user selection of any values for the Natural account lets say 01110 , then for 01110 natural account the portal should display the correspoding attributes values of fucntional area and expense center.Lets take this values as 10 , 20 respectively for fucntional area and expense center . What I want to do now is to change these attrbute values to 30 and 40 and I would like to save it back as the changed attribute values for that natural account for 01110 with new attribute values 30 & 40 respectively for fucntional area and expense center .
    Is this possible through portal and BW?
    Any idea on this would be appriciated.
    Regards,
    Ankit

    Hi Ankit,
    this is a quite tough but not impossible requirement. Maintaining Master data is possible with Visual Composer and some function modules (at least that's one way I know). However it could be a bit complicated maintaining attributes Master data depending on your data model. This How might help getting familiar with this topic:
    Maintaining BI Master Data with SAP NetWeaver® Visual Composer
    Good luck.
    Brgds,
    Marce

  • Loading getting stuck to master data infoobject

    I am loading data to a matplant master data infoobject ,its taking hell lot of time in loading.....infact its getting stuck at a point .I am not sure what can be possible issues.
    though I put some filters on plant then it loaded for some plants ,but still in some plants its getting stuck.
    Actually there are some field enhancements done and and extraction code  for those enhanced fields are written in R/3 side.

    Hi.
    1) First go to SM58....check if any TRFC is stucked......then press F6 to push them....
    2) After pushing also if the load does'nt proceed.......then check for Shortdumps in ST22......
    also check the jog log >> copy the request nimber >> go to the source system >> SM37 >> give the request no (BI as prefix) >> check the job log........if you find Sysfail.....that means short dump......
    Then cancel the job if it is active.........make the QM status red and repeat the load.......
    3) Also check the system performance........if there is any locks or deadlocks in ST04...........also check SM21......
    Hope this helps you.......
    Regards,