Hi Experts,
I know its not recommended but for some reasons we were trying to move 0material_attr data source and transfer rules and transfer structure 0material_attr_ba from quality system (QAS) to Development system. And every time we are getting the error "Source system QAS does not exist" while importing the request in DEV.
The reason for this error is that it is still keeping the reference source system of quality as QAS which is not there as logical system in DEV. My question is isn't it should automatically refer to R/3 DEV when imported to development system.
Thanks
Vishal

Hi,
As pointed out by Joke in the previous post, you need to maintain the mapping of logical system name for transportation.
In Dev,  go to RSA1> Tools--> Conversion of logical system names.
Here create new entries.
Your Original Source System would be the QAS Logical System Name & Target Source System would be DEV Logical System Name.
Once entry is saved, re-import the transport request and check.
Hope this helps!

Similar Messages

  • Source System Error While transporting

    Hi SDN,
    We are transporting requests to a deployment test box SN1 and we are getting this error message while we never got this error message transporting to QAS and in QAS we did not need to create DEV010 as a source system - setting up RFC connection was sufficient.
    Any thoughts?
    ===========================================================
    Source system DEV010 does not exist
    Message no. RSAR409
    Diagnosis
    Source system DEV010 is not known.
    System response
    The imported data for data source 8ZM_C42 was deleted again as the referenced source system does not exist and no mapping is defined in table RSLOGSYSMAP to an available productive source system.
    Procedure
    Create the referenced source system in the Administrator Workbench or define a mapping to a known source system in table RSLOGSYSMAP.
    You get to the maintenance using Tools -> Conversion of the logical system names.

    Speak to your basis team and ask them to make entries in table:
    RSLOGSYSMAP .
    Are you trying to transport info source or any source system dependt object? If so, this error is understandable.
    This has been discussed several times and pl search the forum.
    Ravi Thothadri

  • Source System Error for 0Material_Attr

    Hi Gurus,
    I have New BI System, when i m loading 0Material_Attr, the whole data is coming but with the status Red. May b the error is with source system. I checked in PSA maintenance and the error detail in source system is mentioned below.
    "Value 'A3000014500L ' for characteristic 0MATERIAL is in external format"
    "0MATERIAL : Data record 1 ('A3000014500L '): Version 'A3000014500L ' is not valid RSDMD 194".
    for detail error check the link below
    https://docs.google.com/document/d/1v4uHeg6Ci29zv0qJ21dOH7gttuQyg_VZsLM2IMfZEuM/edit?hl=en&authkey=CLnd8P4H
    can anybody help in this regard.
    Thanks in advance.
    Regards
    Manna Das

    Hello Manna Das,
    0Material has conversion Exit MANT1 which converts the Material in the external format to internal format of the system.
    Can you please check if the Converison exit is there?
    Thanks,
    Sarat

  • Production transports  referring to Dev Source system

    Hi All,
    We have Dev -> QA -> Prod setup for both BW and R/3.
    In BW corresponding source systems are created in each server.
    Transport Connection Source sytem mapping :
    In BW QA , I have mapped the source systems R3DEV to REQA.
    In BW PRD ,I have mapped the source systems R3QA to R3PR.
    When I move the TP from QA to Prod , it gives error source system "R3DEV" does not exists.
    Why is this behaviour ? It should refer to R3QA.
    Shall I maintain R3DEV to REPR in production ?
    Pls let me know , it's a question of production !
    Regs,

    Hello Subir,
    As far as I am aware,when transports are done,the transport first moves from Dev to QA.
    Then QA testing is done.Once testing confirmed OK,next is step to transport to prod system.
    Now,I believe transport is done not from QA to Prod but from Dev to Prod system.
    So I think u have to change source system mapping so that dev changes to prod system once transported.
    Request others to confirm my thoughts..
    cheers,
    Vishvesh

  • Source system error - RFC connection failed

    Hi Gurus,
                  I have installed ECC6 on my PC but not when i am trying to created the DS its not allowing me its saying appl comp hierarchy for source susyem "T90*" doesnt not exist.
    so tried going to source system -> done a check for my source system then i got the following errors
    Source system "T90*" is inactive
    Entry in outbound table not found
    Entry in inbound  table not found
    Basic type does not exist
    Check failed for RFC connection T90CLNT090 ; check destination
    can any one tell me how to fix this issue?
    Regards,
    Ravi

    Hi Ravi,
                Did you run appication component hierarchy in source system(TX-RSA9)
    then activate your data source
    then replicate in BW system.
    Check here for BW connectivity with source system.
    https://www.sdn.sap.com/irj/scn/wiki?path=/display/bi/stepbyStepBusinessIntelligence
    Thanks,
    Vijay.

  • Create Source System - Error

    Hi Gurus,
    I have to create a conexion with R3 so i did :
    1)Create RFC Conexion in SM59
    2)Create Source System in RSA1
    But in the last step of the creation Source System in RSA1 shows up the following Error Message:
    "The source system already exists"
    So i checked in the source system list, and it does not exists.
    Can anyone help me about this?
    THANKS A LOT !!!

    Hmm.. not very good over here.. but can you dubleclick and see if they are leading to different clients or not?
    I think they are 2 different clients of the R3's .. so this should be posible..
    Did you created a new logical system and new RFC destinations for this new one?
    May be that it is pointing out to the existing destination..
    regards,
    Hari

  • Source System Error

    Hi Experts ,
    I have to create a source system for Production server in BW Ides .
    My Production server client 999 , It is assigned to Logical system CL999.But CL999 Uses a RFC Destination to support place so it could not be changed .
    So i created own logical system LSYS999 .  And created a RFC Destination to BW and used that in Port .But my Logical system is not assigned to client.
    If i check My RFC connection on both sides it works fine.
    The source system is also created in BW , RSBASIDOC Table also has Active state.
    I created a generic data source in Production Server , Replicated in BW , It also came.
    Now the problem is when i assign Data source to info source , During Activation the following error comes
    <b>Error in source system CL999</b>
    Message no. RSAR502
    Diagnosis
    With Remote Function Call to system CL999 error Function module "<b>RSAOU_BWBC_GET</b>" not found.  ccurred.
    Procedure
    Remove the cause of the error.
    How to solve this .....Awaiting for your great response
    Regards
    Shiba

    Hi,
    please go in rsa1 onto the relevant source system and press "check". I assume that the connection is not fine. This will help you to get some more detailed information.
    Follow the protocol.
    hth
    cheers
    sven

  • Source System Error in BW

    Hi,
      RSA1-->Source System...context menu and check
    I am getting the following error
    Result of the destination check: No authorization to log on as a
    trusted system (Tr usted RC=1).
    how shall i proceed
    Thanks

    hi Krishna,
    check SM59 for RFC destination used for that source system, normaly the same name used.
    try to check 2nd tab 'logon/security', check option for 'trusted system', try to change to 'No'.
    you may need basis assistance.
    hope this helps.

  • Collection in source system error

    Hi,
    Recently we just performed a BW SP upgrade to 3.0B level 28. During our first extraction after upgrade on production for 0HR_PY_1 (Payroll Data) infosource, we encountered a message "Collection in source system ended".
    Anybody has any clue about the cause and how to go about resolving it?
    Thanks.
    Best regards,
    Taly

    hi Taly,
    datasource need to be replicated from source system (r/3) in production.
    area to check -> in monitor request, menu 'environment' check job overview both bw(datawarehouse) and r/3(source system - equal to transaction sm37 - see if job cancelled and any helpful error message like sql error., from menu-environment check the same bw and r/3 for shortdump (st22), transaction rfc, ale management, system log(sm21) and so on, please let's know what's your finding there, possibly source system problem with that message, may ask basis for help. hope this helps.

  • Transport InfoSources to New Source System

    Hi.
    When implementing BW in our QA environment, all InfoSources, and their related InfoPackages, Transfer Rules, Update Rules, etc.) were created using a temporary R3 QAS source system mapping (ex.TMP).  We are now removing this temporary client and  I now need to change my InfoSources (along with customized Start Routines, InfoPackages, etc.) to point to a new QAS source system (ex. PRM). 
    Note that this new source system is already identified as a source system for BW and all DataSources created on TMP have been transported to PRM.  Subsequently, all DataSources have been replicated from PRM to BW. 
    However, I'm having trouble on the BW end.  I can't easily
    transfer the InfoSources, etc. to the new source system.  I've asked some BW / Basis folks and they suggest transporting the InfoPackages out-of and then back-into the BW QA client.  Is this possible?  Is there a better way to push my InfoSources, InfoPackages, etc. from the old source client (TMP) to the new one (PRM)?  Thanks!

    Dear Dave
    Please do not attempt to change the logical system name your self, as I feel that you have not tried it before.
    This is some thing that your basis people have to do. Depending on the size of database this change can take from 2-24 hours (not exact times, but just some thing to show the magnitude of the task).
    Good luck
    /FZA
    Message was edited by: Fariborz Zangoui

  • Source system Error of BI- Incorrect Unicode Settings

    Hi gurus,
    We are facing problems in the source system of BI 7.0,after
    installation it self .
    As we Click on Check for the source systen of BI it is throwing an
    information .
    "The unicode settings for destination BD1CLNT300 do not match the source
    system."
    This is leading to failure of Export Datasource creation for BI system.
    and even BEx Personalisation for History.
    Please Help.
    Our system is having  following components:
    SAPABA -700-18-SAPKA70018
    SAPBASIS-700-18-SAPKB70018
    PI_BASIS -2005_1_700-18-SAPKIPYJ7I
    SAP_BW-700-0020- SAPKW70020
    BI_CONT -703-14-SAPKIBIIQ4
    Please suggest the correction as per the patch Level.
    Regards,
    Deepak kansal

    Hi Deepak
    Please check below link, let me know if this doesnt help you
    [https://www.sdn.sap.com/irj/scn/go/portal/prtroot/docs/library/uuid/6038903c-3c32-2c10-2c8b-c5bb71baab67]
    -DU

  • Error when creating R/3 source system in BW3.5

    I HAVE CREATED SOURCE SYTEM FOR R/3 TO PERFORM EXTRACTION IN BW-3.5.
    AFTER I DID ALL THE BASIC SETTING LIKE CREATING LOGICAL SYSTEM AND ASSIGNING CLIENT AND CREATING RFC DISTINATIONS.
    I TRY TO CREATE SOURCE SYSTEM BY RIGHT CLICKING ON SOURCE SYSTEM ROOT NODE AND SELECTED THE OPTION SAP SYSTEM FROM RELEASE 3.0D(MANUAL CREATION) AND ENTERED
    RFC DISTINATION : (LOGICAL SYSTEM ID OF R/3)
    LOGICAL SYSTEM NAME: (LOGICAL SYSTEM ID OF R/3)
    SOURCE SYSTEM NAME: (R/3 SOURCE SYSTEM)
    ERROR MESSAGE -- NO:447
    BASIC TYPE ZSBA005 DOES NOT EXITS
    ACTIVATION OF SOURCE SYSTEM FAILED
    PLEASE HELP ME IN THIS ISSUE..
    CHEERS
    AMAR.

    Hi,
    Kindly do not type completely in CAPS.
    Take a look at SAP Note 140276 to correct errors in source system assignment.
    BR/
    Mathew.

  • Error occured in the Source system while loading mater data

    hi all
    While loadng the master data info package.The request is getting failed with error occured in the source system.
    error message says "<b>if the source system is a Client Workstation, then it is possible that the file that was to be loaded was being edited at the time of the data request. Make sure that the file is in the specified directory and is not being edited, and restart the request</b>".
       I had tried repeating the Request but again It is getting failed.
       please help me resolving the issue.
      Thanks(=Points)
          Priya

    Hello Priya
    If u r loading thru flat file
    1. Check the correct path in infopackage
    2. Check if it is opened,if it is then close it and run package again
    If loading thru R/3
    1. Check DS is not opened in change mode
    2. Check if RSA3 is able to extract data...if it is then check in RSA7 and chk IDOC status...
    3. Are you running init..then make sure no document is posted in R/3 side...
    Thanks
    Tripple k

  • Failure of infopackage step in process chain - Error in source system.

    Hello Experts,
    We are experiencing this during the execution of process chain.
    All the step for data loads within BW(DSO to DSO, DSO to cube) are failing with error -
    - Error in source system
    - Error during data selection
    Please note that we are 3.5 data flow and thus, data load within BW is through emulated data source and the infopackage. Steps running such  infopackages for emulated data source are failing in process chain with error above.
    Surprisingly, when I run the infopackage manually out of process chain it runs successful without any error. But when I run through process chain it fails.
    Any clue or suggestion? We have already tried doing re-initialization for infopackage.
    Appreciate your inputs.
    Regards,
    PK.

    Hi,
    When we run data loads thru process chain it will run in background. as per the available background application servers your request will be processed.
    as my your during your load time server will be on high load.
    please check your system busy schedule and schedule your process chains.
    Check Tx - SM50, if you have less application servers, then ask basis to create few more to application servers to process the request at busiest time.
    check about increasing parallel processing and default data transfer settings.
    go to info package---> menu scheduler--> data settings for default data transfer.
    Thanks

  • Source System mapping for BW configuration transport

    I create a data model mapped to the testing source system i.e DEV201 but the configuration source system is DEV200.
    Now i am about to transport the BW configuration to BW-QAS , I am wondering if I have to assign the data model to the config. source system(DEV200) or i can created a transport request attached to DEV201 ?
    Is there any concern on this ?

    Hi,
    I'm not clear your system landscape. Do system landscape like that:
    BWD (BW development) --> DEV201
    Now you want transport all objects to BW_QAS with connected to DEV200.
    If this is true, you do like this:
    - On BW_QAS: create source system (DEV200). Maintain conversion of source system after transport (Original: DEV201; Target source system: DEV200).
    - After that transport your modeling from BWD to BW_QAS.
    Hope this helps
    BR
    TRUC

Maybe you are looking for

  • HP LaserJet P1102w will only print wirelessly if I turn the printer off and on again

    I have 2 Laserjet P1102w that work fine printing through USB.  However, I was hoping this printer could become the standard wireless printer for individual users in the office.  I have setup 2 different printers wirelessly with their own static, rese

  • BP EEWB field in CRM to  ECC zfield in KAN1

    Hello  all .. I have added  few custom fields to BP through EEWB  and want them to replicate to ECC . Here are the steps I followed ... We are on CRM 5.0 and ECC 6.0 1) Added the fields in same order as EEWB in  BSS_CENTIX (component type GB_BAPIUPD

  • Help with importing multiple folders

    Hi, I've just bought a new computer which has come with PE9 pre-installed. It looks like it could be a great program but ... Two big problems. Firstly, I tried importing all my pictures from "My Pictures". All my pictures are neatly arranged into the

  • Manually upgrading Thinkpad Yoga WiFi card

    Hey all, I bought a TPY from Newegg, which shipped with the Intel Wireless-N 7260. The laptop finds and connects to my home network fine, but can't find my work WiFi network at all. I've tried a few different drivers to no avail. Would buying and ins

  • Why is text washed-out when I'm using a color-filled text box?

    I have created some text boxes in InDesign. I've colored them a lighht green, and I am trying to type into them but my text is washed out, even though I am picking a much darker text than the box fill. How do I fix this? I am working on a tight deadl