Triggering of Notification from Follow Up action

hi
SDN,
in calibration order. if i reject inspection lot ,system should trigger notification as follow up action.
Can any one suggest the name of functional module that can be assigned in follow up (QM customizing)action so that system trigger notification as inspection lot get rejected.
All other follow uop actions like.. order teco, equipment status change, etc. i have done and tested.
Regards,
amit

hi,
Thanx for promp reply. i have tried to assign these functional module in followup actions but system throwing en error . it's given below -
Function module QFDL_INIT_NOTIFICATION does not have E_SUBRC parameter
Message no. QM403
Diagnosis
The interface of the function module you entered is not compatible with the interface of the sample function module.
Procedure
Check the function module and add the missing parameters to the interface.
suggest how to proceed.
regards,
Amit kushwaha

Similar Messages

  • Send mail from follow up actions for tasks in service notifications!

    Dear All,
    I want to send mail to the user from a follow up action in the task assigned to a service notification.
    In customizing which function module I should select for follow up actions for tasks?
    Thanks and Regards,
    Satyajit P

    Hi,
    You can use function module QM06_FM_TASK_SEND_PAPER or QM06_FM_TASK_SEND_PAPER_ATTACH.The document is sent only after the associated notification is saved.You need to enter the function module "QM06_SEND_REPLY_STEP2" in Customizing of the action box as "FM when saving".

  • Create  notification as follow up action

    Hi,
    Can anybody explain to me which functionmodule (follow up action) to use for creating a PM notification from an inspection lot UD.
    Thanks in advance
    Peter

    Hello Nehal,
    thanksfor your reply.
    I have linked the inspection type to a PM notification type and i want the Notification to be created on the Equipment.
    I can already create if manually, from the inspection lot, but i want to do this automatically. In the selected set for the Usage decission, you can define follow up actions, but when checking the follow up actions I'm not sure which function module to use.
    So which function module should i use? or are you saying that there is no standard function module and  that i should write the function module from scratch?
    There is no way to create a PM notification from the inspection lot with standard SAP?
    If somebody knows, please let me know. Thanks
    Peter

  • If Quality notification as follow up action fails

    Dear all
    I have a situation where Quality notification is configured as a Follow up action once the UD is made.
    So I am getting Create notification screen once UD is filled and SAVE button is clicked.
    In Case some wrong data is entered in the Create notification screen and I am coming out of Notification without saving the notification.
    The status of the inspection lot is getting flipped to UDed as expected.
    But is there any setting where i can define if the Followup action is not successful( Notification not created), then wont make the UD of Inspection lot also. (OR some user status will get updated saying Notif not created etc..)

    Hi Navdeep,
    Thanks to Anand for his correct feedback.
    Please note that as per standard SAP, unless and otherwise there is a defect created, there can't be a 1:1 link with inspection lot with the notification, though in the notification header table there is a placeholder available (QMEL-PRUEFLOS) to capture this inspection lot field. You are trying to use a follow-up action wherein, after UD you are always creating a notification based on business case. I believe, the FM you are using in follow-up action, is not presently populating QMEL-PRUEFLOS. So there can't be a link to find out when there is failures in notification creation, but UD happening successfully.
    You can try out the below approach -
    Approach - 1
    During the UD save process, there should be additional checks happening. Ask the follow-up FM to update QMEL-PRUEFLOS or TEXT field with inspection lot for all successful notification creation and UD update, and send a confirmation email to approver or task processing partners, or the UD processing user ID (This email part can be skipped in case if this is not required). In case of any failures in notification creation at save, it should truncate the UD save process too and send a message to UD processing user for this failure.
    Approach - 2
    You can create a batch job running at the background to validate for which inspection lot there is no notification created, even though UD is done. Send a mail to the UD processing user to create a notification, as that is not created. User can then create it manually it by updating TEXT field in notification in foreground.
    Thanks,
    Arijit

  • Changing the status of Equipment in a follow up action

    Hi All,
               I have a requirement in which a function module will be triggered for a particular Follow up action.
    In this FM we have to determine the equipment and the Maintenance Order , if both are available , status of the equipment
    should change to 'A' , status of maintenance - order = 'Technically completed' and Maintenance Notification = 'Notification Completed' .
    How can this be done.? I am able to change the status of Maintenance order and notification but can anyone help me in
    determining the equipment and changing its status to 'A'. ?
    Thanks in advance.
    Vasuki

    Hi Gajesh,
                     The process is as follows :
    1) During Calibration of a product,depending on the technician's User decision , 3 follow up actions are created.
    2) Each follow up action has one FM associated with it, which is customised in      SPRO > Display IMG > Quality Management > Quality Inspection > Inspection Lot Completion > Define follow-Up Action .
    3) In the first case ( first Follow up action when the inspection is successful) the first FM is triggered. In this FM we have to perform the following steps :
                                   a) Determine the Maintenance Order and the equipment.
                                   b) Incase both are available, status of equipmnt should be changed to 'A',
                                       Maintenance Order should be changed to 'Technically completed' and
                                       Maintenance Notification to 'Notification Completed' .
    If you need further info pls let me know.
    Thanks,
    Vasuki

  • Notifications created as follow up action from a notification????

    Hi all,
                I am creating a Quality Notification as a folloup action of a MAintenance Notification.
                The Quality Notification is craeted in the background.
                Now I want which are the Quality Notifications created from a Maintenance Notification.
               In short I want the relation between Reference Notification and Notification created as Followup Action.
              How I can see the notifications creted with reference to current notification in IW220r IW23.
              Also how I can see which is the reference notification for current notification in IW22,IW23.
    With best regards,
    Narendra

    Hi,
    In IW22 or IW23 click document flow button or press CTRL+F4 you can get both  PM & QM Notification no.
    In QM notification you can see the PM notification no. as reference.
    Regards
    Chandru

  • Post serialized part from free to block stock with a follow up action

    Hi,
    I try to post a serialized part from free to block stock, but the standard function modules QMLR_FREE_TO_BLOCKED_STOCK,  QMLR_FREE_TO_BLOCKED_STOCK_ST2 work good with not serialized parts, but it doesn't works with serialized one.
    I create quality notification with serial number reference in RQM00-SERIALNR field, when I execute the follow-up function the M7175 error message appears.
    Someone know a solution to this issue?
    Thanks
    Marianna

    Hi The standard FM will not update the serial no for the material. So when you are doing the material movement through follow up action system can not move the material with out serial no. So you can change the functional module aith help of abaper to fetch the data from quality notification field.
    Regards,
    Smruti

  • Quality Notification: Create Task as Follow-Up Action

    Hi QMu2019ers
    I have a requirement from my business, to create tasks as a follow up actions from completed tasks. Let me explain the process.
    We have a catalog with 4 codes e.g. ZTS1 u2013 0001 to ZTS1 u2013 0004
    When the user assigns ZTS1 u2013 0001 to a task in the notification and that task is set to complete, we want the system to automatically create the next task in the catalog, i.e. ZTS1 u2013 0002, when that task is complete the next task from the catalog is added and so on.
    I have looked into follow-up actions for tasks, but there does not seem to be a standard option for this.
    Does anyone know how I can implement such a solution?
    Many thanks for any advice given.
    Neil

    follow-up actions of  tasks is triger when the tasks are assigned into the notification, not when the task are completed.
    Try user-exit QQMA0014, you can assign additional tasks before notification is saved.

  • Create new notification from action box

    Hi,
    We have the following scenario: In transaction IW52 (Notification modification) we have created a new follow-up function, with this new function we want to create a new notification with some data from the current notification.
    The activity of the new follow-up function executes a Z function module. Everythings works fine except that when the function module is finished and the new notification is created it shows the IW52 transaction with all fields blank.
    We have tried to do it with the functions mdules from IQS0 group function and with business object BUS2080, both options had the same result.
    With the debuging we have found that when the follow-up action is called from standard code in SAPLIQS0 - LIQS0F75 - FUNKTION_ACTIONBOX_F75 the viqmel is null when follow-up action is ended:
              CALL FUNCTION l_funktion-baustein
                EXPORTING
                  i_viqmel       = viqmel
                  i_customizing  = l_funktion
                TABLES
                  ti_iviqmfe     = l_iviqmfe
                  ti_iviqmur     = l_iviqmur
                  ti_iviqmsm     = l_iviqmsm
                  ti_iviqmma     = l_iviqmma
                  ti_ihpa        = l_ihpa2_tab
                EXCEPTIONS
                  action_stopped = 1.
    Thanks.
    Edited by: Sistemes Emaya on Oct 28, 2011 10:46 AM

    Hi,
    In this case follow below steps mentioned below.
    Action box in IW52 trigger your Z Function module so use below steps may it will help you.
    Inside your Z Function module-
    1 ) Get notification number from Parameter id using command "GET PARAMETER ID XXXXXXX" .
    2 ) Fetch relevant records from database on behalf of notification number which you get in step 1.
    3 ) Use records in your Z Function module to create another notification as per your requirement. 
    Thanks,
    Vijay

  • Follow-up action in IW42

    Hello.
    I'm currently using a notification task (linked to a follow-up action) to generate a notification N3 from a notification N1.
    It works perfectly in transaction IW22.
    When I try to use the same task in IW42, the notification gets updated but no follow-up action is triggered....
    Any idea?
    Thanks,
    Nicolas

    Hi,
    Copy the function module in customizing under Quality Inspection -> Follow up action and modify the standard functional module as per your requirement by the help of ABAPer and assign the same functional module to same IMG.
    Regards,
    Babu.S

  • Follow-up action : please help - Inspection Lot related

    Hi,
    I am having the following trouble:
    Through MB02, a printout is generated to the local printer (LOCL).
    However, through QA11, when we save, we have a custom follow-up action attached that pops-up a
    dialog screen.
    The follow up action is triggered when a usage decision is changed for the inspection lot.
    The follow-up action (configured in IMG) calls a Function Module and a screen, which in turn populates
    a value into a custom DB table (based on the buttons, on the screen, sending either to LOCL or to a
    zebra printer).
    Now, what has to happen is that after inserting the value into a custom table, it should also open a sapscript and output.
    The Sapscript and print program are there, with the print program being created 3-4 years ago by someone
    else. However, even though we have code in the print program to update nast, in turn creating a message
    for output (1st the custom DB table is checked to see if the values match, MATNRCHARG), It does not update
    NAST. When we go through MB02, it does, but this should happen automatically after selecting one of the radio
    buttons on the original pop-up & selecting print.
    Please help. I don't know what to do and can't enable a debugger from the pop-up and if going though QA11,
    I can't get it to stop inside the print program (only inside the custom FM).
    Cheers,
    John

    hi
    kindly check whether this FM will work for you QFOA_OBJECT_STATUS_SET
    regards
    thyagarajan

  • Trigger follow up action in Auto UD

    Hello Gurus,
    we have defined follow up action after making UD of inspection lot. the logic is to move the stock from one Sloc to other after UD is made.
    This follow up action works well when we make UD in QA11 (foreground). however, we observed that. when we make Auto UD using background job, the follow up action is not triggered.
    Is there any config we are missing? or this is a standard functinality?
    Thanks.
    S J

    Hi,
    To my understanding there is no further special configs available which is not working in background but in foreground it is working and MvT 311 is happening successfully.
    If you are using any custom MF linked to the follow-up actions, then better you speak to ABAP team colleague to double check if the assigned FM is background compliant too.
    If you are using any standard FM, please can you share the same with us so that if someone has worked with it, they may share their thoughts.
    Thanks,
    Arijit

  • Follow up action in QM

    Hi All,
    Could any let me know what is the use and process of followup action in QM during notification.
    Regards,
    Satyajit

    It is applicable for the tasks that you perform in QM notification.
    In QS 42
    code group catalog = 2
    code group = *
    in side select any code froup and then click on codes
    for each code you can give follow up action, if this code is sellected in QM notification then system will trigger the follow up action assigned,
    Std follow up cation given by SAP are
    ABGLEICH     Comparison: R/3 notif. w/ SAP
    AWE     Change request
    CLAIM     Create claim
    CLMMAIL     Mail from claim
    CLMSIMUL     Create simulation version
    DELIVERY     Create outbound delivery
    EXAMPL_1     Example (dummy function module)
    G_MOVE     Enter goods movements
    REP_ORD     Create repair order/dep. follow-up func.
    REP_VE     Record decision in repair order
    SR_ECR     Create EngChangeReq./dep.follow-up func.
    SR_ECR2     Create EngChangeReq./dep.follow-up func.
    SR_PCRFL     Document flow for PCR
    UD     Record usage decision
    VL02     Change outbound delivery

  • Reg. commit work in a follow-up action

    friends
       i am using the following approach to solve a requirement which is posted in this thread..How to send a mail after a usage decision is made in QA11?
    got a nice reply too
      i have defined a follow-up action and assigned a customized mail-sending fm to it..my doubts are, i am on 4.7..am able to send the mail to an internal id, but the problem is without using commit work and submit rsconn01 commands, am failing in doing the same...i have read in a thread that commit work or submit (if the called program uses commit work) will cause data inconsistencies and will trigger locks if it's used in any user-exit or badi...but in my case, when will a follow-up action actually take place? will it happen after all the database commits? if so, then i believe that even i use commit work and submit commands in my z mail sending fm, it wouldn't cause any problems...am just sort of afraid whether this approach is the correct one? or triggering the mail code from the last user exit or badi itself will solve the purpose? i believe not..please guide me on this friends...helpful replies will be appreciated and awarded..thanks in advance
    Regards,
    Sathish. R

    less views and no answers:-(

  • Send mail as follow-up action in reporting agent

    I need to send a mail with the exceptions flaoting from a query. I tried to use the follow-up action of 'send mail' in the reporting agent. that didnt work because in our SAP we're not using the exchange connector and mails cannot be sent in the regular way.
    I have an external command of sending mail.
    Does anyone has a way of solving this problem, meaning, using my external command of sending mail in order to send the mail with the exceptions (this command works just fine in process chains, for example, for notification of process progress)
    Thank You,
    Yoav.

    Hello Nili,
    I think you can edit content and Subject etc.
    http://help.sap.com/saphelp_nw2004s/helpdata/en/21/35783b82ee5d31e10000000a114084/content.htm
    Hope this helps.
    San.

Maybe you are looking for

  • Account assignment U for materials

    i am encountering a problem while i am invoicing a Balnket PO. In PO i have chosen U and B as account assignment and Item cateory But when i am doing miro for partial amount by first going to Layout account assignment-cost centre and than selecting m

  • Apex Installation not working

    Is Apex 4.0 Installation so difficult?! Tried a basic installation a few times. It is not working. But I can remember a few months ago I had installed 3.2 successfully. I removed the entire schemas and installed a fresh Apex 4.0 installation again. O

  • GETURL ERROR

    Dear all, I need help with this code: bigImage.productTitle["txtlink"].onRelease = function(){             getURL("+linktxt+","_blank"); linktxt is an attributes from xml = "pdf files" i apreciate your help MELAS

  • Functional Spec for Purchase Order Layout Sample

    Hi, Can somebody please assist me with a sample Functional spec. for defining a PO form/ layout? Thanks

  • How can I get the most out of my iBook G4 (2005)?

    Hi there! In 2005 I purchased my first Mac, an iBook G4 14.1 in. and to this day I still have it, in fact, it's what I'm typing this with and it's the only laptop I have. Is there any way that I'd be able to upgrade it to be usable for at least 2 mor