Where can i find a utility that works with the LSI Raid controller to check the status of a Raid 1 array directly from Windows Server 2008. I have seen posts regarding Intel Storagematrix and IBM ServerRaid software but neither of these makes sense for an LSI Raid controller 
Solved!
Go to Solution.

welcome to the forum!
you need LSI MegaRAID Storage Manager.   MSM will allow you to manage arrays from within windows, set alerts, and so on.   the latest version can be found on this page after clicking the downloads tab.   scroll down to MSM for windows and you'll be directed to download version 2.91-05.   the user guide for MSM can be downloaded here.
ThinkStation C20
ThinkPad X1C · X220 · X60T · s30 · 600

Similar Messages

  • Tiered Storage Spaces with LSI RAID Controller 9260-8i (no JBOD) - Performance Drop

    Hello
    I have a Lab-Server with a LSI-Raid-Controller 9260-8i and 2x 256GB SSDs / 6x 600GB HDDs. First I configured the LSI-Raid-Controller with a RAID 1 (2x 600GB HDD) and installed
    Windows Server 2012 R2 with Hyper-V Role on this RAID 1. This works just fine. Then I configured the LSI-Raid-Controller with additional 6x "Raid 0 Drive Groups" where each Drive Group has one single physical drive
    in it. And then I created 6 virtual drives out of these 6 Drive Groups. So far so good: my Windows Server 2012 R2 now sees 6 new Harddrives (4x 600GB HDD and 2x 256GB SSD). I then created a Storage Pool out of these 6 drives (with PowerShell /
    assign MediaType SSD/HDD) and on top of the Storage Pool a "Tiered Storage Space" with Mirror Layout (2x 256GB SSDs mirrored and 2x2x 600GBs  HDD mirrored). This gives me a Tiered Storage Space of about 1.3TB. On this Storage
    Space I created a Virtual Drive of 1.3TB capacity. Success!! It seems to work fine.... Even I do not have a Storage-Controller supporting JBOD directly, I was able to create a Tiered Storage Space!!
    Now where's the problem? Fine-Tuning the LSI-Raid-Controller Settings and the resulting
    Disk Performance....
    1) LSI-Raid-Controller: Virtual Drive Properties: What should I choose? Read Policy (Ahead or no) / Write Policy (Write Back with BBU or Write Through) / IO Policy (Direct IO or cached IO) / Disk Cache Policy (enable or disabled or unchanged)
    / Stripe Size (256 KB or ??). Do these settings conflict with the Windows Server Storage Space Layout?
    2) Windows Server Disk Management (under "Disk XY"):  Write Cache Policy? (activate Write Cache on this Device) 
    3) Windows Server Device Manager (under "Drives" - Microsoft Storage Space Device):  Write Cache Policy? (activate Write Cache on this Device)
    4) Performance - Results with Crystal Disk Mark: the inital Results after setting up the Storage were quite good (Seq R: 550 MB/s and W: 590 MB/s //  512K R: 490MB/s and W: 618 MB/s // 4K R: 18MB/s and W: 37 MB/s  //  4KQD32
    R:270 MB/s and W:37 MB/S) But 2 months later the values dropped to: Seq R: 290 MB/s and W: 170 MB/s //  512K R: 120MB/s and W: 239 MB/s // 4K R: 1.5MB/s and W: 31 MB/s  //  4KQD32 R: 9 MB/s and W: 71 MB/S). Huge loss of performance
    - SSD full? 
    5) Since this is a Hyper-V Server I put some VMs on it. The Performance within the VMs has also dropped accordingly. Are there any
    best practices when placing VHDX-Files on  a Tired Storage Space? I could of course assign one or two VHDX-Files directly to the SSD Tier, but actually I don't want that because that would use too much SSD-Space.
    Any Experts on this Subject?
    Mark

    Hi Mark,
    For the settings of the Raid Controller, it is better to confirm with manufacturer for detailed information. As you said these settings will affect with storage space settings.
    From the description you set the 6 disks as 6 RAID0 groups. Is it supported to leave these disks as JBOD and directly add them into a storage space? If Raid settings will affect storage space performance, this could help us avoiding the RAID settings. 
    As data is already written onto the virtual disk, we may not available to recreate it. You could have a try with following PowerShell cmdlet to see if it will work better after optimize. 
    Optimize-Volume -DriveLetter X -TierOptimize
    If you have any feedback on our support, please send to [email protected]

  • PE 2850 LSI / RAID controller problem

    Dear everyone,
    I would like to ask You for a an advice - recently i bought, what it seemed to be a working PowerEdge 2850 server.
    Since I've never got into working with Dell servers, I've learned trough YT videos that my server should give me at least Ctrl+M menu in order to access Configuration Utility of RAID controller - but I does not ... Only option I get is Ctrl+E which gives me nothing ... So I skipped the settings and went directly for OS installation.
    I tried installing all sorts of OS to it (2003 / 2008 / 2012), but even though I've provided correct drivers on Floppy / USB thumb drive - OS reported there is no space on the destination HDD or it can not be initialized (please see attached image).  
    I even called the guy I bought it from, and he told me that he updated all the firmwares before he sold the server - and that he also finds strange that there is no regular Ctrl+M shortcut.
    He told me that he remembers one firmware update utility with a  blue GUI that asked him something about HDD controller and RAID before updating - but he does not recall which one is it :(
    Please advise.
    Thank You all!

    nexus.so
    The thing is ... when i get to BIOS there is no more RAID as an option to pick ... only Disabled or SCSI ... that is the problem unfortunately - even though there is a RAID key clearly marked on the chassis and beneath it a key plugged into the motherboard ....
    If RAID is not an option, that means that the RAID components are not present. IF the RAID components (ALL THREE - battery, memory, key) are in the system, then they are not functioning (it may also mean the riser board is not working).
    You can install an OS without it, but if you want to try to get RAID working, you can try: power off and unplug, remove RAID battery, remove RAID memory, remove RAID key, remove riser board, insert riser board, insert RAID key, insert RAID memory, insert RAID battery. power on and boot to BIOS to see if you have the option to enable RAID. If not, you will need to replace hardware, starting with the riser board and RAID key.
    If you want to try to install in SCSI mode, use this driver:
    http://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KTK5F

  • C-220M3 RAID controller

    Hello,
    Cisco people has told me C-220M3 has to mandatory bring a RAID controller in it if you configure one HDD...actually Dynamic Configuration Tool doesn't let me configure a C220M3 server with one HDD if I don't add a RAID controller. I'm trying to find a technical explanation for that...as I recall, the old C-200M2 can be configured with one HDD and without any RAID controller at all, and that doesn't pose any problems.
    Any inputs on that?
    Thanks,

    Hi Dani,
    the C200 server has a in-build RAID controller which you could use. However on a C220 there are no similar integrated modules available and you need to choose either a mezz or a PCI (LSI) RAID controller for RAID configuration.
    here is the chapter from the configuration guide:
    http://www.cisco.com/en/US/docs/unified_computing/ucs/c/hw/C220/install/raid.html
    Thanks!
    ./abhinav

  • Brand New RD240 ThinkServer can not see the LSI 8708EM2 RAID Controller During Bootup

    I have a brand new out the box RD240 ThinkServer that can not see the LSI 8708EM2 RAD Controller it came with.  This RAID controller simply does not want to function.  This RAID Cntroller does not show up during the boot up and I even tried putting in a different slot in the riser card, thinkn maybe it was a bad PCI-e slot, but made no difference.  Also the Lenovo Easy Setup software does not find this controller either.  So I'm wondering if there is an issue with the RAID Controller or is it a bad Riser card?  Does anyone have any idea's on what can be done or what I may be missing?

    For a list of Warranty Support contact numbers, please visit:
    http://support.lenovo.com/en_US/feedback/detail.page?LegacyDocID=MIGR-76613
    In the U.S. you can call:  1-800-426-7378 

  • RD330 - using PCIe-based SSD and on-board RAID controller at the same time?

    I've got a RD330 (4304-E1U) with the on-motherboard RAID controller and an OCZ Z-Drive R4 PCIe-based SSD.  Basically the SSD looks to the system like a PCIe SATA controller with a single SATA disk attached.  If I leave the on-board RAID disabled in the BIOS (Setup -> Advanced -> Sata/SAS Configuration -> Disable SCU Devices=ENABLED), then the system sees the OCZ drive just fine and I can select it as my boot device.  Works like a champ, screaming fast.
    I *also* need access to the disks attached to the built-in SAS backplane on the server, but if the on-board RAID is turned off, then you can't access those disks.  When you go into the BIOS setup and turn on the on-board RAID (Setup -> Advanced -> SATA/SAS Configuration -> Disable SCU Devices=DISABLED), then the LSI RAID array configuration shows up during POST (as expected) but the OCZ messages do NOT appear during POST, and the OCZ no longer shows up in the BIOS as a boot device.  It's like the SSD isn't even there when the on-board RAID is turned on.
    I don't really need any RAID functionality on those disks, I just need access to them from the OS, but I need to boot from the SSD in the PCIe slot.  Is there a way for both the on-board RAID controller *AND* an additional PCIe disk controller to be active at the same time?

    I have had a 2.0 USB hub connected to the USP port on my AEBS for almost a year for a printer and a HD. Initially I had intermittent connectivity to the HD but never the printer. As Apple upgraded the software/firmware for the AEBS, the problems have stopped. Reliability has been 100% for several months. Go for it.
    Regards,
    Brian

  • G5 Xserve Harware RAID controller - do all drives have to be connected?

    Hi,
    I am installing a hardware RAID controller into a G5 Xserve. The machine has three drives in it - one 80 GB drive module that has just the operating system installed on it, and two 500 GB drive modules that are currently configured as a RAID 1 array via software. I am aware that I have to reformat the drives after installing the RAID controller, and I have taken appropriate steps for backing the data up. My question, however, is if I will have to attach all three drives to the RAID controller, or whether I can leave the 80 GB module separate (the preferred configuration). Thanks.

    Watch out for the firmware bug on the Apple Hardware RAID - doesn't always fully flush write caches on graceful power down (disconnects from the drives before the caches are fully flushed). I turned in a RADAR bug report in November 2005 (RADAR # 4350243), still open. It was a very difficult bug to pin down and create a reproducible test case - causes mystery garbage blocks from space, especially hard to get reproducible results because of the way RAID 5 works on reads. LSI Logic fixed this bug after Apple's code split from the LSI firmware code (the Apple Hardware RAID card is a rebranded LSI Logic megaraid card with Apple firmware), but it seems unlikely that Apple will ever fix this bug because the Xserve G5 and Apple Hardware RAID card are both EOL.
    Only known workaround of which I am aware is to disable write cache on all LUNs.
    Russ
    Xserve G5 2.0 GHz 2 GB RAM   Mac OS X (10.4.8)   Apple Hardware RAID, ATTO UL4D, Exabyte VXA-2 1x10 1u

  • Shopping For A RAID Controller

    I have seen the Areca brand name on here many times, so I assume they are the best for what we do. But, there are so many models that I have no idea what to look for. I probably won't ever have more than 4 or 6 storage drives plus an SSD system drive. Maybe a couple of external drives and an NAS.
    If I have Windows 7 64-bit
    i7-2600k processor
    ASUS P8P67 Pro motherboard
    32 GB RAM 1600
    GeForce GTX 580 Amp! from Zotac
    AX850 PSU from Corsair
    Every component is reasonably fast, bu I am sick of the senseless limitations of this mootherboard. My drives are aging so they need to be replaced.
    Which specs are important for video editing? Which brand and models are most popular and shoould I wait for some new release?
    Another thought - If a RAID controller is over $400 US, Is it more cost-effective to upgrade to a more capable motherboard/processor with all the ports I need?

    What to look for
    Brand
    Areca or LSI
    Ports
    8 or more
    Card
    PCIe-3.0 8x
    Cache
    512 MB or more
    Multi-lane
    SFF-8087/8088
    Examples
    Areca ARC-1882 series or LSI MegaRAID 9285
    Warning: You have to realize that on your motherboard adding a dedicated raid controller will entail that your video card will throttle down from PCIe-16x to PCIe-8x mode, resulting in a 10 - 15% performance penalty, due to limitations of the chipset. A dedicated raid controller, especially with around 6 disks always outperforms an on-board raid by a wide margin. To see some benchmark results, look here:  Reflections
    To see what meets your requirements, also consider the raid level you want to use. If raid3 or raid30, then LSI is out. You can check out what controllers are popular here: Detailed Results but you have to be registered and logged in to access the page.

  • "Waiting for RAID Controller F/W to become ready..."

    Hello
    Lately I have been getting this message more often than not -- before Windows 7 (not) booting:  "Waiting for RAID Controller F/W to become ready..."
    Any suggestions?
    I have a
    Areca  ARC-1680D-IX 12-ports SAS RAID
    Thanks
    Rowby

    We sell and use these now:
    http://www.intel.com/products/server/raid-controllers/RS2BL080/RS2BL080-overview.htm
    http://www.intel.com/products/server/raid-controllers/RS2PI008/RS2PI008-overview.htm
    But they have more here: http://www.intel.com/products/server/raid/index.htm
    They also use LSI chips like Areca and Atto.
    Eric
    ADK

  • K8N master2-far doesn't detect Areca 1220 raid controller

    Today i purchased the last components for my system. Everything works perfectly except for my Areca 1220 8x pci-e raid controller. As i feared the controller is nowhere to be seen, not in the bios, not in windows. I already had bios version v1.10 but flashed the bios version on the msi site anyway. Nothing changed. On the msi site under "QVL" i see my Areca at the bottom of the list. Does that mean that this MB can work with this controller? What must i do to make it work? I think i have to see it at least in the bios!
    Your help is appreciated. Now 5x 300 GB of storage is doing nothing.
     

    Quote from: Bas on 10-November-05, 20:30:00
    Maybe you need to update the cards firmware.
    I already looked into that matter and found out that the only way to upgrade the firmware or bios is to use their http tool McRAID Storage Manager. This of course is done in windows. Now windows doesn't see my Areca 1200 and so McRAID doesn't see it either. I can't update my Areca.
    This problem is well known by the motherboard manufacturers. Let me quote something from the Areca site:
    Q10150407 - Is there any socket 939 motherboards that work with your model ARC-1210 raid controller? In a SLI board I would use one 16x slot for Graphics card.
    Our PCIe ARC-12xx series controller uses Intel IOP332/333 processor. The Intel high performance IOP (IOP331/332/333) has integrated the bridge chip in the controller. But the original NVIDIA nForce4 SLI chipset BIOS has the problem after Bridge IRQ routing. All controllers use Intel new IOP 332/333, such as Areca, Intel, and LSI have the same IRQ routing problem. Those NVIDIA 939 M/Bs can be worked in the Windows environment. Due to the Windows system takes over the BIOS job, and Linux & FreeBSD need to use the M/B BIOS, so it has problem with our PCIe controller.
    Currently, DFI, Ausu, MSI and Gigabyte have BIOS to solve the problem. If you have problem in this kind of mainboard, please try to manufacture latest BIOS.
    We have tested DFI Lanparty NF4 SLI & ASUS A8N-SLI Deluxe, and Asus A8N-SLI Premium. It works very well with our firmware 1.38 and newest mainboard BIOS. Try to swap the graphic and our controller, if you find some warm boot problem in the Asus A8N-SLI Premium.
    I still think i need an updated bios for the k8n master2-far (ms-9620). The fact remains that there are problems reported with every SLI motherboard. I knew this already from the socket 939 platforms. I was sceptical about the k8n master2-far but thought that a server MB should have no problems. I did ask a question about this however at the shop where i bought this MB. I even found an reply from you to another user who had similar concerns about the Areca controllers and an SLI MB. You said that it should not be a problem. Even so i always kept the possibily open that this problem can happen. And here i am 
    Thanks for your help. More input is always appreciated as i am still waiting for an answer from MSI in the Netherlands about this problem. Right now my server is doing nothing. I hope my raid controller will work very soon.

  • Cannot boot with Perc /2 raid controller

    I have just built a system with K7D + 2 2400 MP, and the system hangs when I try to boot with my Perc/2 raid controller in. I have stripped down to just the following components;
    2 2400 MP
    Perc 2
    1GB ECC ram
    Sapphire ATI Radeon 9000
    When I try to boot the machine it gets as far as trying to load the Perc /2 Bios and hangs.
    The Perc works fine in my old system Tyan Tiger 133 with dual 733 PIII, it also seems to boot up fine in a Tyan Tiger S2460.
    Any ideas on the cause or a work around?
    Thanks.

    Yeah, all the firmware & bios is up to date, have stripped things down to just the motherboard, graphics card & Perc. Tried PCI graphics to elliminate any conflicts there. I have disabled all the on-board controllers too.

  • KT4 Ultra (6590) need update of the Promise SATA RAID Controller PDC20376

    The last Bios update AMI 1.4 for the KT4 Ultra (6590) have built in the bios version 1.00.0.18 for the PDC20376 (Promise 376).
    I can configure 2 maxtor (6E040T0) sata1 in a raid0 array and it works under WinXP SP3,
    but the 2 drives are working in UDMA5 according to the FastBuild Utility when the motherboard specifications talks about 150Mb (SATA1).
    It's not an OS problem because the FastBuild Utility at Bios startup show the UDMA5 mode for HDD.
    It's not a Maxtor 6E040T0 (SATA1) problem because have no jumper to set.
    The Promise support center don't provide support for built in raid controller but the responce was that it's related to a known bios issue of the controller, so i have to update.
    For the last Bios version for the S150 TX4 controller look at:
    http://promise.com/support/download/download2_eng.asp?productId=108&category=all&os=100&go=GO
    It's impossible to update the bios with the promise tool because the controller is integrated in the motherboard.
    I read for example than on the motherboard K7N2 Delta-ILSR the bios version of the Promise 376 controller is 1.00.0.21:
    https://forum-en.msi.com/index.php?topic=92756.msg665966#msg665966
    I think the only solution is a modding bios, where i have to replace only the Promise controller bios but:
    1) The tool amibcp.exe can't open the A6590VMS.140 AMI bios (renamed .rom), i don't know why!!!
    2) What promise controller bios rom file is good?
    Can anyone out there help . . . please ?

    This is my results compared to my other UDMA6 HDD on IDE1, HDTach long bench stop with "Read Error" and only quick bench works.
    The version of the Controller driver under WinXP-SP3 is 1.0.1.29 and I configured the driver in the PAM Utility with:
    "Driver Write Cache" enabled and "Write Back" as cache settings (The 2 Maxtor SATA1 in RAID have 2MB of cache, but i don't know How many cache have the controller!!).
    The Burst Speed is too strange!!! quick bench error?
    I made it so your image is clickable.
    -Frankenputer

  • Continues RAID Controller 2 Fibre LIP

    I recently installed 7 500GB drives on an XRAID server then updating to RAID admin 1.5.1. With 6 drives in RAID 5 and one drive as a hot spare. Then during the initialization of the RAID 5 I received two errors claiming the 2nd channel card was down and cleared them manually and they havnt come back. Also the initilization of the drives took about 42 hours and after the 1.5.1 update there is a high pitched whining sound coming from the server!
    But my main concern now is the constant RAID Controller 2 Fibre LIP warning. I do mean constant...about ever 10-12 seconds.
    Thanks:)

    >The XRAID is connected directly to the back of the Windows Server via a LSI Logix FC929 Fibre Channel Adapter using the same driver as the 1st Fibre Controller.
    I vaguely recall some issue with Windows Server and LIP errors on the XServe RAID, but I don't recall what it was.
    Did you have them before attaching the second RAID? Is only one controller complaining, or both?
    Do you continue to get the errors if you disconnect the original array, leaving just the new one attached (this could indicate a loop problem when both controllers are attached).
    It might also be worth checking out AlienRAID who have a lot of resources for running XServe RAID under 'other' OSes.
    >I cant tell the specific location of the whining sound. But it has to do with either the new drives or the load from the new drives spinning up causing the sound to come from the power supply because it starts after the system is powered on.
    Do you have both PSUs powered? The PSUs are power-sharing, but if one of them fails the other picks up the load. It's designed more for failover, though, than normal operation, and it's just possible that a single PSU is working harder than it should to keep things running.

  • CSCul22968 - LSI Raid cards have patrol read and consistency check with same schedule

    Hello,
    I had this issue and the workaround fixed the issue temporary.
    But i've missed the information, where i may find the Megacli tool for VMware:
    Here is the path to the iso file, which includes the vib files.
    Downloads Home
    Products
    Servers - Unified Computing
    Cisco UCS C-Series Rack-Mount Standalone Server Software
    Cisco UCS C220 M3 Rack Server Software
    Unified Computing System (UCS) Utilities
    VMWare-1.5(4)
    Regards,
    Chris

    Hello Chris,
    You need to download this tool from LSI's website.  LSI is the RAID controller's manufacturers.  Look in google for "MegaRAID SAS XXXX" where XXXX is the RAID controllers model.
    For example, here is this one for the 9260-8i:  http://www.lsi.com/products/raid-controllers/pages/megaraid-sas-9260-8i.aspx  <<< Go to "Software Downloads">  "Management Software and Tools"  > download "MegaCLI 5.5 P2"which is for  "DOS FreeBSD Linux Solaris VMware VMwareMN Windows EFI"
    I hope this helps, if it did, please rate the answer.
    -Kenny

  • T2000 Firmware upgrade, factory default and RAID controller

    1.
    I got this during a "boot net".
    equesting Internet Address for 0:14:4f:f:3c:3e
    ERROR: /pci@7c0/pci@0/pci@1/pci@0,2/LSILogic,sas@2: Last Trap: Fast
    Instruction Access MMU Miss
    [Exception handlers interrupted, please file a bug]
    [type 'resume' to attempt a normal recovery]
    2.
    I noticed that there was a withdrawn firmware upgrade 123482-01 is there going to be an -02?
    with factory defaults set
    ok > set-defaults
    boot disk
    doesn't work
    3. How does the built-in RAID controller affect finding the boot block?

    1 Please contact hardware support.
    2 Here is a quote from the readme file for patch 123482-01
    ...not planning a Solaris upgrade or re-install, then there is no immediate need to downgrade your Sun System Firmware. You can wait for a scheduled maintenance cycle...
    This statement is self explanatory, the firmware patches have an upgrade cycle.
    3 Can you explain more about your issues? There are steps to be taken after initially creating a volume with raidctl so Solaris can use them, it is covered in a system Spectrum InfoDoc, did you login to Sunsolve?