I has one infoobject which is assigned two time-dependant entire hierarchies. The two hierarchies have two different time ranges. But when I ran a query which set a key date and choosed one of two hierarchies. The error happened. Error message "abort Hierarchy has been adjusted. start the query again". I tried again, the problem was still there.
Who can tell me what's the problem?

Hi Robert,
in OSS i found Note 659283 that seems to be suitable: are you runnig with SP lower than 16 on 3.0B or 10 on 3.1C? The message shuod have the Code BRAIN 074 ...
Hope it helps
GFV

Similar Messages

  • Time-dependent BW hierarchies in Analysis for OLAP

    Hi all,
    We are using time-dependent hierarchies in combination with a key date variable.
    Tools used: Query designer based on SAP BW 7.4 and BO 4.0.
    The following steps are executed:
    Report is executed and key date is prompted
    According to the key date, the correct time-dependent organisation hierarchy will be used in drill-down
    Bring up variable screen again and select different key date
    The drill-down changes according to the now correct time-dependent organisation hierarchy
    The above scenario works for BEx Analyzer, BEx Web, Analysis for Office - but not for Analysis for OLAP.
    Whenever I run through this scenario and confirm the updated key date, the following error is displayed:
    cube.get.dimension.info.runtime.error : java.lang.IllegalStateException: There is no default hierarchy for dimension [ORG].
    In the user guide I don't find any specifics about the hierarchies and since it works in all the other applications, I wonder where the error is coming from. I also could not find it anywhere else in the forum.
    Has anyone experienced the same error or any suggestions?

    Hi Peter,
    This issue is captured in SAP Note 1941865. Resolved in 4.0 (8.5, 9.2 or SP10) and 4.1 (1.6 or SP03).
    Symptom
    In BI 4.1, Analysis for OLAP returns errors similar to:"An error occurred in the MDAS service while processing a request from Analysis, edition for OLAP. Try the operation again. If the problem persists, please contact your administrator. (AOC00041)" and/or "cube.get.dimension.info.runtime.error: java.lang.IllegalStateException: There is no default hierarchy for dimension [DIMENSIONNAME]"
    The BW Query the AOLAP workspace is created against has 2 different hierarchies that have the same text description
    Environment
    SAP BusinessObjects Business Intelligence platform 4.0
    SAP BusinessObjects Business Intelligence platform 4.1
    Analysis, edition for OLAP
    Reproducing the Issue
    In CMC, create an OLAP BICS connection to a multi provider
    Connect to BI launchpad and launch Analysis, edition for OLAP.
    Use the connection to create a new workspace.
    The error is observed
    Cause
    This issue has been logged as a defect under ADAPT01720287 for BI4.0 and ADAPT01713663 for BI4.1
    Resolution
    A fix for this issue is included in the following maintenance releases:
    BI4.0:
    Patch 8.5
    Patch 9.2
    Support Pack 10
    BI4.1:
    Patch 1.6
    Support Pack 03

  • Two versions of time-dependant hierarchy?

    Hi,
    Is it possible to have 2 versions of time-dependant( entire hierarchy) .. if yes how... Thanks

    Hi,
    transaction RSD1.
    Change your InfoObject.
    Select TabStrip Hierarchy
    Switch on the flags:
    -with hierarchies
    -Hierarchy is version dependent
    - entire hierarchy is time-dependent
    So this means it is possible. But I have never heared about a need of both in the reporting.
    Kind reg.
    Michael

  • Time dependent Hirarchy Structure

    Hi,
    I need to create Hirarchy, i did not create before,
    Please some one explaine me how to create     Time dependent Hirarchy Structure  in CostCenter InfoObject.
    Please, please help me.
    Thanks

    HI
    Find the below link
    http://help.sap.com/saphelp_nw2004s/helpdata/EN/0e/fd4e3c97f6bb3ee10000000a114084/frameset.htm
    Time-Dependent Hierarchies  
    Use
    In a hierarchy that is not time dependent, the characteristic values are always the same.
    If you want to create views of a hierarchy that are valid for a specific time period, you need to create the entire hierarchy as time dependent.
    If you want to model relationships that change time-dependently, you need to create the hierarchy structure time-dependently.
    Functions
    In InfoObject maintenance, you can set whether and in which ways a hierarchy is time dependent. You can choose from the following:
    ·         whether the hierarchy is not time dependent (Hierarchy Not Time-Dependent). This is set by default.
    ·         whether the entire hierarchy is time dependent (Entire Hierarchy Time-Dependent).
    ·         whether individual node relationships are time dependent (Hierarchy Structure Time-Dependent)
    ·         whether a temporal hierarchy join is used with time-dependent hierarchy structures (Use Temporal Hierarchy Join)
    Entire Hierarchy is Time-Dependent
    You can either load time-dependent hierarchies (see Loading Time-Dependent Hierarchies) or create them in the BI system (see Creating a Hierarchy). When you create a time-dependent hierarchy, you have to enter a validity interval (valid to and valid from fields).
    If an entire hierarchy is time dependent, the system creates hierarchy versions that are valid for separate intervals. The system automatically uses the current valid version in this case. The hierarchy valid in each case can be uniquely identified by its technical name and the From-To Date.
    In the InfoObject tree of the Data Warehousing Workbench, all time-dependent hierarchies under the associated InfoObject are displayed with the corresponding To Date, for example  Time-Dependent Hierarchy 05/31/2000.
    In reporting, the system returns the valid hierarchy when a query is executed using the query key date.
    Within a restructuring company areas, you can create time-dependent versions of a hierarchy for the Main Area InfoObject. This enables you to compare the restructuring over different time periods in a query.
    Time-dependent hierarchy 01/01/1999 - 05/31/1999
    Time-Dependent Hierarchy 06/01/1999 - 12/31/1999
    Main Area NORTH
    Main Area NORTH
    Area 1
    Area 2
    Area 2
    Main Area SOUTH
    Main Area SOUTH
    Area 1
    Area 3
    Area 3
    Area 4
    Area 4
    In reporting, you can work in the individual columns of the report structure with fixed date values. You may want to do this to compare Main Area North in the Time-Dependent Hierarchy 05/31/2000 with Main Area North in the Time-Dependent Hierarchy 06/01/2000 (simulation).
    Time-Dependent Hierarchy Structures
    You can either load time-dependent hierarchies (see Loading Time-Dependent Hierarchies) or create them in the BI system (see Creating a Hierarchy).
    In hierarchy maintenance, you can determine a valid time interval for each hierarchy node (Valid to and Valid from fields).
    In reporting, a hierarchy with time-dependent hierarchy structures is created either for the current key date or for the key date defined for the query. In addition, you can evaluate a hierarchy historically using the temporal hierarchy join.
    You can assign an employee to different cost centers at different times within the context of a restructuring.
    In the context menu of a hierarchy, choose Display Hierarchy to access the hierarchy display: Each node and leaf has been given a date symbol. Hierarchy nodes that are assigned to different places in the hierarchy structure, depending on the time, are displayed more than once. By double clicking on a hierarchy node, you can display the associated validity period for the node relation.
    In the following example, you can double click on the Jones leaf to see that the worker Jones was assigned to region USA between 01/01/1999 and 05/31/1999 and Puerto Rico from 06/01/1999 to 12/31/1999.
    In order to use a hierarchy with a time-dependent hierarchy structure in reporting, you require the following settings in the BEx Query Designer:
                                a.      If you want to evaluate a hierarchy with a time-dependent hierarchy structure for a fixed key date, enter the key date in query definition.
                                b.      If you want to evaluate a hierarchy with a time-dependent hierarchy structure historically, for a key date that is to be derived from the data, choose the temporal hierarchy join option and specify the derivation type for the key date.
    For a more detailed description of the functions and differences between the two evaluation views, see Time-Dependent Hierarchy Structures in the Query.
    In maintenance of the key date derivation type (RSTHJTMAINT) determine the rule you want to use to determine the key date from the data. In this way you determine the time characteristic and way in which the key date is to be derived.
           1.      First determine the time characteristic.
    If you choose a Basic Time Characteristic as a time characteristic (for example, 0CALDAY, 0CALMONTH, 0FISCPER), you can use a key date derivation type of this kind for all InfoProviders that contain exactly one time characteristic that references the selected basic time characteristic. If there are several time characteristics in an InfoProvider that reference the basic time characteristic, you have to either determine the time characteristic more specifically or select a particular time characteristic from a particular InfoSet (Time Characteristic from InfoSet).
           2.      Determine how you want the key date to be derived from the time characteristic.
    The following derivation types are available:
    ¡        First day of the period
    ¡        Last day of the period
    ¡        Delay by number of days (you specify this in the Delay by Days field). In this case, the key date is calculated from the first day in the period plus the number of days specified minus 1. If the key date does not fall within the period, the last day of the period is used.
    Key date derivation type with (basic characteristic = 0CALMONTH, derivation type = u201Cfirst day of periodu201C):
    ·         For January 2005 the key date is calculated as 1/1/2005.
    ·         For February 2005 the key date is calculated as 2/1/2005.
    Key date derivation with (basic characteristic = 0FISCPER, derivation type = u201Cdelay by number of daysu201C and u201Ddelay u201C = 29):
    ·         For K4/01.2005 the key date is calculated as 1/29/2005.
    ·         For K4/02.2005 the key date is calculated as 2/28/2005.
    ·         For K4/03.2005 the key date is calculated as 3/29/2005.
    Note that the way in which you determine the key date derivation type affects performance. The number of data records that the OLAP processor reads corresponds to the level of detail on which the time characteristic and the leaf level lie. For this reason, choose the time characteristic as approximately as possible in order to keep the hierarchy small.
    A small hierarchy has 100 leaves. For a period of 12 months, the OLAP Processor reads 1200 data records at month level. At day level, it reads 36500 data records.
    Regards,
    kumar reddy.k
    Edited by: kumar reddy on Nov 18, 2008 10:50 AM

  • Composite Provider with Time dependent master data

    Hi ,
    we have a infoset and due to some performance issues we are creating a composite provider to replace Info set and that Info set is having Time dependent master data objects  and DSO.. But when I was creating composite provider I do not see two time dependent  objects (Valid from and Valid to ) in composite provider. Composite provider does not have them/ is it a limitation? Appreciate if provide a input on this..  [We are in BW on HANA 7.4 with SP 7 environment]

    Hi Manohar Karunakaram
    I remember that there was the following limitation with Composite provider in terms of time dependent masterdata but it was a little old limitation.(some time in 2013)
    If temporal joins are required where the result set is depending on time-dependent master data, InfoSets have to be used since CompositeProviders can't provide that functionality.
    I am not sure whether it was solved in the latest release and dont remember an OSS where this was addressed.
    BR
    Prabhith

  • Consolidations Planning using BCS PCtr 'Entire Hierarchy time dependant'

    Hi All,
    We are doing CONS planning using BCS Profit Center and this infoobject has the 'Entire Hierarchy time dependant' property and we have two hierarchies one for 2010 and one for 2011.
    If  '0PLANDAT' variable used for the 'Key Date' in the Input Ready Query prooerties, would it take care of bringing up the hierarchy appropriately depending the Plan Year (Fiscal Year) or the period chosen for the planning.
    Is there some place I can find the documentation and the logic for the '0PLANDAT' SAP Exit variable?
    Thanks in advance,
    - Shashi

    Hi,
    a key date in BW is the date that will be used to read time dependent objects as master data attributes or time dependent hierarchy nodes. These time dependend objects all have valid_from, valid_to fields, when the key date is in the interval the corresponding record will be taken. Observe, that a key date has no link to a time characteristic here.
    The idea of 0PLANDAT is to have a variable the can be used in the customizing of time dependent objects in the planning model as characteristic relationships and in a query. The 0PLANDAT settings can be found in the planning specfic settings for an InfoCube in the planning modeler; to use 0PLANDAT in the query ensures that the same key date is used in the planning model and in the query.
    Regards,
    Gregor

  • Hierarchies for  time  dependent

    hi,
       i want the use of  time dependent hierarchies.. and what is the difference between  TIME DEPENDENT  HIERRACHIE STRUCTURE... AND.... ENTIRE HIERARCHIES  IS TIME  DEPENDENT
               I  done with    HIERARCHIES  NOT TIME DEPENDENT.. So, plz explain the  use  for that.. and  if possible give me  any scenarios...
    with regards
    prakash

    Hi
    See this
    http://help.sap.com/saphelp_nw04/helpdata/en/80/1a6702e07211d2acb80000e829fbfe/frameset.htm
    Two clear examples are given
    Bye
    N Ganesh

  • Changing to time-dependent hierarchie of 0CUSTOMER

    Dear Experts,
    I like to change 0CUSTOMER to "entire hierarchie is time-dependent" <b>without losing any existing hierarchy or data</b>. Is that somehow possible? I tried changing the Radio Button, but could not activate the InfoObject;
    <i>"The Hierarchy Table /BI0/HCUSTOMER must be converted incompatibly with an activation of characteristic 0CUSTOMER (changes to the key in the table). Table /BI0/HCUSTOMER contains data. Parts of this data were lost in the conversion."</i>
    I already checked the whole forum and the SAP help, but could not find a suitable note.
    Can someone plase help?
    Thank you very much in advance
    Martina

    Hello Amit,
    Try reading the help documentation for such queries. e.g. Publishing Time-Dependent XML Documents - Knowledge Management - SAP Library
    Regards,
    Lorcan.

  • Problem with Time dependent master data

    Dear All,
    I have 0PERSON master data infoobject. It is getting records extracted from backend R3 and from a different datasource called 'Peoplesoft'. It has a field 'Date of Birth'. Point of concern here is - whether a particular employee is present in Peoplesoft or in R3, his date of birth is constant. Unfortunately someone hs made 'Date of Birth' as a time dependent attribute of the InfoObject 0PERSON.
    We extract data from Peoplesoft from 01.01.1900 to 31.07.2005. From 01.08.2005 onwards, data is getting extracted from R3.There are some employees which are present in Peoplesoft but they are not in R3.
    Problem is occuring when the user is reporting on a relevant Infocube containing this 0PERSON infoobject. He does not see the value for this 'Date of Birth' field for certain employees. The reason for this is that the 'Date of Birth' field is blank in the interval 01.08.2005 - 31.12.9999 as this employee was absent in R3 and hence no record/s got extracted.
    To view this value in the report - Please suggest me a possible remedy. I thought to write a routine but I dont think it is advisable to change a time dependent master data.
    Thanks,
    Srinivas

    Hi,
    There are two ways of solving your issue.
    - Remove the time dependent check box for 0person, delete the transactional data, load the master data again and reload the transactional data.
    - Write a program to extend the 'Date to' value to 31.12.9999 for all employees.
    Ravi

  • I am trying to use the trial creative cloud software on a PC windows 8.1 - I've downloaded and removed Photoshop CC 2014 two times - every time I open the file it says there is a problem and it shuts down and closes. I can open indesign and maybe other ap

    I am trying to use the trial creative cloud software on a PC windows 8.1 - I've downloaded and removed Photoshop CC 2014 two times - every time I open the file it says there is a problem and it shuts down and closes. I can open indesign and maybe other apps but photoshop no. Any ideas?

    I don't think I can access the crash report? Excuse the ignorant questions I'm about to make am a relative tech novice.
    Soo - as mentioned every time I open photoshop it crashes - it just says there's an error and the program will shut down and if there's a solution windows will notify me. Then nothing...
    I've tried to look in photoshop files for the detailed crash report & the system event viewer but cannot find a file with those names. I've also looked in the windows files for files with those names but cannot find them either - so I don't know where to look.
    Any guidance would be great.

  • Regarding performance issue in time dependent hierarchie.

    hai
    we are loading time dependent hierarchies from flatfile to bw,it is weekely load,we have nearly one million records loaded,we got an issues regarding change of these hierarchies timely.when ever there occurs a change in hierarchy a new row is added to the table,it is degrading the performance,can any one of you please suggest  how to over come performance related issues regarding time dependent hierarchies.
    Regards
    Srinivas.G

    hello deven,
    if you are only focusing on your application's performance
    on the aspect of usability i.e. less waiting time, fast
    response UI, i would personally suggest you to use AJAX.
    put some processing part on the browser side and making
    data retrieval from MI asynchronous... this way, your user
    don't have to wait for all data to be presented, but rather
    could work on the data presented in pieces (i.e. asynchronously).
    anyway try googling for AJAX...
    regards
    jo

  • Time Dependent Hierarchies in Bex

    Hello All,
    I have a time dependent hierarchy with the same leaf in two different nodes i.e,
    Mr. Jones was a part of cost center A from 1/1/2001 to 12/31/2003 and he is a part of cost center B from 1/1/2004 to 12/31/2006.
    When I want to run the report for time period 1/1/2001 to 12/31/2006, will the report show Mr. Jones as part of cost center A from 1/1/2001 to 12/31/2003 and as a part of cost center B from 1/1/2004 to 12/31/2006.
    Or do I have to model this as a time dependent navigational attribute. If I do this, can I still display it as a hierarchy.
    Please pour in your inputs.
    Thanks.
    In the infoObject i chose time-dependent hierarchy structure. I've built a new hierarchy, with the same leave in two different nodes. Each leave got different time interval but when i run a report on a period which include the time interval of the two leaves i get only one node...
    Please advice.

    Hello All,
    I have a time dependent hierarchy with the same leaf in two different nodes i.e,
    Mr. Jones was a part of cost center A from 1/1/2001 to 12/31/2003 and he is a part of cost center B from 1/1/2004 to 12/31/2006.
    When I want to run the report for time period 1/1/2001 to 12/31/2006, will the report show Mr. Jones as part of cost center A from 1/1/2001 to 12/31/2003 and as a part of cost center B from 1/1/2004 to 12/31/2006.
    Or do I have to model this as a time dependent navigational attribute. If I do this, can I still display it as a hierarchy.
    Please pour in your inputs.
    Thanks.

  • Is BPCNW 7.5 supports Time dependent Hierarchies ?

    Hi,
    We are maintaing 4 hierarchies for Profit center dimension. Depends on business structure nodes(profitcenters) will move from one parent to another.
    For e.g:
    In 2009 my PC hierarchy looked like
    RBU1
    -- PC1
    -- PC2
    RBU2
    -- PC3
    -- PC4
    And in 2010, PC2 moved under RBU2, and the hierarchy looked like
    RBU1
    -- PC1
    RBU2
    -- PC2
    -- PC3
    -- PC4
    So, now the requirement is if they want to look at 2009 numbers they would want to see the hierarchy roll up of 2009 and if they look at 2010 numbers, they would like to look at the new hierarchy.
    Is this requirement possible in BPC NW7.5 with out maintaining new hier for 2010.
    thanks in advance...
    regards,
    Raju

    Hi,
    As such time dependent hierarchies are not supported by SAP BPC 7.5.
    This will be deffinately covered in SAP BPC 8.0 release. BPC 8.0 is the major release of SAP BPC NW version.
    Regads,
    Mahesh

  • WIFI problem when linking two Time Capsule

    Hello community,
    I hope you can help me out here so that I will finally know if I'm doing something wrong or it's just a bug. I own two Time Capsule, an old first 500GB model and a newer 1TB simultaneous double band model.
    I set up my network with the 1TB model and I chose to link all the 802.11n devices I own (MacBook, iMac, 500GB Time Capsule etc) over the 5GHz network and all the others such iPhone, PS3, printer over the 2.4GHz network.
    The kernel is that if I try to connect the 500GB TC model (in order to extend my network and yes, the 1TB model is allowed to be extended) using the 5GHz network I experience problems: green light followed by the amber light...the HDD boots up and the TC connect again but the problem persist...it just keeps connecting/disconnecting.
    On the other hand, If I link the 500GB TC over the 2,4GHz network it just works fine.
    Believe me, I tried resetting many times but nothing happened...I had to switch back to 2,4GHz network in order for it to work properly.
    How can it be? I know that the first TC model can work over 5GHz just fine....(I remember that you could choose which frequency you could use).....so I'm a little astonished...¬¬
    Am I missing something or is it a bug?
    Greetings from Spain

    Did you assign a separate name to the 5 GHz network on our AirPort Extreme
    Hard Drive > Applications > Utilities > AirPort Utility
    Click Manual Setup
    Click the Wireless tab below the row of icons
    Make sure there is a check mark next to "Allow this network to be extended"
    Click the Wireless Options tab
    Assign a separate name for the 5 GHz network
    Then, on the Time Capsule
    Open AirPort Utility, click Manual Setup
    Wireless Mode would be "Extend a wireless network"
    Wireless Network Name would be the exact name of the 5 GHz network that you setup
    Security = Same as Airport Extreme
    Password = Same as AirPort Extreme
    I confirmed that this does work. Does this help you there?

  • Compare two months with time-dependent master data

    Hi gurus,
    I have the requirement to make a query that compares values from two months but the key figures are restricted by a time-dependent atributte, I created a structure restricted with an Exit-variable that fills the month in course and the month before, the issue is that query designer only accepts individual variables so only one month displays data.
    Is there a way to use several key-dates so the time-dependent attributes can be used for especific months?
    Regards,
    Gerardo.

    Thanks Raj,
    If there´s no other option I will include attributes in cube. Check if points are correctly assigned
    Regards,
    Gerardo