Uc500 and cyberdata paging gateway

I am setting up a Cyberdata sip endpoint for paging. I have successfully installed the cyberdata sip intercom on other systems (uc540) and they work well. I am not having much success with the amp. I have tried many configurations in both the uc540 cli and the cyberdata sip paging gateway.. I am including the latest config and the latest debugs.
Cyberdata was a help in the beginning but they are lost as well. When I dial the extension I get a fast busy. No matter how I configure it I get a fast busy when I dial the extension. The unit does show that it is registered with the sip server. It could be an acl issue, but I don’t want to change the acl’s until I know for sure.

this is a paging gateway for loudspeakers. The intercoms that I have configured are working fine. if you like to see the settings I used let me know. When someone presses the call button I have it ringing to a call blast group, when they answer they get a two way conversation and the when they press a button (5) the door opens. I used a vlan1 address on the intercom, but in the settings I used in cli I used the vlan100 address of the sip server.It does show "registered with sip server" thanks
Barry Hunsinger
SBI, LLC
Small Business Integration, LLC
908-265-2006 cell
908-753-0420 fax
[email protected]
[email protected]
Cisco Select Certified
Cisco Small Business Communication Specialist
www.sbi-nj.com
>>> pennautomotive <[email protected]> 5/25/2012 12:42 PM >>>
Home ( https://supportforums.cisco.com/index.jspa )
Re: uc500 and cyberdata paging gateway created by pennautomotive ( https://supportforums.cisco.com/people/pennautomotive ) in SBCS - UC500 - View the full discussion ( https://supportforums.cisco.com/message/3644878#3644878 )
Also is worth mentioning that for me the intercom itself would not show up as registered through its web interface.
Reply to this message by going to Home ( https://supportforums.cisco.com/message/3644878#3644878 )
Start a new discussion in SBCS - UC500 at Home ( https://supportforums.cisco.com/choose-container!input.jspa?contentType=1&containerType=14&container=2195 )
Message was edited by: Barry Hunsinger
The calls to the cyberdata amp are trying to go out to our sip provider, and of course the call fails with a fast busy. how do I keep the call inside and get it to the amp.Is it a dial peer issue ?

Similar Messages

  • Purchase Order to Purchase Order using BPEL and/or XML Gateway

    Hi,
    Is there a way to do create a duplicate Purchase Order in another instance using BPEL and/or XML Gateway? We're looking to do A2A transactions, namely duplicating data from one instance to another (of course the functional setups would have to be the same). Thanks!!

    this is the perfect usace for the upcoming ESB (shuffling data with transforming from A to B) - but this can be done with BPEL too .. there are some solutions to this
    1) on a database level (db to db)
    2) having events setup'ed in the master instance, that fire a process that get's the data
    3) and then using the functions from iRep
    hth clemens

  • What is program roll area and  system paging area?

    hello sir,
    i am new to abap, plz give me the answer for the following question,
    1.what is program roll area and  system paging area?
    2.from these two, system allocate memory from which one of the memory?

    check this link.
    http://help.sap.com/saphelp_nw2004s/helpdata/en/02/96274f538111d1891b0000e8322f96/content.htm
    http://help.sap.com/saphelp_nw2004s/helpdata/en/34/d9c8b9c23c11d188b40000e83539c3/content.htm
    http://help.sap.com/saphelp_47x200/helpdata/en/34/d9c8b6c23c11d188b40000e83539c3/frameset.htm
    Message was edited by: kishan negi

  • Need Urgent Help on Meeting Place Integration with CUCM 7.1 and AS5400 PSTN Gateway

    Hi,
    This is first time I am on this forum.
    I have already tried going through a lot of docs on docwiki.cisco.com but couldn't find complete configuration help.
    I have to integrate Meeting Place 8.X with an existing CUCM and an E1 gateway (PSTN Gateway) AS5400.
    The CUCM is already part of a Telepresence Environment. I need to create a SIP trunk between AS5400 and CUCM 7.1 and then create a Trunk between AS5400 and Cisco Unified MP 8.X and then between CUMP and CUCM.
    I need help on AS5400 SIP Configs as well as parameters I need to cover on CUCM (Though I have done some basic dial-peer configs but they haven't been of much help).
    Then I also need help on AS5400 SIP configs with CUMP 8.0
    Any docs on Integration between CUMP and TP3000 will be of great help too.
    Rgds,
    Asim

    I can get the Ricoh to register as sip endpoint, it answeres then imediatly disconnects. Doing a monitor with Wireshark looks like it attempts to negotiate t38 but fails. Any idea why this fails?
    |160.260684000|         INVITE SDP (g711U)            |                   |SIP From:
    |         |(5060)   ------------------>  (5060)   |                   |
    |160.338806000|         INVITE SDP (t38)              |                   |SIP Request
    |         |(5060)   <------------------  (63435)  |                   |
    |160.339545000|         491 Request Pending           |                   |SIP Status
    |         |(5060)   ------------------>  (5060)   |                   |
    |160.547894000|         406 Not Acceptable            |                   |SIP Status
    |         |(5060)   <------------------  (63435)  |                   |

  • Calibrating 15" MBP LCD and a 22" Gateway LCD correctly?

    No matter how hard i've tried there is no way i can calibrate the LCD on my MBP and the 22" gateway LCD to look the same. I want to have the exact same color profiles but if i select for example the same adobe color profile on my MBP and 22" Gateway, even tho the profiles are the same the differences are quite noticeable.
    How can i calibrate the LCD on my MBP and 22" gateway to be the same?

    After color calibration with the huey, they will be not be exact, but as close as they can be, which is to say, they will be MUCH closer than they are now. I agree with you that the color gamut (the spread of colors possible) is better on the Gateway than it is on the laptop, but I can only tell you I don't think you'll be disappointed if you get the huey (Colorvision Spyder probably works just as good, but I've never used it). The Gateway being better shouldn't be a surprise, given the laptop monitor has other things than just color accuracy to be concerned about (e.g. text crispness, heat, longevity in a mobile setting, compressed resolution rendering).
    One thing I noticed with both monitors once they were calibrated, is the incredible amount of blue I had going on with both. After calibrating, you can go back to color settings before calibrating, and click on before/after buttons. The difference is amazing. The color calibrator renders something like 25 colors from the Greytag MacBeth color chart (same company as the one that makes the Huey) and then matches it to a database, to determine how far your monitor's color settings are from the standard, then adjusts them so they match the Pantone standard colors. Nice, quick, effective.
    The two monitors will also likely be much closer to input (e.g. from your camera) and output (to your printer) once you get it squared away and do a little tweaking of camera and printer (otherwise you'd need to create a profile for each of those too.

  • Difference between SAP NetWeaver Gateway 2.0 and SAP NetWeaver Gateway productivity accelerator for Microsoft

    Hi Experts ,
    Can anyone tell me the difference between SAP NetWeaver Gateway 2.0 and SAP NetWeaver Gateway productivity accelerator for Microsoft ?
    Best Regards,
    SK

    SAP  Netweaver Gateway 2.0 is a product for Exposing ERP data as OData for external consumption which is independent of any Microsoft product. Using this you can model OData services and Expose them for light weight consumption. You can use this in use cases where  you just want to consume the OData in some client or so, and you do not want any kind of accelerators to help you in development or in your integration.
    GWPAM is an interoperability framework from SAP that leverages SAP NetWeaver Gateway and Microsoft technologies enabling customers and partners to easily and quickly compose solutions that consume and extend SAP throughout Microsoft technologies for on premise and on demand deployment. With GWPAM you get components like
    GWPAM Visual Studio Add-On,GWPAM Template,GWPAM Project,GWPAM Outlook Add-In which are very much Microsoft specific.

  • MGCP and H.323 gateways not working together

    We have a 3640 in Mexico defined to our Call Manager here in Atlanta as a H.323 gateway. Also in the same Call Manager is a T1 PRI defined to our PBX as a MGCP gateway. When people in Mexico call phones connected to our PBX we get one way conversations. We have a couple of other H.323 to MGCP gateways situations that don't work. It seems the two are not compatible. Has anyone else ran into this. If so, what was your solution.

    According to your description, I believe that you have a topology like the following diagram.
    MexicoPSTN---?---3640---h.323---CCM---mgcp---gateway?---PRI---PBX
    You didn't mentioned what type of circuit you had between the 3640 and the telco in Mexico or the type of gateway used for MGCP in Atlanta.
    However, there should be no problems with this type of configuration causing one-way audio.
    In this case CallManager talks H.323 to the 3640 in Mexico and talks MGCP to the gateway in Atlanta for the call control. When a call is placed from a PSTN phone in Mexico to a PBX phone in Atl, the call setup will first take place via H.323 between the 3640 and CCM and via MGCP b/w the Atl gw and CCM. After the call setup is complete, the audio stream should be connected directly between the 2 endpoints (ie 3640 gateway and the Atl gateway).
    You should check for IP connectivity between the Mexico 3640 and the Atl router. Note, the call setup could complete successfully b/c both devices can reach the CCM, but can they reach each other when CCM steps out of the picture?
    The following URL will also provide more good info on troubleshooting one-way audio.
    http://www.cisco.com/en/US/tech/tk652/tk698/technologies_tech_note09186a008009484b.shtml
    Hope this helps.
    Shane

  • SAP Business Workflow and SAP Netweaver Gateway - Missing extensible elements

    Hello,
    For a mobile project we use SAP Netweaver Gateway in order to retrieve information from workflows stored into SAP Business Workflow.
    We are able to retrieve standard informations for a workflow but custom fields added into "Extensible Elements" section are lost when exit SAP NG.
    We have checked the configuration of SAP NG (by 4 differents person) and it seems to be OK.
    Do you have an idea why the custom fields are lost during SAP NG processing ?
    Thanks in advance
    Best regards,
    Dominique

    Hi Dominique,
    FYI. SAP Fiori Approve Requests uses task processing service. This may help.
    How to display application data in SAP Fiori Approve Requests app
    Regards, Masa
    SAP Customer Experience Group - CEG

  • Dynamic SQL and PL/SQL Gateway

    This question is kind of out of curiosity...I had created a procedure that used some dynamic sql (execute immediate), and was trying to use it on pl/sql gateway. I kept getting page not found errors until I removed the execute immediate statement, and reverted to using static sql statements.
    I am just curious, is dynamic sql not supported at all with pl/sql gateway?
    Thanks
    Kevin

    > Relax damorgan, no need to be condescending. Of course I read the docs ..
    Well, you're one of the few that actually read the docs.. And one of many that lacked to state any real technical details for forum members to understand the actual problem, the actual error, and what the environment is that this is happening in.
    Remember that you came to this forum for forum members to help you. In order for us to do that, you need to help us understand
    - your problem
    - your environment
    - what you have tried
    What PL/SQL Gateway do you refer to? Thus is an old term for an old product - today in Oracle there are two "gateways" into the PL/SQL engine via HTTP. Via Apache/mod_plsql and via the internal Java servlet web engine called EPG inside Oracle.
    As for what the "Gateway" access to the PL/SQL engine via HTTP.. whether it supports EXECUTE IMMEDIATE or not is like asking if a car "supports" soft drinks or not (just because a human that may consume soft drinks acts as the driver of the car). Not sensible or relevant at all.
    mod_plsql creates an Oracle session to the database instance, and executes a PL/SQL procedure in the database. This is no different from any other client connection to Oracle. Oracle has no clue that the client is mod_plsql and not TOAD or Java or VB or PHP or Perl or whatever else.
    So how can this support or not support the EXECUTE IMMEDIATE command? Does PL/SQL support EXECUTE IMMEDIATE? Well duh...
    Why do you get a generic 404? Because the PL/SQL call made by mod_plsql failed with an unhandled exception. mod_plsql gets that exception and now what? Was a valid HTP buffer created for it to stream to the web browser? If the buffer perhaps partially completed? All that mod_plsql knows is that it asked for a HTP buffer via that PL/SQL call and it got an exception in return.
    A 404 HTTP error is the only reasonable and logical response for it to pass to the web browser in this case.
    PS. to see why mod_plsql fail, refer to the access_log and error_log of that Apache httpd server

  • Windows 7, Firefox and Citrix Access Gateway

    Hello
    I have a PC with Windows 7 Professional (32 bit).
    I have web access to a Citrix Access Gateway, and it works mostly fine in IE9. But when I try to access via Firefox 9.0.1 the CAG writes that no Citrix client is installed. If I click Already installed, I can move forward, but then there's a box up asking if I want to open or save Launch.ICA when I try to open a program. Whatever I choose, it will not work.
    I have a desktop PC with Windows 7 Home Premium and there are no problems even in Firefox 9.0.1. Same version of Citrix Web plugin installed on both PCs and UAC is completely turned off on both.
    If there are more security options than in the Professional Premium - So is there anything I can try to disable the Professional?
    I can not immediately see that I can do so much in Firefox.
    sincerely
    Martin

    I tried to install the extension IE Tab 2 in Firefox.
    It seems to have solved the problem.

  • My FIOS App for iOS and FIOS Quantum Gateway

    I have a new FIOS Quantum Gateway G1100 with a new firmware update including guest Wi-Fi.  When I try to use the My FIOS App on my iPad Air 2 and then access the Router and Wi-Fi information I get an error message unable to retrieve Wi-Fi Details.  When I try to manage the FIOS Quantum Gateway I get an error message IPAddress Missing for VZID.  I'm also unable to access any of the router settings from this app and nothing happens when tap the > symbol.

    Make sure you have the latest version of the MyFios app.  It's version 3.9.2.10, which you can find on the "App Settings" menu or in the App Store's update page.  Updates are handled through the App Store.
    Enjoy.
    If a forum member gives an answer you like, give them the Kudos they deserve. If a member gives you the answer to your question, mark the answer as Accepted Solution so others can see the solution to the problem.

  • Core switch and sub switch gateway

    I have a Layer 3 core switch(backbone) 10.18.16.0/24, and the core switch needs to connect to multiple Layer 2 sub switches.
    The Layer 2  sub switches will connect to multiple workstations. The sub switches network will be 172.20.10.0/24, 172.20.40/24 and so on.
     I use core switch IP 10.18.16.11 to connect to sub switch 172.20.10.0/24. Which gateway IP  should I use for 172.20.10.0/24 ? Should I use 172.20.10.1 or 10.18.16.11 ?
    Thank you for your help in advance.

    I am not sure what you mean by "sup switches", but usually you need a management IP/vlan segment, so you can use it to access the devices.  So if your management segment is 172.20.10.0/24 you assign an SVI to every layer-2 switch and give it an IP in this range and the gateway for all the SVIs should be on the core (172.20.10.1/24
    example:
    access switch-1 172.20.10.11/24
    access switch-2 172.20.10.12/24
    access switch-3 172.20.10.13/24
    and so on
    The default gateway for all your layer-2 switches should be the SVI on the core (172.20.10.1/24)
    HTH

  • Oracle 10.2.03 64bit and dg4odbc in gateway 11

    Hi,
    we want to implement a connection to our informix server
    from oracle 10.2 64bit on a SuSE SLES10 64bit machine.
    So i installed the gateway services for oracle 11g
    I also installed the required patch 5965763
    and configured the listener.ora (extract):
    (SID_DESC =
    (SID_NAME=IFAX)
    (ORACLE_HOME=/opt/oracle/product/11)
    (PROGRAM=dg4odbc) (ENVS=LD_LIBRARY_PATH=/opt/oracle/product/11/dg4/driver/lib:/opt/oracle/product/11/lib)
    and tnsnames.ora (extract):
    IFAXODBC =
    (DESCRIPTION =
    (ADDRESS = (PROTOCOL = TCP)(HOST = tq-ifsrv-neu.tq-net.de)(PORT = 1521))
    (CONNECT_DATA =
    (SID = IFAX)
    (HS=OK)
    and the initIFAX.ora :
    HS_FDS_CONNECT_INFO = IFAX0001
    HS_FDS_TRACE_LEVEL = debug
    HS_FDS_SHAREABLE_NAME = /usr/local/informix/lib/cli/libifcli.so
    set ODBCINI=/etc/unixODBC/odbc.ini
    set LD_LIBRARY_PATH=/usr/local/informix/lib/cli:/usr/local/informix/lib/esql:$LD_LIBRARY_PATH
    set INFORMIXDIR=/usr/local/informix
    The odbc-driver is working fine (tested with:isql -v IFAX0001)
    In oracle i got the message:
    ORA-28500: connection from ORACLE to a non-Oracle system returned this message:
    [Informix][Informix ODBC Driver]Driver not capable.
    ORA-02063 : preceding 2 lines from IFAX
    What is going wrong here?
    Regards Lothar

    i got a trace file by using #isql -v IFAX0001
    [ODBC][2917][SQLFreeHandle.c][268]
    Entry:
    Handle Type = 2
    Input Handle = 0x507fe0
    [ODBC][2917][SQLFreeHandle.c][317]
    Exit:[SQL_SUCCESS]
    [ODBC][2917][SQLFreeHandle.c][203]
    Entry:
    Handle Type = 1
    Input Handle = 0x5079c0
    but there are no entries caused by connecting via dg4odbc.
    the dg4odbc logs into /opt/oracle/product/11/hs/log/IFAX_agt_xxxx.trc
    Oracle Corporation --- FREITAG MRZ 07 2008 12:37:12.104
    Heterogeneous Agent Release
    11.1.0.6.0
    Oracle Corporation --- FREITAG MRZ 07 2008 12:37:12.104
    Version 11.1.0.6.0
    Entered hgogprd
    HOSGIP for "HS_FDS_TRACE_LEVEL" returned "debug"
    Entered hgosdip
    setting HS_OPEN_CURSORS to default of 50
    setting HS_FDS_RECOVERY_ACCOUNT to default of "RECOVER"
    setting HS_FDS_RECOVERY_PWD to default value
    setting HS_FDS_TRANSACTION_LOG to default of "HS_TRANSACTION_LOG"
    setting HS_FDS_TRANSACTION_ISOLATION to default of "READ_COMMITTED"
    setting HS_NLS_NCHAR to default of "AL32UTF8"
    setting HS_FDS_TIMESTAMP_AS_DATE to default of "TRUE"
    setting HS_RPC_FETCH_REBLOCKING to default of "ON"
    setting HS_FDS_FETCH_ROWS to default of "100"
    setting HS_FDS_RESULTSET_SUPPORT to default of "FALSE"
    setting HS_FDS_PROC_IS_FUNC to default of "FALSE"
    setting HS_FDS_CHARACTER_SEMANTICS to default of "FALSE"
    setting HS_FDS_MAP_NCHAR to default of "TRUE"
    setting HS_NLS_DATE_FORMAT to default of "YYYY-MM-DD HH24:MI:SS"
    setting HS_FDS_REPORT_REAL_AS_DOUBLE to default of "FALSE"
    setting HS_LONG_PIECE_TRANSFER_SIZE to default of "65536"
    setting HS_SQL_HANDLE_STMT_REUSE to default of "FALSE"
    setting HS_FDS_QUERY_DRIVER to default of "TRUE"
    setting HS_FDS_SUPPORT_STATISTICS to default of "FALSE"
    setting HS_CALL_NAME_ISP to "gtw$:SQLTables;gtw$:SQLColumns;gtw$:SQLPrimaryKeys;gtw$:SQLForeignKeys;gtw$:SQLProcedures;gtw$:S
    QLStatistics"
    Exiting hgosdip, rc=0
    ORACLE_SID is "IFAX"
    Product-Info:
    Port Rls/Upd:6/0 PrdStat:0
    Agent:Oracle Database Gateway for ODBC
    Facility:hsa
    Class:ODBC, ClassVsn:11.1.0.6.0_0006, Instance:IFAX
    Exiting hgogprd, rc=0
    Entered hgoinit
    HOCXU_COMP_CSET=1
    HOCXU_DRV_CSET=178
    HOCXU_DRV_NCHAR=873
    HOCXU_DB_CSET=178
    HOCXU_SEM_VER=102000
    Entered hgolofn at 2008/03/07-12:37:12
    HOSGIP for "HS_FDS_SHAREABLE_NAME" returned "/usr/lib64/libodbc.so"
    Entered hgolofns at 2008/03/07-12:37:12
    symbol_peflctx=0xaab1d0c0
    hoaerr:0
    Exiting hgolofns at 2008/03/07-12:37:12
    ..... this Block repeats several times .....
    Entered hgolofns at 2008/03/07-12:37:12
    symbol_peflctx=0xaab3a520
    hoaerr:0
    Exiting hgolofns at 2008/03/07-12:37:12
    Exiting hgolofn, rc=0 at 2008/03/07-12:37:12
    HOSGIP for "HS_OPEN_CURSORS" returned "50"
    HOSGIP for "HS_FDS_FETCH_ROWS" returned "100"
    HOSGIP for "HS_LONG_PIECE_TRANSFER_SIZE" returned "65536"
    HOSGIP for "HS_NLS_NUMERIC_CHARACTER" returned ".,"
    Exiting hgoinit, rc=0 at 2008/03/07-12:37:12
    Entered hgolgon at 2008/03/07-12:37:12
    reco:0, name:cdix, tflag:0
    Entered hgosuec at 2008/03/07-12:37:12
    Exiting hgosuec, rc=0 at 2008/03/07-12:37:12
    HOSGIP for "HS_FDS_RECOVERY_ACCOUNT" returned "RECOVER"
    HOSGIP for "HS_FDS_TRANSACTION_LOG" returned ""HS_TRANSACTION_LOG""
    HOSGIP for "HS_FDS_TIMESTAMP_AS_DATE" returned "TRUE"
    HOSGIP for "HS_FDS_CHARACTER_SEMANTICS" returned "FALSE"
    HOSGIP for "HS_FDS_MAP_NCHAR" returned "TRUE"
    HOSGIP for "HS_FDS_RESULT_SET_SUPPORT" returned "FALSE"
    HOSGIP for "HS_FDS_PROC_IS_FUNC" returned "FALSE"
    HOSGIP for "HS_FDS_REPORT_REAL_AS_DOUBLE" returned "FALSE"
    using cdix as default value for "HS_FDS_DEFAULT_OWNER"
    HOSGIP for "HS_SQL_HANDLE_STMT_REUSE" returned "FALSE"
    Entered hgocont at 2008/03/07-12:37:12
    HS_FDS_CONNECT_INFO = "IFAX0001"
    RC=-1 from HOSGIP for "HS_FDS_CONNECT_STRING"
    Entered hgogenconstr at 2008/03/07-12:37:12
    dsn:IFAX0001, name:cdix
    optn:
    ##>Connect Parameters (len=32)<##
    ## DSN=IFAX0001;
    #! UID=cdix;
    #! PWD=*
    Exiting hgogenconstr, rc=0 at 2008/03/07-12:37:12
    DriverName:iclis09b.so, DriverVer: 3.00.0000 3.00.U
    DBMS Name:Informix, DBMS Version:07.25.0000 UC4
    Exiting hgocont, rc=0 at 2008/03/07-12:37:12
    SQLGetInfo returns Y for SQL_CATALOG_NAME
    SQLGetInfo returns 18 for SQL_MAX_CATALOG_NAME_LEN
    Exiting hgolgon, rc=0 at 2008/03/07-12:37:12
    Entered hgoulcp at 2008/03/07-12:37:12
    Entered hgowlst at 2008/03/07-12:37:12
    Exiting hgowlst, rc=0 at 2008/03/07-12:37:12
    SQLGetInfo returns for SQL_IDENTIFIER_QUOTE_CHAR
    SQLGetInfo returns N for SQL_COLUMN_ALIAS
    Exiting hgoulcp, rc=0 at 2008/03/07-12:37:12
    Entered hgouldt at 2008/03/07-12:37:12
    Exiting hgouldt, rc=0 at 2008/03/07-12:37:12
    Entered hgobegn at 2008/03/07-12:37:12
    tflag:0 , initial:1
    hoi:0x75b84908, ttid (len 23) is ...
    00: 42444649 6435352E 30356565 2E372E35 [IFDB.55dee505.7.]
    10: 312E3131 323238 [11.1228]
    tbid (len 10) is ...
    0: 000B0007 000004CC 0104 [..........]
    Entered hgopoer at 2008/03/07-12:37:12
    hgopoer, line 159: got native error -11092 and sqlstate HYC00; message follows...
    [Informix][Informix ODBC Driver]Driver not capable.
    Exiting hgopoer, rc=0 at 2008/03/07-12:37:12
    hgobegn, line 176: calling SQLEndTran got sqlstate HYC00
    Exiting hgobegn, rc=28500 at 2008/03/07-12:37:12 with error ptr FILE:hgobegn.c LINE:176 FUNCTION:hgobegn() ID:SqlEndTran call
    Is there any hint?

  • Client isolation and the Bonjour gateway on WLC 7.4.1

    Hi,
    I am considering upgrading our 5508 WLCs to version 7.4.1 to take advantage of the Bonjour gateway. What I want to do is allow clients on our guest wireless network to access things like the Apple TV in our conference rooms. My intention would be to have the Apple TVs on a separate vlan. Obviously, the Bonjour gateway would allow for access between these 2 networks. The question I have is this. If I have client isolation turned on my guest wireless network, is it still possible for these devices to access Apple TVs on another network?
    Any and all information is appreciated!
    Thanks!

    If the Apple TV on the wireless lan , that wont work.
    here is the reference:
    http://www.cisco.com/en/US/products/hw/wireless/ps4570/products_tech_note09186a0080bb1d7c.shtml
    please make sure to rate correct answers

  • Connecting to Remote Desktop using proxy and Remote Desktop Gateway?

    I have setup a Remote Desktop Gateway server using Windows Server 2012 R2. I am using the Remote Desktop Gateway as an intermediary between to provide the remote desktop session over 443 since 3389 is blocked at many client locations.
    However, I ran into a problem with a client who's using a web proxy.
    Is is possible to configure Remote Desktop to connect via web proxy? If so, how? If not does any one have any suggestions on how to provide a Remote Desktop session via 443 over proxy for situations where you don't control the client's PC or network? Does RemoteApps
    allow for access via web proxy when using RD Gateway?
    The error message is below:
    Your computer can't connect to the remote computer because the web proxy server requires authentication. To allow unauthenticated traffic to an RD Gateway server through your web proxy server, contact your network administrator.
    Thanks for any help!

    Hi,
    My suggestion is to setup a RD Web Access server and make it available for your clients via proxy.
    Remote Desktop Web Access (RD Web Access)
    http://technet.microsoft.com/en-us/library/cc731923.aspx
    Thanks.
    Jeremy Wu
    TechNet Community Support

Maybe you are looking for

  • Status of excise invoice is IN PROCESS after all the process is over.

    Dear All, We have done the migo and the Capture the excise invoice also,But still the status of the excise invoice is showing as IN Process.What could be the reason, Please give the inputs. Thanks in advance. deepti

  • IPC - write java routines or use RFCs

    This is more of a design question. I am new to IPC. We need to write really really huge pricing routines with a lot of hard coded values and case statements for CRM pricing in Java. One approach is to just do it in java. But the other approach is to

  • Calling a stored procedure with argument as column name

    hi i am calling a stored procedure mapping_audit_errors_inserts whose definition is as follows PROCEDURE mapping_audit_errors_inserts ( in_ma_seq_id IN ETL_MAPPING_AUDIT_ERRORS.ma_seq_id%TYPE, in_etl_stage IN ETL_MAPPING_AUDIT_ERRORS.etl_stage%TYPE,

  • HP LASERJET PRO CM 1415 FNW COLOR MFP

    i just got a macbook air and i have a the above laser jet pro and i can print fine i did not have to do anything with the disk it wirelessly hooked me up--but for scanning the mac said i needed the software so i tried to install it from the mac dis t

  • Want to upload PDF file in UI, read the content of PDF and Store in SAP DB

    Hi Experts, I have a new requirement in SAPUI5. I want to upload an PDF file using FileUploader component. Now how to validate this thing only for PDF file. User can only upload PDF file. Next I want to read the content of this PDF file and want to s