UCS240 M3 System status LED Amber blinking

Hi Guys
I have a alarm in the UCS240 . The System status LED Amber is blinking, but in the vCenter nothing appears abnormal.
Please see the captures:
-System Event
-System Status
- CPU
- Memory
- Storage
-Temperature
-Platform Alert
TIA
Cristian

Dear Eric
Time :Fri Dec 20 12:55:17 2013
Severity :Warning
Code :F1008
DN :sys/rack-unit-1/board/storage-FLASH-ctlr-1/vd-HV
Probable Cause :equipmentDegraded
Description :Flex Flash Virtual Drive HV Degraded: please check the flash device or the controller
TIA.
Cristian

Similar Messages

  • D400 - system status LED blinking, network LED blinking

    Hi - Just recently started experiencing this problem with my D400.
    The system status LED is blinking, which according to the user guide means that WHS is either booting or shutting down.  The Network LED shows activity. 
    Problem is that I can't get on the D400 via remote desktop.
    Frustrating.  Talked with support already, said only option is to send in to depot or find a local resource to troubleshoot or fix.  Problem is that we have our music/photos on this thing. 
    Support also said that if we factory reset data on all drives will be erased.
    Looking for help wherever I can get it.  Thanks!
    Scott

    Hi scottdcm, and welcome to the Lenovo User Community!
    To get your music/photos off the system before returning it for service, connect the hard drive(s) to another computer with a SATA connection. An external USB/SATA connector or drive enclosure will also do the job.
    You can also remove any drives you have added before shipping it for service.
    Hope this helps!
    I don't work for Lenovo. I'm a crazy volunteer!

  • SUN Fire V65 - System Status LED - non-critical condition

    Hi guys
    We have a Checkpoint Cluster which is made up of 2 Sun Fire V65 servers.
    The front panel of the servers are showing the System Status LED lights as Blinking Amber , which sun documenation has listed as
    "Blinking amber: Indicates the system is in a non-critical condition" ref: http://dlc.sun.com/pdf/817-2024-12/817-2024-12.pdf
    We have resetead the hardware, cleared ,logs, even change HW etc. The light goes away for some time and then returns.
    Can anyone advise on what to do?
    Sun has the following listed in their Troubleshooting pdf i ref before
    "Non-Critical Condition
    A non-critical condition is indicated with a blinking amber status LED and signifies
    that at least one of the following conditions is present:
    ¡ Temperature, voltage, or fan non-critical threshold crossing.
    ¡ Chassis intrusion.
    ¡ Satellite controller sends a non-critical state, via the Set Fault Indication
    command, to the BMC.
    ¡ A Set Fault Indication command from the system BIOS. The BIOS may use the Set
    Fault Indication command to indicate additional, non-critical status such as
    system memory or CPU configuration changes"
    Is there any Unix / Linux / SPLAT logs I can look at or debugging we can look at.
    Thanks in advance

    Your initial description mentions that you have swapped various pieces of hardware around. I presume that means you used current parts instead of new-never-used components. Are both of the clustered systems showing the same symptoms?
    I can only think of a couple of additional things to try.
    Firstly, those are old boxes. V65's went EOL in January 2005, so yours are at least that old if not older. They are x86 architecture. Have you replaced the CR2032 CMOS battery that's on the systemboard? Have you additionally checked for voltage fluctuations in the data center? A marginal power supply can "mostly work" but it can be effected by an AC mains issue.
    If that doesn't change anything, then you may need to contact Checkpoint. They may be able to point you toward some sort of heartbeat function that is tripping a fault level when it flip-flops between the two systems.
    That's a software investigation and would be outside the scope of this forum.

  • Fp-2000 status LED starts blinking

    The status led of my FP-2000 started blinking twice after turning off my module  and turning  it on again, I already updated the firmware to version 10.4 following the indicated steps. I already tried in safe mode, also reset and format disk , always after configuring  the IP the status button starts blinking twice, again.
    Thank you for your support

    Hi Srael
    Try following this document to see if you can solve the problem
    http://zone.ni.com/devzone/cda/tut/p/id/4466
    Greetings
    Julio Mena

  • C220 M3 System Status LED is Amber

    Hello All,
    I have a C220 M3 server that is running one of our CUCM subscribers and Unity Connection subscriber. I noticed today that it has an Amber light on the chassis. I have looked in VCenter, the ESX host screen, and even the Call Manager application for error statuses, but no errors are mentioned. For some reason, I cannot access the CIMC on that server and the IP address I have for the CIMC is not responding to Pings. Is there any other place I can look to discover what is causing this error light to be on?
    Thanks.

    Dear Eric
    Time :Fri Dec 20 12:55:17 2013
    Severity :Warning
    Code :F1008
    DN :sys/rack-unit-1/board/storage-FLASH-ctlr-1/vd-HV
    Probable Cause :equipmentDegraded
    Description :Flex Flash Virtual Drive HV Degraded: please check the flash device or the controller
    TIA.
    Cristian

  • Cisco AIR -LAP-1142 status led continuosly blinking green

    hello all,
                I have implemented around 46 access points (AIR-LAP-1142) in a customer site and i can see that the led of some of the access points are continously blinking green and no clients are associated to these access points. I have a WISM which has two controllers in it. I can see the particular aps to be joined  in the controller. But my question is that why its not giving me any signal. Please help me as this is very urgent!!.. even if am under the access point the signal is not there. I checked the radio status of the aps and its up. The WLANs are activated from the controller also. Please help mee....!!

    continously blinking green
    This could mean that the AP hasn't joined the WiSM yet.
    Can you console into the AP?  If you can, reboot the AP and post the entire power up and bootup process and include the "sh logs".

  • CFP-2110 controller STATUS LED red blinking after powering up

    Hi,
    Have any one experienced this before:  once we powered up the control panel to the instrument, the cFP-2110 controller would just start blinking the RED STATUS signal.  I checked the manual on cFP-2110 and it says if the red signal comes off more than 4 times, it is an unrecoverable error.  Any recommendation from the board?
    Thanks a lot. 

    Hi,
    The default IP is 0.0.0.0. Do you see this same behavior when booting into safe mode? Please see the cFP-21xx User Manual page A-2.  You can also contact NI support at www.ni.com/support.
    Lynn
    National Instruments
    Staff Systems Engineer

  • FP-1600 Status LED blinks 17 times.

    My FieldPoint bank has 9 modules. I previously had a problem with the FP-TB-10 power and ready lights blinking, but that was because one of my dual-channel modules was not seated correctly. Now the status LED is blinking 17 times. The manual says to contact NI about this. The FieldPoint Explorer seems to find all of the modules correctly, though. Anyone know what's up?

    Aaron,
    I checked the firmware and the FieldPoint Explorer version, and I'm using 3.20 and 3.0, respectively. When I power cycle the FP-1600, the 17 blinks of the status LED go away. Communication works, and all of the devices are found. However, communication does drop out from time to time, and eventually the status LED begins blinking 17 times again.
    A possibly related issue is that the FP-AI-V10 dual-channel module that I have plugged into slot 2 of the FP-TB-10 base causes the FP-TB-10 to flash its power and ready LEDs. Re-seating the FP-AI-V10 seems to fix this, although the module is definitely already clicked into place when I see this problem. Upon reseating (or just pressing on it without removing the module), the FieldPoint Explo
    rer program finds this module.
    I'm tempted to think that this issue with the FP-TB-10 and FP-AI-V10 are unrelated to the FP-1600's status LED blinking 17 times because even with the FP-TB-10 removed from the bank, I still get the flashing LED.
    Any ideas? Also, what is a GPF type error?
    Thanks,
    Jake

  • NI smart camera 1764 Status LED Blinking

    I am using NI smart camera 1764. when i am giving 24 V DC supply to the camera then Power & Status LED is blinking continuously in RED colour. on the other hand pass & fail LED also blinking in RED & GREEN colour alternatively. i am not able to connect camera to my computer through ETHERNET cable & cannot use for my application. 
    Please suggest me the solution as soon as possible.

    Have a look at chapter 6 of this manual:
    http://www.ni.com/pdf/manuals/372429b.pdf
    Adnan Zafar
    Certified LabVIEW Architect
    Coleman Technologies

  • When I plug in apple tv the status light just blinks amber and nothing appears on the screen

    When I plug in my apple tv (first gen) the status light just blinks amber and nothing appears on the screen.  The status light never turns white and won't stops blinking amber.  I've tried to over ride this with the remote, resetting it and trying to revert it to the factory settings.  Is there a way to wake it up or is it a lost cause?

    Welcome to the Apple Community.
    The system looks like it's unable to start up, this could be software but more likely hardware, either way unless it will start up there is nothing a user can do to resolve this.

  • Cisco 1131AG LWAP status led yellow and other leds blinking green

    I have a problem with three AIR-LAP1131AG-E-K9  that joined the controller and the status led turns to yellow after joining the controller while other LEDs are blinking green.
    The APs has no coverage at all although the WCS shows that there is coverage and the 4400WLC shows that the AP interfaces are UP. (The ethernet interface and tha 802.11b,g radio interface is up).
    The SSID broadcast is enabled.
    On the switch the interface is up and there is traffic going in and out of the LAP.
    I tired power reset and factory reset for the APs but the problem remains the same.
    Any ideas for what might be the problem ?!!
    Regards

    Yes the clients are not able to see the SSID broadcasted by the AP.
    But these APs were functioning normally before without any changes to the WLC config.
    I had the same problem with other APs but they went back to normal state after a hardware reset to the APs.

  • Sun Fire X2100  Blinking Status LED...

    We have 3 new Sun Fire X2100 servers at my current job. Just recently the status LED (orange) started blinking. The logs show fine and running a prtdiag shows everything up and running fine. Is there a way to turn off the blinking LED? I have gone over every piece of information I can find and have found nothing about how to turn this off once it has started blinking.

    This may be one of two issues:
    - There's a know ILOM/nge driver bug in eariler releases of S10 x86 (pre 6/06).
    - There's a know issue with an older firmware rev of the BIOS/LOM where the net management port hangs/drops out and triggers the blinking fault LED. Do you know what BIOS revision you are at?
    Most times a mobo swap is NOT the fix. You may be making the problem worse because we have mobos in the supply chain with older firmware revisions.
    On the X2100's I usually have my customers try:
    - Moving the RAM in different slots
    - Updating the BIOS/LOM firmware
    - Running the PC-Check diags
    ... before I send a field tech out to do major surgery.

  • CIsco AIR LAP1131AG E K9 Status LED = Yellow; Ethernet LED = Off; Radio LED = blinking Red, what is this? it isn't in the manual

    CIsco AIR LAP1131AG E K9 Status LED = Yellow; Ethernet LED = Off; Radio LED = blinking Red in a pattern, red off then red red, Our AP isn't working it won't show up on our Cisco WLC 2125 anymore and this is the LED indicators, I've checked in the manual and this combination of LEDs do not exists??

    No cisco web is working perfectly.
    do you have a valid CCO id with smarnet contract ?? then only you can download new IOS for AP:
    Autonomous AP image:
    http://software.cisco.com/download/release.html?mdfid=279537722&flowid=6775&softwareid=284180979&release=12.4.25d-JA2&relind=AVAILABLE&rellifecycle=ED&reltype=latest
    LAP AP image:
    http://software.cisco.com/download/release.html?mdfid=279537722&flowid=6775&softwareid=280775090&release=12.4.25e-JAP&relind=AVAILABLE&rellifecycle=ED&reltype=latest
    Regards

  • My 1st gen apple tv displays a black screen,led status light is blinking orange constant. I have tried all the owners manuel tips but it appears to have locked up. Any advise?

    my apple tv 1st generation appears to have locked up. it constantly now displays only a black screen.No function reset etc from remote use.The led status is constantly blinking orange. I have tried all the manual tips etc but still blank. Any ideas anyone?
    Gary.

    Same/similar thing just happened to me....two days ago or so.  Ran fine for months since going from wifi (major problems) to ethernet now.
    I hadn't been on atv 1 for a few days and had it powered down.  Turned it on and it ran thru the startup video/sequence then did the ole sit on a black screen where you can hear the remote responses (say, if i hit left on the remote - the 'option not available' doink noise is made instead of the usual sound you'd get if you were moving to the left on the menu.....not sure if that description makes sense?
    The 'exit' or moving out of a menu 'noise' does sound, as does the enter/moving into a menu noise. 
    This has happened in the past, but more when i had it set up via wi fi.
    Thing is this time i left it sit on the black screen while reading the paper, and after about 5 minutes, the menu screen finally showed up.  Everything was really sluggish to start - but it was there.  But, then, i reset it to see if the sluggishness would go away, and back to the black screen after the startup video.....and then 5 minutes later, it came up.
    Not sure what is going on...but did have the blinking orange light for a while during the issue.
    Don't think its an age thing as it did this even when i first purchased it....
    Once into a video or music it runs fine (though i did notice that every once in a while with the music playing from my itunes, it would have a second of silence mid song like it paused for a second, and then would resume as if nothing happened.....
    Any ideas whats shaking with this?  Does this sound similar to your issue or am i in a different ball park.

  • CFP 2110 - Status led flashing continously

    I'm running into problem with a cFP 2110.
    During the debugging of my RT application on the cFP, I get an error message "Host IP address not in the access list". At this time, I was unable to download any application to the cFP. the VI server IP access list was configured with *. So all the IP address can access to the cFP.
    I found a procedure on the ni web site to reset the system.
    -Set to safe mode
    -ftp the cFP and delete all the file
    -Remove the safe mode.
    It means that there is no more OS or LabVIEW RT on the system.
    Now, When I restart the cFP, the Status led is flashing continously (1 flash / 1.5s) and I don't have access anymore to the cFP in MAX.. Can some one help me on this case ? .
    Thanks
    Attachments:
    Ni_recommendations.pdf ‏126 KB

    Hi Poussin,
    I would recommend flipping the Reset IP dip switch (dip switch 7).  This
    should get the controller to show up in Measurement and Automation
    Explorer(MAX) as 0.0.0.0.  If you can't see the controller, you may want
    to try turning off your firewall.  Often computer firewalls will prevent
    customers from seeing unconfigured controllers in MAX. 
    Once you find your controller, you can flip the reset IP dip switch back to the
    off position and reset the IP address.  For more information on this,
    click on your FieldPoint controller in MAX that will be displayed as
    0.0.0.0.  In the MAX help that appears on the right, click on the link
    titled, "Configure Network Settings."  If you need assistance
    choosing an IP address, please look at this KnowledgeBase. 
    Once you have assigned an IP address to the controller, the status light should
    stop blinking once.   You will then need to install software. 
    Here is a general
    document that describes how to assign an IP address and install software.
    Please let me know if you have any other questions.
    Regards,
    Ching P.
    DAQ and Academic Hardware R&D
    National Instruments

Maybe you are looking for